etap 18
Convergence of Power & Intelligence
Features & Capabilities
etap 18 Innovative Platform & Game-Changing Solutions
®
Intelligent System Modeling & Network Management
etapAPP™, Plot Manager, New Elements & Libraries
Advanced Power System Analysis Modules
Time Series Power Flow, ArcFault™, Distance Relay Protection, Renewable & Microgrid, eTraX™
Innovative Power Management & Automation Solutions
Advanced Distribution Management System, Switch Order Management, SCADA Protocols, Dashboard Views
Major Capabilities New
etap iCE™ - Intelligent Control Enterprise Hardware
Programmable control and Remote Terminal Unit hardware integrated with ETAP applications.
Verified & Validated with ETAP Real-Time™ solutions for optimal performance, fast response, and
cyber security.
etapAPP™ - Field Data Collection & Synchronization
ETAP application designed for field data collection & simultaneous user project management that
synchronizes information with ETAP.
ArcFault™ - Arcing Fault Hazard Evaluation
LG, LL & 3-phase arc fault analysis for systems up to 800 kV. New module provides incident
energy results for open air and enclosed equipment with bolted fault currents up to 60 kA.
StarZ™ - T&D Protection & Coordination
T&D network protection & coordination software to examine the performance of relay functions
including Distance, Directional, Load Encroachment & other protective devices.
eTraX™ - Rail Traction System
Most accurate, user-friendly & flexible software tools for analyzing, managing, and simulating low
& medium voltage train power systems.
TDLF - Time Domain Load Flow
Solve power flows based on time-varying load & generation for 3-phase, 2-phase, 1-phase AC &
DC networks simultaneously in radial or looped configurations.
etap.com 2
etap 18
®
Power System Modeling
One-Line Diagram Plot Manager New
• Enhanced auto-build & layout • Plot & view results from multiple studies
• Enhanced batch print & zoom views • User-configurable plots & settings
• Synchronized presentation views • Customize properties & save as template
• Region classifications & coloring New • Works with all ETAP modules
• Paste data to multiple elements New • User-defined application styles
• Remote connectors • Automatic data fit to plot
–– Support remote connection for CT & VTs New • Automatic label layout
–– Split-differential protection schemes across • Zoom, pan, tile, etc.
nested networks New
–– Avoid intersections for multiple input configuration
Geospatial Diagram Datablock
• Expanded input data & study results
• Intelligent Geospatial Diagram
• Feeder & Substation Diagrams New • Arc Flash results New
• Display results, input, tags
• Geospatial model manager
• User-defined templates
• Import from third-party geodatabases
• Auto-adjusting protective device settings
• Synchronized with one-line diagram
• Download background maptiles from Bing or Google
• Independent tooltip & display New
Maps using ETAP MapServer™ (requires API key) • Duplicate datablocks across multiple views
• Edit Geospatial Diagram similar to the one-line diagram,
such as add, modify, & reconnect elements
• Circuit & feeder tracing ETAP Application
• Decluttering, color themes, user-defined symbols • Installation Wizard New
• Graphical display of study results & alerts • Keyless License Manager
• Study result & alert animation • Ribbon bar for Ground Grid & Cable Pulling New
• Automatic incremental updates • Windows Active Directory authentication New
• Library defragmentation & compaction New
• Improved performance & analysis run-time New
etap.com 3
etap 18
®
Power System Modeling
Elements New
• Series Capacitor
–– User-selectable capacitor location
–– Calculate degree of compensation
–– Consider MOV protection & bypass
• Switched Capacitor
–– Automatic control modes: voltage, current,
power factor
–– Control buses & branches
• Distribution Voltage Regulator
–– Automatic control modes: forward, reverse Rule Book - Harmonic Compliance Limits New
–– Include Line Drop Compensation (LDC) • ANSI/IEEE 519-2014
–– Per-phase voltage regulator adjustment • IEC 61000-3-6: 2008
–– Control based on load side voltage requirements • User-defined grid code & local standards
• ZigZag Grounding Transformer
–– Consider effect in unbalanced studies & harmonics
–– Alert based on nameplate rating
• Traction Power Elements
–– Rectifier - Controlled & uncontrolled
–– Transformers - Booster, Auto, Scott-T
–– Speed, elevation, signal, etc.
