Process Flow Diagram FOR
Process Flow Diagram FOR
FOR
염수리튬 상업화 PJT
FOR REVIEW
OWNER
CLIENT :OWNER :
ARGENTINA
PEC PROJECT CODE :
DATE : 30 APRIL 2021
E&C
1 2 3 4 5 6 7 8 9 10
SIGNATURE
NO. DATE REVISION & DESCRIPTION
CHECKED REVIEWED
A '21.02.19 FOR PRELIMINARY S.J.S L.K.M
Legend & Symbol B '21.04.29 FOR REVIEW S.J.S L.K.M
A Equipment Identification Scale/Weighing Reactor & Tank Silo & Hopper Bag Filter Filter Press Packer Pump Valve Instrument
G : Agitator
TANK BUFFER
H : Hydraulic, Electric Heater
Dryer Conveyor Pump HOSE
I : Ion Exchanger Globe Valve Gauge Temperature
Heat Exchanger Micro Filter
J : Bag Massager
Elevator Bucket
M : Mixer Ribbon, Mill Jet, Mixer Inline
Flexible Connection
Shell & Tube Type Transmitter Temperature
N : DIESEL GENERATOR Pump Air Operated Diaphragm
210C01
210C02
LP DRYING PKG 210B01/02
NOTE 1 STORAGE
Item No. 110H11~34 110P03/04/05 120R01~04 120T01/02 120D01~06 120T03/04 130R01~04 130T01/02 130D01~05 130T03/04
Concentration Brine Feed Mg Removal Mg Slurry Mg Removal Mg Separated Ca Removal Ca Slurry 1st Ca Removal 1st CaSeparated
Equipment Storage Pond Separator Brine Storage Separator Brine Storage
Pond Reactor Buffer Tank Reactor Buffer Tank
Type - - Top Flat &Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Movable Filter Type Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Movable Filter Type Top Flat & Buttom Dish/Skirt
F
Material -' - FRP+3mm PP Lining FRP+3mm PP Lining - FRP+3mm PP Lining FRP+3mm PP Lining FRP+3mm PP Lining - FRP+3mm PP Lining
Capacity - - 100/135m3 100/135m3 9/11.6 T/h 100/135m3 100/135m3 100/135m3 1.27/1.5 T/h 100/135m3
Note
Item No. 210R01~04 210T01/02 210D01~05 210M01~05 210D06~10 210C01/02 210D01/02 210B01/02
LP Extraction LP Slurry LP Extraction LP 1st Washing LP 1st Washed LP Cake Belt LP Powder
Equipment LP Dryer PKG Storage Bin
Reactor Buffer Tank Separator Ribbon Mixer Removal Separator Conveyor
Type Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Fixed Filter Type - Fixed Filter Type -
Blade-STS304+PTFE Coat
Material FRP+3mm PP Lining FRP - /Body-FRP(Load Cell) - FRP+3mm PP Lining
Capacity 100/135m3 100/135m3 1.38/1.6 T/h 5.5/12m3 1.38/1.6 T/h 40m 4.2T/h 300m3
Note NO. DESCRIPTION MAT'(KS)
UNIT TOTAL PERUNIT TOTAL
REMARK'S
QUANTITY WEIGHT(kg)
G Item No. 130D06/07 130T05/06 210T03/04 220R01~04 220T01/02 220D01/02 220D03(s) 220P04/05 SCALE NONE PROJECTION
2nd Ca removal 2nd Ca Separated LP Separated P Removal P Removal P Removal P Separated ARGENTINA SIZE A1 DIMENSION mm
Equipment Separator Brine Storage Brine Storage P Buffer Tank Separator Separator Brine Storage Pond
Reactor 염수리튬 PLANT 염수리튬상업화 PJT POSCO
Type Fixed Filter Type Top Flat &Buttom Dish/Skirt Top Flat &Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Top Flat &Buttom Dish/Skirt Fixed Filter Type Movable Filter Type - TITLE MAIN PFD EQUIPMENT
EQUIPMENT
FACILITY
PROCESS FLOW DIAGRAM
REF. DWG. NO.
Material - FRP+3mm PP Lining FRP+3mm PP Lining FRP+3mm PP Lining FRP+3mm PP Lining - - FRP
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 0.1T/h 100/135m3 100/135m3 100/135m3 100/135m3 0.3T/h 0.3T/h 128/128m3 SIGNA
DWG. TURE J.J.H S.J.S L.K.M P.J.H DWG.
Note NO.
