0% found this document useful (0 votes)
107 views2 pages

06-Mx, My, N Member

This document summarizes the design of two steel beams: 1. Beam SB-1 is a compact HEB 450 section that satisfies checks for normal stresses, shear stresses, and the combined stress ratio. 2. Beam SB-2 is a built-up section that is also compact. It satisfies checks for normal stresses except it has lateral-torsional buckling of the compressed flange within limits. Both beams meet design requirements.

Uploaded by

MazenMowafy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
107 views2 pages

06-Mx, My, N Member

This document summarizes the design of two steel beams: 1. Beam SB-1 is a compact HEB 450 section that satisfies checks for normal stresses, shear stresses, and the combined stress ratio. 2. Beam SB-2 is a built-up section that is also compact. It satisfies checks for normal stresses except it has lateral-torsional buckling of the compressed flange within limits. Both beams meet design requirements.

Uploaded by

MazenMowafy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

ECG Project Name

Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


SEC. BEAM ID :- ( SB-1 ) Refrences
Steel grade St.37 ECP
Fy = 2.40 t/cm2 P (2)
1)- APPLIED FORCES :- Case Fu = 3.60 t/cm2 P (2)
Mx = 49.80 mt a
My = 0.00 mt
N = 18.00 t
Q = 0.00 t
2)- CHOISE OF SECTION :-

The section is Rolled section HEB 450


bFL = 300.0 mm
tFL = 26.0 mm
h = 450.0 mm
tWEB = 14.0 mm

3)- BEAM COLUMN DATA :-


Lin = 13.80 m Kin = 1.00
Lout = 3.00 m Kout = 1.00
Lu of compressin flg = 3.00 m
4)- CHECK SECTION :-
PROPERTIES OF SECTION :-
Y = 22.50 cm
A = 218.00 cm2
Ix = 79890.00 cm4
Iy = 11720.00 cm3
Sx = 3550.00 cm3
Sy = 781.00 cm3
rx = 19.10 cm
ry = 7.33 cm
CHECK COMPACTNESS :-
dw/tw = 24.571 Web is Compact table(2.1a)
C/tf = 4.462 Flange is Compact table(2.1c)
The sec is Compact

CHECK NORMAL STRESSES :-


Cb = 1.30 table(2.2)
( 20.bf ) / (√ fy ) = 3.873 m ECP 16
Lumax = 3.873 m
( 1380.Af ) / ( fy.d ) x Cb = 12.96 m eqn. 2.18
Lateral torsional buckling of comp.flange There is no LTB
lin = 72.251 < 180 SAFE
lout = 40.928 < 180 SAFE
lmax = 72.251
ALLOWABLE STRESS :-
Fbcx = 1.536 t/cm2
Fbcy = 1.728 t/cm2
Fca = 1.061 t/cm2
ACTUAL STRESS :-
fbcx = 1.403 t/cm2
fbcy = 0.000 t/cm2
fca = 0.083 t/cm2

A1 = 1.00 Cmx = 0.85


A2 = 1.00 Cmy = 1.00

( fca / Fc ) + ( fbcx / Fbcx ) A1 +( fbcy / Fbcy ) A2 = 0.99 t/cm2 < 1.00 SAFE

CHECK SHEAR STRESSES :-


qw = 0.00 t/cm2 < 0.840 SAFE eqn. 2.2
ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


SEC. BEAM ID :- ( SB-1 ) Refrences
Steel grade St.37 ECP
Fy = 2.40 t/cm2 P (2)
Fu = 3.60 t/cm2 P (2)
1)- APPLIED FORCES :- Case Combination
Mx = 18.00 mt a
My = 0.00 mt
N = 20.00 t
Q = 0.00 t
2)- CHOISE OF SECTION :-

The section is Built up section


bFLU = 280.00 mm The Comprision flange is bFLU
tFLU = 14.00 mm
hWeb = 500.00 mm
tWeb = 8.00 mm
bFLL = 280.00 mm
tFLL = 14.00 mm

3)- BEAM COLUMN DATA :-


Lin = 17.00 m Kin = 1.00
Lout = 5.00 m Kout = 1.00
Lu of compressin flg = 5.00 m
4)- CHECK SECTION :-
PROPERTIES OF SECTION :-

Y = 26.40 cm
A = 118.40 cm2
Ix = 60128.55 cm4
Iy = 5124.27 cm4
Sx.top = 2277.60 cm3
Sx.bot = 2277.60 cm3
Sy = 366.02 cm3
rx = 22.54 cm
ry = 6.58 cm
CHECK COMPACTNESS :-
dw/tw = 62.500 Web is Compact table(2.1a)
C/tf = 9.714 Flange is Compact table(2.1c)
The sec is Compact

CHECK NORMAL STRESSES :-


Cb = 1.75 table(2.2)
( 20.bf ) / (√ fy ) = 3.615 m ECP 16
Lumax = 3.615 m
( 1380.Af ) / ( fy.d ) x Cb = 7.89 m eqn. 2.18
Lateral torsional buckling of comp.flange There is LTB
lin = 75.437 < 180 SAFE
lout = 76.003 < 180 SAFE
lmax = 76.003
ALLOWABLE STRESS :-
Fbcx = 1.392 t/cm2
Fbcy = 1.728 t/cm2
Fca = 1.025 t/cm2
ACTUAL STRESS :-
fbcx = 0.790 t/cm2
fbcy = 0.000 t/cm2
fca = 0.169 t/cm2

A1 = 1.00 Cmx = 0.85


A2 = 1.15 Cmy = 1.00

( fca / Fc ) + ( fbcx / Fbcx ) A1 +( fbcy / Fbcy ) A2 = 0.73 t/cm2 < 1.00 SAFE

CHECK SHEAR STRESSES :-


qw = 0.00 t/cm2 < 0.840 SAFE eqn. 2.2