0% found this document useful (0 votes)
234 views36 pages

YDM3109plus MANUAL (EN) 171101 (Out) ISL 1213 05

Pdf manual for yale lock

Uploaded by

E C
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
234 views36 pages

YDM3109plus MANUAL (EN) 171101 (Out) ISL 1213 05

Pdf manual for yale lock

Uploaded by

E C
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 36
Digital Door Lock User Guide YDM3109+ © Bluetooth’ PLEASE READ INSTRUCTIONS BEFORE USE. The functions and design of this product can be changed without prior notice for performance and quality improvement. —be INTRODUCTION Thank you for choosing a Yale Digital Lock. The new Yale Digital Lock uses the latest technology to make life so much easier. This user manual enables you to operate the product safely and to its full potential Be sure to read this completely before using the Yale Digital Lock product Unlock your life! rrewortstowrieiok | Yale CONTENTS = Safety Precautions Product Features Components Overview Specifications Identification Quick Menu (Normal mode) Creating User Pin code Quick Menu (advanced mode) Configuration Normal mode User Code registration | User Card Key registration ene How to Use Emergency Power Change the Master code Register and delete User code Register and delete Card key Register and delete Onetime code Delete All Credentials Lock Setting Register and delete Remote control Register and delete Controller Unlocking Door with Code Unlocking Door with Card Key Locking the door Unlocking the door from the inside Safe Handle Setting (Open Door with fake Code Extemal Forced Lock | Internal Forced Lock ‘Automatic/ Manual Lock | Volume Break-in Alarm | 3-minute Lock Out Feature | Lost card key Emergency mechanical key override | Product malfunction Resetting Lock to Factory Default Emergency power supply for discharged batteries Power supply 15 16 a 18 19 20 a 2 2B 24 24 25 26 27 28 29 30 32 32 33 3 05 06 07 10 10 1B 15 24 33 —be ny ch Safety Precautions Do not install the digital door Donotattemptto disassemble Do not use water and any type of lock in an outdoor the digital door lock by your solvent to clean the product such environment self. By doing so, you may get as gasoline or benzene as they an electronic shock and can cause damage to electronic damage the product, circuit, deterioration and or paint oi. “Oo: Make sure to lock the door Do not use force with a tool Please keep your Code tight when you go out. onto the product. safely, ) : o] 2? : 1 Be careful not to hit the For total peace of mind, please Immediate re-registration of handle as it may cause store your back up key ina safe all remaining keys is required injuries. & convenient place after the to invalidate the lost key. door instalation is complete, oy ao A, Caution Make sure to follow the above instructions to avoid any injuries or damages on the properties. —be = Product Features @ Alarmed Door Lock Yale Digital door lock has a builtin damage alarm. I the keypad atea is damaged an alarm will sound, Proximity card identification You can use your ISO 14443 A type RFID card such as credit catd or pass card as your card key. Electronic Code System You can open the door conveniently with Code. Yale Digital door lock gives you the freedom and convenience of key-free. Emergency power back up 9V battery source is available if your batteries run out. Fake Code To prevent the Code being exposed Yale Digital door lock allows you to enter decoy numbers before or after entering your Code. Auto Locking The handle automatically disengages on the outside once you have entered your home, preventing anyone from following you. Remote control System (optional) Use a Remote control to unlock/Lock your door “remotely” & Zwave / Zigbee (optionay Use them to connect with Controller. BLE (optional) Use it to pair with Smartphone. am Components Overview Ee Cad The contents ofthis product may be subject to change without notice for performance or quality improvernent. > Basic Contents Front (Front Body) Back (Main Body) —_Installation Template Lock case Card Keys - AAABattries Users Guide > Optional Accessory - Remote controller - Remote control module ~Zwave module - Zigbee module = BLEmodule ny = Specifications Parts Specifications Remarks Front (Front Body) 68,6(W) x 306.6(H) x 27(D)(70.6)mm, Zinc die-casting 72.8(W) x 306.6(H) x 37.0(0)(80.8)mm, Operating temperature 15-55 (5-131 'F) dq Back (Main Boey) | Fiame-Retardant ABS, Zinc D/C Lever Zinc die-casting Card Key fea Upto 40 Keys Pay