MP801E Series Router
Installation Manual V2.1
Maipu Communication Technology Co., Ltd
No. 16, Jiuxing Avenue
Hi-Tech Park
Chengdu, Sichuan Province
P. R. China
610041
Tel: (86) 28-85148850, 85148041
Fax: (86) 28-85148948, 85148139
URL: http:// www.maipu.com
Mail:
[email protected]Maipu Confidential & Proprietary Information Page 1 of 44
MP800 Series Security Router Feature List
All rights reserved. Printed in the People’s Republic of China.
No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any
language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual
or otherwise without the prior written consent of Maipu Communication Technology Co., Ltd.
Maipu makes no representations or warranties with respect to this document contents and specifically disclaims any implied
warranties of merchantability or fitness for any specific purpose. Further, Maipu reserves the right to revise this document
and to make changes from time to time in its content without being obligated to notify any person of such revisions or
changes.
Maipu values and appreciates comments you may have concerning our products or this document. address comments to:
Maipu Communication Technology Co., Ltd
No. 16, Jiuxing Avenue, Hi-Tech Park
Chengdu, Sichuan Province
P. R. China
610041
Tel: (86) 28-85148850, 85148041
Fax: (86) 28-85148948, 85148139
URL: http:// www.maipu.com
Mail:
[email protected] All other products or services mentioned herein may be registered trademarks, trademarks, or service marks of their
respective manufacturers, companies, or organizations.
Document History
Date Revision No. Description
20/09/2007 R1.0 The MP801E Router Installation Manual provides technical information about
the 801E router designed and developed by Maipu Communication Technology
Co., Ltd
Maipu Confidential & Proprietary Information Page 2 of 44
MP800 Series Security Router Feature List
Maipu Feedback Form
Your opinion helps us improve the quality of our product documentation
and offer better services. Fax your comments and suggestions to (86) 28-
85148948, 85148139 or email to
[email protected].
Document Title MP801E ROUTER INSTALLATION MANUAL
Product Document 1.0
Version Revision
Number
Evaluate this Presentation:
document (Introductions, procedures, illustrations, completeness, arrangement, appearance)
Good
Fair
Average
Poor
Accessibility:
(Contents, index, headings, numbering)
Good
Fair
Average
Poor
Editorial:
(Language, vocabulary, readability, clarity, technical accuracy, content)
Good
Fair
Average
Poor
Your check suggestions to improve this document:
suggestions to
Improve introduction
Make more concise
improve the
Improve Contents
Add more step-by-step procedures/tutorials
document
Improve arrangement
Add more technical information
Include images
Make it less technical
Add more detail
Improve index
If you wish to be contacted, complete the following:
Name Company
Postcode Address
Telephone E-mail
Maipu Confidential & Proprietary Information Page 3 of 44
MP800 Series Security Router Feature List
Contents
About Installation Manual .........................................................................6
Purpose .................................................................................................................6
How to Get in Touch ...............................................................................................6
Customer Support...................................................................................................................6
Documentation Support...........................................................................................................6
Overview.....................................................................................................7
Hardware Features .................................................................................................8
MP801E Appearance................................................................................................................8
MP801E Front Panel................................................................................................9
MP801E Backboard Interface .................................................................................................10
MP801E Router System .........................................................................................................11
801E Functionality ................................................................................................ 12
MP801E Main Board.............................................................................................. 14
Modules.................................................................................................... 16
Sync/Async Serial Interface Module (SAE) Series..................................................... 17
1-port High-speed V.24/V.35 Serial Module (1SAE).................................................................17
Channelized E1 Module (CE1) ................................................................................ 18
1-port Channelized E1 Module (1CE1) ....................................................................................18
Non-channelized E1 (E1) Series ............................................................................. 19
1-port Non-channelized E1 (1E1) ...........................................................................................19
Frequency-band MODEM M336 Series .................................................................... 21
1-port 33.6K Frequency-band MODEM(1M336) ...............................................................................21
Base-band MODEM (M128) Series.......................................................................... 22
1-port 128K base-band MODEM (1M128)...............................................................................22
ISDN (U) Series.................................................................................................... 24
1-port ISDN U Module (1U)....................................................................................................24
IP Module (VOP/VOS) Series.................................................................................. 25
1-port IP Module (1VOP)........................................................................................................25
2-port IP Phone Module (2VOP) .............................................................................................26
1-port Switch IP Phone Module (1VOS) ..................................................................................27
2-port Switch IP Phone Module (2VOS) ..................................................................................29
Ethernet Module (ETE) Series ................................................................................ 30
1-port Ethernet Module (1ETE) ..............................................................................................30
Maipu Confidential & Proprietary Information Page 4 of 44
MP800 Series Security Router Feature List
ISDN S/T Module (ST) Series................................................................................. 31
1-port ISDN S/T Module (1ST)...............................................................................................31
System Installation ................................................................................. 32
Precautions .......................................................................................................... 32
Environment ........................................................................................................ 32
Operating Environment..........................................................................................................32
