Installation Instructions
Installation Instructions
Installation instructions
These installation instructions apply to hyperMILL, hyperCAD-S, hyperCAD/Geometric Engine, hyperMILL ShopViewer,
hyperMILL in Autodesk® Inventor ™ and hyperMILL for SolidWorks®. Any manner of reproduction shall require the prior con-
sent of OPEN MIND Technologies AG.
Since we continuously work on further developments, we reserve the right to implement changes.
Last reviewed: February 2015
Web: http://www.openmind-tech.com
Symbols used
In all OPEN MIND documentation, text sections are identified by symbols to help you find information more quickly. The fol-
lowing symbols may be used:
Installation instructions
1 Scope of delivery
4 Install
8 Administrator manual
9 Trademarks
Installation instructions
Installations instructions
Scope of delivery
1
1 Scope of delivery
Before starting the installation, please check the product delivered for completeness. The
running capability of all OPEN MIND products can be ensured only if the following require-
ments are in place:
• Compatible hardware and software
• Installed dongle driver
• Plugged-in dongle with activated products (when using hyperCAD: valid licence)
• Installed software
hyperMILL in hyper- x x x x x 1)
CAD-S
hyperMILL in hyper- x x x x x 1)
CAD 2009.3
hyperMILL in x x x x x 1)
Autodesk® Inventor®
hyperMILL x x x x x 1)
ShopViewer
CAD interfaces x x x x x 1)
Postprocessors x x x 1)
hyperCAD 2009.3 x x x x x 1)
(32-bit)
hyperCAD 2009.3 x x x x x 1)
(32-bit) Geometric
Engine
1) Delivery by e-mail
Installation instructions 1
3 Requesting licence data
Software copy protection Activation code
3.2 Licences
4 Install
4.1 Overview of the installation process
The installation is always local.
For the CAD-integrated products hyperMILL in Autodesk® Inventor ™ and hyperMILL for
SolidWorks®, a working version of the respective CAD software must have been installed
and already started once. The products hyperCAD and hyperCAD-S can be installed from
the product DVD.
2 Installation instructions
Install
Licence for hyperCAD/Geometric Engine Installing hyperCAD/Geometric Engine 4
To start the installation, place the product DVD in the DVD drive. The installation will start
automatically. Follow the installation instructions.
In the second step, configure the previously installed hyperMILL version using the hyper-
MILL Settings Wizard. For further information, please refer to chap. hyperMILL Settings Wiz-
ard.
After the installation process, activate the licences using the Licence Manager. For further
information, please refer to chap. Activate and Manage OPEN MIND Licence Manager Prod-
ucts.
Installation instructions 3
4 Install
Installing the CAD interfaces Licence for hyperCAD/Geometric Engine
4 Installation instructions
hyperMILL Settings Wizard
Licence for hyperCAD/Geometric Engine hyperMILL settings 5
5 hyperMILL Settings Wizard
You use the hyperMILL Settings Wizard during the hyperMILL configuration to define,
among other things, the language, measurement system and paths for the files created by
hyperMILL.
Please note that the demo data in these tool databases is provided to illustrate
the various functions and is not intended for production purposes. OPEN MIND
disclaims any liability for damages resulting from the use of demo data in a pro-
duction environment.
New database project: This creates a database project on the basis of any existing data-
bases in the .mdb and .db formats.
Please note that you can change all the directories for macro and tool data-
bases at any time later in the hyperMILL settings (tab: Application).
You can also combine databases from different areas. For example, you can combine an
empty macro database and tool database from hyperMILL 2010 into one database project.
You can change the name of the database project as you wish. Click Next when you have
completed all the settings.
Installation instructions 5
6 Activate and Manage OPEN MIND Licence Manager Products
Typical processes Licence for hyperCAD/Geometric Engine
Initial situation
Licensing process
Licence server
1. Install the Licence Manager
2. Attach dongle to USB
3. Start the Licence Manager
4. Select local dongle
5. Turn on network server
6. Close the Licence Manager
6 Installation instructions
Activate and Manage OPEN MIND Licence Manager Products
Search for and select dongle Checking requirements 6
6.2 Checking requirements
• Prior to the licensing process, please check the following:
• Is there Internet access?
• Has the OPEN MIND Licence Manager been installed?
• Has a Codemeter dongle been supplied and plugged into a USB interface of the com-
puter?
• Is there an activation code (5x5-digit string of characters)?
When the Licence Manager is installed, the dongle driver is installed automatically.
