Air Preparation Equipment: Supply of Compressed Air (1 or P) Exhaust (3, 5 or E, R) Silencer
Air Preparation Equipment: Supply of Compressed Air (1 or P) Exhaust (3, 5 or E, R) Silencer
Exhaust (3, 5 or E, R)
Silencer
Pressure regulator
with secondary exhaust
Lubricator
FRL – filter/regulator/lubricator-
assembly
Air preparation
equipment
13
Ai r pr epar ation equip me nt
Contents
2 preparation – modular system
Air
Accessories and spare parts
17
21
EAV – soft start-up valve 23
IDG
– membrane air dryer 25
IDFA
– dryer 26
AF
– high flow air filter 26
SFD
– clean air filter, in-line 27
AMC
– filter silencer 27
AR
& XT13 – high flow regulator 28
ARJ
– miniature regulator 29
ARX
– high pressure regulator 29
ARP
– precision regulator 30
ITV0000
– E/P converter 33
AN
– silencer 34
Series
25 – silencer 34
VBA
– pressure booster 35
IDK
– moisture control tube 36
Subject to changes
14
A i r p r epa r at i o n eq u i p m en t
E
ach unit is equipped with connection threads and
therefore can also be used for single mounting (no
extra adapters needed)
With only a small component stock, a machine can
be equipped with both modular units and separate regu-
lators, filter and lubricators. This also means benefits in
exchange and repair.
The individual units are combined with spacers that
also serve as mounting brackets. Replacement of an in-
dividual unit is easily done by releasing the components
from the spacers. By using threaded adapters, you can
replace units without having to unscrew them. Adapters
for pressure switches, extra ports, shut-off valves etc.
are available as accessories.
Note
Do not exceed stated maximum pressure and tempera-
ture values.
Installation Installation
Before the installation of air preparation unit, make sure The air is pre-filtered with an AF-filter before the micro-
that all debris, cutting oil, dust, etc., are removed from filter (AFM).
the piping.
Pressure regulators
Mounting position
Regulators: Optional Pressure setting AR10–60
Filter/filter regulators/lubricators: Bowl facing down. Pull the adjusting knob straight out. Turn to the desired
The units should be mounted following the arrow pressure. Lock the set value by pressing the knob. For
direction. unhampered pressure setting, at least 60 mm clearance
for the adjusting knob is required.
Bowl
Polycarbonate bowls must not be exposed to synthetic Maintenance
oils, thinner, trichlorethylene, kerosene or other aromatic In case of malfunction, check that:
hydrocarbons. For cleaning, use neutral detergent. A primary pressure is higher than the set output pres-
sure.
Automatic drain B main valves seat is not clogged.
Drain condensate with plastic pipe/tubing Ø6/4 with C membrane or spring have not been damaged.
max. length of 5 m. The pipe is installed in a way that If unregulated air streams through the regulator, this is
condensate is always free to be diverted. most likely due to diaphragm failure.
Subject to changes
15
Ai r pr epar ation equip me nt
Filters Lubricators
Operation The minimum flow given in technical data provide proper
Open the blow-off valve to blow out the collected con- function. As a reference for setting the oil flow, SMC in-
2
densate; do not let the liquid level reach up to the whirl dicates 5 drops/min.
disc.
Operation
Maintenance Lubricators AL30–AL60 can be filled with oil under
In case of malfunction, check if the flow direction is cor- pressure. Remove the filler plug and add oil to the mark
rect. If the flow drops, or if the pressure drop increases “Max. Oil Level”. The quantity of distributed oil is regu-
significantly, the filter element should be cleaned or lated by setting the needle valve.
replaced.
Maintenance
Sub-microfilters In case of malfunction, check that:
A flow direction is correct.
To prolong the life of the filter element it is recommended B oil level is between markings “Min. Oil Level” and
to pre-filter with a microfilter. Replace the filter ele- “Max. Oil Level”.
ment when the pressure drop across the filter reaches C needle valve is not clogged. Clean if necessary.
