Flange BS 5400-3:2000 Clause 9.3.7.2: M 0.32

This document summarizes the design checks performed on the main girder of a bridge. It includes calculations to check if the girder section is compact or non-compact in both tension and compression. The effective web thickness is also calculated. Support conditions are checked against lateral-torsional buckling requirements. Design moment resistance is determined and compared to the factored design moment demand at the ultimate limit state for the material grades specified.

Uploaded by

sandip
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views1 page

Flange BS 5400-3:2000 Clause 9.3.7.2: M 0.32

This document summarizes the design checks performed on the main girder of a bridge. It includes calculations to check if the girder section is compact or non-compact in both tension and compression. The effective web thickness is also calculated. Support conditions are checked against lateral-torsional buckling requirements. Design moment resistance is determined and compared to the factored design moment demand at the ultimate limit state for the material grades specified.

Uploaded by

sandip
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

SECTION : Main Girder Sheet No.

1
Units : N & mm
Bfc Bf comp 508.0 Holes in tension zone Compact Section Check
tfo tfo comp 38.0 Flange Web:
bfo dw 2286.0 hole f bR BS 5400-3:2000 Clause 9.3.7.2: m = 0.32
Compression angle
Lh x Lv x t
tw 9.0 24 63 (34tw/m)*(355/syw)0.5
= 1188 < dwe (2082) : Non-Compact

dw .
Bf tension 508.0 24 180 BD 56/10 Clause 9.3.8.2: d1/dw = 0.34
tw .
tfo tension 38.0 28tw(355/syw)0.5 = 314 < d1 (768) : Non-Compact

bfo 192.0 Web Flange:


Tension angle dh
Lh x Lv x t Lh comp 102.0 hole f dh Clause 9.3.7.3.1
t(h) 14.0 24 96 7tfo(355/syf)0.5 = 330 > bfo(192) : Compact

tfo Lv comp 102.0


bR t(v) 14.0 Hence Section :
Bft Lh tension 102.0 Non-Compact
Angle Dimensions: t(h) 14.0
Lh = length of horizontal leg Lv tension 102.0 Cl. 9.4 Effective Section
Lv = length of vertical leg
t = thickness of leg t(v) 14.0 (yc / tw)(syw / 355)0.5 = 105.6
sy 230 Web thickness twe = 6.9

Area
A gross = 69822
A net = 59827

X-X Axis Y-Y Axis Zpe


ytgross = 1.181E+3 Iyygross = 8.53696E+8 ytgross = 1.181E+3
ycgross = 1.181E+3 Iyynet = 7.83544E+8 ycgross = 1.181E+3
ytnet = 1.2798E+3 rygross = 1.10575E+2 ytnet = 1.55559E+3
ycnet = 1.0822E+3 rynet = 1.14441E+2 ycnet = 8.06406E+2
Ixxgross = 7.42704E+10 Zpe gross = 6.84562E+7
Ixxnet = 6.48479E+10 Zpe net = 5.88148E+7
Zxcnet = 5.99222E+7
Zxtnet = 5.06705E+7 Mpe = Zpe net sy = 13527 kNm

Cl. 9.7.2 Tick if using U-frame support


L 17068.0
lLT = le k4 h u / ry le 8668.0
h 0.94 Cl. 9.7.1 Support to compression flange for lw
k4 = [{4Z2pe(1-Iy/Ix)}/A2h2]1/4 = 0.849 c) Intermediate lateral restraints are not fully effective
i = Ic/(Ic+It) = 0.500 lw = 17068
lF = (lw/ry)(tf/D) = 2.483
yi = 0.8(2i-1) = 0.000
u = [{4i(1-i)+0.05lF2+yi2}0.5+yi]-0.5 = 0.935
lLT = 58.49
Cl. 9.8
Mult = Zxtnet sy = 11654 kNm
b = lLT[(syc/355)(Mult/Mpe)]0.5 = 43.7
Annex G.8 (Fig. 11b) BS5400 b > 30 h = 0.0035lw/le(b-30) = 0.0944
Annex G.8 (Fig. 11b) BD56 h = 0.0035(b-30) = 0.048
MR/Mult = 0.5[{1+(1+h)5700/b }-{(1+(1+h)5700/b2)2-22800/b2}0.5] = 0.882 (BS5400) ¦ 0.935 (BD56)
2

Cl. 9.9.1.2
At ULS MD = MR / gmgf3 = MR / (1.1*1.05) = 8898 kNm (BS5400)
9432 kNm (BD56)

Prepared by: Internet Version:


http://www.bridgedesign.org.uk
D.A.Childs B.Sc., C.Eng., M.I.C.E. Not to be used for commercial purposes unless verified by the user as being correct.