Air Conditioners

Air
RA20 Series

Rheem Prestige™ Series


Variable Speed Air Conditioners

RA20 Series
Efficiencies up to 20 SEER/13 EER
Nominal Sizes 2, 3, 4 & 5 Ton
[7.03, 10.6, 14.06 & 17.6 kW]
Cooling Capacities 17.3 to 60.5 kBTU
[5.7 to 17.7 kW]
Seasonal Energy Efficiency Ratio - SEER
THIS MODEL
17.00

10.0 USES LESS ENERGY 17.0

“Proper sizing and installation of equipment is critical to achieve optimal


performance. Split system air conditioners and heat pumps must be
matched with appropriate coil components to meet Energy Star.
Ask your Contractor for details or visit www.energystar.gov.”

• PlusOne™ Energy Efficiency offers minimum of 20 SEER • Curved louver panels – provide ultimate coil protection,
and 13 EER system performance across all capacities. enhance cabinet strength, and increased cabinet rigidity
• PlusOne™ Expanded Valve Space – 3"-4"-5" service valve • Optimized fan orifice – optimizes airflow and reduces unit
space – provides a minimum working area of 27-square sound
inches for easier access • Rust resistant screws – confirmed through 1500-hour salt
• PlusOne™ Triple Service Access – 15" wide, industry lead- spray testing
ing corner service access – makes repairs easier and faster. • Diagnostic service window with two-fastener opening –
The three fastener removable corner allows optimal access to provides access to the high and low pressure.
internal unit components. Individual louver panels come out
once fastener is removed, for faster coil cleaning and easier • External gauge port access – allows easy connection of
cabinet reassembly “low-loss” gauge ports
• EcoNet™ Enabled product. The EcoNet Smart Home System • Single-row condenser coil (up thru 4 tons) – makes unit lighter
provides advanced air & water control for maximum energy and allows thorough coil cleaning to maintain “out of the box”
savings and ideal comfort. performance
• New composite base pan – dampens sound, captures louver • 35% fewer cabinet fasteners and fastener-free base – allow
panels, eliminates corrosion and reduces number of fasteners for faster access to internal components and hassle-free
needed panel removal
• Powder coat paint system – for a long lasting professional finish • Service trays – hold fasteners or caps during service calls
• The Copeland Scroll™ Variable Speed Compressor has a • QR code – provides technical information on demand for
modulating technology which provides more precise temper- faster service calls
ature control, lower humidity and greater efficiency. The over- • Fan motor harness with extra long wires allows unit top to be
drive feature provides cooling load up to 107°F. removed without disconnecting fan wire.
• Modern cabinet aesthetics – increased curb appeal with visu- • High and low pressure standard on all models.
ally appealing design

FORM NO. A11-224 REV. 1


Table of Contents
Air
RA20 Series

TABLE OF CONTENTS
Standard Feature ......................................................................................................3
Available SKUs ........................................................................................................3
Features & Benefits ..............................................................................................4-8
Model Number Identification ..............................................................................9-10
General Data/Electrical Data ..................................................................................11
Accessories ..........................................................................................................12
Weighted Sound Power ..........................................................................................12
Smart Home Systems ......................................................................................13-14
Unit Dimensions......................................................................................................15
Clearances ..............................................................................................................16
Wiring Diagrams ....................................................................................................17
Refrigerant Line Size Information ......................................................................18-19
Performance Data ............................................................................................20-22
Guide Specifications ..............................................................................................23
Limited Warranty ....................................................................................................24

2
Standard Feature/Available SKUs
Air
RA20 Series

Standard Feature Table


STANDARD FEATURES
Feature 24 36 48 60
R-410A Refrigerant √ √ √ √
Maximum SEER 20.5 20.5 20.5 20.5
Maximum EER 13 13 13 13
EcoNet Enabled √ √ √ √
Copeland Scroll™ Variable Speed Compressor √ √ √ √
Compressor Sound Blanket √ √ √ √
Variable speed outdoor fan motor √ √ √ √
Swept wing fan blade √ √ √ √
Field Installed Filter Drier √ √ √ √
Front Seating Service Valves √ √ √ √
Internal Pressure Relief Valve √ √ √ √
Internal Thermal Overload √ √ √ √
Low Ambient capability √ √ √ √
3-4-5 Expanded Valve Space √ √ √ √
Composite Basepan √ √ √ √
1" Screw Control Box Access √ √ √ √
15" Access to Internal Components √ √ √ √
Quick release louver panel design √ √ √ √
No fasteners to remove along bottom √ √ √ √
Optimized Venturi Airflow √ √ √ √
Single row condenser coil √ √ √ 2 Row
Powder coated paint √ √ √ √
Rust resistant screws √ √ √ √
QR code √ √ √ √
External gauge ports √ √ √ √
Service trays √ √ √ √
√ = Standard

Available SKUs
Available Models Description
RA2024AJVCB 2 ton EcoNet™ Enabled inverter driven Rheem Prestige ™ Series Variable Speed Air Conditioner-208/230/1/60
RA2036AJVCB 3 ton EcoNet™ Enabled inverter driven Rheem Prestige ™ Series Variable Speed Air Conditioner-208/230/1/60
RA2048AJVCB 4 ton EcoNet™ Enabled inverter driven Rheem Prestige ™ Series Variable Speed Air Conditioner-208/230/1/60
RA2060AJVCB 5 ton EcoNet™ Enabled inverter driven Rheem Prestige ™ Series Variable Speed Air Conditioner-208/230/1/60

3
Features & Benefits
Air
RA20 Series

Introduction to RA20 Air Conditioner


The RA20 is our EcoNet™ Enabled, Inverter Driven Prestige™ Along with the EcoNet Smart Home System the RA20 is
Series Variable Speed Air Conditioner and is part of the Rheem matched with the RHMV Constant CFM Variable Speed EcoNet
Air Conditioner product line that extends from 13 to 20 SEER. Enabled Air Handler ( 3 ) or can be applied in a Furnace applica-
This highly featured and reliable air conditioner is designed for tion with the EcoNet Enabled Two-Stage Variable Speed R802V
years of reliable, efficient operation when matched with Rheem or R96V Gas Furnaces or the fully modulating R97V and RCF
indoor aluminum evaporator coils and furnaces or air handler Aluminum Cased Furnace Coils with EEV ( 4 ). See individual
units with aluminum evaporators. specification documents for more details of the indoor products.

The EcoNet Smart Home System is an integrated system for a


home’s Heating, Cooling and Water Heating equipment – allow- 3
ing homeowners to manage the products that consume up to
65% of the their home’s energy. EcoNet sets Rheem, and our
distributor and contractor customers, apart in the industry with a
unique, advanced and efficient technology solution.
The RA20 Prestige™ Series inverter driven Variable Speed Air
Conditioner is exclusively designed to operate with the EcoNet™
Smart Home System. Developed by Rheem, The EcoNet Smart
Home System allows homeowners to manage select high-
efficiency, EcoNet Enabled air conditioners, heat pumps, gas
furnaces, air handlers and water heaters from anywhere. EcoNet
Enabled products in a home are connected through standard
HVAC wiring; then contractors have the option of adding an
EcoNet WiFi Kit ( 1 ) so the homeowner can access everything
remotely through a free mobile app or mobile-friendly website.
The Control Center ( 2 ) acts as both a thermostat for the heat-
ing and cooling system, and a remote control for connected
water heaters.