Temperature & Humidity .......................................................................................................33
Dust Prevention.....................................................................................................................33
Routers & Accessories ........................................................................................... 34
Chassis Installation ............................................................................................... 34
Tools & Equipment ................................................................................................................34
Machine Installation...............................................................................................................35
Connecting Power Supply ......................................................................................................35
Grounding Connection ...........................................................................................................36
Main Control Board Cable Connection.....................................................................................36
Console Port Connection ........................................................................................................36
Grounding Wire Connection ...................................................................................................37
Module Installation................................................................................................ 37
Rack/Desk ............................................................................................................................37
Panel Wire Connection...........................................................................................................37
Hardware Installation ............................................................................................................38
Interface Cable Connection.................................................................................... 39
1SAE Module Cable Connection..............................................................................................39
1CE1/1E1 Module Cable Connection.......................................................................................41
1M336 Module Cable Connection............................................................................................41
1M128 Module Cable Connection............................................................................................41
1U Module Cable Connection..................................................................................................41
1VOP/2VOP Module Cable Connection ....................................................................................42
1VOS/2VOS Module Cable Connection....................................................................................42
1ETE Module Cable Connection ..............................................................................................42
1ST Module Cable Connection................................................................................................42
Interface Cable Signals ........................................................................... 43
Ethernet Cable (Twisted-pair Interface RJ45) .......................................................... 43
Console Port Cable................................................................................................ 44
Maipu Confidential & Proprietary Information Page 5 of 44
MP800 Series Security Router Feature List
About Installation Manual
Purpose
The MP801E Router Installation Manual explains product features and
installation issues. Read the manual carefully before installing the product.
The manual provides all technical information you need to understand
about the installation. The document provides right answers to your
technical queries.
How to Get in Touch
The following sections provide information on how to obtain support for
the Maipu English documentation and Maipu products.
Customer Support
If you have problems or questions regarding your product, contact us by
e-mail at [email protected]. You can call our Overseas Business
Division over +86–28-85148850, 85148041, 85148050, 85148750, and
85148997.
Documentation Support
Maipu Communication Technology Co., Ltd welcomes comments and
suggestions on the document usefulness. For further queries or
suggestions, contact us by e-mail [email protected] or fax comments
to +86-28-85148948 or 85148139. You can visit our website at
http://www.maipu.com, which comprises interesting subjects such as
product knowledge base, sales & support, and the Maipu news.
Maipu Confidential & Proprietary Information Page 6 of 44
MP800 Series Security Router Feature List
Overview
MP801E router is a data communication product that can be widely applied
to finance, telecommunication, tax and security industries, and large-
medium-scale enterprises.
MP801E series modular router provides a set of high efficiency and low-
cost network connection solutions.
MP801E supports the following applications:
Computer network interconnection
Multi-service data integration
Branch institute dialup and dialup backup service
Internet and enterprise (Extranet) access
Maipu Confidential & Proprietary Information Page 7 of 44
MP800 Series Security Router Feature List
Hardware Features
MP801E Appearance
Maipu Confidential & Proprietary Information Page 8 of 44
MP800 Series Security Router Feature List
MP801E Front Panel
Following are the indicators on the panel:
SYS & PWR (system and power supply indicator):
SYS - system status indicator
Fast shining: Loading
Slow shining: Load successful
PWR (system power supply indicator)
On: After power on
SLOT1 (slot 1 status indicator)
ACT - voice card module data
RDY - slot has voice card module link status
SLOT 0 (slot 0 status indicator)
ACT - insert module data indicator
RDY – inserting module link status
CONSOLE (console port)
TXD – sending console port data
RXD – receiving console port data
FETH1 (Ethernet interface1)
100M - 10/100M Ethernet interface data rate indicator
On: 100M
Off: 10M
Maipu Confidential & Proprietary Information Page 9 of 44
MP800 Series Security Router Feature List
ACT - Ethernet interface data
FETH0 (Ethernet interface0):
100M - 10/100M Ethernet interface data rate indicator
On: 100M
Off: 10M
ACT - Ethernet interface data indicator
MP801E Backboard Interface
From left to right:
Interface Form Description Application
ON/OFF Power supply switch. Right is
OFF and left is ON.
INPUT AC 100-240 1A input
SLOT1 Bus slot VOP/VOS voice
module
SLOT0 Interface module Fast serial, bus slot MIM module
decides interface
form
SLOT1 - voice card module slot for VOP/VOS serial module
SLOT0 - MIM module slot, which adopts modular design
Maipu Confidential & Proprietary Information Page 10 of 44
MP800 Series Security Router Feature List
MP801E Router System
The following table explains MP801E router basic configuration and
working environment:
Item Description
Console port One fixed, async DTE working mode (RJ45)
Ethernet port Two fixed 10/100Mbps fast Ethernet port (RJ45)
Voice card slot One voice card SLOT1
MIM slot MIM module SLOT0 supporting kinds of slot module
Processor High performance PowerPC processor
FLASH 8MB
SDRAM 64MB
Dimension 340 × 230 × 44 (mm)
(W × D × H)
Power supply input AD: 100 – 240V - 50/60Hz
voltage DC: -40 ~ -57V
Optional AC, DC power supply. Confirm before shipment
Environment 0-40°C
temperature
Environment 10-90%. Non-condensing
humidity
Power supply rating 45W
power
Maximum power 15W
consumption
Maipu Confidential & Proprietary Information Page 11 of 44
MP800 Series Security Router Feature List
801E Functionality
The following table explains MP801E router functionality, and supported
protocols and services.
