COMMERCIAL / INDUSTRIAL PRODUCTS
HOLLOW CORE FLOORS
BEARING DETAILS
BEARING ON SHELF ANGLES
Finishes Structural concrete infill
Nominal bearing 75 Projection of angle
Minimum bearing 50 beyond extremity of
flange 50 mm.
Greater where U.C.
sections are used.
Refer to Bison for
assistance.
25 mm
clearance
25 mm clearance is required to allow unit to be dropped
into position past the flange of the supporting U.B.
FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE: www.bison.co.uk
SECTION 01
HOLLOW CORE FLOORS
BEARING DETAILS
BEARING ON MASONRY
Finishes
Nominal bearing
t / 2 - 10 mm
Wall thickness
t
t 190
SIDE BEARING
Where required by Building Regulations for
sound insulation.
Finishes
Continuous wet mortar by
builder to take up camber
FOR FURTHER HELP AND INFORMATION PLEASE CALL: 01283 817500
COMMERCIAL / INDUSTRIAL PRODUCTS
HOLLOW CORE FLOORS
BEARING DETAILS
NARROW WALL BEARING
Finishes Structural concrete infill
Structural concrete infill
Nominal bearing Tie reinforcement at
t / 2 - 10 mm 400 c/c in joints and
(Min. 65 mm)
troughs provided in
Wall thickness 1200 wide units
t < 190 t
(Min. 140 mm)
(NB. In order to satisfy the tolerances in this situation, this
detail is only recommended where a full bearing is available
at the other end of the slab)
NARROW BEARING ON STEELWORK
Structural concrete infill
Finishes Structural concrete infill
Nominal bearing Tie reinforcement at
t / 2 - 10 mm 400 c/c in joints and
troughs provided in
1200 wide units
Wall thickness
t 150
t
(Min. 140 mm)
FOR MORE INFORMATION PLEASE VISIT OUR WEBSITE: www.bison.co.uk
SECTION 01
HOLLOW CORE FLOORS
BEARING DETAILS
END SLOTS IN UNITS
Slots may be provided in slab ends for the purpose of tying into
the structure for nominal continuity.
Finishes Structural concrete infill
TRIMMING OPENINGS
M.S.Trimmer. Fire protection, where necessary by
General Contractor.
Finishes
The recommendations for bearings of precast units are set out in Clause 5.2.3 of B.S. 8110:1997. These vary according to the type of floor
construction and the type of support material and building tolerances. In general nominal bearings of 100 mm on masonry or 75 mm on
steelwork are recommended but may be reduced dependent upon circumstances and subject to the above clause.
FOR FURTHER HELP AND INFORMATION PLEASE CALL: 01283 817500