NO. KC-SEC1-000-ER102-00002
DATE 21.04.30 21.04.30 21.04.30 21.04.30
1 2 3 4 5 6 7 8 9 10
SIGNATURE
NO. DATE REVISION & DESCRIPTION
CHECKED REVIEWED
A '21.02.19 FOR PRELIMINARY S.J.S L.K.M
B '21.04.30 FOR REVIEW S.J.S L.K.M
Legend
A Slurry/Brine
Liquid
Gas/Vapor
Cake
Powder
NOTES
BOOSTING BOOSTING
POND POND
110P01~07 110P08~15
110B01~07 110B08~15
Brine Well Brine Well
C
110P(HOLD)
FCV
HOLD
MANIFOLD 110P03A FT (HOLD)
POND
110P(HOLD)
POSCO 1101
100H11 100H12 100H13 100H14 STORAGE
POND ARGENTINA PEC
Concentration Pond LT
D
NOTE 1
1102 120-00001
110P01A Brine
120R01/02
100H21 100H22 100H23 100H24 110P03 110P02A
Concentration Pond
1103 740-00001
Brine
110P03B
740M01
LT
E
110P01B
100H31 100H32 100H33 100H34 STORAGE
POND
Concentration Pond 110P02B
1102 120-00002
110P03C 110P04
110P01C Brine
120R03/04
110P02C
STORAGE LT 1103
POND 740-00001
F Brine
740M02
110P01D
110P05 110P02D
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 289.1/335m3/hr 24.2/32m3/hr, 20mH - SIGNA
DWG. TURE J.J.H S.J.S L.K.M P.J.H DWG.
Note NO.
NO. KC-SEC1-110-ER102-00001
DATE 21.04.30 21.04.30 21.04.30 21.04.30
1 2 3 4 5 6 7 8 9 10
SIGNATURE
NO. DATE REVISION & DESCRIPTION
CHECKED REVIEWED
A '21.02.19 FOR PRELIMINARY S.J.S L.K.M
B '21.04.30 FOR REVIEW S.J.S L.K.M
Legend
A Slurry/Brine
Squeeze Water 120D05(S) Liquid
Ground Water Gas/Vapor
Cake
Powder
Pre Coating
Return & Core
1203 013
Washing
B Instrument Air
Squeeze Water 120D01 860T02
Ground Water Core Washing 1206
1201 1202
G Item No. 120R01/02 120T01 120T03 120D01/02 120D05(S) 120G01/02 120G05 120P01A/B SCALE NONE PROJECTION
Mg Removal Mg Slurry Mg Separated Mg Removal Mg Removal Agitator for Mg Agitator for Mg Slurry Mg Slurry ARGENTINA SIZE A1 DIMENSION mm
Equipment Brine Storage Separator Reparator Transfer pump
Reactor Buffer Tank Removal Reactor Buffer Tank 염수리튬 PLANT 염수리튬 상업화 PJT POSCO
Type Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Movable Filter Type Movable Filter Type 3Stages 3Stages Centrifugal
TITLE MG REMOVAL PROCESS (1/2) EQUIPMENT
EQUIPMENT
FACILITY
PROCESS FLOW DIAGRAM
REF. DWG. NO.
Material FRP+3mm PP Lining FRP+3mm PP Lining FRP+3mm PP Lining - - FRP Lining FRP Lining FRP
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 100/135m3 100/135m3 100/135m3 9/11.6 T/h - 95kW 11kW 298.6/345m3/hr, 20mH SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.