4
Features & Benefits
Air
RA20 Series

13
9

14

17

11 12 7

16 19
18

20
6
10 15

How It Works
The RA20 Prestige™ Series Inverter Driven Variable Speed Air which is equipped with the latest swept wing fan technology
Conditioner’s ( 5 ) variable speed outdoor unit control (VSODU) ( 14 ) and the Electronic Expansion Valve (EEV) ( 15 ) which syncs
( 6 ) continuously monitors the EcoNet control temperature and up with the compressor speed to deliver the exact capacity the
humidity set point, suction pressure ( 7 ), suction temperature home needs to meet its comfort requirements. The result of this
( 8 ), outdoor coil temperature ( 9 ) and outdoor temperature advanced technology is significantly improved energy efficiency
( 10 ) and feeds this information to the Copeland Inverter Control and comfort. Energy efficiency is improved by precise load
Motor Drive ( 11 ). The Copeland Inverter Control Motor Drive matching, less cycling on and off and low amp gradual com-
converts AC to DC power, sends it to the Copeland Scroll™ pressor, outdoor and indoor motor operation. Comfort is
variable speed compressor ( 12 ) Brushless Permanent Magnet improved by precise temperature control, precise humidity con-
motor (BPM), dynamically adjusting its speed. Simultaneously trol and extra capacity during extreme summer and cold weather
the VSODU provides input to the ECM outdoor fan motor ( 13 ) conditions.

5
Features & Benefits
Air
RA20 Series

5 1 2

14
17

12 7
11

8
19
16
18 20
6
10 15

System Component Descriptions


EcoNet Control Center – ( 2 ): The EcoNet Control Center Swept Wing Fan Blade – ( 14 ) is the latest technology in
serves as the hub of communication for a home’s Heating, outdoor fans that increase efficiency and reduces air noise.
Cooling and Water Heating systems and is required to operate
an EcoNet Enabled Heating and Cooling system in a fully com- The Electronic Expansion Valve (EEV) – (Located on the
municating mode. The EcoNet Control center displays detail indoor coil) is an electronically driven refrigerant control valve.
diagnostic from outdoor and indoor connected units. See indi- A small stepper motor is used to open and close the valve to
vidual specification documents for more details of the EcoNet precisely control refrigerant flow. It is controlled by the EcoNet
Control Center. Air Handler Control or stand alone EEV Control in furnace coil
applications. Either control receives input from the pressure
EcoNet Cooling and Heating WiFi Module – ( 1 ) is required to transducer and suction sensor to control the refrigerant in the
remotely operate an EcoNet Enabled Heating and Cooling cooling mode. The EEV is superior to a TXV (thermostatic
system from the EcoNet web portal and mobile apps. See indi- expansion valve) because the EEV controls superheat at the
vidual specification documents for more details of the EcoNet evaporator coil under varying load and refrigerant flow condi-
Control Center. tions, more precisely than traditional TXV’s.
Variable Speed Outdoor Unit Control (VSODU) – ( 6 ) is where The Filter – ( 16 ) is an electrical device that “cleans” the AC
control wiring is hooked to the RA20. The VSODU control takes power component. This low pass filter only permits the passage
input from the EcoNet Control Center, outdoor suction tempera- of 60-Hertz signal to the inverter drive.
ture and pressure sensors, outdoor air temperature and commu-
nicates to the Copeland Inverter Control Motor Drive, EEV, The Pressure Transducer – ( 7 ) is used to measure suction
outdoor fan and indoor blower to precisely control system pressure in the outdoor air conditioner. The VSODU takes this
capacity output of the air conditioner cooling mode. It also is input to operate low pressure and make decisions on system
equipped with Dual Seven-Segment Display for technician inter- operation such as low ambient cooling.
face, operation status and fault code communication. Two Various temperature sensors – There is an outdoor air sensor
momentary buttons allow technician to initiate various operating ( 10 ), an outdoor coil sensor ( 9 ), a discharge line temperature
modes. Various LED’s communicate active EcoNet communica- sensor (not shown, located on discharge line), a suction line
tion, microprocessor activity and EEV operation. See I&O for temperature sensor ( 8 ) and a compressor sump temperature
more details. sensor (not shown, located bottom of compressor). The VSODU
The Copeland Inverter Control Motor Drive – ( 11 ) converts uses these temperature measurements to operate the system.
incoming single-phase AC power to 3 phase DC simulated sine The Choke – ( 17 ) is provided to absorb power spikes that might
wave power. Once power is converted the Copeland Inverter occur on the DC line.
Control Motor Drive varies frequency of the power to the com-
pressor varying the compressor speed. The Copeland Inverter Ferrite Rings – ( 18 ) are iron cores through which AC power is
Control Motor Drive has active protection algorithms that keep looped keeping any electrical noise contained. They also reduce
the compressor safely inside its operating envelope. the induction of electrical transient into the DC drive.

The Copeland Scroll™ Variable Speed compressor – ( 12 ) The Suction Accumulator – ( 19 ) prevents liquid refrigerant from
utilizes a Brushless Permanent Magnet Motor (BPM) that varies entering the compressor.
the Scroll speed, thus, varying the refrigerant flow. The robust
scroll design has proven reliability over competing compressor
technologies.

6
Features & Benefits
Air
RA20 Series

Features
In addition all RA20 Prestige™ Series inverter driven Variable 20
Speed Air Conditioners have the following features: 18

4 16
6 17
6 8 5 7
( 17 ). Outdoor coil heights range from as short as 35" to 48".
Our unique composite base ( 3 ) reduces sound emission, elimi-
Disassembly to this degree and complete reassembly only takes
nates rattles, significantly reduces fasteners, eliminates corrosion
a first time service technician less than 10 minutes. ( 17 )
and has integrated brass compressor attachment inserts ( 4 ).
Furthermore it has incorporated into the design, water manage- All units utilize formed louver panels
ment features, means for hand placement ( 5 ) for unit maneu- which provide industry leading coil
vering, screw trays ( 6 ) and inserts for lifting off unit pad. ( 7 ) protection. Louver removal for coil 19
cleaning is accomplished by removing
Service Valves ( 8 ) are rigidly mounted in the composite base one screw and lifting the panel out of
with 3" between suction and discharge valves, 4" clearance the composite base pan. ( 19 ) All RA20
below service valves and a minimum of 5" above the service 2, 3, 4 ton units utilize single row coils
valves, creating industry leading ease of installation. The minimum ( 18 ) making cleaning easy and com-
plete, restoring the performance of the
air conditioner back to out of the box
13 performance levels year after year.
10
9
12 11 The outdoor fan motor has sleeve bearings and is inherently
protected. The motor is totally enclosed for maximum protection
from weather, dust and corrosion. ( 20 ) Access to the outdoor fan
is made by removing four fasteners from the fan grille. The out-
door fan can be removed from the fan grille by removing 4
27 square-inches around the service valves allows ample room fasteners in the rare case outdoor fan motor fails.
to remove service valve schrader prior to brazing, plenty of Each cabinet has optimized composite ( 21 ) fan orifice assuring
clearance for easy brazing of the suction and discharge lines to efficient and quiet airflow.
service valve outlets, easy access and hookup of low loss refrig-
erant gauges ( 9 ), and access to the service valve caps for
21
opening.
Controls are accessed from the corner of the unit by removing
only one fastener from the control access cover, revealing the
industry’s largest 15" wide and 22" tall control area ( 10 ). With all
this room in the control area the high voltage electrical whip ( 11 ) The entire cabinet has post powder paint ( 22 ) achieving 1000
can easily be inserted through the right size opening in the hour salt spray rating, allowing the cabinet to retain its aesthetics
bottom of the control area. Routing it leads directly to lugs for throughout its life.
connection. The low voltage control wires ( 12 ) are easily con-
nected to the units VSODU terminal strip. The service window
( 14 ) can be removed by removing two screws to view the interior 26