CGpeainvaoe 25-6) (oties até Lock case Steel and SUSA30 Remote Control Zwave Zabee Wicks Optional ah BLE module ¥ Battery life may vary depending on temperature, moisture levels, frequency of use and the quality of the batteries. x Please make sure that ll pats are included when purchasing the product. X Optional products may not be available depending on your country or local dealer. Packaging of this product can be recycled. & & WEEE Note: Waste electial products shoul not be Cenoeed of with household waste, Please recyte wher fanilics ens. (Check yur lel ahonty or eae for recyelng acc. ce Yale —be | = Identification iene sole\%§ (Front Body, Installation on the outside of the door) IRE ‘9V Emergency battey (Sok separate) $4 $ e °° Lock case Latch Bolt Automatic Locking Sensor Dead Bolt Keypad{i0-Key) Card Key Reader Dead Bolt Jam Lamp Battery Change Lamp Lever Reset button Emergency Power Supply Termnal 8| 6/6|O|O\9/9/O/O/O/O\o Emergency Key | = Identification ET sfte14) (Main Body, installation on the inside of the door) Battery Cover @Registraton button Lever Manual thumb turn Intemal Forced Lock Switch 1.5V AA Alkaline Batteries (4EA) Slot for Remote control module (Option) Volume Control Switch ‘Auto / Manual Lock button 6/O/O|/ B/O|O/S\O\O/o Safe handle button 10 Quick Menu Quick Menu Icon Touch the keypad with palm to Enter Master Code(4~ 10digits). begin and end actions. Click the indicated number, Enter User Code(4~10digits) Pross [ ¥] button on the keypad, Enter Visitor Code(Only Aciits) Enter Onetime Code Press [ #t] button on the keypad. (Oni acigts) Press @(Revistaionbutton inside of the battery cover. Enter User Card Key. (Up to 40ea) User Slot Number should be 2 digits. Repeat operation using settings indicated, Creating User Pin code Creating a user pin code must be performed upon Installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successtully completed. BG) cos irons 10-OyOn eGo FB Compict Enter New User Code. Press (I) button Quick Menu lick Menu (Normal mode) BLD vi cose esietont-10)-on) one arose Fone orn ic + EEE ed GI) user code Normal mode PEED )NE] ‘aoa- es Register 3} — (Gee 3-69 continue Deets 4 continue | UG compete [Complete |Complete G9 _ Emo Oa) O= 0300s) tom Q uick Menu eit 1 M1 changethe fees Pad eu # ic Credentials 2", 8D im Y ECTS eiens Gs Continue [Complete 13 PEED )NE] —— ‘Oa. EO " 84 o-s Oe EJ ones | controler NED = =) EC conics LG oot EPs cine | Gconpte compte Configuration TEWEINSIE User Code Registration KCEA0K 3) O-OQecw Registration(4 ~10} - Only One User Code Bi comiete =a] . Il: , (Ee Pross (D button. Enter New User Code. Press (B button to complete, User Card Key Registration (U2. =)) CRS x cert KeyResistation Upto toca ey) (EM comolte a) . el - Re Press (D button Contac all Card Keys Press (D button youwishto register on to complete. Card Key reader one by one A Caution + Make sure to leave the door open when registering User Code and Card Keys because you may accidentally lock the door while trying to register or change a credential + The previously registered User Code will automaticaly be deleted when a new credentials regstered. + iis recommended to change User Code on a regulr basis + Itisimpossible to make same number for Master code /Vistor code /Onetime code/User code. —be Configuration —— ECS Mind Change the Master cod A ", . 29 2 > . 23 > SQL) > | RREH HE Sc) ei eS Enter the Master Press () button. Enter [1], [4#] buttons Enter New Master Code Code, to change the Master and [ #¢] button, cole eWay ee sc 8 Kayo Again enter the Press [34] button Press (D button Master Code and to continue. ‘to complete. [44] button. = Configuration Advanced mode Register User Code =) 7 aN 7 esi 9 |p es Enter the Master Press (B) button, Enter{2], [44] buttons. Enter[ 7], [14] buttons Code, to register User code, efile) e fon FRE Enter the Enter the Press [«] button Press (D button User number (01-30) User Code (4-10 digits) to continue. to complete, and [] button, and [#2] button. De Ure MED Ce EEE) meee oe a) 30 oe a) complete HSITDSN3 —— Configuration Register Card "2 SED =o G6 Oe O= } [Complete Cems Mullen all> REN foa cf) foe: Enter the Master Press (B) button Enter[ 3], [44] buttons. Enter[ 7], [14] buttons Code. to register Card. 2 2a M2 a 1) ffl all] =i] = fon FRE Enter the Contact Card Key Press [3] button Press (D) button User number (01-40) youwishtoregisteron to continue. to complete. and [ #4] button. Card Key reader and [#2] button. complete £ Cees él] » = =|lOa:]/+\[fe: Enter the Master Press () button. Enter[4],[2#] buttons, Enter [ 7], [ ##] buttons Code. eof) = [2 flor FRE Enter Onetime Code Press [3] button Press (D) button (digits) to continue. to complete. and [#2] button. HSITDNA —— Configuration Cael eta Delete All Credentials = " vse BEB ene me 1 SH le Sale ee: Enter the Master Press (D button. Enter[S], [tt] buttons. Enter the Master Code Code. and [ #2] buttons, 23 fl FRE Press [%¢] button Press (B) button ‘to continue. to complete. 