Pre Coating
Return & Core
1203 013
Washing
Instrument Air
Squeeze Water 120D04 860T02
Core Washing 1206
Pre Coating
1203 1203
Return & Core
Washing
011 Squeeze Water 120D06(S)
850P11
011
Cloth Washing Water
850P22
130-00002 Pre Coating
Brine 120T04
Return & Core 135㎥
130P04C/D Washing
740-00001 7401
740P01C/D
110-00001 1102
Brine
120G03 120G04 120G06 120P10A/B
110P01C/D GRW GRW 1205 130-00002
1204 1204 1204
GRW GRW Brine
130R03/04
120P03C/D 1304 130-00002
120R03 120R04 120T02 CAKE
130D03/04/05
1304 130-00002
135㎥ 135㎥ 1201 135㎥
CAKE
Mg Cake 130D07
120P01D 1201 120P02C 1202 1202 120C01
1201 120C02
120P02D 120C03
120P01C Instrument Air
NOTE 1
Item No. 120P15/16(HOLD) 120P03C/D 120P10A/B 120C01/02/03 120P02C/D/(E) 120P15/16 (HOLD)
(Mg / Ca Cake)
Mg Slurry Mg Separated Pump Mg Removal F/P Mg&Ca Cake Mg Slurry
Equipment Brine Feeding Pump Washing Recycle Belt conveyor Feeding Pump
Drain Pump
Mg Removal Mg Slurry Mg Separated Mg Removal Mg Removal Agitator for Mg Agitator for Mg Slurry Mg Slurry ARGENTINA
Equipment Brine Storage Separator Reparator
Reactor Buffer Tank Removal Reactor Buffer Tank Transfer pump
Type Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Movable Filter Type Movable Filter Type 3Stages 3Stages Centrifugal
Material FRP+3mm PP Lining FRP+3mm PP Lining FRP+3mm PP Lining - - FRP Lining FRP Lining FRP
Capacity 100/135m3 100/135m3 100/135m3 9/11.6 T/h - 95kW 11kW 298.6/345m3/hr, 20mH
Note Reuse DP F/P VVVF(Inverter)
1 2 3 4 5 6 7 8 9 10
SIGNATURE
NO. DATE REVISION & DESCRIPTION
CHECKED REVIEWED
A '21.02.19 FOR PRELIMINARY S.J.S L.K.M
B '21.04.30 FOR REVIEW S.J.S L.K.M
011 Squeeze/Cloth Washing
Ground Water
1309 Legend
850P33
A Slurry/Brine
Liquid
Gas/Vapor
1301 1302
130P11/12 Fail Open 120-00001
Brine
130P01B 130P02A 130P03A 120R01/02
G Item No. 130R01/02 130T01 130T03 130T05 130D01/02 130D06 130P01A/B 130P02A/B SCALE NONE PROJECTION
Ca Removal Ca Slurry 1st CaSeparated 2nd Ca Separated 1st Ca Removal 2nd Ca removal Ca Slurry 1st Ca Slurry ARGENTINA SIZE A1 DIMENSION mm
Equipment Brine Storage Brine Storage Separator Separator Transfer pump Feeding pump
Reactor Buffer Tank 염수리튬 PLANT 염수리튬상업화 PJT POSCO
Type Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Fixed Filter Type Fixed Filter Type Centrifugal Centryfugal
TITLE CA REMOVAL PROCESS (1/2) EQUIPMENT
EQUIPMENT
FACILITY
PROCESS FLOW DIAGRAM
REF. DWG. NO.
Material FRP+3mm PP Lining FRP+3mm PP Lining FRP+3mm PP Lining FRP+3mm PP Lining - - FRP FRP
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 100/135m3 100/135m3 100/135m3 100/135m3 1.27/1.5 T/h 0.1T/h 298.6/345m3/hr,20mH 72/105m3/hr, 50mH SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.
850P33
Legend
A 011 130D03 Slurry/Brine
Squeeze/Cloth Washing
Ground Water Liquid
Gas/Vapor
850P03
Cake
Core Drain Powder
1303
1304
1309
Core Washing
B 130D04
Core Drain
1303
1303 1309
Core Washing
750-00001 7501
Na2CO3 130D05(S) 130D07 013
C
750C01 Instrument Air
860T02
140-00001 (HOLD) 1401
Core Drain
Brine 1303
140P09AB 011
Pre Coating
Cloth Washed Water
120-00002 1205 850T02
Core Drain 1306
Brine
011
120P03C/D
Squeeze Water
130G03 130G04 1304 850T01
D
GRW GRW 130G06 BY-PASS
LT LT
GRW GRW
LT LT LT
AT AT 1305 1309
G Item No. 130R03/04 130T02 130T04 130T06 130D03/04/05(S) 130D07 130P01C/D 130P02C/D/(E) SCALE NONE PROJECTION
Ca Removal Ca Slurry 1st CaSeparated 2nd Ca Separated 1st Ca Removal 2nd Ca removal Ca Slurry 1st Ca Slurry ARGENTINA SIZE A1 DIMENSION mm
Equipment Brine Storage Brine Storage Separator Separator Transfer pump Feeding pump
Reactor Buffer Tank 염수리튬 PLANT 염수리튬상업화 PJT POSCO
Type Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Fixed Filter Type Fixed Filter Type Centrifugal Centryfugal
TITLE CA REMOVAL PROCESS (2/2) EQUIPMENT
EQUIPMENT
FACILITY
PROCESS FLOW DIAGRAM
REF. DWG. NO.