of unit. ( 15 ) (High and low pressure is standard on RA20 models). 22


If in the rare event, greater access is needed to internal compo-
25

24
23
14

The Copeland Scroll™ Variable Speed compressors with


standard internal pressure relief and internal thermal overload
15
are used on all capacities assuring longevity of high efficient
nents, such as the compressor, the entire corner of the unit can and quiet operation for the life of the product. All RA20 Air
be removed along with the top cover assembly to have unprece- Conditioner come standard with high and low pressure switches
dented access to interior of the unit ( 16 ). Extra wire length is reinforced vinyl compressor sound covers containing a 11/2 inch
incorporated into each outdoor fan and compressor so top thick batt of fiberglass insulation and open edges are sealed
cover and control panel can be positioned next to the unit. Or with a 1 inch wide hook and loop fastening tape for superior
with minimal effort the plug can be removed from the compres- sound quality.
sor and the outdoor fan wires can be removed from the VSODU
to allow even more uncluttered access to the interior of the unit

7
Features & Benefits
Air
RA20 Series

Features (con’t.)
Each unit is shipped with filter drier for field installation and will Optional Accessories
trap any moisture or dirt that could contaminate the refrigerant (Refer to accessory chart for model #)
system.
3"/6"/12"
• Gray high density polyethylene feet are available to raise unit
27 off of mounting surface away from moisture

Accessories
EcoNet Control Center
The EcoNet Control Center serves
as the hub of communication for a
All cabinets have industry leading structural strength due to the home’s Heating, Cooling and
composite base pan ( 23 ), interlocking corner post ( 24 ), formed Water Heating systems, and is
curved louver panels ( 25 ) and drawn top cover ( 26 ) making it required to operate an EcoNet
the most durable cabinet on the market today. Enabled Heating & Cooling
Each RA20 capacity has undergone rigorous psychometric test- system in a fully communicating
ing to assure performance ratings of capacity, SEER and mode.
EER per AHRI Standard 210/240 rating conditions. Also
each unit bears the UL mark and each unit is certified to RETST601SYS
UL 1995 safety standards.
Each unit has undergone specific strain and modal testing to WiFi Kit for Heating and Cooling Systems
assure tubing ( 27 ) is outside the units natural frequency and that
the suction and discharge lines connected to the compressor The WiFi kit is required to remotely
withstand any starting, steady state operation, or shut down operate EcoNet Enabled Heating
forces imposed by the compressor. and Cooling Systems from the
EcoNet Web portal and mobile
All units have been sound tested in sound chamber to AHRI 270 apps.
rating conditions, and A-weighted Sound Power Level tables
produced, assuring units have acceptable noise qualities (see
page 12). Each unit has been ran in cooling operation at 95°F and
sound ratings for the RA20 range from as low as 68 dBA at low
speed and as high as 76 dBA at 95°F rated conditions.
REWRA630SYS
All units have been ship tested to assure units meet stringent
“over the road” shipping conditions.
Thermostor Kit - RXHT-A02
As manufactured, all units in the RA20 family have cooling capa-
bility to 40°F. Addition of low ambient control will allow the unit
to operate down to 0°F. Factory testing is performed on each
unit. All component parts meet well defined specification and
continually go through receiving inspections. Each component
installed on a unit is scanned, assuring correct component uti-
lization for a given unit capacity and voltage. All condenser coils
are leak tested with pressurization test to 550#’s and once
installed and assembled, each units’ complete refrigerant
system is helium leak tested. All units are fully charged from the
factory for up to 15 feet of piping. All units are factory run tested.
The RA20 has a 10-year conditional unit replacement warranty
(registration required) and a 10 year limited parts warranty.

8
Air Conditioners*
R A 20 24 A J V C B *

Brand Product SEER Capacity† Major Series* Voltage Type Controls Minor Series** Option
Category BTU/HR Code
Rheem A - Air Conditioners 13 - 13 SEER 18 - 18,000 [5.28 kW] A - 1st Design J - 1ph, 208-230/60 1 - Single-stage C - Communicating B - High N/A
14 - 14 SEER 24 - 24,000 [7.03 kW] B - 2nd Design C - 3ph, 208-230/60 2 - Two-stage N - Non-Communicating and low
16 - 16 SEER 30 - 30,000 [8.79 kW] V - Inverter pressure
17 - 17 SEER 36 - 36,000 [10.55 kW] control
20 - 20 SEER 42 - 42,000 [12.31 kW]
48 - 48,000 [14.07 kW]
60 - 60,000 [17.58 kW]
*See page 3 for available SKU’s.
†Two-stage and inverter available in whole capacities only.

Heat Pumps (For Reference)**


R P 20 24 A J V C A *

Brand Product SEER Capacity† Major Series* Voltage Type Controls Minor Series** Option
Category BTU/HR Code
Rheem P - Heat Pump 13 - 13 SEER 18 - 18,000 [5.28 kW] A - 1st Design J - 1ph, 208-230/60 1 - Single-stage C - Communicating A - 1st Design N/A
14 - 14 SEER 24 - 24,000 [7.03 kW] C - 3ph, 208-230/60 2 - Two-stage N - Non-Communicating
15 - 15 SEER 30 - 30,000 [8.79 kW] D - 3ph, 460/60 V - Inverter
17 - 17 SEER 36 - 36,000 [10.55 kW] P - Piston
20 - 20 SEER 42 - 42,000 [12.31 kW]
48 - 48,000 [14.07 kW]
60 - 60,000 [17.58 kW]
†Two-stage and inverter available in whole capacities only.

Furnace Coils (For Reference)**


R C F 24 17 S E A M C A *

Brand Product Type Capacity Width Efficiency Metering Major Orientation Casing Minor Series** Option
Category BTU/HR Device Series* Code
Rheem C - Evap Coil F - Furn Coil 24 - 24,000 [7.03 kW] 14 - 14" S- Standard Eff. T-TXV A - 1st Design M - Multipoise C - Cased A - 1st Design N/A
H - Air-Handler 36 - 36,000 [10.55 kW] 17 - 17.5" M- Mid Eff. E-EEV V - Vertical only/ U - Uncased
Air

Coil 48 - 48,000 [14.07 kW] 21 - 21" H- High Eff. P-Piston convertible


60 - 60,000 [17.58 kW] 24 - 24.5" H - Ded.
Horizontal only

NOTE: The above Model Number ID’s are for reference only. Available SKU’s are listed on the standard features/available SKU page of model spec sheet.
RA20 Series

