HD4070

THC Calibration
when Replacing the
Plasma Interface Board
Kit 128519

Kit Instructions
IM-384
(P/N 803840)

Revision 0 - April 2000

Hypertherm, Inc.
Hanover, NH USA
http://www.hypertherm.com
email: [email protected]

© Copyright 2000 Hypertherm, Inc.


All Rights Reserved

Hypertherm and Command THC are trademarks of Hypertherm, Inc. and may be
registered in the United States and/or other countries.
Hypertherm Offices Worldwide:

Hypertherm, Inc.
Etna Road, P.O. Box 5010
Hanover, NH 03755 USA
Tel.: (603) 643-3441 (Main Office)
Fax: (603) 643-5352 (All Departments)
Tel.: (800) 643-9878 (Technical Service – toll-free in USA and Canada)
Tel.: (800) 737-2978 (Customer Service – toll-free in USA and Canada)
email: [email protected] (General Information)
email: [email protected] (Technical/Customer Services)

Hypertherm Plasmatechnik GmbH


Technologiepark Hanau
Rodenbacher Chaussee 6
D–63457 Hanau-Wolfgang, Germany
Tel.: 49 6181 58 2100
Fax: 49 6181 58 2134

Hypertherm (S) Pte Ltd


No. 19 Kaki Bukit Road 2
K.B. Warehouse Complex
Singapore 417847
Tel.: 65 841 2489
Fax: 65 841 2490

Hypertherm UK Ltd
9 Berkeley Court, Manor Park
Runcorn, Cheshire, England WA7 1TQ
Tel.: 44 1928 579 074
Fax: 44 1928 579 604

France
15 Impasse des Rosiers
95610 Eragny, France
Tel.: 33 1 30 37 15 28
Fax: 33 1 30 37 15 79

Hypertherm S.r.L.
Via Torino 2
20123 Milan, Italy
Tel.: 39 02 725 46 312 (Customer Service)
Tel.: 39 02 725 46 314 (Technical Service)
Fax: 39 02 725 46 400 (All Departments)

Hypertherm B.V.
Burg, Haverkampstraat 13
7091 CN Dinxperlo, The Netherlands
Tel.: 31 315 655 866 (Customer Service)
Fax: 31 315 655 886

European Technical Support Organization (ETSO)


Edisonstraat 12
3281 NC Numansdorp, The Netherlands
Tel.: +800 4973 7843 (+800 Hypertherm) – (toll-free Technical Service)
Tel.: 31 186 659494
Fax: 31 186 659495

Japan
Shinjuku Park Tower
30th Floor
3-7-1 Nishi-Shinjuku
Shinjuku-ku, Tokyo
163-1030, Japan
Tel.: 81 03 5326 3142
Fax: 81 03 5326 3001

3/00
THC Calibration when Replacing the Plasma Interface Board

In This Bulletin:

128407 KIT CONTENTS ........................................................................................................... Page 2


PURPOSE ................................................................................................................................. Page 2
REQUIREMENTS ..................................................................................................................... Page 3
Tools Needed ......................................................................................................................... Page 3
PROCEDURE ........................................................................................................................... Page 4

IMPORTANT
If your HD4070 is not equipped with a Command THC,
these calibration procedures are not required.

128519 Kit Instructions Page 1


THC Calibration when Replacing the Plasma Interface Board

128519 KIT CONTENTS


041616 Plasma Interface PC Board

803840 Instructions

PURPOSE
After installing the replacement plasma interface PC board included with this kit, calibration of the THC
system is required. These instructions provide calibration procedures.

If your HD4070 is not equipped with a Command THC, these calibration procedures are not required.

128519 Kit Instructions Page 2


THC Calibration when Replacing the Plasma Interface Board

REQUIREMENTS

WARNING
ELECTRIC SHOCK CAN KILL
• Turn off the power supply before removing any access cover. If the power supply
is directly connected to a line disconnect box, switch the line disconnect to OFF
(O). In the U.S., use a "lock-out / tag-out" procedure until the service or
maintenance work is complete. In other countries, follow appropriate national or
local safety procedures.
• Do not touch live electrical parts! If power is required for servicing, use extreme
caution when working near live electrical circuits. Dangerous voltages exist inside
the power supply that can cause serious injury or death.
STATIC ELECTRICITY CAN DAMAGE CIRCUIT BOARDS
• Put on a grounded wrist strap BEFORE handling PC boards.

Tools Needed

#2 Phillips Screw Driver

Digital Volt Meter Small, Flat Screw Driver

128519 Kit Instructions Page 3


THC Calibration when Replacing the Plasma Interface Board

PROCEDURE
1. Turn off the power to the power supply.

2. Install the replacement plasma interface board in to the power supply and attach all electrical
connections.

3 Attach the volt meter to measure the arc voltage between power supply I/O board bus bars as shown
below.

Set volt meter to


measure 100-500 VDC.
THC.108

128519 Kit Instructions Page 4


THC Calibration when Replacing the Plasma Interface Board

4. Turn on the power to the power supply.

5. Put the Command THC in MANUAL MODE.

6. For 2-torch systems, select torch #1.

7. Begin a cutting process and compare the voltage displayed on the volt meter to the arc voltage
displayed on the CNC or on the power supply display.

8 Adjust the potentiometer on the torch #1 THC control board so that the voltage displayed on the volt
meter is the same as the arc voltage displayed on the CNC or on the power supply display.

9 For 2-torch systems, select torch #2 and begin a cutting process.


Adjust the potentiometer on the torch #2 THC control board so that the voltage displayed on the volt
meter is the same as the arc voltage displayed on the CNC or on the power supply display.

Torch #2
THC Control
PC Board
Torch #1
THC Control
PC Board

THC.107

10. Turn off the power to the power supply.

11. Remove the volt meter from the power supply.

12. Replace the access covers to the power supply.

128519 Kit Instructions Page 5