Material FRP+3mm PP Lining FRP+3mm PP Lining FRP+3mm PP Lining FRP+3mm PP Lining - - FRP FRP
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 100/135m3 100/135m3 100/135m3 100/135m3 1.8T/h 0.1T/h 298.6/345m3/hr,20mH 72/105m3/hr, 50mH SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.
Legend
A Slurry/Brine
Liquid
Gas/Vapor
Cake
Powder
NOTES
POSCO POSCO
PEC ARGENTINA PG ARGENTINA PEC (HOLD)
220-00001/00002 2205 1401 130-00001/00002
Brine Brine
220P03A/B 130R01/02/03/04
140P09A/B
NOTE 1
2nd Evaporation
Equipment
Pond
Type -
Material
Capacity
Note NO. DESCRIPTION MAT'(KS)
UNIT TOTAL PERUNIT TOTAL
REMARK'S
QUANTITY WEIGHT(kg)
G Item No. 140P09A/B 140P01 140P02 140P03 140P04 140P05 140P06 140P07 SCALE NONE PROJECTION
Evaporated Brine 2nd Evaporation 2nd Evaporation 2nd Evaporation 2nd Evaporation 2nd Evaporation 2nd Evaporation 2nd Evaporation ARGENTINA SIZE A1 DIMENSION mm
Equipment Feeding Pump Pond Pond Pond Pond Pond Pond Pond 염수리튬 PLANT 염수리튬 상업화 PJT POSCO
Type VertIcal Centryfugal - - - - - - -
TITLE BRINE EXAPORATION PROCESS EQUIPMENT
EQUIPMENT
FACILITY
PROCESS FLOW DIAGRAM
REF. DWG. NO.
Material FRP - - - - - - -
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 46.8/55m3/hr, 30mH - - - - - - - SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.
Note NO.
NO. KC-SEC1-140-ER102-00001
DATE - 21.04.30 21.04.30 21.04.30 21.04.30
1 2 3 4 5 6 7 8 9 10
SIGNATURE
NO. DATE REVISION & DESCRIPTION
CHECKED REVIEWED
A '21.02.19 FOR PRELIMINARY S.J.S L.K.M
B '21.04.30 FOR REVIEW S.J.S L.K.M
Legend
A Slurry/Brine
Liquid
Gas/Vapor
Cake
Powder
730-00001 7301
H3PO4
CIRCULATION
730T03
780-00001 7801
210D02
C NaOH
780C01 2103 2103 210-00003
Brine
016 7301
2102 210T03
H3PO4
820P01/11
Pre Coating
130-00001 1308
Brine
130P04A/B
Squeeze Water
D 860-00001
Fume 2104 2104
860S01/02
LP Washing Water
210D06
210R01 210R02 210T01 210-00003
2101 DI Water
Core Drain
Core Drain
E
135㎥ 135㎥ 210D06
135㎥
210-00003
Cake
Cake
Pre Coating
210D06
2101 2102
F WT WT
G Item No. 210R01/02 210T01 210D01/02 210M01/02 210G01/02 210G05 210P01A/B 210P02A/B SCALE NONE PROJECTION
LP Extraction LP Slurry LP Extraction LP 1st Washing Agitator for LP Agitator for LP LP Slurry LP Slurry ARGENTINA SIZE A1 DIMENSION mm
Equipment Separator Transfer pump Feeding Pump
Reactor Buffer Tank Ribbon Mixer Extraction Reactor Buffer tank 염수리튬 PLANT 염수리튬 상업화 PJT POSCO
Type Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Fixed Filter Type - 3Stages 3Stages Centrifugal Centrifugal
TITLE LP EXTRACTION PROCESS(1-5) EQUIPMENT
EQUIPMENT
FACILITY
PROCESS FLOW DIAGRAM
REF. DWG. NO.
Blade-STS304+PTFE Coat
Material FRP+3mm PP Lining FRP - FRP Lining FRP Lining FRP FRP
SUPPLIER (PEC)
/Body-FRP(Load Cell) DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 100/135m3 100/135m3 1.38/1.6 T/h 5.5/12m3 95kW 11kW 298.6/345m3/h, 20mH 74/105m3/hr, 50mH SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.
