0% found this document useful (0 votes)
58 views

(Template) Hmine 223 Assignment 1

This document contains two questions regarding mine ventilation assignments. Question 1 involves calculating the equivalent resistance of an airway network system and determining the airflow quantity through one of the airways. Question 2 involves drawing fan performance and efficiency curves based on test data, and using that information to determine the fan operating point, power, and efficiency if installed in a duct of given specifications. Students are instructed to submit their assignments as PDFs on Google Classroom by July 18, 2021. Late submissions without a good reason will result in reduced marks.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views

(Template) Hmine 223 Assignment 1

This document contains two questions regarding mine ventilation assignments. Question 1 involves calculating the equivalent resistance of an airway network system and determining the airflow quantity through one of the airways. Question 2 involves drawing fan performance and efficiency curves based on test data, and using that information to determine the fan operating point, power, and efficiency if installed in a duct of given specifications. Students are instructed to submit their assignments as PDFs on Google Classroom by July 18, 2021. Late submissions without a good reason will result in reduced marks.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

HMINE 223: MINE VENTILATION ASSIGNMENT 1

QUESTION 1
a) Nine airways are shown in the sketch below and these form part of a ventilation network.
An airflow quantity of 50m3/s intakes through airway 8 and is exhausted through airway
9.

(In the above sketch, airways are numbered and shown circled while airway resistances are
shown to two significant decimals in Ns2m-8)
i. Calculate the equivalent resistance of the system based on network analysis
technique. (10)
ii. Determine the airflow quantity through airway 7. (5)
b)

The pressure drop over the parallel airways A and B shown in Figure above is 900 Pa. The air
density is 1.15 kg/m3. Determine the size of regulator required to reduce the quantity of air
flowing in airway B to 60m3/s. (10)

QUESTION 2

The following figures were obtained from a fan test conducted on a direct driven axial flow
fan (results shown in the Table below):
 Fan speed: 13.5 r/s
 Air density: 1.012 kg/m
Figures were obtained from a fan test conducted on a direct driven axial flow fan:
Quantity (m3/sec) Pressure (Pa) Fan Input power (kW)
0 930 3.6
2 840 4.6
4 870 5.9
6 910 7.8
8 860 10.0
10 730 12.4
12 490 14.7
13 310 15.0
14 0 14.6

From these figures draw:


 A complete fan performance curve, including power and efficiency curves.
 Determine the fan operating point, input power and efficiency of this fan if it is to be
installed in 760 mm galvanised duct, 54 m long, having a friction factor of 0.0035
Ns2/m4 at a prevailing density of 1.012 kg/m3.
Tip: A real graph paper is required (25)
Due date: 18 July 2021

Assignments to be submitted on Google Classroom ONLY in PDF format.

N.B: IF YOU HAND IN YOUR WORK LATE, WITHOUT A GOOD REASON FOR DOING
SO, YOUR MARK WILL BE REDUCED.