0% found this document useful (0 votes)
142 views1 page

Data Sheet For SINAMICS Control Unit CU230P-2 PN: Ambient Conditions Electrical Data

The document provides data and specifications for a SINAMICS Control Unit CU230P-2 PN. Key details include: - It operates on DC 24V power and has a max power consumption of 0.50A. - It supports communication protocols like PROFINET and EtherNet/IP. - Closed-loop control techniques like sensorless vector control and V/F control are supported. - It has standard digital and analog inputs/outputs and complies with industry standards like CE and UL. - Physical dimensions are 73mm x 199mm x 65.5mm and it has an IP20 protection rating.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views1 page

Data Sheet For SINAMICS Control Unit CU230P-2 PN: Ambient Conditions Electrical Data

The document provides data and specifications for a SINAMICS Control Unit CU230P-2 PN. Key details include: - It operates on DC 24V power and has a max power consumption of 0.50A. - It supports communication protocols like PROFINET and EtherNet/IP. - Closed-loop control techniques like sensorless vector control and V/F control are supported. - It has standard digital and analog inputs/outputs and complies with industry standards like CE and UL. - Physical dimensions are 73mm x 199mm x 65.5mm and it has an IP20 protection rating.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Data sheet for SINAMICS Control Unit CU230P-2 PN

MLFB-Ordering data
6SL3243-0BB30-1FA0

Figure similar

Client order no. : Item no. :


Order no. : Consignment no. :
Offer no. : Project :
Remarks :

Electrical data Ambient conditions

Operating voltage via Ambient temperature

The Power Module DC 24 V Operation -10 ... 60 °C (14 ... 140 °F)

External power supply DC 20 ... 29 V Storage -40 ... 70 °C (-40 ... 158 °F)

Max. power consumption 0.50 A Relative humidity

Power loss 5.50 W Max. operation 95 %

Inputs / outputs Communication


Standard digital inputs Communication PROFINET, EtherNet/IP

Number 6
Closed-loop control techniques
Switching level: 0→1 11 V
V/f linear / square-law / parameterizable Yes
Switching level: 1→0 5V

V/f with flux current control (FCC) Yes


Fail-safe digital inputs
V/f ECO linear / square-law Yes
Number 0
Sensorless vector control Yes
Digital outputs
Vector control, with sensor No

Number as relay changeover contact 2


Encoderless torque control Yes

Output (inductive load) DC 250 V, 2 A


Torque control, with encoder No
Output (resistive load) DC 30 V, 1 A

Number as relay NO contact 1 Standards


Compliance with standards CE, UL, cUL, RCM, SEMI F47
Output (resistive load) DC 30 V, 1 A

Analog / digital inputs CE marking Low-voltage directive 2014/35/EC

Number 2 (Differential input)


Mechanical data
Analog outputs Degree of protection IP20 / UL open type

Number 2 (Non-isolated output) Net weight 0.61 kg (1.34 lb)

Width 73.0 mm (2.87 in)


Connections
Signal cable Height 199.0 mm (7.83 in)

Depth 65.5 mm (2.59 in)


Conductor cross-section 0.15 ... 1.50 mm² (AWG 24 ... AWG 16)

Technical data are subject to change! There may be discrepancies between calculated and rating plate values.