210D03
Squeeze/Cloth Washing Legend
DI Water
A 2103 Slurry/Brine
Liquid
Gas/Vapor
Cake
Powder
210D04
2102 2103 2103
B 210-00004
Brine
210T04
016 7301
H3PO4
820P01/11 Squeeze Water
130-00002 1308 Pre Coating
Brine
130P04C/D
D 860-00001
Fume
860S01/02
2104
210G03 210G04 210G06
GRW GRW 210-00004
Core Drain
LP Washing Water
LP Washing Water
GRW GRW
LT LT LT 210D08/09/10
AT AT
210-00004
DI Water
Core Drain
Core Drain
Core Drain
210R03 210R04 210T02
2101 210D08/09/10
210-00004
Cake
Cake
Cake
E
135㎥ 135㎥ 135㎥ Pre Coating
210D08/09/10
2101 2102
INSTRUMENT INSTRUMENT INSTRUMENT
AIR AIR AIR
210P01D 210P02C
2101 2102
WT WT WT
G Item No. 210R03/04 210T02 210D03/04/05(S) 210M03/04/05(S) 210G03/04 210G06 210P01C/D 210P02C/D SCALE NONE PROJECTION
LP Extraction LP Slurry LP Extraction LP 1st Washing Agitator for LP Agitator for LP LP Slurry LP Slurry ARGENTINA SIZE A1 DIMENSION mm
Equipment Separator Transfer pump Feeding Pump
Reactor Buffer Tank Ribbon Mixer Extraction Reactor Buffer tank 염수리튬 PLANT 염수리튬 상업화 PJT POSCO
Type Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt Fixed Filter Type - 3Stages 3Stages Centrifugal Centrifugal
TITLE LP EXTRACTION PROCESS(2/5) EQUIPMENT
EQUIPMENT
FACILITY
PROCESS FLOW DIAGRAM
REF. DWG. NO.
Blade-STS304+PTFE Coat
Material FRP+3mm PP Lining FRP - FRP Lining FRP Lining FRP FRP
SUPPLIER (PEC)
/Body-FRP(Load Cell) DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 100/135m3 100/135m3 1.38/1.6 T/h 5.5/12m3 95kW 11kW 298.6/345m3/h, 20mH 74/105m3/hr, 50mH SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.
Legend
A Slurry/Brine
Liquid
Gas/Vapor
Cake
Powder
210-00001 2103
B Brine
210D06
210-00001 2105
Brine
C 210P03A
Squeeze Water
Core Drin
DI Water
Cloth Wash Water
D
210D07 013
2105 Instrument Air
210-00001
Brine 860T02
2106
210P03B Filtrate Brine
210-00001 LT
Core Drain
E 210M01/02
210T03
135㎥
210-00001
Dl Water
210M01/02
2107 210-00004
LP Cake
210C01
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 100/135m3 1.38/1.6 T/h 284.5/330m3/hr, 20mH SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.
Note NO.
NO. KC-SEC1-210-ER102-00003
DATE - 21.04.30 21.04.30 21.04.30 21.04.30
1 2 3 4 5 6 7 8 9 10
SIGNATURE
NO. DATE REVISION & DESCRIPTION
CHECKED REVIEWED
A '21.02.19 FOR PRELIMINARY S.J.S L.K.M
B '21.04.30 FOR REVIEW S.J.S L.K.M
210-00001 2103
Brine Legend
A Slurry/Brine
Liquid
011 Squeeze/Cloth Washing Gas/Vapor
DI Water Cake
Powder
850P04
210D08
210-00002 2105
Brine
210P03C
B
Core Drin
DI Water
Core Washing/Cake Washing
DI Water
C 210D09 013
2105 Instrument Air
210-00002 Filtrate Brine
Brine 860T02
210P03D
2106
Squeeze Water
LT
210D10(S)
210-00002 2105
210T04
Brine
210P03E 135㎥
E 210-00002
Core Drain
210M03/04/05 2111 2111 220-00002
Brine
210-00002 220R03/04
Dl Water 210P04C
210M03/04/05
210-00002
Pre Coating
210P04D
210M03/04/05
2107 2107 2107 2107
F 210-00003
LP Cake
21D06/07 LP Cake
210C01
210C02
210-00005
LP Cake
210D01/02
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 100/135m3 1.38/1.6 T/h 284.5/330m3/hr, 20mH 40m SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.
Note NO.
