Technical Announcement: Abstract

This document announces the release of a new version of DOPSoft software for DOP series HMIs. The update includes fixes for issues with uploading/downloading through CDC mode and alarm setting compilation errors. It also adds four new DOP-H model numbers to the software: DOP-H07E460, DOP-H07S460, DOP-H07E420 and DOP-H07S420.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views4 pages

Technical Announcement: Abstract

This document announces the release of a new version of DOPSoft software for DOP series HMIs. The update includes fixes for issues with uploading/downloading through CDC mode and alarm setting compilation errors. It also adds four new DOP-H model numbers to the software: DOP-H07E460, DOP-H07S460, DOP-H07E420 and DOP-H07S420.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Technical Announcement

IINDUSTRY AUTOMATION BU, DELTA ELECTRONICS, INC


General
Security Confidential
DOP-B Classification
Product Category DOP-HMI Model(s) Top-secret
Series
ECN No. N/A
HMI Issue No. HMI15061000
Daisy
Issued by PSM/FAE Author(s) Huang
Division Released Date 2015/06/10
HMI Product Manager, BU Sales Representative, DGC, DEU, DPR, DES,
Recipient
DEK, DEJ, DIN
Abstract:
Delta is pleased to announce the immediate release of new DOPSoft version 2.00.04.09 patch for DOP
series HMI. This release is an improvement, which includes new HMI model and bug fixes.
 DOP-H models after updating firmware are 3.0091.
Description:
1. The model(s): DOP series
2. Fixes in DOPSoft version 2.00.04.09:
2.1 Fixed when upload/download HMI through CDC mode will cause error message “ No
Response From HMI! ”.
2.2 Fixed compile will show incorrect error message when address of Alarm Setting is not
specified.
3. Add in DOPSoft version 2.00.04.09:
3.1 Add DOP-H series HMI model: DOP-H07E460, DOP-H07S460, DOP-H07E420 and
DOP-H07S420.

品質至上 QUALITY
信賴第一 RELIABLITY
Page 1/4
追求卓越 EXCELLENT
1. Fixed when upload/download HMI through CDC mode will cause error message “ No Response From
HMI! ”.
Step 1. Into【Options】【Configuration】【Others】, set USB Download to CDC.

Or Into System Menu 【System Setting】【MISC.】,set USBCommMode to 2.

Step 2. Into 【Options】【Environment】,set Upload/Download to USB.

品質至上 QUALITY
信賴第一 RELIABLITY
Page 2/4
追求卓越 EXCELLENT
Step 3.Execute Download/Upload function from DopSoft: 【Download All Data】, 【Upload all Data】,
【Download Screen】, 【Upload Recipe】, 【Download Recipe】, 【Download Logic Data】, 【Upload Logic
Data】, 【Download Boot Screen】, 【Reset default logo】, 【Firmware update】, 【Get Firmware Information】,
【Reset HMI】.

Before:
DopSoft will pop up error message “ No Response From HMI! ”.
After:
DopSoft will execute Download/Upload.

2. Fixed compile will show wrong error message when address of Alarm Setting is not specified.
Step 1.Create an Alarm History Table at screen, and doesn’t specified address for Alarm Setting.
Step 2.Execute 【Tools】【Rebuild All】.

Before:
Output window will show incorrect message “Memory not enough in Panel SDRAM!” after compile.

After:
Output window will show correct message “Using alarm element must enable alarm function”.

品質至上 QUALITY
信賴第一 RELIABLITY
Page 3/4
追求卓越 EXCELLENT
3. Add DOP-H series HMI model: DOP-H07E460, DOP-H07S460, DOP-H07E420 and DOP-H07S420.
Add DOP-H series model menu.

品質至上 QUALITY
信賴第一 RELIABLITY
Page 4/4
追求卓越 EXCELLENT