–– Insulator & isolators
• Distribution Elements
–– Jumper, cut & open point
–– Distributed load
• Busway (trunking busbar)
–– User-defined or typical impedance Engineering Libraries
–– Alert based on nameplate rating • Distance relay New
• Distribution transformer New
Elements - Dynamics & Safety Modeling • Train rolling stock New
• Busbar • Traction rectifier library New
• Inverter • Sector & profile library
• Wind Turbine Generator • Over 450 new V&V protective device models
• Photovoltaic Array Inverter • Over 40 detailed distance relay models with
manufacturer-specific settings
• HVDC - Voltage Source Converter (VSC)
Equipment Warehouse
• Overhead line – phase, ground, tower/pole
• Overhead catenary
• Power cables
• Distribution transformer
• Low-voltage circuit breakers
• Power fuses
• Railway track
• Equipment reliability
etap.com 4
Data18Collection & Synchronization App - etapAPP™
etap
®
New
Collection & Verification Mobile App
• Collect data, verify existing data & transfer to ETAP • Geotag asset information including pictures &
• View ETAP data on mobile device synchronize with ETAP model
• Create new one-line diagrams on mobile device or • Windows authentication for data security
append to existing • Synchronizes data with ETAP over the network
• Smart connections including auto-insert • Designed for tablets running MS Windows® or
• Layered diagram using composite networks Apple® iOS
One-Line Diagram Data Access
Complete or subsystem User-based data access
network & synchronization
Smart Connect Camera
Auto-insert devices without Capture pictures & link to
breaking connections ETAP model
Smart Touch Data Connection
One finger & two finger Wireless connections &
actions synchronization
Composites Components
Nested one-line diagram View, edit & verify data
using composite networks using property data grid
views
Data Exchange - DataX™
Autodesk Revit® New ArcGIS® Import & Export New
• Import Revit drawings to ETAP • Import ESRI ArcGIS electrical information
• Supports incremental Revit model • Map ArcGIS attributes with ETAP elements & properties
import • Database mapping via graphic user interface
• Support for RVT v2017 – v2019 • Export ETAP GIS electrical data to XML
• Identify & alert modeling issues
• Support for ESRI ArcGIS 10.x
• Auto-generation of one-line diagram
• Smart Connect: Revit Plug-in to ETAP
EMTP - Electromagnetic Transient Program New
• Dedicated module for EMT analysis
MultiSpeak® New • Export ETAP electrical data to PSCAD® & EMTP-RV
• Import & export power system data
• Automatic mapping of attributes
• User-defined mapping of elements & properties
• Supports MultiSpeak v3.0 & v4.0
Model Conversion from SKM PTW New
• Detailed built-in conversion tool from SKM PowerTools®
Universal Mapping New • Converts SKM PTW versions 6.x to 8.x
• Powerful element & property mapping
• One-line diagram conversion based on original layout
• Customizable logic & pre-defined power functions
• Data consistency checking & validation
• Supports CIM, ESRI ArcGIS, MultiSpeak, MS Excel • Automatic protective device settings mapping
• Create & save device library mapping as templates
Common Information Model, CIM New • Import of user-created Time-Current Characteristic (TCC)
• Import & export data from ETAP using CIM XML curves
• User-defined mapping of elements & properties • Support for multiple one-line drawings and MCCs into
composite networks
• IEC 61970 & IEC 61968 standard
etap.com 5
etap 18
®
Power System Analysis
Unified Power Flow New Star™ - Protection & Coordination
• Solve AC & DC systems together • Up to 6 settings group with labels & copy/paste New
• Solve LV power panel, UPS circuits & facility network • Sorting & filtering for device settings report New
simultaneously • Settings report based on substation / bus ID New
• Handle load & source connection below panel
• Globally include one-line diagram during batch print
• Allows for panel & UPS loop connections
• Expanded current & voltage inputs
• Enhanced current limit modeling for inverters
• Phase current summation
• Optimized for multi-core CPU
• Ground & neutral protection for overload function
Motor Starting
• Enhanced inverter model
• Plot Manager interface New
Short Circuit
• Compliance with IEC 60909-2016 Ed. 2.0 New
• Variable fault current vs. voltage
• LV to EHV system fault current calculation