NO. KC-SEC1-210-ER102-00004
DATE - 21.04.30 21.04.30 21.04.30 21.04.30
1 2 3 4 5 6 7 8 9 10
SIGNATURE
NO. DATE REVISION & DESCRIPTION
CHECKED REVIEWED
A '21.02.19 FOR PRELIMINARY S.J.S L.K.M
B '21.04.30 FOR REVIEW S.J.S L.K.M
Legend
A Slurry/Brine
Liquid
Gas/Vapor
Cake
Powder
210-00004
C
LP Cake
210CO2
LP DRYING
PKG
D
210B01/02
TO DOWNSTREAM
LP Powder
300㎥
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 4.2T/h 300m3 SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.
Note
Includes Cyclone, Dryer, Heat Exchanger, NO.
NO. KC-SEC1-210-ER102-00005
Dehumidifier, Scrubber DATE - 21.04.30 21.04.30 21.04.30 21.04.30
1 2 3 4 5 6 7 8 9 10
SIGNATURE
NO. DATE REVISION & DESCRIPTION
CHECKED REVIEWED
A '21.02.19 FOR PRELIMINARY S.J.S L.K.M
B '21.04.30 FOR REVIEW S.J.S L.K.M
Legend
A Slurry/Brine
Liquid
Gas/Vapor
Cake
Powder
B
8510 220D01 013
Squeeze/Core/Cloth Washing
Ground Water Instrument Air
860T02
WASTE WATER
Squeeze Water
Pre Coating
C
Core Drain
8520
Cloth Washed Water
740-00001 7402
Ca(OH)2 2202 2204 2203
740P03AB
2111 220-00002
210-00003 HAP Cake
Brine Core Drain 220C01
D 210P04AB
Pre Coating
E
85㎥ 220P03A
135㎥ 135㎥
135㎥
220R01 220R02 220T01
2201 2202
220P04
G Item No. 220R01/02 220T01 220P04 220D01 220G01/02 220G05 220P01A/B 220P02A/B SCALE NONE PROJECTION
P Removal P Buffer P Separated Brine P Removal Agitator for P Agitator for P P Slurry transfer P Slurry ARGENTINA SIZE A1 DIMENSION mm
Equipment Storage Pond Separator Pump Feeding Pump
Reactor Tank Removal Reactor Buffer tank 염수리튬 PLANT 염수리튬 상업화 PJT POSCO
Type Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt - Fixed Filter Type 3Stages 3Stages Centrifugal Centrifugal
TITLE P REMOVAL PROCESS (1/2) EQUIPMENT
EQUIPMENT
FACILITY
PROCESS FLOW DIAGRAM
REF. DWG. NO.
Material FRP+3mm PP Lining FRP+3mm PP Lining FRP - FRP Lining FRP Lining FRP FRP
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 100/135m3 100/135m3 128/128m3 0.3T/h 95kW 11kW 298.6/345m3/hr, 20mH 147m3/hr, 50mH SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.
Legend
A Slurry/Brine
Liquid
Gas/Vapor
Cake
Powder
8510 220D02
Squeeze/Core/Cloth Washing
Ground Water
Core Drain
B
WASTE WATER Cloth Wash Water
Pre Coating
220G03 220G04
D 2201 220C01
GRW GRW 2205 140-00001
GRW GRW 220G06 Brine
LT LT
AT TI AT TI 140P01/05
LT 2203
220W01
LT
220-00001 2204
F
HAP Cake
220D01
HAP Cake belt HAP Cake P separated water Brine Feeding LP Removal
Equipment conveyor pump Separator
Packing Scale transfer pump
P Removal P Buffer P Separated Brine LP Removal Agitator for P Agitator for P P Slurry transfer LP Slurry ARGENTINA SIZE A1 DIMENSION mm
Equipment Storage Pond Separator Pump Feeding Pump
Reactor Tank Removal Reactor Buffer tank 염수리튬 PLANT 염수리튬 상업화 PJT POSCO
Type Top Flat & Buttom Dish/Skirt Top Flat & Buttom Dish/Skirt - Fixed Filter Type 3Stages 3Stages Centrifugal Centrifugal
TITLE P REMOVAL PROCESS (2/2) EQUIPMENT
EQUIPMENT
FACILITY
PROCESS FLOW DIAGRAM
REF. DWG. NO.
SUPPLIER (PEC)
DRAWN CHECKED REVIEWED APPROVED DRAWN CHECKED REVIEWED APPROVED
MAKER POSCO
POSCO
Capacity 75m3 92m3 92m3 0.3T/h 55kW 11kW 298.6/345m3/hr, 20mH 147m3/hr, 50mH SIGNA
DWG. TURE - J.J.H S.J.S L.K.M P.J.H DWG.