0.1 MPa, or at least once a year.
Subject to changes
16
A i r p r epa r at i o n eq u i p m en t
2
Filter, filter regulator: 5 µm
Degree of filtration
Microfilter: 0.3 µm; sub-microfilter: 0.01 µm
Max. working pressure 1 MPa (10 bar)
Lubricator: 0.05 MPa (0.5 bar);
Min. working pressure
automatic drain: 0.15 MPa (1.5 bar)
Operating temperature –5 to 60 °C
Series 10 20 30 40 50 60
Pressure gauge 1/16 1/8 1/8 1/4 1/4 1/4
Flow See below
Filter AF Regulator AR
With manual drain Without pressure gauge
Part number Connection Flow Part number Connection
AF10-M5 M5 120 ln/min AR10-M5 M5
AF20-F01 G1/8 800 ln/min AR20-F01 G1/8
AF20-F02 G1/4 800 ln/min AR20-F02 G1/4
AF30-F02 G1/4 2000 ln/min AR25-F02 G1/4
AF30-F03 G3/8 2000 ln/min AR30-F02 G1/4
AF40-F03 G3/8 3500 ln/min AR30-F03 G3/8
AF40-F04 G1/2 3500 ln/min AR40-F04 G1/2
AF40-F06 G3/4 4000 ln/min AR40-F06 G3/4
AF50-F06 G3/4 7000 ln/min AR50-F06 G3/4
AF60-F10 G1 8000 ln/min AR60-F10 G1
Flow: 7 bar up to 0.3 bar (0.03 MPa) pressure drop. With built-in pressure gauge
Elements: We recommend replacement of elements once a year or at Δp 1 bar.
Part number Connection
Filter AF AR20-F01E G1/8
With automatic drain AR20-F02E G1/4
Part number Connection Flow AR25-F02E G1/4
AF10-M5C M5 120 ln/min AR30-F02E G1/4
AF20-F01C G1/8 800 ln/min AR30-F03E G3/8
AF20-F02C G1/4 800 ln/min AR40-F04E G1/2
AF30-F02D G1/4 2000 ln/min AR40-F06E G3/4
AF30-F03D G3/8 2000 ln/min AR50-F06E G3/4
AF40-F03D G3/8 3500 ln/min AR60-F10E G1
AF40-F04D G1/2 3500 ln/min Panel nut not included. For panel nut and bracket, see accessories.
AF40-F06D G3/4 4000 ln/min
Regulator AR – with back flow
AF50-F06D G3/4 7000 ln/min
Without pressure gauge
AF60-F10D G1 8000 ln/min
Part number Connection
AR20K-F01 G1/8
AR20K-F02 G1/4
AR25K-F02 G1/4
AR30K-F02 G1/4
Filter AF Regulator AR AR30K-F03 G3/8
AR40K-F04 G1/2
AR40K-F06 G3/4
AR50K-F06 G3/4
AR60K-F10 G1
With built-in pressure gauge
Part number Connection
AR20K-F01E G1/8
AR20K-F02E G1/4
AR25K-F02E G1/4
AR30K-F02E G1/4
AR30K-F03E G3/8
AR40K-F04E G1/2
AR40K-F06E G3/4
Subject to changes
AR50K-F06E G3/4
Please contact SMC for converting adapter R1/16 to
AR60K-F10E G1
R1/8 AR10 gauge connection. Panel nut not included. For panel nut and bracket, see accessories.
17
Ai r pr epar ation equip me nt
18
A i r p r epa r at i o n eq u i p m en t
2
AWG for ARG and AWG
Part number Connection
ARG20K-F02G1 G1/4 Part number Part number
ARG30K-F03G1 G3/8 ARG20P-260S ARG20P-270AS
ARG40K-F04G1 G1/2 ARG30P-260S ARG30P-270AS
ARG40P-260S ARG40P-270AS
Filter regulator AWG – with pressure gauge in handle
Part number Connection
AWG20K-F02G1 G1/4 Regulator ARG Filter regulator AWG
AWG30K-F03G1 G3/8 – with pressure gauge – with pressure gauge in
in handle handle
AWG40K-F04G1 G1/2
Panel nut ordered separately. Pressure gauge placement can be rotated.
