Series HMI Connection Manual
Delta DVP TCP/IP
HMI Factory Setting:
Controller IP Address: 192.168.0.1
Controller COM Port: 502
Controller Station Number: 1
Control Area / Status Area: D0/D10
Connection
Standard Jumper Cable / Network Cable without jumper (Auto-detected by HMI)
Definition of PLC Read/Write Address
a. Registers
Format
Type Read/Write Range Data Length Note
Word No. (n)
X_Data Xn X0 – X360 Word Octal, 1
Y_Data Yn Y0 – Y360 Word Octal, 1
M0 – M1520, M1536 - Word 1
M_Data Mn
M4080
S_Data Sn S0 – S1008 Word 1
T_Register Tn T0 – T255 Word
C_Register Cn C0 – C199 Word
D_Register Dn D0 – D11999 Word
HC_Register Cn C200 – C255 Word
b. Contacts
Format
Type Read/Write Range Note
Bit No. (b)
X_Data Xb X0 – X377
Y_Data Yb Y0 – Y377
M_Data Mb M0 – M4080
S_Data Sb S0 – S1023
T_Coil Tb T0 – T255
V1.03 Revision January, 2016
Series HMI Connection Manual
Format
Type Read/Write Range Note
Bit No. (b)
C_Coil Cb C0 – C255
D_Register Dn.b D0.0 – D11999.15
NOTE
1) Device address must be a multiple of 16
2) The effective addresses of D_Register Dn are 2 blocks: D0~4095, D4096~11999,
“Multiple Duplicate” function is not provided for different block.