Protocols & services Description
Network protocol WAN supports:
PPP
PPP compression
SLIP
CSLIP protocol
Frame relay
Frame relay switch
X.25
X.25 switch
HDLC
LAPB
ISDN
LAN is Ethernet supporting two kinds of link layer frame
format:
Ethernet-II
Ethernet-SNAP
Dialup network MODEM dialup (call-in/call-out)
CALLBACK
Dial-on-demand
Dialup backup
Routing protocol Static routing
Dynamic routing:
RIPv1
RIPv2
OSPF
BGP
IRMP (compatible with CISCO EIGRP)
SNSP (compatible with CISCO ODR)
Dial-on-demand routing (DDR)
Policy routing
Multicast:
IGMP
PIM-SM
PIM-DM
DVMRP
Maipu Confidential & Proprietary Information Page 12 of 44
MP800 Series Security Router Feature List
Hot backup
VRRP
VBRP (compatible with CISCO HSRP)
Network service ARP
Proxy ARP
L2TP
Configure command-level protocol to guarantee
unauthenticated user not to intrude into router:
IP packet filter firewall
IP UNNUMBERED
IP policy routing
DHCP relay
PAP/CHAP validation
EASY IP
NAT network concealing
RADIUS validation
IPsec data encryption
IKE
GRE
Load balance
MPLS
QoS PQ
CQ
WFQ
CBWFQ
LLQ
WRED
CAR
Network management SNMPv1, SNMPv2, SNMPv3
Standard network management (compatible with CISCO)
Configuration via local console port
Local telnet login or remote login configuration
Configure command security isolation function
Provide Chinese/English prompt and help information
Debugging information
Login via telnet and manage other product
Download and upload configuration file and application
program via FTP
Download and upload configuration file and application
program via TFTP
Colorful level debugging information support
Support log function
Security IP packet filter firewall, PAP/CHAP, MD5, NAT, RADIUS,
TACACS and IPsec data encryption
Maipu Confidential & Proprietary Information Page 13 of 44
MP800 Series Security Router Feature List
MP801E Main Board
The MP801E router main board comprises three fixed interfaces, one voice
card slot, one MIM slot, six indicators and power supply jack and one fixed
interface. The MP801E router provides three fixed interfaces – one console
port, two Ethernet interfaces and their attributes:
Console port:
Attributes Description
Linker type RJ45
Interface standard RS232
BR 9600bps - 115200bps
Supported service Connects with character terminal
Connects with local PC serial and operates terminal emulation
program CLI
Ethernet interface:
Attributes Description
Linker type RJ45
Interface number 2
Supported frame format Ethernet_II
Ethernet_SNAP
IEEE 802.2
IEEE 802.3
Working mode 10M/100M adaptive
Full/half duplex
Supports auto-crossing
Supported network protocol IP
Maipu Confidential & Proprietary Information Page 14 of 44
MP800 Series Security Router Feature List
Slots:
The MP801E router has two slots - SLOT0 and SLOT1. SLOT0 comprises
MIM slots, which can be inserted into different modules. SLOT0 supports
the following modules:
Ethernet interface module
Sync/async interface module
Async interface module
E1/CE1 interface module
U interface module
ST interface module
Base-band MODEM module
Frequency-band MODEM module
VOP/VOS module
The modules are compatible with all functional modules of MP800, MP17XX
and MP26XX series routers.
SLOT1 is voice card slot used for VOP/VOS module, which can access the
phone in IP network via dialup or second dialup. The user makes free
phone calls in IP network.
Maipu Confidential & Proprietary Information Page 15 of 44
MP800 Series Security Router Feature List
Modules
MP801E is a modular router. It provides two slots. SLOT1 is voice card slot
for VOP and VOS serial voice module. SLOT0 is an MIM slot compatible
with all interface modules of Maipu routers.
Following are the modules:
1SAE
1CE1
1E1
1M336
1M128
1U
1VOP
2VOP
1VOS
2VOS
1ETE
1ST
Maipu Confidential & Proprietary Information Page 16 of 44
MP800 Series Security Router Feature List
Sync/Async Serial Interface
Module (SAE) Series
1-port High-speed V.24/V.35 Serial
Module (1SAE)
1SAE module is used for MP801E router. 1SAE completes 1-port
sync/async serial data flow -- receiving and sending. The port operates in
synchronous mode:
DCE mode: 2.048Mbps
DTE mode: 8 Mbps
The port in asynchronous mode operates 115.2Kbps. MP801E router
sync/async serial interface default working mode is sync. The sync serial
interface is in DTE or DCE mode. In DTE mode, it receives external DCE
clock such as external sync modem. In DCE mode, the router provides
clock. The V24/V35 mode switch functions via panel.
