IEMicro All-in-One Micro Data Center
IEMicro All-in-One Micro Data Center
➔
IEWATT, a micro data center manufacturer that dedicated into offering the all-
in-one edge computing non-IT Infrastructure. Based on industry-leading
technology in data center infrastructure, we strive to making the enclosure of
edge computing super-coverage.
Due to close to data user, With a professional team Edge means micro size
the edge computing data and advantage resource, and wide distribution,
center normally installed IEWATT combine and Instant means time and
beside or close to data optimize it, further more labor saving. All-in-one
user, in the meantime, the we’re concentrating on solution will save space
deployment are required one thing: and simplify all the process
to be rapid and simplified. from factory to end user,
The traditional pipe the ultimate goal is:
connection with cooling
will give a headache to
the customers: All-in-One Micro Data
Center
Space and complexity INSTANT EDGE
IEM Series is prefabricated; out-of-box; all-in-one micro data center for branch offices, small
offices and any non-IT space where there isn’t the room, reducing the time or the budget to
build a comms room. The out-of-the-box solution allows for IT deployment wherever and
whenever it is needed, the well-functioned intelligent monitoring High mobility and Simple
installation via plug-and-play speed the edge computing like our name: INSTANT EDGE
All-In-One Hardware- All data center critical infras prefabricated into one cabinet
Cabinet
42/45U Close Cabinet
IP55 Degree
DCIM
Intelligent Locker
IP55 degree
3-in-one:biometric;card;Pind
Integrated into monitoring for
remote or local administration
Thermal Management
3.9~12KW precise thermal
controlling cooling
EC fan and inverter
compressor
All-in-One Rack Mounted cooling Micro Data Center
Data Specifications
Model IEM03R IEM05R IEM7R
W*D*H=600/800mm*1200mm*2000m(42U Rack)
Dimension
800mm*1200mm*2200mm(45U Rack)
IP Degree IP55
Power Section
220V~230/50Hz/1Ph
Input Voltage
208-240V/60Hz/2Ph
DCIM
UPS; Power distribution; Coolling; Sensors; Access control;
Monitoring Items
All subsystems of micro data center are integrated
"0U“ space taken; SNMP avilable;RS485/232 serial ports expansion;
Monitoring Host CANBUS for expansion
All ports insulatation for protection and less interference
Remote Control and Management Via SNMP Via SNMP Via SNMP
Wireless Connection(Wifi) Optional Optional Optional
Centralized Management Optional Optional Optional
Cooling Section
Cooliing Capacity(KW) 3.9 5 7.5
Thermal Management
2.5~5.5KW Integrated
Precision cooling
Self-contained without
outdoor condenser
DCIM
3-in-one:biometric;card;Pind
Integrated into monitoring for
remote or local administration
Data Specifications
Model IEM02T IEM03T IEM06T
Type Self-Contained without outdoor unit
Available Space for IT
17U 26U 26U
(Default configuration)
Cooling and power Redundancy N N N
24U Height 33U Height 33U Height
Cabinet type
600mm*1200mm*33U) 600mm*1200mm*42U 600mm*1200mm*45U
Dimension(W*D*H)
24U Rack +9U cooling 33U Rack +9U cooling 33U Rack +12U cooling
IP Degree IP50
Power Section
220V~230/50Hz/1Ph
Input Voltage
208-240V/60Hz/2Ph
32/63/80A 2P 50/60HZ Input capacity optional
Optional N+1/2N Dual bus configuration
Intelligent Power Distribution Dual Bus for power redundancy
Independent DC source for sensors
SNMP/Modbus communicable
Rack Mounted Rack Mounted Rack Mounted
Defaulted UPS configuration
3KVA/3KW 6KVA/6KW 10KVA/10KW
Battery Type Lithum/Lead Acid Lithum/Lead Acid Lithum/Lead Acid
DCIM
UPS;Power distribution;Coolling; Sensors; Access contrl;
Monitoring Items
All subsystems of micro data center are integrated