19
Ai r pr epar ation equip me nt
2
(max. working pressure: 0.7 MPa)
Part number Series
IS10M-20-6L 20 Pressure switch IS10M Pressure switch IS10E
IS10M-30-6L 25.30
IS10M-40-6L 40
IS10M-60-6L 50, 55, 60
Pressure gauge G Pressure gauge GP46 – with pressure switch, 0.1–0.8 MPa
Part number Connection Series Pressure Part number Connection Pressure
G27-10-R1 R1/16 10 0–1.0 MPa GP46-10-01-Q R1/8 0–1.0 MPa
G36-2-01 R1/8 20, 30 0–0.2 MPa GP46-10-02-Q R1/4 0–1.0 MPa
G36-4-01 R1/8 20, 30 0–0.4 MPa
G36-10-01 R1/8 20, 30 0–1.0 MPa Panel mounting kit – for GP46
G36-10-01-L R1/8 20, 30 0–1.0 MPa Part number
G46-2-02 R1/4 40, 50, 60 0–0.2 MPa 1305104-4A
G46-4-02 R1/4 40, 50, 60 0–0.4 MPa
G46-10-02 R1/4 40, 50, 60 0–1.0 MPa Pressure gauge GC3 – square, for panel mounting
G46-10-02-L R1/4 40, 50, 60 0–1.0 MPa Part number Connection Series Pressure
Integrated 20, 30, 40,
Panel mounted pressure gauge G46 GC3-10AS
mounting 50, 60
0–1.0 MPa
Part number Connection Port diam. Pressure Integrated 20, 30, 40,
GC3-2AS 0–0.2 MPa
G46-10-01M-C R1/8 + female M5 48.5 mm 0–1.0 MPa mounting 50, 60
ISE35-R
AC30XSE-F03DE-1006 G3/8 30
AC40XSE-F04DE-1007 G1/2 40
AC50XSE-F06DE-1008 G3/4 50, 60
AC50XSE-F10DE-1009 G1 50, 60
20
A i r p r epa r at i o n eq u i p m en t
2
Accessories and spare parts
Connection block Output
Part number Series Connection Part number Series Connection
E100-M5 10 M5 Y110-M5 10 M5
E200-F01 20 G1/8 Y210-F01 20 G1/8
E200-F02 20 G1/4 Y210-F02 20 G1/4
E200-F03 20 G3/8 Y310-F01 25, 30 G1/8
E300-F03 25, 30 G3/8 Y310-F02 25, 30 G1/4
E300-F04 25, 30 G1/2 Y410-F02 40 G1/4
E400-F02 40 G1/4 Y410-F03 40 G3/8
E400-F03 40 G3/8 Y610-F03 50, 55, 60 G3/8
E400-F04 40 G1/2 Y610-F04 50, 55, 60 G1/2
E400-F06 40 G3/4
E600-F06 50, 55, 60 G3/4
Mounting adapter Mounting adapter – with T-bracket
E600-F10 50, 55, 60 G1
Part no Series Part no Series
Output with check valve Y100 10 Y100T 10
– prevents back flow of lubricated air Y200 20 Y200T 20
Part number Series Connection Y300 25, 30 Y300T 25, 30
AKM2000-F02 20 G1/4 Y400 40 Y400T 40
AKM3000-F02 25, 30 G1/4 Y500 40-061 Y500T 40-061
AKM4000-F03 40 G3/8 Y600 50, 55, 60 Y600T 50, 55, 60
Similar to older 1000–6000 series. 1. Y500 series does not fit the size 50 but is
designed for size 40 with 3/4" thread (F06).