20 OSE USM eer Staats) M y y PIN EE ED terse New User Complete DOBRO Os7:0'O," OD. O ‘eel = | FRREH + fs eS] + [Fe : Enter the Master Press (button, Enter[6], [44] buttons. Enter[ 7], [#] buttons Code. ‘to change to Normal mode. certo pee Enter the New Again enter the Press (D button User Code and User Code to complete. [44] button. 21 PEND )NE] —— ‘oa| yon controller Press button rd 36 | - 7 7 ” 3 Enter the Master Press (f) button. Enter [ 8], [ #] buttons. Enter 1], [ #4] buttons Code. to register Remote control “onl > “© ay |i]< & S]}) or | is Enter the Press registration buttonon Press [¥] button Press ( button User Number Remote controller followed — to continue. to complete. (01~05) and by press [ $4] button to [8] button, complete after beep sound from digital door lock. De etre reeled) ec Dekte QB ot -05 Conclcd | —— Configuration GT ime rell g SH a 3 ECTS Mier >a? “~ =H | > |i, > Enter the Master Press (1) button. Enter [S],[ 4] buttons. Enter [ 1], [ #4] buttons Code, to register controller Yale | > ||f° & 5|}/ or | [See “ % Register Controller followed Press |] button Press (button bypress[#]buttonto to continue, to complete. complete after beep sound ‘rom digital door lock Delete Controller 23 PEND )NE] 24 —— How to Use Normal mode Cele eta Unlocking Door with Cod “fp > ills ancl] > © |} | OR | feo, a 7 Sy is Yt Ss ( Touch the keypad of Enter the registered Touch the keypad of Enter the [¢] button, the Front Body with Code on the ‘the Front Body with your palm. keypad. your palm. PU i resem VU eg Contac registered Card Key. Check if the door opens! ke Make sure to examine ifthe door opens normally with the registered User Code after the registration is complete —be > Please check Automatic / Manual Lock Mode > Automatic Lock Mode (Default Setting) Outside Inside 5 dlc 9 Ee} WithinS ||.» Within 5 » seconds c seconds | i) ‘When set on automatic lock mode, the automatic lock sensor detects the door dosing and locks the door automatically within 5 seconds, car > Manual Lock Mode Outside Inside The door locks when touching the keypad with the palm, Use Thumb tum knob on the main body. A, Caution + As the automatic lock function does not workin manual lock mode, make sure to check that the door is securely locked when leaving the premises 25 —be —— | How to Use uC Advanced Unlocking the door from thi Ri Safe Handle Setting isnot fixed as a default. > To Open Door when the safe handle button is released. Keep pushing the safe handle button. And then, press and open the door. The safe handle button is found on the inner handle 8 (Closed) (Open) >To Open Door when the safe handle button is fixed. ny Press the inner handle and open the door. 8 (Closed) (Open) A. Important + Make sure to ful familiarize yourself withthe operation of the Safe Handle in preparation for emergencies. 26 —be How to Use —— Normal mode ECS ier Safe Handle Setting The technology to prevent a forced attempt to drill a hole in the door and } To Release Safe Handle Setting Open the battery cover and take out a hex wrench. Keep pressing the Safe Handle button. ‘Turn the set bolt found in next to the handle to Close side, } To Set Safe Handle Open the battery cover and take out a hex wrench. ‘Turn the set bol found in next to the handle to Open side untl the Safe Handle button comes out. E] Note th - Be careful that the fing screw is not separated during the safe handle setting, —be a7 28 How to Use —— Normal mode Opening Door with fake Code (Only Normal mode) Tiss an extra security measure to prevent your Code being accidentally exposed. Itis only availabe for your User and Visitor Code ; not for use with the Onetime Code. > > Touch the keypad Method @ Press [ ] button to confirm. of the Front Body Enter the "Ea ‘or Touch the keypad with with your palm. Method @ palm to confirm Enter the -ESn —— How to Use When External Forced Lock mode is activated the Alarm will go off if someone press the handle to exit the property. > Extemal Forced Lock Setting - CARD Gua Advanced mode Contact Card