Electrical Fixture Layout Plan For Ground Floor Habib07

The document contains a legend describing various electrical symbols used on electrical plans including floor distribution boards (FDB), sub distribution boards (SDB), junction boxes (TJB), switches (DP, SB), outlets (S, P, Q, G, TEL), lights (ML, WL, TL, CF, CH, TV), and other items (CB, EX, AC). It also lists the cable and conduit sizes used for different electrical fixtures and connections including lights, fans, power outlets, AC, TV, LAN, and telephone lines. The electrical cable sizes range from 1.3/1.5 rm to 6RG and conduit sizes range from 1/2" to 3/4".
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
296 views1 page

Electrical Fixture Layout Plan For Ground Floor Habib07

The document contains a legend describing various electrical symbols used on electrical plans including floor distribution boards (FDB), sub distribution boards (SDB), junction boxes (TJB), switches (DP, SB), outlets (S, P, Q, G, TEL), lights (ML, WL, TL, CF, CH, TV), and other items (CB, EX, AC). It also lists the cable and conduit sizes used for different electrical fixtures and connections including lights, fans, power outlets, AC, TV, LAN, and telephone lines. The electrical cable sizes range from 1.3/1.5 rm to 6RG and conduit sizes range from 1/2" to 3/4".
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

E-01

SYMBOL NAME DESCRIPTION

SCALE: As shown
FDB Floor Distribution Board at 2225mm Height from F.F Level.
Sub Distribution Board at 2225mm Height from F.F Level.

DATE:
SDB
TJB Wifi,TV & Telephone Junction Box at 2225mm Height from F.F Level.
DP Double pole switch at 900mm Height from F.F Level.
SB Switch Board at 900mm Height from F.F Level.
S 2 Pin Outlet
P 3 Pin Outlet at skirting level

1ST TO 3RD FLOOR PLAN


Q 3 Pin Outlet for AC mounted at wall
G 3 Pin Outlet for Geyser at false ceiling
TEL Telephone Line Outlet at skirting
ML Mirror Light 12 Watt 1800mm Above from F.F Level.

MD. HABIBUR RAHMAN

IEB Membership No. M/18007


WL Internal Wall Light (24 Watt) 2225mm from F.F Level.

B.Sc. Engg. (Civil), MIEB


Structural Engineer.
CB Calling Bell
TL LED Tube Light 22 Watts Size 4'
TL LED Tube Light 22 Watts Size 4'
CF 56" Suspended Ceiling Fan (80 Watt) at 835 mm Level below from Soffit.
EX Exhaust Fan

1. Arch. Salma Akter.

2. Md. Hyder Khalifa


(B.Sc. Arch )

(B.Sc. Arch )
CH Chandelier Light Mounted at Soffit .
TV Television Outlet Minimum 150mm Above from F.F Level.
AC

Electrical Cable & Conduit Size

PVC : FIXTURE CABLE CONDUIT RFL


Light , Fan & 2pin Power 1.3/1.5 rm Cable 1/2" Water Grade
3 pin Power 2.5 rm Cable 3/4" Water Grade
AC Power 4 rm Cable 3/4" Water Grade
VILL - PIRUJALI MOYTAPARA .THANA - HOTAPAR , DIST-GAZIPUR.

TV/DISH 6RG 3/4" Water Grade


LAN CAT-5 3/4" Water Grade
BADIUZZAMAL MUJIBUL ISLAM BHUIYAN.AT C.S, & S.A.
PROPOSED 6- STORIED FACTORY BUILDING PLAN FOR

TELEPHONE
NO.- 2666. R.S, DAG NO.-361,MOUZA :- PIRUJALI ,

SDB TO SB 2.5 RM BYA