[ ] Designates Metric Conversions

9
Model Number Identification
90%+ AFUE Gas Furnaces (For Reference)**
R 96 V A 70 2 3 17 M S A

10
Air

Brand Series Motor Major Rev Input Stages Air Flow Cabinet Configuration Nox Minor Rev
BTU/HR Width
Rheem 90 - 90 AFUE V - Variable speed A - 1st Design 040 - 42,000 [12.31 kW] 1 - Single-stage 3 - up to 3 ton 14 - 14" M - Multi X - Low Nox A - 1st Design
92 - 92 AFUE T - Constant 060 - 56,000 [16.41 kW] 2 - Two-stage 5 - 3 1/2 up to 5 ton 17 - 17.5" S - Standard
RA20 Series

95 - 95 AFUE Torque 070 - 70,000 [20.51 kW] M - Modulating 21 - 21"


96 - 96 AFUE (X-13) 085 - 84,000 [24.62 kW] 24 - 24.5"
97 - 97 AFUE P - PSC 100 - 98,000 [28.72 kW]
115 - 112,000 [32.82 kW]
Model Number Identification

80% AFUE Gas Furnaces (For Reference)**


R 80 2 V A 075 3 17 M S A

Brand Series Stages Motor Major Rev Input Air Flow Cabinet Configuration Nox Minor Rev
BTU/HR Width
Rheem 80 - 80+ AFUE 1 - Single-stage V - Variable speed A - 1st Design 050 - 50,000 [15 kW] 3 - up to 3 ton 14 - 14" M - Multi X - Low Nox A - 1st Design
2 - Two-stage T - Constant Torque (X-13) 075 - 75,000 [22 kW] 4 - 2 1/2 to 4 ton 17 - 17.5" D - Down S - Standard
P - PSC premium 100 - 100,000 [29 kW] 5 - 3 1/2 up to 5 ton 21 - 21" Z - Down &
S - PSC standard 125 - 125,000 [37 kW] 24 - 24.5" zero clearance
150 - 150,000 [44 kW] down flow

Air Handlers (For Reference)**


R H M V 36 17 S E A C J A 000 *

Brand Product Stages of Motor Type Capacity Width Coil Size Metering Major Controls Voltage Minor Factory Heat Option
Category Airflow BTU/HR Device Series* Series** Cap Code
Rheem H - Air 1 - Single-Stage V - Variable 24 - 24,000 [7.03 kW] 14 - 14" S - Standard T - TEV A - 1st Design C -Communicating J - 1ph, 208-240/60 A - 1st Design 00 - no *TBD
Handler 2 - Two-Stage Speed 36 - 36,000 [10.55 kW] 17 - 17.5" Eff. E - EEV N -Non-comm factory heat
M - Modulating T - Constant 48 - 48,000 [14.07 kW] 21 - 21" M -Mid Eff. P - Piston with option
Torque 60 - 60,000 [17.58 kW] 24 - 24.5" H - High Eff. code
P - PSC

NOTE: The above Model Number ID’s are for reference only. Available SKU’s are listed on the standard features/available SKU page of model spec sheet.

[ ] Designates Metric Conversions


General Data/Electrical Data
Air
RA20 Series

Physical Data
Model No. RA2024A RA2036A RA2048A RA2060A
Nominal Tonnage 2.0 3.0 4.0 5.0
Valve Connections
Liquid Line O.D. – in. 3/8 3/8 3/8 3/8
Suction Line O.D. – in. 3/4 3/4 7/8 7/8
Refrigerant (R-410A) furnished oz.¹ 148 193.6 196 376
Compressor Type Scroll
Outdoor Coil
Net face area – Outer Coil 22.2 22.3 32.5 32.5
Net face area – Inner Coil — — — —
Tube diameter – in. 3/8 3/8 3/8 3/8
Number of rows 1 1 1 2
Fins per inch 20 20 22 20
Outdoor Fan
Diameter – in. 24 24 26 26
Number of blades 3 3 3 3
Motor hp 1/5 1/3 1/2 1/2
CFM 3330 4315 6240 6175
RPM 772 825 935 900
watts 83 114 278 278
Shipping weight – lbs. 226 244 263 316
Operating weight – lbs. 214 236 255 308

Electrical Data
Line Voltage Data (Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Maximum overcurrent protection (amps)² 35 45 70 80
Minimum overcurrent protection (amps)² 25 35 60 60
Minimum circuit ampacity³ 21 29 46 48
Compressor
Rated load amps 15 20.1 32 34.1
Locked rotor amps 35 35 50 50
Condenser Fan Motor
Full load amps 1.4 3.5 5.3 5.3
Locked rotor amps N/A N/A N/A N/A
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional
refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.

11
Accessories/Weighted Sound Power
Air
RA20 Series

Accessories
Model No. RA2024 RA2036 RA2048 RA2060
EcoNet Control Center RETST601SYS RETST601SYS RETST601SYS RETST601SYS
WiFi Kit for Heating & Cooling REWRA630SYS REWRA630SYS REWRA630SYS REWRA630SYS
Compressor sound cover STD STD STD STD
Heat pump Riser 6 in. 686020 686020 686020 686020

Weighted Sound Power Level (dBA)


VS Standard TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
Stage
ODU Rating (dBA) 125 250 500 1000 2000 4000 8000
High 68 47.1 47.7 58.8 57.1 55.0 52.7 45.6
(-)A2024
Low 58.9 29 36.5 42 45.7 42.3 43.2 33
High 72 42.9 52.8 62.7 63.6 58.7 54.1 52.4
(-)A2036
Low 57 29.2 36.7 44.9 45.4 42.2 39.4 32.2
High 72 48.2 55.3 64.6 61.7 56.2 51.7 46.2
(-)A2048
Low 54 30.6 39 42.2 42.5 36.5 35.2 35
High 76 50.7 62.7 67.7 65.4 64.2 59.2 54.9
(-)A2060
Low 70 46.6 50.5 62.7 52.9 49.4 46 41.4
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)

12
Smart Home Systems
Air
RA20 Series

Integrated Controls

EcoNet is smart, new technology developed exclusively by Rheem that allows Heating, Cooling,
and Water Heating products to communicate with each other on one integrated network.

Easy to Setup, Easy to Use, Easy to Save


• Built with our 360°+1 design philosophy, it • 7-Day programmable schedule with
is optimized for Installability™, Performance, Smooth Arrival & Whole Home Vacation
Integration & Serviceability options
• Controls 65%† or more of a typical home’s • Detailed operating status, alarm history,
energy use from a single device and audible alerts
• Can reduce energy costs by up to 30%†† • Supports humidifier accessories or over-
cool based dehumidification
Features
• One-touch access to Water Heater
• Added support for new EEV (Electronic Management†††
Expansion Valve) Air Handlers, Air Condi-
tioners and Heat Pumps* • Easily manage from anywhere in the world
with the compatible WiFi Module & EcoNet
• Rapid installation with standard 4-wire app for smart phones and tablets
configuration
• Automatically configures communicating Warranty
equipment with optimal settings • 5-Year limited warranty from date of
installation EcoNet™ Control Center
• Adapts to home décor through Home control with intuitive LCD
††† Source – Department of Energy
interchangeable faceplates and adjustable touchscreen navigation
background coloring ††† When compared to non-programmable thermostats.
Source: ENERGY STAR® for Programmable
• Full-color, 4.7" LCD touchscreen display Thermostats
RETST601SYS
with easy-to-read icons and text ††† Requires wired connection to EcoNet Enabled Electric
• Convenient date, time and indoor/outdoor or Hybrid Water Heaters
temperature indications
• 5 operating modes with short-cycle protec-
tion (Heat, Cool, Auto, Emergency Heat,
Fan Only)

EcoNet Control Center Compatibility


OFFERINGS HEATING & COOLING WATER HEATING

Product WiFi Kit for Electric Gas


Gas Furnaces Air Handlers Air Conditioners Heat Pumps Hybrid
Categories HVAC Tank Powered
Tank
REWRA630SYS Models HB50 Damper
Ending in Tank
RH2T Models
Models R97V R96V R802V RHMV* RA20* RASL-JEC RA17 RARL-JEC RP20* RP17* RPRL-JEC EC2 Models
(EEV**)
RETST601SYS √ √ √ √ √ √ √★ √ √★ √ √ √★ √ √ √
*Available in 2016
**Electronic Expansion Valve (EEV) Models

★ Comfort Control2 System™ Translator for EcoNet Required


Installation of the RETRN620CC2 Comfort Control2 System™ Translator on the outdoor unit’s control board is required to operate Comfort Control2 System™ Air Conditioner
and Heat Pump models (****-JEC) with an EcoNet Control Center in a fully communicating mode when matched with EcoNet Enabled Furnaces or Air Handlers*.