Distribution unit – the main connections are not threaded
Part number Series Connection
Y14-M5 10 M5
Y24-F01 20 G1/8
Y24-F02 20 G1/4
Y34-F01 25, 30 G1/8
Y34-F02 25, 30 G1/4
Y44-F02 40 G1/4 Output Mounting adapter Mounting adapter
with T-bracket
Y44-F03 40 G3/8
Mounting
adapter
Fits mounting
Part number Connection adapter
E210-U01 1/8 Y200 & Y200T
E210-U02 1/4 Y200 & Y200T
E310-U02 1/4 Y300 & Y300T
E310-U03 3/8 Y300 & Y300T Adapter
E410-U02 1/4 Y400 & Y400T Adapter E10 Mounting example
E410-U03 3/8 Y400 & Y400T
E410-U04 1/2 Y400 & Y400T Angle adapter – FRL, female taper thread
Fits mounting
Plug – FRL Part number Connection adapter
Subject to changes
Part number Fits mounting adapter E300P-070S-02 Rc1/4 Y300 & Y300T
E210-P Y200 & Y200T E300P-070S-03 Rc3/8 Y300 & Y300T
E310-P Y300 & Y300T E400P-070S-03 Rc3/8 Y400 & Y400T
E410-P Y400 & Y400T E400P-070S-04 Rc1/2 Y400 & Y400T
21
Ai r pr epar ation equip me nt
2 Part number
AR20P-580AS
AR25P-580AS
AR30P-580AS
AR40P-580AS
Fits
AR20, AW20
AR25, AW25
AR30, AW30
AR40, AW40
Part number
NVHS-OG-80
Knob cover AR
Lock brace
C4SL AL40
AL10P-080AS Sight glass AL10
AL20P-080AS Sight glass AL20, 30, 40
22
A i r p r epa r at i o n eq u i p m en t
2
Degree of filtration 5 µm
Max. working pressure 1 MPa (10 bar)
Min. working pressure 0.2 MPa (2 bar)
Operating temperature 0 to 60 °C
Pressure gauge G1/8
Voltage 24 VDC (220 VAC and others on request)
Power requirements 1.8 W
Electrical connection Connection DIN 43650BY (included in EAV)
Enclosure IP65
VP-X538
– valve for safety-related systems
Type VP544/VP744 VP544R/VP744R
Medium Air
Working pressure 0.25–0.7 MPa (2.5–7 bar)
Operation Internal pilot type External pilot type
Operating temperature –10 to 50 °C (no freezing/no condensation)
Voltage 24 VDC
Electrical connection DIN 43650C and M12 connector
Enclosure IP65
Note! No less than 0,25 MPa external pilot pressure (as working pressure). Use external pilot type
if supply pressure may drop or is choked on start-up. Valve must be combined with a relevant
control system in order to comply with EN ISO 13849-1.
■ Easy modular connection to air preparation unit ■ Compact size ■ For control systems
in category 3 and 4 (EN ISO 13849-1) ■ Redundant valves and mechanical feedback on control inputs
Valve
Part number Connection Flow
Subject to changes
23
Ai r pr epar ation equip me nt
2 Medium
Degree of filtration
Max. working pressure
Min. working pressure
Operating temperature
Compressed air
See below
1.0 MPa (10 bar)
0.05 MPa (0.5 bar); 0.15 MPa (1.5 bar) with automatic drain
5 to 60 °C
Size 150 250 350 450 550 650 850
1/8 1/4 3/8 1/2 3/4 1 1 1/2
Connection
1/4 3/8 1/2 3/4 1 1 1/2 2
■ Water separator removes 99% of the condensated water (AMG)
■ Micro and sub-microfilters
■ Automatic drain
AMD and AMH
24
A i r p r epa r at i o n eq u i p m en t
2
Medium Air
Pressure range 0.3–0.85 MPa (3–8.5 bar) 0.3–1.0 MPa (3–10 bar)
Operating temperature –5 to 55 °C –5 to 50 °C
Dew point –20 °C –20, –15 °C –20, –15, –40 °C
Dew point indicator — Req. Standard
Membrane air dryer – standard, dew point –20 °C, discharge 20% Membrane air dryer – low dew point, dew point –40 °C, discharge 25%
