0% found this document useful (0 votes)
93 views9 pages

RW Prob 2017 CIVIL

The document provides design guidelines and calculations for a cantilever retaining wall. It determines dimensions such as a base width of 3.4m and stem thicknesses of 0.2m and 0.4m at the top and bottom. Vertical and lateral forces on the wall are calculated. Stability is checked against overturning, sliding, and bearing capacity. Reinforcement is designed for the stem and base to resist bending and shear stresses based on calculated moments and shear forces.

Uploaded by

Farah Mujahid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views9 pages

RW Prob 2017 CIVIL

The document provides design guidelines and calculations for a cantilever retaining wall. It determines dimensions such as a base width of 3.4m and stem thicknesses of 0.2m and 0.4m at the top and bottom. Vertical and lateral forces on the wall are calculated. Stability is checked against overturning, sliding, and bearing capacity. Reinforcement is designed for the stem and base to resist bending and shear stresses based on calculated moments and shear forces.

Uploaded by

Farah Mujahid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

DESIGN OF RETAINING WALL SESSION 2017 CIVIL :

Cantilever RETAINIG WALL TYPE

Dimensions of R.W

Given is height

You have to decide all other dimensions;

B = ½ - 2/3 of the height

Lh > Lt

Tbase = h/10 – h/12

Tstem at top = lesser [Min 200 mm]

Tstem at bottom = Hstem/10 – hstem/14

Base on these guidelines

Stem at top = 0.2 m

Stem thickness at bottom = 0.4

Base width B = 3.4 m

Lh = 2 m

Lt = 1m

Tbase = 0.45

Vertical Forces

WEIGHTS---------------------------------------N

1. Central Stem= ϒc t stem height –


24000 x 0.2 x 6.0 = 28800.0 N

2 Front Stem Taper = 1/2 x 24000 x 0.0 x 6.0 = 0.0

3 Back Stem Taper=1/2 x 24000 x 0.2 x 6.0 = 14400.0 N


4 Base Slab=24000 x 3.4 x 0.45 = 36720.0

5 Key=24000 x 0.0 x 0.0 = 0.0 [no key]

6 Back Fill= ϒs x LH X hbf = 17600 x 2.0 x 5.5 = 193600.0

7 Taper Back Fill=0.5x17600 x 0.2 x 5.5= 9680.0

8 Front Fill=17600 x 1.0 x 1.3 = 22880.0

9 Surcharge= s x Lh = 3000 x 2.0 = 6000.0

---------------------------------------------------

Total (Without Surcharge) V = 306080.0 [for stability checks]

(With Surcharge) V = 312080.0

Lateral Forces

Pressure Forces-------------------------------------------N
1−sin(𝜙)
Ca= 1+sin(𝜙) = 0.31