1SAE Interface Module
1-port high-speed V.24/V.35 serial module (1SAE)
Maipu Confidential & Proprietary Information Page 17 of 44
MP800 Series Security Router Feature List
1SAE Interface Module Connected Cable
1SAE interface cable is V35 DTE cable and V24 connected DTE cable.
1SAE Interface Attributes
11-port high-speed V.24/V.35 serial module (1SAE) attributes:
Attributes Description
Sync Async
Tie-in DB25-DB25 DB25-DB25
Interface standard & working V.24 V.35 EIA/TIA-232
mode DTE DTE
DCE DCE
Minimum baud rate (bps) 1200 1200 300
Maximum baud rate (bps) 128K 8M 115.2K
Supported protocol & service X25 Dialup
HDLC Backup
PPP HDLC
SLIP PPP
FR SLIP
LAPB
Channelized E1 Module (CE1)
1-port Channelized E1 Module (1CE1)
The 1-port channelized E1 module provides 1984K multi-timeslot data flow
receiving and sending and processing port. As CE1 interface, it divides slot
1-31 to different groups and each group timeslot after using binding as
one interface.
1CE1 Interfac e & Ind i cator
Maipu Confidential & Proprietary Information Page 18 of 44
MP800 Series Security Router Feature List
1-port channelized E1 (1CE1) indicator:
LOS On: Cannot check frame sync signal
Off: After sync
1 CE1 I nt er f ace Connect ed Cabl e
1CE1 and BNC pin coaxial cable and RJ45-RJ45 connected twisted-pair.
1 CE1 I nt er f ace At t r i but es
1-port Channelized E1 (1CE1) attributes:
Attributes Description
Interface BNC, RJ45 (can not be used together)
Interface number 1 group
Interface standard G.703
Supported protocol PPP
X.25
HDLC
FR
Non-channelized E1 (E1) Series
1-port Non-channelized E1 (1E1)
The 1-port non-channelized E1 module provides a data transmission port
with 2.048Mbit/s bandwidth. E1 is same as CE1. It can be divided into 32
timeslots, and timeslot 0 of E1 can be used to transmit data in unframed
mode to realize 2M transparent transmissions.
1 E1 I nt er f ace Modul e & I ndi cat or
1E1 interface module:
1-port non-channelized E1 (1E1)
Maipu Confidential & Proprietary Information Page 19 of 44
MP800 Series Security Router Feature List
1-port non-channelized E1 (1E1) indicator:
LOS On: Transparent 2M transmission
On: Non-transparent and cannot check frame sync signal
Off: After sync
1 E1 I nt er f ace Connect ed Cabl e
1E1 and BNC pin coaxial cable and RJ45-RJ45 connected twisted-pair.
1 E1 I nt er f ace At t r i but es
1-port non-channelized E1 (1E1) attributes:
Attributes Description
Interface BNC, RJ45 (cannot be used together)
Interface 1 group
number
Interface G.703
standard
Supported X.25
service FR
Supported PPP
protocol HDLC
Maipu Confidential & Proprietary Information Page 20 of 44
MP800 Series Security Router Feature List
Frequency-band MODEM M336
Series
1-port 33.6K Frequency-band MODEM(1M336)
1-port 33.6-K frequency-band MODEM works in sync or async mode.
1M336 Interface & Dialup DIP
1M336 interface module:
1-port 33.6K frequency-band MODEM (1M336)
DIP:
1-port 33.6K frequency-band MODEM (1M336) DIP:
Mode DIP switch Description
configuration
1 2
Frequency-band OFF OFF LINE port used as inbuilt frequency-band
MODEM mode MODEM interface
Console port mode ON OFF LINE port used as CONSOLE port. Configure
router via dialup remote login
1M336 Interface Module Connected Cable
1M336 module connected cable is RJ45 (4, 5 signal wire) or RJ11
telephone line.
Maipu Confidential & Proprietary Information Page 21 of 44
MP800 Series Security Router Feature List
1M336 Interface Attri butes
1-port 33.6K frequency-band MODEM (1M336) attributes:
Attributes Description
Tie-in RJ45
Interface number 1
Supported link PPP
protocol Frame relay
X.25
HDLC
Supported network IP
protocol
Base-band MODEM (M128)
Series
1-port 128K base-band MODEM (1M128)
1M128 Module, Indicator & D IP Switch
1M128 interface module:
1-port 128K base-band MODEM (1M128):
Maipu Confidential & Proprietary Information Page 22 of 44
MP800 Series Security Router Feature List
The 1-port 128K base-band MODEM (1M128) indicator:
ACT On: Link established
B1 B1 channel indicator
Light on: when using channel B1, and rate is 64K
B2 B2 channel indicator
Light on: when using channel B2, and the rate is 128K
DIP switch:
The 1-port 128K base-band MODEM (1M128) DIP:
Mode DIP switch configuration Description
1 2
Loopback ON Reservation
1M128 Module Connected C able
1M128 module connected cable is RJ45 (4, 5 signal cable) or RJ11 line.