Part number Flow, OUT Connection Part number Flow, OUT Connection
IDG1-F02 10 ln/min 1/4 IDG30LA-F02 75 ln/min 1/4
IDG5-F01 50 ln/min 1/8 IDG30LA-F03 75 ln/min 3/8
IDG5-F02 50 ln/min 1/4 IDG50LA-F02 110 ln/min 1/4
IDG10-F02 100 ln/min 1/4 IDG50LA-F03 110 ln/min 3/8
IDG10-F03 100 ln/min 3/8 IDG60L-F03 170 ln/min 3/8
IDG20-F02 200 ln/min 1/4 IDG60L-F04 170 ln/min 1/2
IDG20-F03 200 ln/min 3/8 IDG75L-F04 240 ln/min 1/2
IDG30A-F02 300 ln/min 1/4 IDG100L-F04 300 ln/min 1/2
IDG30A-F03 300 ln/min 3/8
IDG50A-F02 500 ln/min 1/4 Membrane air dryer – standard with connection for
IDG50A-F03 500 ln/min 3/8 discharge flow, dew point –20 °C, discharge 20%
IDG60-F03 600 ln/min 3/8 Part number Flow, OUT Connection
IDG60-F04 601 ln/min 1/2 IDG1-F02-P 10 ln/min 1/4
IDG75-F04 750 ln/min 1/2 IDG5-F01-P 50 ln/min 1/8
IDG100-F04 1000 ln/min 1/2 IDG5-F02-P 50 ln/min 1/4
IDG10-F02-P 100 ln/min 1/4
Membrane air dryer – low discharge, dew point –15 °C, discharge 10% IDG10-F03-P 100 ln/min 3/8
Part number Flow, OUT Connection IDG20-F02-P 200 ln/min 1/4
IDG5H-F01 50 ln/min 1/8 IDG20-F03-P 200 ln/min 3/8
IDG5H-F02 50 ln/min 1/4 IDG30A-F02-P 300 ln/min 1/4
IDG10H-F02 100 ln/min 1/4 IDG30A-F03-P 300 ln/min 3/8
IDG10H-F03 100 ln/min 3/8 IDG50A-F02-P 500 ln/min 1/4
IDG20H-F02 200 ln/min 1/4 IDG50A-F03-P 500 ln/min 3/8
IDG20H-F03 200 ln/min 3/8 IDG60-F03-P 600 ln/min 3/8
IDG30HA-F02 300 ln/min 1/4 IDG60-F04-P 601 ln/min 1/2
IDG30HA-F03 300 ln/min 3/8 IDG75-F04-P 750 ln/min 1/2
IDG50HA-F02 500 ln/min 1/4 IDG100-F04-P 1000 ln/min 1/2
IDG50HA-F03 500 ln/min 3/8
IDG60H-F03 600 ln/min 3/8
IDG60H-F04 601 ln/min 1/2
IDG75H-F04 750 ln/min 1/2
IDG100H-F04 1000 ln/min 1/2
For connection between old and current series of SMC’s modular FRL, please contact SMC.
Facts
Dew Point: Atmospheric dew point.
Flow, OUT: Flow at standard operating conditions.
Discharge: Relationship between flow rate of leakage
flow and flow rate of supply at standard operating
conditions. Contact SMC for details.
Subject to changes
25
Ai r pr epar ation equip me nt
IDFA – dryer
Supply pressure 0.15–1 MPa (1.5–10 bar); K versions: 0.15–1.6 MPa (1.5–16 bar)
2
Incoming air temperature 5 to 50 °C
Ambient air temperature 2 to 40 °C (relative humidity 85 % or less)
Voltage 230 V, 50 Hz
Flow capacity
ISO8573.1 class 4 ISO8573.1 class 5 ISO8573.1 class 6
Type 3 °C dew point 7 °C dew point 10 °C dew point
IDFA3E-23
IDFA3E-23 12 m3/h 15 m3/h 17 m3/h
IDFA4E-23
IDFA4E-23 24 m3/h 31 m3/h 34 m3/h
IDFA6E-23-K
IDFA6E-23-K 36 m3/h 46 m3/h 50 m3/h
IDFA8E-23-K
IDFA8E-23-K 65 m3/h 83 m3/h 91 m3/h
IDFA11E-23-K
IDFA11E-23-K 80 m3/h 101 m3/h 112 m3/h
IDFA15E-23-K
IDFA15E-23-K 120 m3/h 152 m3/h 168 m3/h
IDFA22E-22-K
IDFA22E-22-K 182 m3/h 231 m3/h 254 m3/h
IDFA37E-37-K
IDFA37E-37-K 273 m3/h 347 m3/h 382 m3/h
IDFA55E-23
IDFA55E-23-L 390 m3/h 432 m3/h 510 m3/h
IDFA75E-23
IDFA75E-23-L 600 m3/h 720 m3/h 822 m3/h
26
A i r p r epa r at i o n eq u i p m en t
2
Degree of filtration 0.01 µm
Working pressure 1.0 MPa (10 bar)
Operating temperature 5 to 45 °C
Bracket
For cleanroom versions, Part number For filter
BE30 AMC310
contact SMC.
BE50 AMC510
BE60 AMC610
For AMC810 and -910 there is no bracket.