TDLF - Time Domain Load Flow New
• Simultaneous time series simulation of AC & DC Reliability Assessment
networks • Reliability warehouse New
–– Demand & generation • Multiple-phase configurations
–– Diversity factor, demand factor, unbalance • GIS system element handling
factors, etc. • Unbalanced system reliability calculation
–– Voltage drop, energy losses, yield, and costs
• Reliability new indices
• Time series behavior of adjustable devices
–– CTAIDI New
–– Transformer load tap changers
–– ALII New
–– Switched capacitor
–– ACCI New
–– Voltage regulator
• Reliability momentary indices
• Single & multi-year load growth analysis
–– MAIFINew
• Irradiance, temp & load profile library
–– MAIDI New
• Optimized for multi-core CPU
Harmonics & Power Quality
• Compliance with power quality standards
Transient Stability
–– IEEE 519-2014
• Line-line & line-line-ground fault actions New
–– IEC 61000-3-14
• Improved synchronous machine saturation modeling
–– IEC 61000-3-6
• Enhanced frequency-dependent network & generator
• Global, local & individual location compliance rule book models
for voltage & current distortion • Enhanced Motor Parameter Estimation & Tuning (MPET)
• New skin effect models for motors & transformers
• Enhanced built-in excitation system models
• Enhanced current distortion alerts
• Automatic TDD current distortion limit evaluation
LV & Cable Systems
• Enhanced voltage & current alerts with percentile
• Ground Grid & Cable Pulling user interface
multipliers
• User-defined Final Temperature for cable
• Enhanced load equipment cable modeling
damage curve plotting New
etap.com 6
etap 18
®
Arc Flash Analysis
ArcFault™ - NESC C2 - Up to 800 kV New Arc-in-a-Box - 15 to 36 kV New
• Arcing fault hazard evaluation • Extended IEEE 1584-2002 model for 'Arc-in-a-Box'
• Model line-ground & line-line arc faults in open air • Typical and user-defined gaps between conductors
• Model 3-phase arc faults in open air • Conversion factors from High Voltage Arc Flash (HVAF)
• Protective device sequence of operation for to Arc-in-a-Box
line-ground, line-line & 3-phase arc faults • Incident energy reflectivity factors for box size
• Auto-gap, working distance & auto-selection of minimum • Enhanced arc flash analysis data for equipment > 15 kV
approach distance per NESC C2 2012/2017 • Designed for HVAF in renewable energy
• Minimum approach distance with or without tools collector systems
• Altitude & transient overvoltage correction factors
• Automatic or user-defined distance parameters
• Integrated with Arc Flash Result Analyzer
• Customizable coefficient editors
• User-definable PPE requirement editor
• Auto-update for worst-case incident energy
• Global or individual typical input data
• Integrated with Arc Flash datablocks
• Verified & Validated against industry standards
Damage Point for Arc Resistant Switchgear New
• Maximum arc current indicator & label
• Maximum arcing duration indicator & label
• Show arc resistant switchgear damage point
on Star TCC plots
• Evaluate margin with actual arc current on TCC plots
for compliance with IEEE C37.20.7-2007
• Designed-based on IEEE PCIC-2017-03
Arc Flash - IEEE 1584 & NFPA 70E
• Compliance with NFPA 70E 2018 standard New
• Customizable X-factors based on IEEE 1584-2002
• Inverter modeling for renewable systems New
• Label formats for arc flash boundaries (ft.in, ft, in) New
• Enhanced reports & labels for 64-bit MS Office
• User-defined arc flash boundary threshold
• Enhanced one-line diagram annotations
• Arc Flash Result Analyzer fields New
etap.com 7
etap 18
®
T&D Protection & Coordination - StarZ™ New
Protective Relay Performance & Evaluation Plots & Reports
• Simulate model-specific protection settings & functions • Time state plots
including distance, directional & load encroachment • Time distance characteristic plots
• Plot R-X characteristics & seen impedances • Time distance-resistance characteristic plots
• In-depth performance evaluation of impedance relays • Detailed device setting reports
• Evaluate protective device operation & coordination • Export relay settings to xml & Excel formats
• Intelligent alert viewer to identify & resolve setting
& logic errors
Distance Relay
• Virtually animate protective devices operation
• Distance function
• Breaker failure & relay communication
• Scheme logic (input, output, timer, latch, variables)