13
Smart Home Systems
Air
RA20 Series

The EcoNet™ WiFi Kit for Heating & Cooling Systems


(REWRA630SYS) provides remote control of EcoNet
Enabled air and water products from smart phones,
tablets, and personal computers using the home’s
internet connection.

Features
• Enables remote operation from: • 24" Port-to-Port Connection Cable
- The EcoNet App on Apple® mobile devices • 1" x 2" Double Adhesive Mounting Tape
(iPhone®, iPad®, & iPod® Touch) using iOS • RJ12 Y Splitter (for use with
version 7.0 or later communicating electric water heaters)
- The EcoNet App on Android™ based smart
phones and tablets using Android™ version Compatibility
4.4 or later
• Works with any HVAC System
- Recent versions of popular web browsers which includes an EcoNet Enabled
such as Internet Explorer, Chrome, Safari, furnace or air handler and an EcoNet
etc. control center.
• Designed for use with EcoNet communi-
cating HVAC Systems Warranty
• Compatible with 802.11 b/g/n WiFi networks • 1 Year from installation date
• WPA-2 Security using AES/CCMP
• Status LEDs:
- Power & Equipment
Connection Status
- Home Network WiFi Status
- Internet Connection Status
• “WLAN SETUP" factory reset button

WiFi Kit Components


• EcoNet WiFi Module EcoNet WiFi Kit for Heating
• Installation Instructions
& Cooling Systems
• V Power Adapter REWRA630SYS
• Junction Box

HVAC Connection Illustration

14
Unit Dimensions
Air
RA20 Series

Unit Dimensions
OPERATING SHIPPING
MODEL
H (Height) L (Length) W (Width) H (Height) L (Length) W (Width)
NO.
INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm
RA2024 39 990 33.75 857 33.75 857 41.56 1055 37.64 956 37.56 954
RA2036 39 990 33.75 857 33.75 857 41.56 1055 37.64 956 37.56 954
RA2048 51 1295 35.75 908 35.75 908 53.56 1360 39.37 999 39.64 1006
RA2060 51 1295 35.75 908 35.75 908 53.56 1360 39.37 999 39.64 1006

[ ] Designates Metric Conversions ST-A1226-02-00

15
CLEARANCES

16
Air

WALL WALL
6⬙
Clearances

24⬙
RA20 Series

(152.4)
(609.6)
Service

24⬙ 12⬙ 12⬙


(609.6)
WALL

(304.8) (304.8)
Service
6⬙
(152.4)
6⬙
(152.4)
12⬙
(304.8)

WALL

24⬙ 24⬙ 24⬙


(609.6) (609.6) (609.6)
Service Service Service

18⬙ 24⬙ 24⬙


(457.2) (609.6) (609.6)
24⬙ recommended 24⬙ recommended
6⬙ minimum 6⬙ minimum

NOTE: NUMBERS IN () = mm
IMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re-circulation of discharge air.

ST-A1225-01-00
Wiring Diagram/Application Guidelines
Air
RA20 Series

Control Wiring

FIGURE 2
TYPICAL ECONET COMMUNICATING SYSTEM™ WIRING DIAGRAM

Communicating Thermostat
E1 E2 R C
Indoor Unit Outdoor Unit

E1 E1
E2 E2
R R
C C

WIRING INFORMATION
Line Voltage
–Field Installed - - - - - -
–Factory Standard

Application Guidelines
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
6. Do not apply capillary tube indoor coils to these units.
7. Factory – supplied filter drier must be installed.

17
Refrigerant Line Size Information
Liquid Line Selection Chart

18
Air

Liquid Line Size Elevation (Above or Below) Indoor Coil


R-410A System Liquid Line Size Total Equivalent Length - Feet [m]
Connection Size
Capacity Model (Inch O.D.) [mm]
(Inch I.D.) [mm] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [45.72] 150 [45.72] 175 [53.34] 200 [60.96] 225 [68.58] 250 [76.20] 275 [83.82] 300 [91.44]
Maximum Vertical Separation – Feet [m]
1/4 [6.35] 25 [7.62] 50 [15.24] 35 [10.67] 15 [4.57] N/R N/R N/R N/R N/R N/R N/R N/R
RA20 Series

5/16 [7.94] 25 [7.62] 50 [15.24] 75 [22.86] 80 [24.38] 75 [22.86] 70 [21.34] 60 [18.29] 55 [16.76] 50 [15.24] 45 [13.72] 40 [12.19] 35 [10.67]
24 3/8" [9.53] 3/8 [9.53] 25 [7.62] 50 [15.24] 75 [22.86] 95 [28.96] 90 [27.43] 90 [27.43] 90 [27.43] 85 [25.91] 85 [25.91] 80 [24.38] 80 [24.38] 80 [24.38]
7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 95 [28.96] 95 [28.96] 95 [28.96] 95 [28.96] 95 [28.96] 95 [28.96] 90 [27.43] 90 [27.43]
1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.48] 95 [28.96] 95 [28.96]
1/4 [6.35] 25 [7.62] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/16 [7.94] 25 [7.62] 50 [15.24] 60 [18.29] 45 [13.72] 30 [9.14] 20 [6.1] 5 [1.52] N/R N/R N/R N/R N/R
Refrigerant Line Size Information