1 M128 I nt er f ace At t r i but es
1M128 interface attributes:
1-port 128K base-band MODEM (1M128) interface:
Attributes Description
Tie-in RJ45
Interface number 1
Supported link PPP
protocol Frame relay
X.25
HDLC
Supported network IP
protocol
Maipu Confidential & Proprietary Information Page 23 of 44
MP800 Series Security Router Feature List
ISDN (U) Series
1-port ISDN U Module (1U)
1-port ISDN U module connects DDN network and ISDN network and not
to connect modem.
1U Module & Indicator
1U module:
1-port ISDN U module (1U):
1-port ISDN U module (1U) indicator:
ACT Light shines after link established
B1 channel indicator
B1
Light on: When using channel B1, and rate is 64K
B2 channel indicator
B2
Light on: When using channel B2, and the rate is 128K
1-port ISDN U module (1U) DIP switch:
Mode DIP switch configuration Description
1 2
Loopback ON Reservation
1U Module Connected Cable
1U module connected cable RJ45 (4, 5 signal cable) or RJ11 line.
Maipu Confidential & Proprietary Information Page 24 of 44
MP800 Series Security Router Feature List
1U Interface A ttributes
1-port ISDN U module (1U) interface attributes:
Attributes Description
Tie-in RJ45
Interface number 1
Supported link protocol PPP
Supported network IP
protocol
IP Module (VOP/VOS) Series
1-port IP Module (1VOP)
1-port IP phone module accesses any telephone via IP network. The user
makes free phone calls via IP network.
1VOP Module Indicator
1VOP interface module:
1-port IP phone module (1VOP):
1-port IP phone module (1VOP) indicator:
V1 IP phone module indicator, and the light is on during the call
V2 1VOP module may not have this light, and if it has, the light will be not on
1VOP Module Connected C able
1VOP module connected cable is RJ45 (4, 5 signal cable) and RJ11 line.
Maipu Confidential & Proprietary Information Page 25 of 44
MP800 Series Security Router Feature List
1VOP Interface Attributes
1-port IP phone module (1VOP) interface attributes:
Attributes Description
Interface RJ45 jack
Interface number 1
Supported H.225
protocol H.245
RTP
RTCP
G.711
G.723
G.729
2-port IP Phone Module (2VOP)
The 2-port IP phone module accesses any call in IP network via dialup.
The user makes free phone calls via IP network.
2VOP Module & Indi cator
2VOP module:
2-port IP phone module (2VOP)
The 16 2-port IP phone module (2VOP) indicator:
V1 IP phone module indicator
Light on: After pickup, during the call
V2 IP phone module indicator
Light on: After pickup, during the call
2 VOP Modul e Connect ed Cabl e
2VOP module connected cable is RJ45 external cable.
Maipu Confidential & Proprietary Information Page 26 of 44
MP800 Series Security Router Feature List
2 VOP Modul e I nt er f ace At t r i but es
2-port IP phone module (2VOP) interface attributes:
Attributes Description
Interface RJ45 jack (two RJ11 plugs)
Interface
2 RJ11
number
H.225
H.245
RTP
Supported
RTCP
protocol
G.711
G.723
G.729
1-port Switch IP Phone Module (1VOS)
The 1-port switch IP phone module accesses any phone in IP network via
dialup or second dialup. The user makes free phone call via IP network.
1VOS Module & Indi cator
1VOS module:
1-port switch IP phone module (1VOS)
1-port switch IP phone module (1VOS) indicator:
V1 IP phone module indicator.
Light on: During the phone call
V2 1VOS module may not have this indicator, or the lamp will never be on
Maipu Confidential & Proprietary Information Page 27 of 44
MP800 Series Security Router Feature List
1VOS Module Connected C able
1VOS module connected cable is RJ45 (4, 5 signal cable) and RJ11 line.
1VOS Interface Attributes
1-port switch IP phone module (1VOS) interface attributes:
Attributes Description
Interface RJ45 jack
Interface number 1
H.225
H.245
RTP
Supported
RTCP
protocol
G.711
G.723
G.729
Maipu Confidential & Proprietary Information Page 28 of 44
MP800 Series Security Router Feature List
2-port Switch IP Phone Module (2VOS)
The 2-port switch IP phone module accesses any phone in IP network via
dialup or second dialup. The user makes free phone calls via IP network.
2VOS Module & Indi cator
2-port switch IP phone module (2VOS):
2-port switch IP phone module (2VOS) indicator:
V1 IP phone module indicator
Lamp on: During the phone call
V2 IP phone module indicator
Lamp on: During the phone call
2VOS Module Connected C able
2VOS module connected is RJ45.