• User-editable scheme logic
• Expanded current & voltage inputs
• Use real-time operational data for system evaluation
• Digital inputs
• Intuitive relay setting editor
• Phase current summation
• Primary & secondary relay settings based
on actual model • Up to 6 setting groups with labels & copy/paste
• Comprehensive relay library
Embedded Fault Analyses & Power Flow
• Sliding fault analysis
• Single fault analysis for unbalanced networks
• Unbalanced load flow & transmission line
load-ability analysis
• Protective device sequence-of-operation
• Data communication between relays & interlocks
Distance Relay Library
• Detailed distance protection element for over 40 relay
• Fault insertion between CT, VTs & CBs
models:
• Multiple fault locations & resistances analysis
in one-click –– Schweitzer –– ZIV
• Series compensated line evaluation with MOV –– GE Multilin –– ERL Phase
protection –– ABB –– ARCTEQ
• Support mutually coupled lines & single-phase systems –– Schneider –– Toshiba
–– Alstom/Areva –– Universal (Generic)
–– Siemens
etap.com 8
etap 18
®
Renewable & Microgrid
Wind Turbine Generator (WTG) Solar/Photovoltaic Inverter Modeling
• Dynamic models based on IEC 61400-27-1-ed1 New • Current limit model for short circuit
–– Type 3A • Reactive & power factor control with constant
–– Type 3B current limitation
–– Type 4A • Minimum & maximum operating values
for current limits
–– Type 4B
• Low-Voltage Ride Through (LVRT) auto-trip voltage &
• Short circuit modeling per IEC 60909-2016 New duration for incident energy reduction
• Crowbar & current limit short circuit model with
• Enhanced current limit modeling for inverters
active & reactive New
• Inverter modeling for Arc Flash in renewable
• Auto-trip voltage & duration for LVRT
energy systems New
Type 3
Transient Stability
Type 4
• Line-to-line fault event simulation
• Line-to-line-to-ground fault event simulation
• Improved synchronous machine saturation model
• Enhanced built-in excitation systems
Microgrid Modeling
• Enhanced frequency-dependent network &
• Transient Stability (TS) to User-Defined Dynamic Model generator modeling
(UDM) network control signal types
• Microgrid Controller network parameter inputs
• Internal or external inputs from: to UDM New
–– Power system stability network • Improved inverter transient response
–– Real-time input measurements or tags • Enhanced UDM model library
• TS voltage & power flows from network can be • Plot Manager interface New
accessed by UDM Microgrid Controller
• User-defined renewable energy models for Wind
Turbine Generator & Photovoltaic Array New
etap.com 9
etap 18
®
Rail Power Systems - eTraX™ New
AC & DC Railway Simulation Traction Analysis
• Tool for analysis & operation of tractions systems • Train Performance Calculation
• Solve transmission, distribution, traction, & signaling • Solve unbalanced AC & DC systems together
together • Unified AC & DC Time Series Power Flow
• Integrate GIS, planning, protection & operations • Optimized for multi-core CPU
• Energy demand calculation based on train timetables
• Resolve challenges of unbalanced system operation
• Evaluate substation location & capacity
• Determine the impact of various rolling stock
• Determine capacity restrictions & analyze mitigation
methods
• Determine impact of unplanned events on the traction
power system using real-time data
• GIS for overhead catenary system
• Data exchange with third-party applications & templates
• Traction power equipment templates
• Utilize real-time data for Energy Forecasting & Switching
Management Interface
• Verified & Validated (V&V) against benchmarks • Track Editor & Warehouse
• Line Editor & Warehouse
Traction Elements • Route & Timetable Editor
• Overhead Catenary System • Automatically generate train timetable based on number
• Track Resistance
of trains, head-way, dwell time, etc.
• Import train schedule from Excel for faster data entry
• Traction Substation (TSS) & Switching Station (SSP)
• Traction Rectifier - Controlled & Uncontrolled
• Train Station & Platform Results & Plots
• Insulator, Insulated Overlap, Neutral Section & Isolator • Graphical plots using Plot Manager
• Substation & Traction transformers –– Rail energy consumption including maximum, peak &
average rolling demand
–– Auto-transformer
–– Trip profiles - acceleration, speed, elevation, etc.