The activation and return of licences or OPEN MIND software products requires
an active Internet connection. After the activation, the dongle can be used with-
out an Internet connection.
6.3 Process
Start the OPEN MIND Licence Manager. The software can be found on the Start menu
under OPEN MIND. Finally, close the Licence Manager and start the OPEN MIND software.
Installation instructions 7
6 Activate and Manage OPEN MIND Licence Manager Products
Process Activate or return
The complete activation code can be copied to the fields in one process via the
clipboard. For this purpose, place the cursor in the first field.
Keep your activation codes in a safe place. The codes will also be required to
return products, for example, as part of software maintenance.
Please do not interrupt the activation process as this could damage the dongle.
Once the fields have been filled in, a connection to OPEN MIND is established automatically
and the activation code is checked.
Error, activation code could not be recognised. Check whether the activation code
was entered correctly and that there is an Internet connection, for example, check the fire-
wall settings. If necessary, contact your network administrator. Confirm the successful pro-
cess with OK.
Select the required activation code under Available activation codes.
Activate allocates the product to the selected local dongle. The dongle number is displayed.
If an update is available, the update will be activated.
Return deactivates the product on the selected dongle and returns it to the activation code.
If products are to be returned to OPEN MIND, for example, when changing from local licens-
ing to network licensing, proceed as follows:
1. On the Activation code tab, select the activation code from Available activation codes.
2. The List displays only the products that must be returned.
3. Click Return.
While products still need to be returned to OPEN MIND, the further manage-
ment of products belonging to the activation code is blocked.
Change successful
8 Installation instructions
Activate and Manage OPEN MIND Licence Manager Products
Activate or return Network licence and licence server 6
A dongle for a licence server can be managed locally using any OPEN MIND
Licence Manager. For this purpose, plug the dongle into the local USB inter-
face.
You must start the Licence Manager with administrator rights, for example,
using the Run as administrator Windows function. For this purpose, select
LicenseManager.exe in the program directory and right-click to open the Win-
dows shortcut menu.
If you are working with network licences, specify a product that is to be started regularly on
the computer on the Options tab under Select base product. Otherwise, where available and
permitted, the local dongle will be evaluated or the most extensive product package availa-
ble on the network will be started (Automatic selection).
You can use Additional client info to store a note (for example, phone number and e-mail
address) that is displayed for every user when a licence server is used.
Reload on the Dongle/Licence server tab starts a new search for available dongles and
licence servers. Group list by users sorts the list of products in such a way that the products
currently in use are shown as being allocated to the users. The status bar displays informa-
tion on the settings of the local computer.
Proxy authentication
If you use an Internet proxy with authentication in your company, you must enter the User
name and Password for the proxy on the Options tab in order to activate the licences.
Afterwards, you can log in using the Logon to proxy button. On successful login, the user
name and password are locked for editing and the Activation code tab of the Licence Man-
ager is unlocked.
When an Internet proxy with authentication is used, the activation codes are not stored on
the system and are also not loaded when the Licence Manager is started. They must be
entered separately each time a licence is changed.
Installation instructions 9
7 hyperCAD Licence Manager - Registering a licence for hyperCAD
Specify warning period Activate or return
Example:
thinkOM.Assembly 9AEDYCM2 20131015 V2009.3
3DEDYYDM-W41903922-VK68JKA2-ZLIMIVRD
Now insert the code in the Enter licence code function on the Edit > New licence menu. For
this purpose, place the cursor in the first field.
Wait for the message telling you that the licence has been installed correctly. Confirm this
message with OK.
Repeat this process if there are several lines of the licence code and then close the hyper-
CAD Licence Manager.
You can simplify the registration of a large number of licence code lines by
using a text file of the *.lcm format. Simply copy all the codes to a text file,
rename the file extension to *.lcm and import using the From file function on the
Edit > New licence menu.
10 Installation instructions
Administrator manual
hyperCAD Introduction 8
8 Administrator manual
8.1 Introduction
The following section describes the process of installing and configuring OPEN MIND prod-
ucts from an administrator's point of view. For a better understanding, a detailed knowledge
of Microsoft Windows administration is recommended.
OPEN MIND products are generally installed in large-scale IT infrastructures by network and
system administrators. They have in-depth knowledge of how Microsoft Windows computers
and networks are administered.
This document shows how to install and configure the software on more than one computer
and provides details on integration into the existing infrastructure.