Subject to changes
27
Ai r pr epar ation equip me nt
2 Medium
Max. working pressure
Secondary pressure
Operating temperature
Flow
Air
1.0 MPa (10 bar)
0.05–0.7 MPa (0.5–7.0 bar)
5 to 60 °C
ARM5: 200 ln/min; ARM10 & -11: 300 ln/min
Tillbehör
Part number Type
136134 Mounting bracket1 ARM10
136133 Panel nut1 ARM10
GC3-10A-X2101 Pressure gauge ARM10 (0–1 MPa)
G14-8-JA Pressure gauge ARM5 (0–0.8 MPa) ARM11 ARM5, manifold mounting
1. Panel nut required for bracket. manifold
mounting
For block-mounted regulators with individual, or common supply a complete catalog is needed to determine version.
Contact SMC.
XT13-207-F10 G1 1/4
XT13-202-F14 G1 1/2 1/4
XT13-283-F20 G2 1/4
28
A i r p r epa r at i o n eq u i p m en t
2
Medium Compressed air, lubricated or not lubricated
Degree of filtration 5 µm
Max. working pressure 0.8 MPa (8 bar)
Secondary 0.1–0.7 MPa 0.2–0.7 MPa 0.2–0.7 MPa
pressure (1–7 bar) (2–7 bar) (2–7 bar)
Operating temperature 5 to 60 °C
Max. flow 200 ln/min 200 ln/min 500 ln/min
■ Compact ■ Integrated push-in fitting (ARJ1020)
29
Ai r pr epar ation equip me nt
2
Medium Air
Degree of filtration 0.3 µm (microfilter) recommended
Working pressure 0.7 MPa (7 bar)
Operating temperature –5 to 60 °C
Flow 300 ln/min 600 ln/min 900 ln/min
Sensitivity 0.2% F.S.
Subject to changes
30
A i r p r epa r at i o n eq u i p m en t
2
Max. flow 150/250/400 ln/min 550/600/900 ln/min 3000/4000/5000 ln/min
Sensitivity 0.2% F.S.
For connection between old and current series of SMC’s modular FRL, please contact SMC.
Subject to changes
31
Ai r pr epar ation equip me nt
2 Type
Medium
Degree of filtration
Max. inlet pressure
ITV1030 ITV2030 ITV3030 ITV1050 ITV2050
Oil-free compressed air
5 µm (particle filter in combination with
microfilter is recommended)
1.0 MPa (10 bar)
ITV3050
ITV1000
32
A i r p r epa r at i o n eq u i p m en t
2
Medium Air1, degree of filtration min. 5 µm, oil-free air
Max. inlet pressure 0.2 MPa (2 bar) 1.1 MPa (10 bar)
Min. inlet pressure Secondary pressure +0.1 MPa
Max. flow 3.5 ln/min 6 ln/min 6 ln/min
Operating temperature 0 to 50 °C
Connection Single unit 4 mm (ramp 6 mm and 4 mm)
Monitor signal Analog 1–5 V
Vikt 100 g or less
1. If the medium contains large amounts of water, oil aerosols or compressor oil it can cause
malfunction. Contact SMC for selecting the appropriate filter.