2VOS Module Interface Attri butes
2-port switch IP phone module (2VOS) interface attributes:
Attributes Description
Interface RJ45 jack
Interface number 2 (RJ11)
Supported protocol H.225
H.245
RTP
RTCP
G.711
G.723
G.729
Maipu Confidential & Proprietary Information Page 29 of 44
MP800 Series Security Router Feature List
Ethernet Module (ETE) Series
1-port Ethernet Module (1ETE)
1-port Ethernet module provides Ethernet connection.
1ETE Module & Indi cator
1ETE module:
1-port Ethernet module (1ETE)
1-port switch IP phone module (1ETE) indicator:
LINK On: Link connected
Tx Data sending lamp shining: Data sending
Rx Data receiving lamp shining: Data receiving
1ETE Module Connected C able
RJ45 twisted-pair.
1ETE Module Interface Attri butes
1-port Ethernet port (1ETE) attributes:
Attributes Description
Tie-in RJ45
Tie-in number 1
Supported protocol 802.3
Maipu Confidential & Proprietary Information Page 30 of 44
MP800 Series Security Router Feature List
ISDN S/T Module (ST) Series
1-port ISDN S/T Module (1ST)
1-port ISDN S/T module provides 64K or 128K high-speed access and
backup.
1ST Module & Indicator
1ST module:
1-port ISDN S/T module (ST) indicator:
ACT Activated indicator
On: Operating normally
B1 B1 channel indicator
On: Using channel B1 with a rate of B1=64K or B1+B2=128K
B2 B2 channel indicator
On: Using channel B2 with a rate of B2=64K or B1+B2=128K
1ST Module Connected Cable
1ST cable is RJ45 connected Ethernet cable.
1ST Module Interface Attributes
1-port ISDN S/T module (1ST) interface attributes:
Attributes Description
Plug RJ45
Plug number 1
Supported protocol PPP
Maipu Confidential & Proprietary Information Page 31 of 44
MP800 Series Security Router Feature List
System Installation
Precautions
Read this manual
Place MP801E on flat surface to avoid falling down
Do not put heavy material on MP801E
Use UPS system
Ensure proper grounding
Do not open chassis with power supply
Environment
Operating Environment
To ensure stable functioning of routers, maintain stable temperature and
humidity in the equipment room.
Environment temperature: 0~40°C
Humidity: 10~90%. Non-condensing
MP801E configures its fan, and the theory of radiation is: take out the cold
air from the left and radiate the hot air out from right via the fan. Around
the radiation hole, the space should be no less than 10cm. We suggest
installing router on 19-inch standard rack. Or we can place the router on
flat floor, and in the hot area, we suggest installing air-conditioning.
Maipu Confidential & Proprietary Information Page 32 of 44
MP800 Series Security Router Feature List
Temperature & Humidity
Temperature Relevant humidity
Long-term Short-term Long-term Short-term
15°C ~ 30°C 0°C ~40°C 40%~65% 10%~90%
Dust Prevention
Dust is harmful for the operation of MP801E. Maintain a clean and dust-
free atmosphere.
Maipu Confidential & Proprietary Information Page 33 of 44
MP800 Series Security Router Feature List
Routers & Accessories
Before installing router, check the router and accessories. Following is the
MP801E basic configuration equipment list:
Name Number Remarks
MP801E chassis 1 Router chassis
Power supply cable 1 220V/10A
Console port cable 1 RJ45-DB9 crossing cable
Ethernet cable 2 Connected Ethernet cable
Technical documents 1 Installation manual and CD
Product packaging 1 Includes foam anti-shock material, external
packing box and plastic bag
Chassis Installation
Tools & Equipment
Needed tools:
Screwdriver
Anti-static equipment
Connected cable:
Console port cable
Ethernet cable (MP801E Ethernet cable is configured according to the
number of Ethernet modules)
Modular interface cable
Needed equipment:
Ethernet 10 BASE-T HUB
Configuring terminal (can be PC)
Equipment relevant to optional module
Maipu Confidential & Proprietary Information Page 34 of 44
MP800 Series Security Router Feature List
Machine Installation
The dimensions of MP801E are 340mm x 230mm x 44mm (W×D×H).
Following is the installation process:
Step 1: Fix angle iron on the front panel or back panel sides with bolts
Step 2: Place router on empty slot
Step 3: Fix the angle iron to slots with bolts
Step 4: Fix the bracket and fixed angle iron over the rack
Connecting Power Supply
MP801E router adopts stable power supply switch system, and it has lower
requirement of AC.
AC power supply input: 100~240V, 50~60Hz
DC power supply input: -40 ~ -57V
Maximum power: 15W ± 10%
Use the below shown power supply jack or MIM PC power supply jack, and
ensure reliable grounding.
Power supply jack:
Ground wire
Naught wire Live wire
Connecting power supply:
Step 1: Switch off the power supply switch. Connect one side of power
supply cable to the entry of back panel of router, and another side to
power supply jack (AC: 220V 50Hz/60Hz. DC: -48V).