–– Booster-transformer
–– Substation power flows & voltages
–– Scott-T transformer
–– Train power flows & voltages per route
• Signal, Speed Limit, Level Crossing
–– Rail voltage, track potential
• Distance, Elevation & Bend Radius
• Alerts based on EN 50163 & EN 50329 standards
AC DC
etap.com 10
etapPower
18 System Monitoring & Control - ETAP Real-Time™
®
Advanced Distribution Management System Intelligent Load Shedding Dashboard New
• Long-Term Load Forecasting New • Thin-client HMIs
• Automatically download weather data New • Monitor spinning reserve, load to shed, load status
• Automatic incremental model updates • Automatic & manual trigger controls
• Improved dispatcher training simulator • Graphical load shedding event analyzer & viewer
• Integrated restoration & isolation plans • Hardware communication dashboard
• Historical, Library & Excel data sources
Load Preservation
SCADA System & Architecture • Steady-state & transient response
• MCC / BCC redundancy with disaster recovery • Fast response time (10ms) with secured communication
• Encryption & authentication security • Priority optimization based on number of
• Self-healing strategies trips per time period
• Integrated front-end processor with native
communication drivers Switching Order Management New
• Web services communication • Mobile interface
• Automatic historical data replication • Crew assignment & field confirmation of actions
• Unlimited signals or measurements • Link switching sequences to orders
• Native IEC 60870 protocol New • Scheduled & active order viewer
• Native ICCP protocol New • Control center confirmation of order
• Interface to ADMS & OMS • Estimated time to completion
• Classification & User Access Management including
Area of Responsibility (AOR)
Visualization & Dashboards
• Common workstation & Web HMIs Switching Sequence Management New
• HMI objects library • Unbalanced system validation
• Alarms & Events displays • Transfer to Mobile Switching Order Management
• Service Tags / Operator Notes integrated with
advanced applications New
Alarm Management
• Prioritizes events via graphical & tabular views
Real-Time & Historical Reports New • Integrated SMS & e-mail services New
• User-definable scheduled & on-demand reports
• Real-Time & historical data Generator Operations & Maintenance
• Customizable Alarms & Events reports • Track life operating time & cost
• Web-enabled reporting • Multiple maintenance levels notifications
• PDF & Excel formats • Alerts for due maintenance schedules
Control & RTU Hardware - etap iCE™ New
Controllers Remote Terminal Units Communication Protocols
• Substation Automation • Data Acquisition & Control • IEC 60870-5-104/101
• Intelligent Load Shedding • Field/pole mount RTUs • DNP 3
• Generation Control • Integrated RTU & fault • Modbus
• Data Acquisition detection • IEC 61850
• Secure & Scalable • MMS/GOOSE
Controller • GPRS, xDSL, VSAT, Tetra
etap.com 11
etap.com
Follow us:
Visit etap.com to view the current events schedule. Events are added throughout the year, so be sure to visit frequently for the latest updates.
Quality Assurance Commitment
ETAP is Verified and Validated (V&V) against field results, real system measurements, established programs, and hand calculations to ensure
its technical accuracy. Each release of ETAP undergoes a complete V&V process using thousands of test cases for each and every calculation
module. ETAP Quality Assurance program is specifically dedicated to meeting the requirements of:
Registered to ISO 9001:2015
ISO 9001:2015 10 CFR 50 Appendix B 10 CFR Part 21 10 CFR Part 50.55 ANSI/ASME N45.2
ASME NQA-1 CAN / CSA-Q396.1.2 ANSI / IEEE 730.1 ANSI N45.2.2
Certification No. 10002889 QM08
© 2018 ETAP / Operation Technology, Inc. All rights reserved.
Certain names and/or logos used in this document may constitute trademarks, service marks, or trade names of Operation Technology, Inc.
Other brand and product names are trademarks of their respective holders.
E TA P | 17 Goodyear | Irvine, CA 92618 | +1 . 800.477.ETAP | +1 . 949.900.1000 | [email protected]
B12-18.1NF-SEP2018