33
Ai r pr epar ation equip me nt
AN – silencer
Medium Compressed air, lubricated or not lubricated
2
Max. working pressure 1.0 MPa (10 bar)
Operating temperature 5 to 60 °C
Silencer Silencer
Sintered bronze Push-in connection
Part number Silencing Conn. Flow Part number Silencing Conn. Flow
AN120-M3 11 dB (A) M3 0.07 m3/min AN10-C06 25 dB (A) 6 mm 0.8 m3/min
AN120-M5 18 dB (A) M5 0.27 m3/min AN15-C08 25 dB (A) 8 mm 1 m3/min
AN101-01 13 dB (A) R1/8 0.5 m3/min AN15-C08 30 dB (A) 8 mm 3 m3/min
AN110-01 21 dB (A) R1/8 0.5 m3/min AN20-C10 30 dB (A) 10 mm 5 m3/min
Standard AN30-C12 30 dB (A) 12 mm 5 m3/min
Part number Silencing Conn. Flow Large noise reduction effect
AN10-01 30 dB (A) R1/8 0.8 m3/min Part number Silencing Conn. Flow
AN20-02 30 dB (A) R1/4 3 m3/min ANB1-01 38 dB (A) R1/8 1.2 m3/min
AN30-03 30 dB (A) R3/8 5 m3/min ANB1-02 38 dB (A) R1/4 2.7 m3/min
AN40-04 30 dB (A) R1/2 8 m3/min ANB1-03 38 dB (A) R3/8 3.8 m3/min
AN500-06 30 dB (A) R3/4 12 m3/min ANB1-04 38 dB (A) R1/2 7 m3/min
AN600-10 30 dB (A) R1 20 m3/min ANB1-06 38 dB (A) R3/4 12 m3/min
AN700-12 30 dB (A) R1 1/4 30 m3/min ANB1-10 38 dB (A) R1 20 m3/min
AN800-14 30 dB (A) R1 1/2 50 m3/min ANB1-12 38 dB (A) R1 1/4 32 m3/min
AN900-20 30 dB (A) R2 80 m3/min ANB1-14 38 dB (A) R1 1/2 45 m3/min
Compact ANA1-01 40 dB (A) R1/8 0.8 m3/min
Part number Silencing Conn. Flow ANA1-02 40 dB (A) R1/4 1.2 m3/min
AN10-01 25 dB (A) R1/8 0.8 m3/min ANA1-03 40 dB (A) R3/8 2.7 m3/min
AN15-02 25 dB (A) R1/4 1 m3/min ANA1-04 40 dB (A) R1/2 4.5 m3/min
AN30-03 25 dB (A) R3/8 2 m3/min ANA1-06 40 dB (A) R3/4 7 m3/min
AN40-04 25 dB (A) R1/2 4 m3/min ANA1-10 40 dB (A) R1 12 m3/min
ANA1-12 40 dB (A) R1 1/4 20 m3/min
ANA1-14 40 dB (A) R1 1/2 32 m3/min
ANA1-20 40 dB (A) R2 45 m3/min
The above stated flow refers to recommended flow
at 0.5 MPa (5 bar).
Series 25 – silencer
Medium Air
Working pressure 1 MPa (10 bar)
Operating temperature 5 to 60 °C
Silencer series 25
Conn. Recommended Dimensions (mm)
Part number port R max. flow A B D
2504-002 1/4 2200 ln/min 62 30 24
2505-003 3/8 3000 ln/min 64 30 24
2506-004 1/2 4000 ln/min 68 30 24
2507-006 3/4 8000 ln/min 88.5 48 35 For metering silencer
2508-010 1 10000 ln/min 97.5 60 41 ASN, see chapter 3.
Subject to changes
34
A i r p r epa r at i o n eq u i p m en t
2
Medium Compressed air, not lubricated1
Degree of filtration Microfilter 0.03 µm (SMC’s AM or AFM series)
Connection G1/4 G3/8 G1/2
Inlet pressure 0.1–1 MPa (1–10 bar)
0.2–1.6 MPa
Secondary pressure 0.2–2 MPa (2–20 bar) 0.2–1 MPa (2–10 bar)
(2–16 bar)
Max. pressure boost 2:1 4:1
Flow 1:1 400 ln/min 100 ln/min 1000 ln/min 1900 ln/min 2300 ln/min
1. If components after the pressure booster require lubrication, lubricate after pressure booster.
Service set
Part number Fits
KT-VBA10A-1 VBA10A
KT-VBA11A-1
KT-VBA11A-20 VBA11A
KT-VBA20A-1 VBA20A
KT-VBA40A-1 VBA40A
KT-VBA43A-1 VBA43A
Function
Pressure booster VBA raises main line pressure to an
adjustable value. A built-in pressure regulator ensures
constant output pressure. The time for filling a tank with
increased pressure can be reduced by parallel operation
with non-return valve. Pressure booster is only activated
when tank pressure does not corresponds to main line Pilot operated and ATEX versions available on request.
pressure.
Subject to changes
35
Ai r pr epar ation equip me nt
2
Medium Compressed air
Max. working pressure 0.7 MPa (7 bar)
Operating temperature 0 till 40 °C
Ambient Indoors, 0 to 75% relative humidity
Min. bending radius 10 mm 20 mm 40 mm
Accessories 4 inner sleeves (supplied fitted in the tube)
Colour Transparent (changing to brown over time)
Suitable fittings KQ2, KJ
Materials Fluoropolymer
Subject to changes
36