Cp = 1/Ca = 3.25

1 Active Earth Pressure H1= ½ Ca ϒs x h2 = 0.50 x 0.31 x 17600 x 5.95^2= 95723.9

2 Surcharge Lateral Pressure H2 = ca s h = 0.31 x 3000 x 5.95 = 5484.6

3 Passive Earth Pressure H3= ½ Cp ϒs x h12 = 0.50 x 3.25 x 17600 x 1.75^2= 87711.2

STABILITY OF RETAINING WALL

FOS against OT

Overturning Moment=H(i)xY(i) N-m

1 H1 X Y1 = 95723.9 x 1.983= 189853

2 H2 X Y2 = 5484.6 x 2.975= 16317

-------------------------

MOT = 206169 N-m


Restoring Moment=W(i) x X(i) N-m

1 VC1 x X1 = 28800.0 x 1.100= 31680

2 .0 x 1.000= 0

3 14400.0 x 1.267= 18240

4 36720.0 x 1.700= 62424

5 .0 x 0.000= 0

6 193600.0 x 2.400= 464640

7 9680.0 x 1.333= 12907

8 22880.0 x 0.500= 11440

Surcharge force is ignored

--------------------------

MR = 601331

F.O.S. vs Overturning= MR/MOT = 601331/206169=2.92 > 2

Satisfied against overturning

========================================

Safety vs Sliding

----------------

Note: Sliding is Critical When No Surcharge Acts on Heel

Sliding Force = AEP Force + surcharge force = 95724+5485= 101209 N


Resisting Force= PEP Force + α (Sum of Vertical forces without surchange) =

87711+ 0.45 x 306080= 225447 N

FOS vs Sliding= 225447/101209= 2.23 > 1.5

Satisfied against sliding

Bearing check

Bearing should be checked for both cases , with surcharge & without surcharge

Without surcharge

X= (MR -MOT)/V = (601331-206169)/306080= 1.291 m

P=V = 306080 N 1

e = B/2 – X = 3.4/2 – 1.291

M= V x e = 306080x(1.700-1.291)=125174 N-m B

Area ; A=B x1 = 3.40 m2

Section modulus Z= I/Y = 3.40^2/6=1.93 m3

q1,2 = P / A ± M / Z

y2 = pH=25054 N/m2

y1 = pT=154993 N/m2

Safety vs Bearing y1 y2

The check for bearing may be apply here

First is [without surcharge]

FOS vs Bearing= ABC/Max Bearing pressure = 180000/154993=1.16

Safe for bearing without surcharge


Safety vs Bearing [2nd , with surcharge]

-----------------

Note: Bearing may be Critical When Surcharge Acts on Heel

X= (601331+6000.0x2.400-206169)/312080.0=1.312 m

P=312080.0 N

M=312080.0x(1.700-1.312)=120974 N-m

A=3.40 m2

Z=3.40^2/6=1.93 m3

p=P/A±M/Z

pH=28999 N/m2

pT=154578 N/m2

qa net = 180 kPa

FOS vs Bearing=180000/154578= 1.16

Bearing was Critical When NO SURCHARGE Acted on Heel

====================================================

Strength Design of Retaining wall

Moments and Shears in Wall Elements

Moments in N-m and Shears in N

-----------------------------------

Stem Shear=1.6x(81792.22x(5.189/5.500)^2

+5069.77x(5.189 / 5.500))= 131893

Stem Moment=1.6x(81792.22x1.833+5069.77x2.750)=

= 278620
Heel Shear= 1.6x6000+1.2x193600+1.2x21600= 311480 N

Heel Moment= 311480x 2.00/2= 311480 N-m

(Toe Stresses)

Pressure Under Toe=154993

Pressure at 1.0 From Toe= 116776

Shear at Junction=1.6x77496+1.6x58388-0.9x10800=221283

Shear at Critical Section= 221283+0.9x150x0.45x0.158

-1.6x116776x0.158=189861

Toe Moment= 1.6x77496x0.667+1.6x58388x0.333-0.9x10800x0.5=116056

------------------------------------------------------------

==== Design for Stem Steels ====

Shear at Critical Section= 131893

Shear Capacity of Section= .1666667x0.75xSQR(20)x1000x 300.73=190528

Shear Check for Stem OK

== Vertical Steels for Stem ==

Earth Side BF side [due to maximum moment in stem]=2647.66 Sq mm/m; Min 75 mm


Cover
Exposed Side [ as per ACI criteria]= 0.5x0.0015x 1000x300.0= 225.00 Sq mm/m; Min 50
mm Cover

== Horizontal Steels for Stem [ ACI criteria] =

= 0.5x0.0025x1000x300.0=375.00 Sq mm/m on Each Face

==== Design for Steels in Base Slab ====

Shear Capacity of Section= .1666667x0.75xSQR(20)x1000x361.1= 228776

Ciritical Shear in Base= 311480 [larger shear out of heel and toe shear]

*** Shear Failure: Revise the Section Depth

Provided d for Base=361.1

Required d = Vmax/0.75 x1/6 xSQR(fc’) b=

=311480/( .1666667x0.75xSQR(20))x1000=491.64

Added d for Shear=130.54

== Main Steel for Heel (Top Face) = due to maximum moment in heel ==

1753.30 Sq mm/m; Min 75 mm Cover

== Main Steel for Toe (Bottom Face) = due to max moment in Toe==

Designed on Minimum Steel Ratio (Beam)

1203.67 Sq mm/m; Min 75 mm Cover


== Distribution Steel in Base Slab [ACI min slab steel] ==

= 0.0018x1000x450.0 = 810.00 Sq mm/m on Each Face