8.2 Installation
OPEN MIND products can be installed as standalone installations in a menu-supported man-
ner or unsupervised. Both methods require you to follow a specific sequence. To be able to
install hyperMILL, a CAD platform must always already be in place on the system. Therefore,
if hyperMILL is not integrated into Autodesk Inventor or SolidWorks, you must first install
hyperCAD or hyperCAD-S together with hyperMILL.
As the standalone installation has already been sufficiently documented in the installation
instructions, this part focuses on unsupervised installation.
8.2.1 hyperCAD
The hyperCAD installation technology is InstallShield with InstallScript. The package can be
installed unsupervised if an answer file was previously generated as part of a reference
installation. This answer file is then used for the automatic installation and has the file exten-
sion .iss.
Start the reference installation with the following command line:
Setup.exe -a -r -f1 <path to answer file>
The installation is configured in the same way that the target computers are to be configured
later on. InstallShield records all responses during the reference installation in the answer
file.
Copy the answer file thus created together with the other files of the product DVD to the net-
work area from which you want to distribute the unsupervised installation. At the very least,
you will need the hyperCAD and Data directories from the product DVD. The answer file is
placed in the hyperCAD folder.
Once everything is prepared, you can start the installation on the target system using the fol-
lowing command line:
setup.exe -a -s -f1 <answer file>
hyperCAD is now installed in the same way as during the reference installation.
On 64-bit systems, the hyperCAD installation does not come with a dongle driver. A 64-bit
version of the Eutron and HASP dongle driver is included on the product DVD in the directo-
ries under Drivers.
The User Account Control has to be deactivated for the hyperCAD installation.
8.2.2 hyperMILL
The installation of hyperMILL can only be carried out once a CAD system has been installed.
hyperMILL is an MSI-based installation that can use different public properties with which to
configure the hyperMILL installation.
INSTALLDIR Path The target path of the installation. The default value is <Pro-
grams>\OPEN MIND. Subfolders are created automatically.
Installation instructions 11
8 Administrator manual
Security settings Registry
HMLANG Lan- English, German, French, .... Sets the product language.
guage
8.4.1 Registry
hyperMILL uses temporary ODBC connections to address databases. For such connections
to be generated, hyperMILL users require additional registry rights in HKEY_LOCAL_MA-
CHINE\SOFTWARE\ODBC. Set precisely the same rights that also apply to power users.
Full access is not required here.
8.5 Registry
There are registry keys that affect the behaviour of hyperMILL during the installation or the
first application start.
HKEY_LOCAL_MACHINE\SOFTWARE\OPEN MIND\...
… common\Configuration\...
• ‘GlobalWorkingSpace (REG_SZ)’ refers to the global working space.
• ‘ProjectDirectories (REG_SZ)’ references the project directories.
• ‘OMConfig (REG_SZ)’ refers to the CFG files that are required for licensing.
12 Installation instructions
Trademarks
Postprocessors in network environments Registry 9
• 'Language (REG_SZ)' defines the default language of hyperMILL.
• ‘TemplateToolDB (REG_SZ)’ references the tool database that is loaded if the docu-
ment and application databases failed to load. (Emergency database).
…common\<Product Version>\Languages
contains the lists of languages that you can select for hyperMILL.
All other database registry keys are user-specific and cannot be used during the installation
process.
9 Trademarks
hyperMILL, hyperCAD and hyperMAXX are registered trademarks of OPEN MIND Technolo-
gies AG.
Verification and simulation technology of hyperVIEW provided by MachineWorks Ltd.
Autodesk Inventor® and the Autodesk® logo are registered trademarks of Autodesk Inc.
CATIA® and SolidWorks are registered trademarks of Dassault Systems SA.
Windows and Windows products are registered trademarks of Microsoft Corporation.
All other brand and product names are registered trademarks of their respective owners.
