The test report summarizes photometric and electrical testing of one LED area light model HPAL-NW200-BP9. Key results include: - Total lumen output of 21,814 lumens, total power of 191.3 watts, and luminous efficacy of 114.0 lumens per watt. - Correlated color temperature of 5,065K, color rendering index of 85.9, and color rendering index R9 of 22.1. - Testing was conducted in accordance with IESNA LM-79 using an integrating sphere to measure output and an LSI high speed mirror goniometer to measure distribution.

Uploaded by

flysch_uk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
119 views7 pages

545 E. Algonquin RD., Arlington Heights, IL 60005

The test report summarizes photometric and electrical testing of one LED area light model HPAL-NW200-BP9. Key results include: - Total lumen output of 21,814 lumens, total power of 191.3 watts, and luminous efficacy of 114.0 lumens per watt. - Correlated color temperature of 5,065K, color rendering index of 85.9, and color rendering index R9 of 22.1. - Testing was conducted in accordance with IESNA LM-79 using an integrating sphere to measure output and an LSI high speed mirror goniometer to measure distribution.

Uploaded by

flysch_uk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

.

REPORT
545 E. Algonquin Rd., Arlington Heights, IL 60005

Project No. G102748333 Date: January 25, 2017

REPORT NO. 102748333CHI-019

TEST OF ONE LED AREA LIGHT

MODEL NO. HPAL-NW200-BP9


LED MODEL NO. OSRAM GW PSLPS1.EC-KTLP-5H7I-1
DRIVER MODEL NO. SOSEN SS-180R-50

RENDERED TO

SUPER BRIGHT LEDS, INC.


4400 EARTH CITY EXPRESSWAY
SAINT LOUIS, MO 63045

TEST: Electrical and Photometric tests as required to the IESNA test standard.

AUTHORIZATION: The testing performed was authorized by signed quote number Qu-00723537-3.

STANDARDS USED: The following American National Standards or Illuminating Engineering Society of
North America Test Guides were used in part or totally to test each specimen:

IESNA LM-79 - 2008: Electrical and Photometric Measurements of Solid State Lighting

ANSI NEMA ANSLG C78.377: 2012: Specifications of the Chromaticity of Solid State Lighting Products

DESCRIPTION OF SAMPLE: The client submitted one production sample of model number HPAL-NW200-BP9.
The sample was received by Intertek on January 20, 2017, in undamaged
condition and one sample was tested as received. The sample designation was
AH01202017035722C.

DATES OF TESTS: January 23, 2017 through January 25, 2017.

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and
conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested
material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply
that the material, product, or service is or has ever been under an Intertek certification program.
SUMMARY

Model No.: HPAL-NW200-BP9


Description: LED Area Light

Criteria Result
Total Lumen Output (Lumens) 21814
Total Power (W) 191.3
Luminaire Efficacy (LPW) 114.0
Power Factor at 120Vac 0.998
Power Factor at 277Vac 0.936
Current ATHD % at 120Vac 4.19
Current ATHD % at 277Vac 12.64
Correlated Color Temperature (CCT - K) 5065
Color Rendering Index (CRI - Ra) 85.9
Color Rendering Index (CRI - R9) 22.1
DUV 0.001
Chromaticity Coordinate (x) 0.344
Chromaticity Coordinate (y) 0.354
Chromaticity Coordinate (u') 0.209
Chromaticity Coordinate (v') 0.486

EQUIPMENT LIST

Model Control Last Date Calibration Date


Equipment Used Number Number Calibrated Due Date Used
Yokogawa Power Meter WT210 146919 07/11/16 07/11/17 01/25/17
Omega Newport Thermometer DPI8-C24 146920 10/07/16 10/07/17 01/25/17
LSI High Speed Mirror Goniometer 6440T 146928 VBU VBU 01/25/17
Newport Thermohygrometer iServer 146956 01/06/17 01/06/18 01/25/17
Pacific, AC power supply 118-ACX CHI0358 VBU VBU 01/25/17
Labsphere Spectroradiometer CDS1100 CHI0091 VBU VBU 01/23/17
3 Meter Sphere SPR600 CHI0088 VBU VBU 01/23/17
Elgar AC Power Supply CW1251M 146112 VBU VBU 01/23/17
Sorenson DC Power Supply XFR150-8 146846 VBU VBU 01/23/17
Newport Humidity Recorder iTHX-SD 146382 06/27/16 06/27/17 01/23/17
Yokogawa Power Meter WT1600 146768 01/10/17 01/10/18 01/23/17
Fluke K/J Thermometer 52 146004 01/10/17 01/10/18 01/23/17

Report No. 102748333CHI-019 2 of 7 Date: January 25, 2017


TEST METHODS

Seasoning in Sample Orientation – LED Products

No seasoning was performed in accordance with IESNA LM-79.

Photometric and Electrical Measurements – Integrating Sphere Method


A Labsphere Model CDS 1100 CCD Array Spectroradiometer and Two Meter or Ten Foot Sphere was used
to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each
SSL unit.

Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the
client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to
stabilize for at least thirty minutes before measurements were made. Electrical measurements including
voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer.

The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of
Standards and Technology.

Photometric and Electrical Measurements – Distribution Method

A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at
each angle of distribution for each sample.

Ambient temperature was measured equal to the height of the sample mounted on the Goniometer
equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was
allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements
including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer.