36 3/8" [9.53] 3/8 [9.53] 25 [7.62] 50 [15.24] 75 [22.86] 80 [24.38] 75 [22.86] 70 [21.34] 65 [19.81] 60 [18.29] 55 [16.76] 50 [15.24] 50 [15.24] 45 [13.72]
7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 90 [27.43] 90 [27.43] 85 [25.91] 85 [25.91] 80 [24.38] 80 [24.38] 80 [24.38] 75 [22.86] 75 [22.86]
1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 95 [28.96] 95 [28.96] 90 [27.43] 90 [27.43] 90 [27.43] 90 [27.43] 90 [27.43] 85 [25.91] 85 [25.91]
1/4 [6.35] 20 [6.1] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/16 [7.94] 25 [7.62] 50 [15.24] 35 [10.67] 20 [6.1] N/R N/R N/R N/R N/R N/R N/R N/R
48 3/8" [9.53] 3/8 [9.53] 25 [7.62] 50 [15.24] 70 [21.34] 65 [19.81] 60 [18.29] 55 [16.76] 50 [15.24] 40 [12.19] 35 [10.67] 30 [9.14] 25 [7.62] 20 [6.1]
7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 80 [24.38] 75 [22.86] 75 [22.86] 70 [21.34] 70 [21.34] 65 [19.81] 65 [19.81] 60 [18.29] 60 [18.29]
1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 85 [25.91] 85 [25.91] 80 [24.38] 80 [24.38] 80 [24.38] 80 [24.38] 75 [22.86] 75 [22.86] 75 [22.86]
1/4 [6.35] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/16 [7.94] 25 [7.62] 10 [3.05] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
60 3/8" [9.53] 3/8 [9.53] 25 [7.62] 50 [15.24] 40 [12.19] 30 [9.14] 20 [6.1] 10 [3.05] N/R N/R N/R N/R N/R N/R
7/16 [11.12] 25 [7.62] 50 [15.24] 60 [18.29] 55 [16.76] 50 [15.24] 45 [13.72] 40 [12.19] 35 [10.67] 35 [10.67] 30 [9.14] 25 [7.62] 20 [6.1]
1/2 [12.71] 25 [7.62] 50 [15.24] 65 [19.81] 65 [19.81] 60 [18.29] 60 [18.29] 55 [16.76] 55 [16.76] 55 [16.76] 50 [15.24] 50 [15.24] 45 [13.72]
NOTES: [ ] Designates Metric Conversions
N/R = Application not recommended.
Grey =This application is acceptable, but the long line guidelines must be followed. Reference Long Line Set section in the I&O
Refrigerant Line Size Information (con’t.)
Vapor Line Selection Chart
Vapor Line Capacity Multiplier Table
R-410A System Vapor Line Size Total Equivalent Length - Feet [m]
Connection Size
Capacity Model (Inch O.D.) [mm]
(Inch I.D.) [mm] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [45.72] 150 [45.72] 175 [53.34] 200 [60.96] 225 [68.58] 250 [76.20] 275 [83.82] 300 [91.44]

5/8 [15.88] 0.99 0.99 0.98 0.97 0.96 0.96 0.94 0.93 0.92 0.91 0.9 0.9
3/4 [19.05] 1.00 1.00 1.00 0.99 0.99 0.99 0.99 0.98 0.98 0.98 0.97 0.97
24 3/4" [19.06] 7/8 [22.23] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
1-1/8 [28.58] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/8 [15.88] 0.98 0.96 0.94 0.92 0.9 0.89 0.87 0.85 0.84 0.83 0.84 0.82
3/4 [19.05] 1.00 0.99 0.98 0.98 0.97 0.96 0.95 0.94 0.94 0.93 0.93 0.92
36 3/4" [19.06] 7/8 [22.23] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
1-1/8 [28.58] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/8 [15.88] 0.99 0.98 0.98 0.96 0.95 0.94 0.93 0.92 0.91 0.9 0.89 0.88
3/4 [19.05] 0.98 0.94 0.91 0.89 0.87 0.84 0.83 0.81 0.8 0.82 0.81 0.83
48 7/8" [22.22] 7/8 [22.23] 1.00 0.99 0.99 0.98 0.98 0.97 0.98 0.97 0.97 0.96 0.95 0.95
1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
1-1/8 [28.58] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
5/8 [15.88] 0.99 0.98 0.96 0.95 0.94 0.92 N/R N/R N/R N/R N/R N/R
3/4 [19.05] 0.97 0.93 0.89 0.87 0.84 0.83 N/R N/R N/R N/R N/R N/R
60 7/8" [22.22] 7/8 [22.23] 1.00 0.99 0.99 0.98 0.98 0.97 N/R N/R N/R N/R N/R N/R
1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
1-1/8 [28.58] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R
NOTES: [ ] Designates Metric Conversions
N/R = Application not recommended.
All calculations assume a 3/8" liquid line
Air
RA20 Series

19
Refrigerant Line Size Information
Performance Data
Air
RA20 Series

Performance Data @ AHRI Standard Conditions – Cooling


High Sales Volume Tested Combination (HSVTC)
Indoor Coil or Total Capacity Net Sensible Net Latent Indoor
Outdoor Unit SEER EER AHRI#
Air Handler BTU/H [kW] BTU/H [kW] BTU/H [kW] CFM [L/s]
RA2024AJV RHMV2421MEAC 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.50 14.50 825 [389.4] 8852367
RA2036AJV RHMV6021SEAC 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 8852374
RA2048AJV RHMV6021SEAC 46000 [13.5] 34400 [10.1] 11600 [3.4] 20.50 13.00 1550 [731.5] 8852381
RA2060AJV RHMV6024MEAC 57000 [16.7] 40800 [12.0] 16200 [4.7] 20.50 13.00 1650 [778.7] 8930680

R802V: Prestige 2-Stage 80% ECM Furnace Ratings


Total Capacity Net Sensible Net Latent Indoor
Outdoor Unit Furnace Indoor Coil SEER EER AHRI#
BTU/H [kW] BTU/H [kW] BTU/H [kW] CFM [L/s]
RCF2417SEA 24000 [7.0] 17000 [5.0] 7000 [2.1] 20.50 14.50 825 [389.4] 8955207
RA2024AJV R802VA050317M RCF2421MEA 23800 [7.0] 17600 [5.2] 6200 [1.8] 20.00 14.50 825 [389.4] 9034730
RCF3621MEA 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.50 14.50 825 [389.4] 8955210
RCF2417SEA 24000 [7.0] 17000 [5.0] 7000 [2.1] 20.50 14.50 825 [389.4] 9008286
RA2024AJV R802VA075317M RCF2421MEA 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.50 14.50 825 [389.4] 9008287
RCF3621MEA 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.50 14.50 825 [389.4] 9008289
RCF2421MEA 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.50 14.50 825 [389.4] 9008288
RA2024AJV R802VA075421M
RCF3621MEA 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.50 14.50 825 [389.4] 9008290
RCF2417SEA 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.50 14.50 825 [389.4] 8955208
RA2024AJV R802VA100521M RCF2421MEA 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.50 14.50 825 [389.4] 8955209
RCF3621MEA 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.50 14.50 825 [389.4] 8955211
RCF3621MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 19.50 12.20 1175 [554.5] 9008291
RA2036AJV R802VA050317M
RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 12.50 1175 [554.5] 8955212
RCF3621MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.00 12.50 1225 [578.1] 9008292
RA2036AJV R802VA075317M
RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 12.50 1225 [578.1] 9008297
RCF3621MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 19.50 12.50 1225 [578.1] 9008293
RA2036AJV R802VA075421M RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 9008298
RCF6024MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 9008300
RCF3621MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 19.50 13.00 1225 [578.1] 9008294
RA2036AJV R802VA100521M RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 8955213
RCF6024MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 8955214
RCF3621MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 19.50 13.00 1225 [578.1] 9008295
RA2036AJV R802VA125524M RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 9008299
RCF6024MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 9008301
RCF6021SEA 45000 [13.2] 33300 [9.8] 11700 [3.4] 20.50 12.00 1550 [731.5] 9008302
RA2048AJV R802VA075421M
RCF6024MEA 46500 [13.6] 33800 [9.9] 12700 [3.7] 20.50 12.50 1550 [731.5] 9008304
RCF6021SEA 45500 [13.3] 33900 [9.9] 11600 [3.4] 20.50 12.50 1575 [743.3] 8955215
RA2048AJV R802VA100521M
RCF6024MEA 47000 [13.8] 34500 [10.1] 12500 [3.7] 20.50 13.00 1575 [743.3] 8955216
RCF6021SEA 45500 [13.3] 33800 [9.9] 11700 [3.4] 20.50 13.00 1550 [731.5] 9008303
RA2048AJV R802VA125524M
RCF6024MEA 47000 [13.8] 34300 [10.1] 12700 [3.7] 20.50 13.00 1550 [731.5] 9008305
RCF6021SEA 55500 [16.3] 38100 [11.2] 17400 [5.1] 17.50 11.70 1675 [790.5] 9008306
RA2060AJV R802VA075421M
RCF6024MEA 56000 [16.4] 39800 [11.7] 16200 [4.7] 19.50 12.00 1675 [790.5] 9008308
RCF6021SEA 56000 [16.4] 38600 [11.3] 17400 [5.1] 18.00 12.00 1675 [790.5] 8955217
RA2060AJV R802VA100521M
RCF6024MEA 56500 [16.6] 40300 [11.8] 16200 [4.7] 20.00 12.50 1675 [790.5] 8955218
RCF6021SEA 56000 [16.4] 38600 [11.3] 17400 [5.1] 18.00 12.50 1675 [790.5] 9008307
RA2060AJV R802VA125524M
RCF6024MEA 57000 [16.7] 40800 [12.0] 16200 [4.7] 20.00 12.50 1675 [790.5] 9008309

