OVI+R is a capacitive voltage indicator used to determine the presence or absence of voltage in medium voltage equipment according to IEC 61243-5 standards. It has 4 connection leads, an LCD display, change-over contacts for status monitoring, and requires no auxiliary power for voltage detection. Its technical parameters include an operating temperature range of -25°C to +55°C, a threshold voltage range of 10% to 45%Un, and contact outputs of 5A at 250VAC or 30VDC.

Uploaded by

costas costas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
239 views

Ovi R

OVI+R is a capacitive voltage indicator used to determine the presence or absence of voltage in medium voltage equipment according to IEC 61243-5 standards. It has 4 connection leads, an LCD display, change-over contacts for status monitoring, and requires no auxiliary power for voltage detection. Its technical parameters include an operating temperature range of -25°C to +55°C, a threshold voltage range of 10% to 45%Un, and contact outputs of 5A at 250VAC or 30VDC.

Uploaded by

costas costas
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

OVI+R LRM Capacitive Voltage Indicator

OVI+R is used for


determination of voltage
presence and absence in
Medium Voltage equipment
according to IEC 61243-5
standard.

Features
IEC 61243-5 compliant 4 connection leads for measuring at front panel
LRM type Wide auxiliary input range (24-230V AC/DC)
Easy for installation and maintenance Change-over contacts for status monitoring
No auxiliary power is needed for voltage detection 1 LED indicator for power

3 Phase LCD display

Technical Parameters

Rated Frequency Protection Class


50Hz or 60Hz IP42

Threshold Voltage Connection Leads


10% to 45%Un 4.8 x 0.8mm faston term

Operating Temperature Dimension


-25°C to +55°C 96 x 50 x 42mm

Storage Temperature Cutting Size


-30°C to 80°C 92 x 45mm

Contact output Aux. Power Isolation


5A, 250VAC or 30VDC 1.5kV DC

Auxiliary power Power consumption


24 – 230V AC/DC Less than 2W
Technical Drawings
36,30
96

OVI+S

47,30

44,70
50

Connection Diagram
Test Points

1 - NO1
2 - COM
3 - NC
4 - Vaux(24-23OV AC/DC)
5 - GND

Logic

Capacitor Bank LCD Display

L1 L2 L3

Phase Connections

Contact Status
Contact Status
M.Codes
Vaux Status Phase Voltage

Type 1 Type 2

2 2
Off For Any Status 2 2
1 1

2 2
On All Phases < %10Un 2 2
1 1

At Least One Phase 2 2


On 2 2
> %45Un 1 1

Required data for order


Capacitance of coupling electrode C1 Cable type and length Rated voltage Un