Some graphics were created with Photometrics Plus software.

Report No. 102748333CHI-019 3 of 7 Date: January 25, 2017


RESULTS OF TEST

Photometric and Electrical Measurements at Ambient Temperature (25°C +/- 1°C) - Integrating Sphere Method

Input Input Input Input


Intertek Base Voltage Current Power Power Current
Sample No. Orientation {Vac} (mA) (Watts) Factor ATHD (%)
AH01202017035722C Up 120.0 1600 191.54 0.998 4.19
277.0 726.3 188.4 0.936 12.64

CIE 31’ CIE 31’ CIE 76’ CIE 76’


Correlated Color CRI CRI Chromaticity Chromaticity Chromaticity Chromaticity
Temperature (K) -Ra -R9 DUV Coordinate (x) Coordinate (y) Coordinate (u’) Coordinate (v’)
5065 85.9 22.1 0.001 0.344 0.354 0.209 0.486

Spectral Distribution over Visible Wavelengths

nm mW/nm nm mW/nm nm mW/nm nm mW/nm nm mW/nm


350 1.910 440 229.5 530 260.2 620 245.7 710 30.17
355 1.819 445 366.3 535 266.4 625 231.8 715 26.07
360 1.986 450 438.4 540 270.7 630 216.4 720 22.56
365 1.766 455 365.4 545 274.2 635 200.2 725 19.48
370 1.657 460 282.7 550 276.4 640 183.4 730 16.78
375 1.562 465 233.5 555 278.3 645 166.6 735 14.45
380 1.604 470 184.4 560 279.8 650 150.2 740 12.45
385 1.633 475 154.5 565 281.3 655 134.7 745 10.75
390 1.835 480 148.3 570 283.2 660 119.9 750 9.333
395 2.360 485 151.3 575 285.3 665 105.8 755 8.091
400 3.396 490 160.5 580 287.3 670 93.39 760 7.070
405 5.589 495 175.4 585 288.0 675 81.83 765 6.144
410 9.667 500 191.3 590 287.8 680 71.58 770 5.322
415 17.01 505 206.6 595 285.7 685 62.33 775 4.588
420 29.39 510 219.7 600 282.4 690 54.08 780 4.010
425 50.77 515 232.7 605 276.8 695 46.95
430 84.36 520 243.8 610 268.5 700 40.62
435 138.1 525 253.0 615 258.2 705 35.01

Spectral Data Over Visible Wavelengths

500.000
450.000
400.000
350.000
(mW/nm)

300.000
250.000
200.000
150.000
100.000
50.000
0.000
350 400 450 500 550 600 650 700 750 800
Nanometers

Report No. 102748333CHI-019 4 of 7 Date: January 25, 2017


RESULTS OF TEST (cont'd)

Photometric and Electrical Measurements at Ambient Temperature (25°C +/- 1°C) – Distribution Method

Input Input Input Input Absolute Lumen


Intertek Base Voltage Current Power Power Luminous Flux Efficacy
Sample No. Orientation {Vac} (mA) (Watts) Factor (Lumens) (LPW)
AH01202017035722C Up 120.1 1597 191.3 0.998 21814 114.0

Intensity (Candlepower) Summary at 25°C - Candelas

Angle 0 22.5 45 67.5 90 X


0 11717 11717 11717 11717 11717
5 11645 11610 11656 11655 11654
10 11466 11427 11472 11473 11464
15 11186 11194 11172 11178 11188
20 10788 10772 10752 10762 10764
25 10204 10163 10177 10174 10181
30 9442 9360 9398 9395 9401
35 8495 8446 8448 8438 8446
40 7369 7311 7301 7315 7310
45 6074 6020 6012 6011 6016
50 4561 4493 4468 4464 4455
55 2794 2759 2751 2745 2726
60 1042 992 1017 1048 1042
65 103 108 158 175 189
70 72 71 74 81 82
75 53 51 51 56 57
80 41 39 35 37 38
85 24 22 19 18 16
90 0 0 0 0 0

Report No. 102748333CHI-019 5 of 7 Date: January 25, 2017


RESULTS OF TEST (cont'd)

Illumination Plots

Mounting Height: 10 ft.


Illuminance - Cone of Light Isoillumination Plot

X X

Zonal Lumen Summary and Percentages at 25°C Zonal Lumens and Percentages at 25°C

Zone Lumens % Luminaire Zone Lumens % Luminaire


0-30 8998 41.2 0-10 1108 5.1
0-40 14317 65.6 10-20 3169 14.5
0-60 21422 98.2 20-30 4721 21.6
60-90 392.6 1.8 30-40 5319 24.4
0-90 21814 100.0 40-50 4638 21.3
90-180 0.0 0.0 50-60 2466 11.3
0-180 21814 100.0 60-70 312.6 1.4
70-80 60.5 0.3
80-90 19.5 0.1

Report No. 102748333CHI-019 6 of 7 Date: January 25, 2017


PICTURES (not to scale)

CONCLUSION

The results tabulated in this report are representative of the actual test samples submitted for this report only. The
data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not
determined in this report.

In Charge Of Tests: Report Reviewed By:

Jehue Williams Timothy Quigley


Associate Engineer Engineer
Lighting Division Lighting Division

Attachment: None

Report No. 102748333CHI-019 7 of 7 Date: January 25, 2017