[ ] Designates Metric Conversions

20
Performance Data
Air
RA20 Series

Performance Data @ AHRI Standard Conditions – Cooling


R96V: 96% AFUE 2-stage Variable Speed Multipoise Gas Furnace Ratings
Total Capacity Net Sensible Net Latent Indoor
Outdoor Unit Furnace Indoor Coil SEER EER AHRI#
BTU/H [kW] BTU/H [kW] BTU/H [kW] CFM [L/s]
RA2024AJV R96VA0402317M RCF2417SEA 24000 [7.0] 17000 [5.0] 7000 [2.1] 20.50 14.00 825 [389.4] 8930663
RCF2417SEA 24000 [7.0] 17000 [5.0] 7000 [2.1] 20.50 14.00 825 [389.4] 8930664
RA2024AJV R96VA0602317M
RCF2421MEA 23800 [7.0] 17600 [5.2] 6200 [1.8] 20.50 14.00 825 [389.4] 8852362
RCF2417SEA 24000 [7.0] 17000 [5.0] 7000 [2.1] 20.50 14.50 825 [389.4] 8930665
RA2024AJV R96VA0702317M
RCF2421MEA 23800 [7.0] 17600 [5.2] 6200 [1.8] 20.00 14.50 825 [389.4] 8852363
RCF2417SEA 24000 [7.0] 17000 [5.0] 7000 [2.1] 20.50 14.00 825 [389.4] 8930666
RA2024AJV R96VA0852521M RCF2421MEA 23800 [7.0] 17600 [5.2] 6200 [1.8] 20.00 14.00 825 [389.4] 8930671
RCF3621MEA 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.00 14.00 825 [389.4] 8930673
RA2036AJV R96VA0602317M RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 12.50 1200 [566.3] 8852368
RA2036AJV R96VA0702317M RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.00 12.20 1200 [566.3] 8930677
RCF3621MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 19.50 12.50 1225 [578.1] 9008296
RA2036AJV R96VA0852521M
RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 8852369
RA2036AJV R96VA1002521M RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 8930506
RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 12.50 1225 [578.1] 8852370
RA2036AJV R96VA1152524M
RCF6024MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 12.50 1225 [578.1] 8930508
RA2048AJV R96VA0602317M RCF6021SEA 44000 [12.9] 30200 [8.9] 13800 [4.0] 20.50 12.50 1200 [566.3] 8930681
RA2048AJV R96VA0702317M RCF6021SEA 43500 [12.7] 29700 [8.7] 13800 [4.0] 20.50 12.20 1200 [566.3] 8930682
RA2048AJV R96VA0852521M RCF6021SEA 45000 [13.2] 33300 [9.8] 11700 [3.4] 20.50 12.00 1550 [731.5] 8852375
RA2048AJV R96VA1002521M RCF6021SEA 45000 [13.2] 33300 [9.8] 11700 [3.4] 20.50 12.00 1550 [731.5] 8852376
RCF6021SEA 45000 [13.2] 33400 [9.8] 11600 [3.4] 20.50 12.00 1575 [743.3] 8852377
RA2048AJV R96VA1152524M
RCF6024MEA 46500 [13.6] 34000 [10.0] 12500 [3.7] 20.50 12.50 1575 [743.3] 8930685
RA2060AJV R96VA0852521M RCF6021SEA 55000 [16.1] 36700 [10.8] 18300 [5.4] 17.50 12.00 1550 [731.5] 8930510
RA2060AJV R96VA1002521M RCF6021SEA 55500 [16.3] 38100 [11.2] 17400 [5.1] 17.50 11.70 1675 [790.5] 8930511
RCF6021SEA 55500 [16.3] 38100 [11.2] 17400 [5.1] 17.50 11.70 1675 [790.5] 8930512
RA2060AJV R96VA1152524M
RCF6024MEA 56000 [16.4] 39800 [11.7] 16200 [4.7] 19.50 12.00 1675 [790.5] 8852382

[ ] Designates Metric Conversions

21
Performance Data
Air
RA20 Series

Performance Data @ AHRI Standard Conditions – Cooling


Ratings
Total Capacity Net Sensible Net Latent Indoor
Outdoor Unit Furnace Indoor Coil SEER EER AHRI#
BTU/H [kW] BTU/H [kW] BTU/H [kW] CFM [L/s]
RCF2417SEA 24000 [7.0] 17000 [5.0] 7000 [2.1] 20.50 14.00 825 [389.4] 8930667
RA2024AJV R97VA060M317U
RCF2421MEA 23800 [7.0] 17600 [5.2] 6200 [1.8] 20.50 14.00 825 [389.4] 8852364
RCF2417SEA 24000 [7.0] 17000 [5.0] 7000 [2.1] 20.50 14.00 825 [389.4] 8930668
RA2024AJV R97VA070M317U
RCF2421MEA 23600 [6.9] 17200 [5.0] 6400 [1.9] 20.50 14.00 775 [365.8] 8852365
RCF2417SEA 24000 [7.0] 17000 [5.0] 7000 [2.1] 20.50 14.00 825 [389.4] 8930669
RA2024AJV R97VA085M521U RCF2421MEA 23800 [7.0] 17600 [5.2] 6200 [1.8] 20.00 14.00 825 [389.4] 8930672
RCF3621MEA 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.00 14.00 825 [389.4] 8930674
RA2036AJV R97VA060M317U RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 12.50 1200 [566.3] 8852371
RA2036AJV R97VA070M317U RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.00 12.20 1200 [566.3] 8930678
RA2036AJV R97VA085M521U RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 8852372
RA2036AJV R97VA100M521U RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 13.00 1225 [578.1] 8930507
RCF6021SEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 12.50 1225 [578.1] 8852373
RA2036AJV R97VA115M524U
RCF6024MEA 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 12.50 1225 [578.1] 8930509
RA2048AJV R97VA060M317U RCF6021SEA 44000 [12.9] 30200 [8.9] 13800 [4.0] 20.50 12.50 1200 [566.3] 8930683
RA2048AJV R97VA070M317U RCF6021SEA 43500 [12.7] 29700 [8.7] 13800 [4.0] 20.50 12.20 1200 [566.3] 8930684
RA2048AJV R97VA085M521U RCF6021SEA 44000 [12.9] 30700 [9.0] 13300 [3.9] 20.50 12.50 1300 [613.5] 8852378
RA2048AJV R97VA100M521U RCF6021SEA 44500 [13.0] 31500 [9.2] 13000 [3.8] 20.50 12.50 1350 [637.1] 8852379
RCF6021SEA 44500 [13.0] 31500 [9.2] 13000 [3.8] 20.50 13.00 1350 [637.1] 8852380
RA2048AJV R97VA115M524U
RCF6024MEA 46500 [13.6] 34000 [10.0] 12500 [3.7] 20.50 12.50 1575 [743.3] 8930686
RA2060AJV R97VA085M521U RCF6021SEA 55000 [16.1] 36700 [10.8] 18300 [5.4] 17.50 12.00 1550 [731.5] 8930513
RA2060AJV R97VA100M521U RCF6021SEA 55000 [16.1] 36700 [10.8] 18300 [5.4] 17.50 12.00 1550 [731.5] 8930514
RCF6021SEA 55500 [16.3] 38100 [11.2] 17400 [5.1] 17.50 11.70 1675 [790.5] 8930515
RA2060AJV R97VA115M524U
RCF6024MEA 56000 [16.4] 39800 [11.7] 16200 [4.7] 19.50 12.00 1675 [790.5] 8852383