Installation instructions 13
9 Trademarks
Registry Postprocessors in network environments
14 Installation instructions
Index
A hyperCAD 1-3 S
Activate hyperCAD-S 1-3 Scope of delivery 1-1
hyperCAD/Geometric Engine 1-3
update 1-8 Settings Wizard 1-5
hyperMILL 1-3
Activation Application database project 1-5
Error 1-9 hyperMILL, hyperCAD-S, hyperMILL Software copy protection 1-1
ShopViewer, Licence Manager 1-3
Activation code 1-1, 1-2, 1-7 Software documentation 1-1
Add 1-7 Requirements 1-1
Installation process
Available... 1-7
Copy 1-8
Overview 1-2 T
Error 1-8 Installation technology Target folder 1-3
hyperCAD 1-11 Tool database 1-5
Favourite 1-8
Remove 1-8 Internet connection 1-8
Administrator rights 1-9
U
L USB interface 1-7, 1-9
B Language 1-3 Use hyperMILL
Base product 1-9 Licence 1-2 Power user rights 1-12
Activate 1-3, 1-8 Use project paths 1-5
Count 1-7 User Account Control 1-11
C Expires 1-7
CAD interface 1-1 hyperCAD 1-10
Client information 1-9 Maintenance 1-7 W
Clipboard 1-8, 1-10 Notes 1-7 WIBU Systems 1-2
Codemeter dongle 1-1, 1-2, 1-7 Product 1-7
Computer ID 1-1 Product list 1-7, 1-8
Contents of product DVD 1-1 Used 1-7
Licence agreement 1-3, 1-4
Licence management 1-2
D Licence Manager
Database hyperCAD ... 1-2, 1-10
Demo ... 1-5 OPEN MIND ... 1-1, 1-2
Empty ... 1-5 Licence server 1-7, 1-9
Dongle 1-1 Find 1-9
Driver 1-1 Locate automatically 1-9
Find 1-9 Server name 1-9
Licence server 1-9 Use 1-9
Local 1-1, 1-7 License Manager 1-6
Server 1-1 Licensing 1-1
Software copy protection 1-2 local 1-2
Dongle driver 1-1, 1-7 Licensing process 1-7
E M
E-mail 1-2 Macro database
Enter licence code 1-10 Empty ... 1-5
G N
Global Working Space 1-5 Network licence 1-2, 1-9
Global working space 1-12 hyperCAD 1-2
Group
By product 1-9
By user 1-9 P
Postprocessor 1-1
Back up data 1-12
H Postprocessor data
hyperCAD Read-only access 1-12
Computer ID 1-2 Product DVD 1-3
Try to get licence 1-2 Products
hyperMILL Activate 1-6
Configure 1-5 Project directory 1-5
hyperMILL Settings Wizard 1-5 Project path 1-5
Setting the language 1-5 Proxy authentication 1-9
Specifying measurement system 1-5
R
I Reference installation 1-11
Importing database 1-5 Registry keys 1-12
Information for administrators 1-11 Return 1-2
Installation 1-1 licence 1-8
CAD interfaces 1-4
16 Installlation instructions
Contact
Germany Brasil
OPEN MIND Technologies AG (Headquarters) OPEN MIND Tecnologia Brasil LTDA
Argelsrieder Feld 5 Av. Andromeda, 885 SL2021
82234 Wessling 06473-000 – Alphaville Empresarial
Phone:+49 8153 933-500 Barueri – Sao Paulo
E-mail: [email protected] Phone: +55 11 2424 8580
E-mail: [email protected]
Italy China
OPEN MIND Technologies Italia S.r.l. OPEN MIND Technologies China Co. Ltd
Via Pomè 14 Suite 1608, Zhong Rong International Plaza
20017 Rho (MI) No.1088 South Pudong Road, Shanghai 200120
Spain India
OPEN MIND Technologies Iberia, S.L. OPEN MIND CADCAM Technologies India Pvt. Ltd.
Edificio Albufera Center - Oficina 903 3C-201, 2nd Floor, 2nd Main Road, Kasturi Nagar
Plaza Alquería de la Culla 4, Bangalore 560 043, Karnataka
46910 Alfafar (Valencia) Phone: +91 80 3232 4647
Phone.: +34 960 04 55 02 E-mail: [email protected]
E-mail: [email protected]
Switzerland Japan
OPEN MIND Technologies Schweiz GmbH OPEN MIND Technologies Japan K.K.
Zürichstrasse 25 Misumi Bld. 3F, 1-17-18, Kichijojihoncho,
8185 Winkel Musashino-shi, Tokyo 180-0002
Phone: +41 44 86 03050 Phone: +81 422-23-5305
E-mail: [email protected] E-mail: [email protected]
UK Taiwan
OPEN MIND Technologies UK Ltd. OPEN MIND Technologies Taiwan Inc.
Units 1 and 2, Bicester Business Park 3F, No.153, Hwan-Pei Road,
Telford Road, Bicester Chungli City 320, Taiwan, R.O.C.
Oxfordshire OX26 4LD Phone: + 886 3 4613125
Phone: +44 1865 290003 E-mail: [email protected]
E-mail: [email protected]
USA
OPEN MIND Technologies USA, Inc.
1492 Highland Avenue, Unit 3
Needham MA 02492
Phone.: +1 888 516-1232
E-mail: [email protected]
www.openmind-tech.com