Step 2: Switch on the power supply.
Step 3: Check whether the power supply indicator front panel is on. If
it is not on, repeat step 1 and 2.
Maipu Confidential & Proprietary Information Page 35 of 44
MP800 Series Security Router Feature List
Grounding Connection
The grounding requirement of equipment with plastic chassis and without
grounding post:
Grounding mode should be in accordance with the united grounding
requirement of working place, protection place and anti-thunder
grounding.
Grounding cable section area: The grounding cable (section area is
according to maximum current load) should adopt (copper) lead, but
not naked lead. The united grounding resistance should be <5Ω.
Good power supply grounding
Main Control Board Cable Connection
The section explains the method of connecting MP801E router control
board cable to network including connecting router console port.
Console Port Connection
The MP801E router provides one EIA/TIA-232 async serial console port.
Via this port, the user configures the router by adopting RS-232 serial
character terminal (normally it is a PC).
Step 1: Find a character terminal. It can be standard terminal with
RS-232 serial or normal PC.
Step 2: Ensure that power supply is off for router or terminal. Connect
RS-232 serial and console port with cables.
Maipu Confidential & Proprietary Information Page 36 of 44
MP800 Series Security Router Feature List
Grounding Wire Connection
The MP801E grounding wire normal connection ensures protection against
thunder and anti-jamming.
Configure the power supply yawp filter at the input end of router power
supply. Connect the center with chassis. For external network connection,
such as E1 interface, the grounding cable protects PSTN.
Connect this point and ground using a thick cable with the resistance not
more than 4Ω. If the router is installed on 19-inch standard rack, ground
the rack well.
Module Installation
MP801E router adopts modular system structure and different kinds of
interface configuration. Following are the module installation steps:
Step 1: Choose the module and interface (relation of module and slot
refers to basic configuration and module configuration list).
Step 2: Insert module into slot. Insert the module circuit board into
interface card slot.
Step 3: Push in the module close to back panel
Step 4: Tighten the screw
Rack/Desk
If MP801E is placed onto 19-inch standard rack, use front-end installation
method. If MP801E is placed on desk, stick the formula.
Panel Wire Connection
Panel wire connection includes Ethernet interface cable, WAN sync/async
cable connection.
Maipu Confidential & Proprietary Information Page 37 of 44
MP800 Series Security Router Feature List
Hardware Installation
Step 1: Complete machine installation and ensure that the power
supply switch is off.
Step 2: Connect one side of AC power supply cable to entry side of
router power supply and other side to power supply jack.
Step 3: Configure the router via console port after first power on.
Step 4: Insert one side of configuration cable to console port and
other side to PC or terminal serial.
Step 5: Insert one side of Ethernet cable to LAN interface and other
side to LAN.
Step 6: Connect sync/async communication cable to router WAN
interface.
The MP801E sync/async interface works in the mode of V.24 or V.35.
The two modes are completed via V.24/V.35 button. In V.24 mode,
interface adopts standard RS232 cable connection.
In V.35 mode, interface adopts special V.35DTE cable connection.
V.35DTE cable:
Step 7: After completing the cable connection, open the power supply
switch for router configuration.
Maipu Confidential & Proprietary Information Page 38 of 44
MP800 Series Security Router Feature List
Interface Cable Connection
1SAE Module Cable Connection
This section explains 1SAE module and cable connection.
NOTE: Before connecting sync/async serial, ensure the following:
The equipment type connecting sync/async serial, which is sync/async,
DTE/DCE
Access equipment requires signal standard, baud rate and sync clock.
Sync/async serial usually accesses external Modem or TA (terminal
adapter) as dialup interface. Sync serial has two modes, which is DTE and
DCE. Router is used as DTE equipment.
DTE and DCE equipment:
Equipment type Interface type Typical equipment
DTE Pin type PC
Router
DCE Hole type MODEM
Multiplexer
CSU/DSU
Rate and transmission distance:
Sync/async serial supports different signal standards and baud rate in
different working modes. Choose cables according to prevailing actual
conditions. Signal maximum transmission distance and BR should be
relevant to cables.
Maipu Confidential & Proprietary Information Page 39 of 44
MP800 Series Security Router Feature List
V.24 cable rate and transmission distance:
BR (bps) Max. transmission distance (m)
2400 60
4800 60
9600 30
19200 30
38400 20
64000 20
115200 10
V.35 cable rate and transmission distance:
BR (bps) Max. transmission distance (m)
2400 1250
4800 625
9600 312
19200 156
38400 78
56000 60
64000 50
2048000 30
When adopting EIA/TIA-232 cable, BR rate should not be over 64Kbps.
1SAE Module Cable Connection
Connecting sync/async serial module cable:
Step 1: Insert one side of DB-25 to 1SAE module DB-25-interface and
then screw down fixed knob.