Air Handler Ratings


Total Capacity Net Sensible Net Latent BTU/H Indoor
Outdoor Unit Air Handler SEER EER AHRI#
BTU/H [kW] BTU/H [kW] [kW] CFM [L/s]
RHMV2417SEAC 24000 [7.0] 17000 [5.0] 7000 [2.1] 20.50 14.00 825 [389.4] 8930675
RA2024AJV
RHMV2421HEAC 24000 [7.0] 17800 [5.2] 6200 [1.8] 20.50 14.00 825 [389.4] 8930676
RA2036AJV RHMV6024MEAC 36000 [10.6] 27100 [7.9] 8900 [2.6] 20.50 12.50 1225 [578.1] 8930679
RA2048AJV RHMV6024MEAC 47000 [13.8] 35200 [10.3] 11800 [3.5] 20.50 12.50 1675 [790.5] 8930687
RA2060AJV RHMV6021SEAC 56000 [16.4] 38200 [11.2] 17800 [5.2] 18.00 12.50 1625 [766.9] 8930516

[ ] Designates Metric Conversions

22
Guide Specifications
Air
RA20 Series

GUIDE SPECIFICATIONS
General AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER
System Description RA20
Outdoor-mounted, air-cooled, split-system air conditioner com- 1-1/2 TO 5 NOMINAL TONS
posite base pan unit suitable for ground or rooftop installation. Fans
Unit consists of a hermetic compressor, an air-cooled coil, — Condenser fan will be direct-drive propeller type, discharging
forward swept blade propeller-type condenser fan, suction and air upward.
legend line service valve, and a control box. Unit will discharge — Condenser fan motors will be totally enclosed, 1-phase type
supply air upward as shown on contract drawings. Unit will be with class B insulation and permanently lubricated bearings.
used in a refrigeration circuit to match up to a coil unit. Shafts will be corrosion resistant.
Quality Assurance — Fan blades will be statically and dynamically balanced.
— Unit will be rated in accordance with the latest edition of AHRI — Condenser fan openings will be equipped with coated steel
Standard 210. wire safety guards.
— Unit will be certified for capacity and efficiency, and listed in Compressor
the latest AHRI directory.
— Compressor will be hermetically sealed.
— Unit construction will comply with latest edition of ANSI/
ASHRAE and with NEC. — Compressor will be mounted on rubber vibration isolators.
— Unit will be constructed in accordance with UL standards and — Compressor will be covered with a sound absorbing blanket.
will carry the UL label of approval. Unit will have c-UL-us Condenser Coil
approval. — Condenser coil will be air cooled.
— Unit cabinet will be capable of withstanding ASTM B117 1000- — Coil will be constructed of aluminum fins mechanically bonded
hr salt spray test. to copper tubes.
— Air-cooled condenser coils will be leak tested at 150 psig and Refrigeration Components
pressure tested at 550 psig. — Refrigeration circuit components will include liquid-line shutoff
— Unit constructed in ISO9001 approved facility. valve with sweat connections, vapor-line shutoff valve with
Delivery, Storage, and Handling sweat connections, system charge of R-410A refrigerant, and
compressor oil.
— Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations. — Unit will be equipped with filter drier for R-410A refrigerant for
field installation.
Warranty (for inclusion by specifying engineer) — U.S. and
Canada only. Operating Characteristics
— The capacity of the unit will meet or exceed _____ Btuh at a
Products suction temperature of _____ °F/°C. The power consumption
at full load will not exceed _____ kW.
Equipment
— Combination of the unit and the evaporator or fan coil unit will
Factory assembled, single piece, air-cooled air conditioner unit.
have a total net cooling capacity of _____ Btuh or greater at
Contained within the unit enclosure is all factory wiring, piping,
conditions of _____ CFM entering air temperature at the evap-
controls, compressor, refrigerant charge R-410A, and special fea-
orator at _____ °F/°C wet bulb and _____ °F/°C dry bulb, and
tures required prior to field start-up.
air entering the unit at _____ °F/°C.
Unit Cabinet
— The system will have a SEER of _____ Btuh/watt or greater at
— Unit cabinet will be constructed of galvanized steel, bonder- DOE conditions.
ized, and coated with a powder coat paint.
Electrical Requirements
— All units constructed with louver coil protection and corner post.
— Nominal unit electrical characteristics will be _____ v, single
Louver can be removed by removing one fastener per louver
phase, 60 hz. The unit will be capable of satisfactory operation
panel.
within voltage limits of _____ v to _____ v.
— Nominal unit electrical characteristics will be _____ v, three
phase, 60 hz. The unit will be capable of satisfactory operation
within voltage limits of _____ v to _____ v.
— Unit electrical power will be single point connection.
— Control circuit will be 24v.
Special Features
— Refer to section of this literature identifying accessories and
descriptions for specific features and available enhancements.
— EcoNet control with appropriate software version is required
for full featured operation.

23
Limited Warranty
Air
RA20 Series

GENERAL TERMS OF LIMITED WARRANTY*


Rheem will furnish a replacement for any part of this product Conditional Unit Replacement
which fails in normal use and service within the applicable (Registration Required) ...............................Ten (10) Years
period stated, in accordance with the terms of the limited Parts ............................................................Ten (10) Years
warranty.
*For complete details of the Limited and Conditional Warranties, including
applicable terms and conditions, contact your local contractor or the
Manufacturer for a copy of the product warranty certificate.

24
Notes
Air
RA20 Series

25
Notes
Air
RA20 Series

26
Notes
Air
RA20 Series

27
The new degree of comfort.™

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1
Fort Smith, Arkansas 72917 • www.rheem.com Brampton, Ontario • L6Y 0P5

PRINTED IN U.S.A. 6/16 QG FORM NO. A11-224 REV. 1