"0U“ space taken; SNMP avilable;RS485/232 serial ports expansion; CANBUS for
Monitoring Host expansion
All ports insulatation for protection and less interference
Remote Control and Management Via SNMP Via SNMP Via SNMP
Wireless Connection(Wifi) Optional Optional Optional
Centralized Management Optional Optional Optional
Cooling Section
Cooliing Capacity(KW) 2.5 3.5 5.5
Sensible Capacity(KW) 2.5 3.5 5.5
Air Volumn(m³/s) 500 600 900
Mounted Type Top Mounted without outdoor unit
All-in-One Side Mounted cooling Micro Data Center
Cabinet
42/45U Close Cabinet
IP55 Degree
DCIM
Intelligent Locker
IP55 degree
3-in-one:biometric;card;Pind
Integrated into monitoring for
remote or local administration
Side cooling without outdoor condenser
Smart Power Distribution
N+1/2N dual bus configuration
With smart control core for
easy monitoring and detection
SNMP/Modbus communicative
Thermal Management
Specifications
Model IEM06S IEM07S IEM10S Big capacity above 10KW
Type Self-contained type without outdoor unit Split with outdoor unit
Available Space for IT
35U 35U 35U Customization
(Default configuration)
Dimension W*D*H=900/1100mm*1200mm*2000m
IP Degree IP55
Power Section
220V~230/50Hz/1Ph 380~415/50Hz/3Ph
Input Voltage
208-240V/60Hz/2Ph 208-240V/60Hz/3Ph
DCIM
UPS; Power distribution; Coolling; Sensors; Access contrl;
Monitoring Items
All subsystems of micro data center are integrated
"0U“ space taken; SNMP avilable;RS485/232 serial ports expansion; CANBUS for
Monitoring Host expansion
All ports isulatation for protection and less interference
Remote Control and Management Via SNMP Via SNMP Via SNMP Via SNMP
Wireless Connection(Wifi) Optional Optional Optional Optional
Centralized Management Optional Optional Optional Optional
Cooling Section
Cooliing Capacity(KW) 5.6 7.6 10 15/17/21/25/30KW optional
Sensible Capacity(KW) 5.6 7.6 10 15/17/21/25/30KW optional
Air Volumn(m³/s) 2000 2250 2400 Based on capacity
Heating Capacity (KW) 3
Humidification Capacity
Optional
(kg/h)
IERow-X+Y Rack Combo Solution
The IERow Series solution is a rapidly scalable one based on our All-in-one
Micro data center product, with the modular subsystem and the powerful DCIM
platform, this solution is totally born for the customization. We want to
formulate the single row solution free for every customer’s tailored requirement:
You finish the formula, we prefabricate!
Data Specifications
Model IERow-X+Y
Cooling Type Rack mounted or Side Mounted DX Type Split with outdoor unit
Available Space for IT
The Available space = X*42U — the space taken by UPS and power distribution
(Default configuration)
Cabinet type
42U 600/800mm
Dimension Customization based on combination
IP Degree IP55
Power Section
220V~230/50Hz/1Ph 380~415/50Hz/3Ph
Input Voltage
208-240V/60Hz/2Ph 208-240V/60Hz/3Ph
32/63/80A 2P 50/60HZ Input capacity optional
100/125A 3P 50/60HZ
Optional N+1/2N Dual bus configuration
Intelligent Power Distribution
Dual Bus for power redundancy
Independent DC source for sensors
SNMP/Modbus communicable
DCIM
UPS; Power distribution; Coolling; Sensors; Access contrl;
Monitoring Items
All subsystems of micro data center are integrated
"0U“ space taken; SNMP avilable;RS485/232 serial ports expansion; CANBUS for
Monitoring Host expansion
All ports isulatation for protection and less interference
Remote Control and Management Via SNMP Via SNMP Via SNMP Via SNMP
Wireless Connection(Wifi) Optional Optional Optional Optional
Centralized Management Optional Optional Optional Optional
Cooling Section
Cooliing Capacity(KW) Y*single unit capacity
Sensible Capacity(KW) Y*single unit capacity
Air Volumn(m³/s) Y*single unit capacity