Step 2: Connect another DB25 interface to V.24-V.35 (DB-25, M-34)
cable and then connect to the following equipment: If WAN is DDN
line, connect (V.35 cable) to digital Modem V.35 interface.
If WAN is dialup line, connect (V.24 cable) to analog Modem serial.
Maipu Confidential & Proprietary Information Page 40 of 44
MP800 Series Security Router Feature List
1CE1/1E1 Module Cable Connection
Connect 1CE1/E1 interface according to the following steps:
Step 1: Connect one side of BNC plug to BNC interface of 1CE1/E1
module.
Step 2: Connect another side to the equipment. TX should be
connected with the RX equipment. RX should be connected with TX
line.
Step 3: After power on, check LOS status of 1CE1/E1 module. If
indicator is on, there is malfunction and signal loses sync, so check the
line.
Connect with RJ45-RJ45 twisted-pair if you are using RJ45 interface. BNC
and RJ45 cannot be used together.
1M336 Module Cable Connection
Insert RJ11 plug of 1M336 module cable to LINE jack.
1M128 Module Cable Connection
Step 1: Insert RJ11 plug of 1M336 module cable to LINE jack and
other side with external wire.
Step 2: After power on, check ACT status of 1M128 module. If the
indicator is not on, check the circuit.
1U Module Cable Connection
Step 1: Insert RJ11 plug of 1U module cable to LINE jack and another
side with external wire.
Step 2: After power on, check ACT status of 1U module. If the
indicator is not on, check the circuit.
Maipu Confidential & Proprietary Information Page 41 of 44
MP800 Series Security Router Feature List
1VOP/2VOP Module Cable Connection
Connecting VOP module cable:
Step 1: Insert telephone line to RJ11/RJ45 interface of 1VOP/2VOP
and another side to telephone.
Step 2: When having the phone call, pay attention to the indicator of
1VOP/2VOP card back panel. The indicator and Active light should be
on.
1VOS/2VOS Module Cable Connection
Connecting VOS module cable:
Step 1: Insert telephone line to RJ11/RJ45 interface of 1VOS/2VOS
and another side to small switch or external junction box.
Step 2: When having the phone call, pay attention to the indicator of
1VOS/2VOS card back panel. The indicator and Active light should be
on.
1ETE Module Cable Connection
Connecting 1ETE module cable:
Step 1: Insert RJ45 plug of 1ETE cable to RJ45 jack.
Step 2: Connect another side of RJ45 plug to relevant equipment wire.
1ST Module Cable Connection
Connecting 1ST module cable:
Step 1: Insert RJ45 plug of 1ST module cable to RJ45 jack.
Step 2: Connect another side of RJ45 plug to related equipment wire.
Maipu Confidential & Proprietary Information Page 42 of 44
MP800 Series Security Router Feature List
Interface Cable Signals
Ethernet Cable (Twisted-pair
Interface RJ45)
MP801E Ethernet interface cable is 8-core non-screen twisted-pair. Port1/2
is sending-end and port 3/6 is receiving-end. They are the same as
Ethernet card interface, which can be connected to HUB.
RJ45 direct connected cable (type-5 twisted-pair) connection relation:
RJ45 Signal Direction RJ45 Description Length
1 TX+ —> 1 Twisted-pair 1 2m
2 TX- —> 2
3 RX+ <— 3 Twisted-pair 2
6 RX- <— 6
4 --- --- 4 Twisted-pair 3
5 --- --- 5
7 --- --- 7 Twisted-pair 4
8 --- --- 8
RJ45 crossing connected cable (type-5 twisted-pair) connection relation:
RJ45 Signal Direction RJ45 Description Length
1 TX+ —> 3 Twisted-pair 1 2m
2 TX- —> 6
3 RX+ <— 1 Twisted-pair 2
6 RX- <— 2
4 --- --- 7 Twisted-pair 3
5 --- --- 8
7 --- --- 4 Twisted-pair 4
8 --- --- 5
Maipu Confidential & Proprietary Information Page 43 of 44
MP800 Series Security Router Feature List
Console Port Cable
MP801E console port cable connects with PC 9-core serial jack. It is 8-core
non-screen cable. One side is RJ45 plug and another side DB9 (hole).
A-3 console port cable connection relation:
RJ45 Signal Direction DB9 Length
1 CTS —> 8 3m
2 DSR —> 6
3 RXD —> 2
4 --- --- ---
5 GND --- 5
6 TXD <— 3
7 DTR <— 4
8 RTS <— 7
A.3 RM2-1E1 and RM2-1CE1 uses RJ45-RJ45 crossing twisted-pair
When using E1 card RJ45 interface, if required use RJ45-RJ45 crossing
twisted-pair.
A-4 E1 and CE1 using RJ45-RJ45 crossing twisted-pair
RJ45 Signal Direction RJ45
1 RX+ <— 4
2 RX- <— 5
3 --- --- 7
6 --- --- 8
4 TX+ —> 1
5 TX- —> 2
7 --- --- 3
8 --- --- 6
Maipu Confidential & Proprietary Information Page 44 of 44