YMC2

Water-cooled magnetic centrifugal chiller


Cooling capacities from 800 kW to 3600 kW
At Eurovent Standard Conditions this equipment meets A Class energy efficiency levels.

Compatible range

Features
Our most advanced water-cooled chiller offers the following benefits: Low sound levels
Advanced technology results in sound levels as low as 75dBA.
Enhanced efficiency
Achieved through application of active magnetic bearing technology with Superior reliability
variable speed drive. Use of active magnetic bearing technology removes friction and the need
for oil resulting in a quieter and more reliable chiller.
Enhanced sustainability
Achieved by leak free refrigerant design, lower refrigerant charge and
falling film evaporator.
Photo courtesy of the LTCM lab of the Ecole
Polytechnique Fédérale de Lausanne, Switzerland

A falling-film evaporator is more efficient because refrigerant is sprayed over the To eliminate mechanical-contact losses in the driveline, the YMC2 chiller utilises a
tubes, offering improved heat transfer and reducing refrigerant charge by 30%. permanent-magnet motor and active magnetic-bearing technology.

64
YORK® AIR-CONDITIONING PRODUCTS

Water-cooled magnetic centrifugal chiller


YMC2 S0800AA to S3600AB

Nominal capacity (*)


YMC2 S0800AA S1000AA S1200AB S1400AA S1600AB S1800AB S2000AB
Cooling capacity (kW) 800 1000 1200 1400 1600 1800 2000
EER 6.06 6.13 6.32 6.33 6.31 6.07 6
SEER 7.58 7.83 7.92 8.34 8.59 7.83 8.16
ŋs, c 295 305 309 326 335 305 318
Sound pressure at 1 m (dBA) 77 77 76 76 77 79 80

YMC2 S2200AB S2400AB S2600AB S2800AB S3000AB S3200AB S3400AB S3600AB


Cooling capacity (kW) 2200 2400 2600 2800 3000 3200 3400 3600
EER 6.2 6.25 6.1 6.15 6.2 6.2 6.1 6.1
Sound pressure at 1 m (dBA) 81 82 82 82 82 82 83 83
Cooling Capacity at Eurovent Conditions, entering/leaving chilled water temperature 12°C/7°C, entering/leaving condenser water temperature 30°C/35°C
(*) YMC2 is a tailor and tune chiller. Its peformance will be factory-adjusted to match the exact site requirements based on the specific project operating.
The table above shows only a representative sample of performance points based on generic project operating conditions working with R134a refrigerant.
For R513a information contact your JCI Representative.
The above data is based on Johnson Control’s selection software YORKworks 18.06. Please refer to the latest version of the software for specific projects.

Technical data
YMC2 S0800AA S1000AA S1200AB S1400AA S1600AB S1800AB S2000AB
Length mm 3048 4267
Dimensions Width mm 1880 2007
Height mm 2410 2499 2573
Shipping weight (kg) 5171 5810 6579 7809
Refrigerant charge (kg) 278 280 423 454 445 612 656

YMC2 S2200AB S2400AB S2600AB S2800AB S3000AB S3200AB S3400AB S3600AB


Length mm 5154 5054
Dimensions Width mm 2007 2235
Height mm 2573 2656
Shipping weight (kg) 10095 10161 10255 10432 11500 11669 12048 12254
Refrigerant charge (kg) 667 666 658 647 766 760 750 750
1. All dimensions are approximate. Certified dimensions are available on request.
2. Refrigerant charge quantity and shipping weights will vary based on tube count.
3. Shipping weights are based on fully assembled and charged units.
4. Refer to product drawings for detailed weight information.

Superior sound reduction OptiView control centre


A-Weighted sound pressure level (dBA (re: 20µPa))
Measured in accordance with AHRI-575

Competitor

YORK® YMC2
5 dBA*

% Chiller full load The OptiView control centre provides complete diagnostics
to speed troubleshooting.
The YMC chiller is so much quieter than competitive magnetic-bearing chillers,
2

it sounds about half as loud. *Note: each segment on the Y axis = 5 dBA.

Manufacturer reserves the rights to change specifications without prior notice.

65