Key on [Card Key reader for 7as 5 seconds untl you hear 3 beeps 7 (al > External Forced Lock Setting - User Code (Except Onetime Code) \ Touch the keypad of Enter registered Enter [#2]button for 5 seconds. the Front Body with User Code on the (The beep sound sets off your palm. keypad. for 3 times) Sr keds aco reas When intemal forced lack mode is activated the keypad is not functioning vncee ‘A warning beep sound will go of if anyone attempts to access using Code or the Card Key from outside I Note - Ifyou open a door withthe handle from insde in External Forced Lock, the alarm will sound, - Deactivate External Forced Lock by entering User Code or touching Card Key reader with registered Card Key. - intemal Forced Lock is only activated when door is closed 29 —be —— How to Use Normal mode eer Cue Automatic / Manual Lock Default Automatic lock ‘Automatic Lock Setting T+) Main body Automatic¢Manual Lock button released to set Auto Manual Lock Setting aq) Main body AutornatioNanual Lock button pressed to set Manual Default High o12 Co« The operation sound volume will be adjusted according to the Volume Switch Setting, (2: High / 1: Low/0 : Mute) E] Note - Even though the operation sound is set to ‘Mute’, the error and alarm will sound. 30 ny —be —— How to Use Normal mode Gece ae Break-in Alarm : When the front body is seperated from « SY ) the door, the damage alarm wil sound, To tum off Alarm Method @ Enter the regstered Code. ae | Method @ Press the interior @ button for 5 seconds. Method @ Touch the registered Card Key. — I eer tea During the 3-minute Lock Out mode, the lock will shut down and not allow operation. After five(5) unsuccessful atternpts at entering a valid code or Card key, 3-minute Lock Out mode is activated. To Release 3-minute Lock Out Method @ Press button, Method @ Depress inside lever handle Lov IF you lose your card, rest of card keys must ¢ be re-registered to invalidate missing one. {It’s only valid in Normal mode) Lost card key Re-registering card key FE] Note _ Enter the Code in case you lose the card key or you are not canying it. X Iisa users labily to break the lock because the user did not reister any Code. —h— 31 HSIIDNA 32 —— How to Use Normal mode Eero ie ile eM me ttl* | Operate the lock with the mechanical key when there isa problem with the lock ¥ Such as Pull down the Location of Forgotten User Code emergency } key hole ~ Electronic malfunction cover Labial ced) Press reset button located in the left of [emergency power terminal] with a pin and try again with the key or the security code. If it still does not work, call for after-sales service. Reset Burton Resetting Lock to Factory Default ‘When lock is reset to factory defaults all user codes {including the Master Code*) are deleted and all programming features are reset to original default settings (see below). 1. Remove the battery cover and batteries. 2, Remove the interior escutcheon to access the reset pads 3. The reset pads are located on bottom of the PCB board (Gee image) 4, While pressing the reset pads with tweezer, reinstall batteries and release reset pads with tweezer. 5. Replace battery cover. Upon reset, the Master Code creation is the only option available and must be performed prior to any other programming of the lock Reset Button ny —be Emergency Power Emergency power supply for discharged batteri In case the batteries are dead, you can open the door by using 9V battery as shown, >To supply emergency power “ae | -Ed- i, ae Place the 9V battery Touchthe keypad with Enter the regstered Code Touch the keypad with ‘onto the emergency your palm. on the keypad, palm or Press [3] button power supply terminal to.confirm and replace the batteries, Lease Ng Expiry period ‘The product uses four 1.5V alkaline AA batteries. ‘They may sustain 1 year if used 10 times a day. (Users are advised to use authentic alkaline batteries.) One-on-one real-life size 1.56) akaline AA battery Low battery alarm You must replace all 4 batteries n the following cases: * The Low Battery LED on key pad flickers red * When low battery notification message is played. FISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING ‘TO THE NATIONAL CODE OR RECYCLING PROGRAM FF) Note +The battery lif varies according to ambient temperature, humidity, the frequency of use, and the qualty of the battery + Do not use rechargeable batteries. Only alkaline batteries are recommended —be PEEPISE) ASSAABLOY ‘An ASSA ABLOY Group brand 1SL-1213-05 Ver3

You might also like