Data Sheet 2BH7 520: Side Channel Blower

This document provides performance curve data and specifications for the G-BH7 Side Channel Blower. It includes curves showing the blower's suction capacity, power consumption, and temperature rise over a range of vacuum and pressure differences. The blower can operate as both a vacuum pump and compressor continuously over its performance range. It has IP55 protection and insulation class F. It is approved to UL and CSA standards. Technical data includes voltage ranges, current, power, maximum pressures, sound levels, and weight for 50Hz and 60Hz models.

Uploaded by

ahmet yavuz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
162 views2 pages

Data Sheet 2BH7 520: Side Channel Blower

This document provides performance curve data and specifications for the G-BH7 Side Channel Blower. It includes curves showing the blower's suction capacity, power consumption, and temperature rise over a range of vacuum and pressure differences. The blower can operate as both a vacuum pump and compressor continuously over its performance range. It has IP55 protection and insulation class F. It is approved to UL and CSA standards. Technical data includes voltage ranges, current, power, maximum pressures, sound levels, and weight for 50Hz and 60Hz models.

Uploaded by

ahmet yavuz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

G-BH7

Data sheet 2BH7 520


Side channel blower

Performance curves

Vacuum operation Compressor operation

180
50 Hz 50 Hz
150 60 Hz 60 Hz

120
Suction capacity V [m³/h]

1
90
… 2
60
1 1
2
30
2 1 2
0
600 450 300 150 000 250 500 750 1000

Vacuum Total pressure difference ∆p [mbar] Pressure


6,0

5,0 2

4,0

2 1 2
3,0 1
Power consumption P
at pump shaft [kW]

2,0 2 1 1

1,0

0,0
600 450 300 150 000 250 500 750 1000

Vacuum Total pressure difference ∆p [mbar] Pressure


150
2
120 2
1
2
90 2
1
Temperature rise ∆T

1
60
of conveyed air [K]

30

0
600 450 300 150 000 250 500 750 1000

Vacuum Total pressure difference ∆p [mbar] Pressure

The performance curves are based on air at a temperature of 15 °C and an Every G-BH pump can be used both as vacuum pump and compressor in
atmospheric pressure of 1013 mbar with a tolerance of ± 10 %. The total continuous operation over the total performance curve range. The motors
pressure differences are valid for suction and ambient temperature up to are available as standard in protection category IP 55 and insulation
25 °C. For other conditions please get in touch wit h us. class F. The vacuum pumps / compressors are UL and CSA approved.

 Gardner Denver Deutschland GmbH Technical data sheet - Edition 11/2009


Selection and ordering data
Type 2BH7 520
No. Fre- Rated Max. differential Sound Gewicht Order No.
quency 1) pressure ca.
pressure
2)
Voltage Current Power Vacuum Pressure level
Hz V A kW mbar dB(A) kg
3~ 50/60 Hz, IP55, Insulation material class F, UL 507 and CSA 22.2 No 113 (certificate number E225239)
50 200 - 240 Δ / 345 - 415 Y 9.7 Δ / 5.6 Y 2.20 -470 460 64
1 40 2BH7520-0AH26-8
60 220 - 275 Δ / 380 - 480 Y 10.3 Δ / 6.0 Y 2.55 -500 450 70
50 345 - 415 Δ 8.1 Δ 4.0 -500 820 65
2 52 2BH7520-0AH77-8
60 380 - 480 Δ 8.6 Δ 4.6 -530 810 71
3~ 50/60 Hz, IP55, Insulation material class F, UL 507 and CSA 22.2 No 113 (certificate number E225239)
50 500 Δ Δ 2.20 -470 460 64
1 40 2BH7520-0AC25-8
60 575 Δ Δ 2.55 -500 450 70
50 500 Δ 7.50 Δ 4.0 -500 820 65
2 52 2BH7520-0AC75-8
60 575 Δ 7.70 Δ 4.6 -530 810 71

1) Relief valves available for limiting differential pressure.

2) Measuring surface sound pressure level acc. to EN ISO 3744, measured with an equivalent unit at a distance of 1 m. The pump is throttled to an average suction pressure, with
piping connected, but no relief valves fitted, tolerance ±3 dB (A).

All G-BH fulfil the 2006/42/EC (machinery) and 2006/95/EC (low voltage) directives and the EN 60034-1 norm “Rotating electrical machines”.

The motors comply with EN 60 034-1 / -2 / -30 (IEC 60034) and thermal class F.
For three phase motors tolerances are +/-10% for fixed voltage motors and +/-5% for voltage range motors. Single phase machines are designed with a +/- 5% tolerance.
The frequency tolerance is +/- 2 % maximum.

Other voltages
86 Hz 100 Hz
50 Hz 50 Hz voltage range 60 Hz voltage range 2BH7…-.. □ . □
(5000 rpm) (6000 rpm)
3~
----- 185 - 225 V Δ / 320 - 390 V Y 200 - 240 V Δ / 345 - 415 V Y ----- 400 V Δ H 1
----- 200 - 240 V Δ / 345 - 415 V Y 220 - 275 V Δ / 380 - 480 V Y 380 V Δ ----- H 6
----- 345 - 415 V Δ 380 - 480 V Δ ----- ----- H 7
----- 500 V Δ 575 V Δ ----- ----- C 5
4)
3~ IE2 /
200 V Δ / 345 V Y 180 - 240 V Δ / 310 - 415 V Y 200 - 275 V Δ / 345 - 480 V Y ----- 400 V Δ P 1
500 V Y 450 - 550 V Y 520 - 600 V Y ----- ----- P 3
500 V Δ 450 - 550 V Δ 520 - 600 V Δ ----- ----- P 5
230 V Δ / 400 V Y 200 - 260 V Δ / 350 - 450 V Y 230 - 290 V Δ / 400 - 500 V Y 400 V Δ ----- P 6
400 V Δ / 690 V Y 350 - 450 V Δ / 610 - 725 V Y 400 - 500 V Δ / 690 - 725 V Y ----- ----- P 7

4) Performance can differ if high effiiciency motors are used. Please refer to corresponding data sheets.

Changes in particular of the quoted performance curve, data and weights may occur without prior notice. The data given do not constitute an obligation from our side to deliver as shown.

Gardner Denver Schopfheim GmbH Gardner Denver Deutschland GmbH


Elmo Rietschle is a brand of Gardner Roggenbachstraße 58 Industriestraße 26
Denver's Industrial Products Group 79650 Schopfheim - Germany 97616 Bad Neustadt - Germany
and part of Blower Operations
[email protected] Tel.: +49 7622 392-0 Tel.: +49 9771 6888-0
www.gd-elmorietschle.com Fax: +49 7622 392-300 Fax: +49 9771 6888-4000

You might also like