SECTION – 3.

0
LIST OF ATTACHMENT
(GENERAL CIVIL) DOCUMENT NO.
TENDER PACKAGE FOR 220KV 6812-001-16-47-LL05 REV. 1
PERMANENT POWER SWITCH
YARD Page 1 of 6

LIST OF ATTACHMENT
(GENERAL CIVIL)
TENDER PACKAGE FOR 220KV PERMANENT
POWER SWITCH YARD

PROJECT: PUNJAB REFINERY PROJECT, BATHINDA


JOB NO.: 6812

CLIENT: M/s GURU GOBIND SINGH REFINERIES LTD.

1 28.08.07 REVISED AND REISSUED FOR BIDS JKU SKN SKN

0 03.07.07 ISSUED FOR BIDS JKU SKN NK


Rev. Prepared Checked Approved
Date Purpose
No by by by

Format No. EIL 1641-1924 Rev. 1 Copyright EIL – All rights reserved
SECTION – 3.0
LIST OF ATTACHMENT DOCUMENT NO.
(GENERAL CIVIL)
TENDER PACKAGE FOR 220KV 6812-001-16-47-LL05 REV. 1
PERMANENT POWER SWITCH
YARD Page 2 of 6

1.0 LIST OF ATTACHMENT

1.1 SCOPE OF WORK & SUPPLY

Sl. No of
Description Document no. Rev
No sheets
1 Scope of Work and Supply for 220 KV 6812-001-16-47- B 11
Construction Power Switch Yard.
SP05

1.2 JOB SPECIFICATION

Sl. No of
Description Document no. Rev
No sheets
1 Specification For High Velocity (HV) Water 6812-001-16-47- B 7
Spray System On Transformers. SP06
2 Piping Material Specification A94A & J2A. 6812-6-44-005 A 5+4

1.3 STANDARD SPECIFICATIONS

(TO BE READ IN CONJUNCTION WITH ADDENDUM TO THE


GENERAL CIVIL STANDARD SPECIFICATIONS LISTED IN DOCUMENT NO.
6812-001-16-47-SP05 AND 6812-001-16-47-SP06.)

Sl. Std. No of
Description Rev
No Specification no. sheets
1 Standard specification for shop & field painting. 6-44-0004 2 45
2 Valve material specification (Tag. No. 51321) 6-44-0006 5 1
3 Standard specification for fabrication and 6-44-0012 2 13
erection of piping
4 Standard specification for inspection, flushing 6-44-0013 2 9
and testing of piping systems.
5 Std spec for non - destructive examination 6-44-0016 4 19
requirement of requirement of piping
6 Standard specification for pressure testing of 6-44-0017 1 10
erected piping.
7 Technical notes for pipes. 6-44-0051 3 9
8 Technical notes for valves. 6-44-0052 4 11+7
9 Technical notes for flanges, spectacle blinds 6-44-0053 3 5
and drip rings.
10 Technical notes for butt welded, socket welded 6-44-0054 3 7
and screwed fittings.
11 Technical notes for gaskets. 6-44-0056 2 3
12 Technical notes for bolts and nuts. 6-44-0057 2 3
13 Standard specification for chain link fencing 6-65-0013 1 7

Format No. EIL 1641-1924 Rev. 1 Copyright EIL – All rights reserved
SECTION – 3.0
LIST OF ATTACHMENT DOCUMENT NO.
(GENERAL CIVIL)
TENDER PACKAGE FOR 220KV 6812-001-16-47-LL05 REV. 1
PERMANENT POWER SWITCH
YARD Page 3 of 6

Sl. Std. No of
Description Rev
No Specification no. sheets
14 Classification of soil for earthwork in site 6-65-0016 2 6
grading
15 Standard specification for Site Grading & rock 6-65-0017 3 12
cutting for site grading
16 Standard specification for road & flexible 6-65-0018 5 9
pavements. (Up to WBM layer)
17 Standard specification for flexible pavement 6812-6-65-0020 0 8
with bituminous macadam and bituminous
premix carpet
18 Standard specification for pipe culverts & ERC/ 6-65-0021 2 6
IRC crossing etc.
19 Standard specification for underground and 6-65-0027 2 4
above ground G.I. pipeline system (water
services)
20 Standard specification for fabrication and laying 6-65-0030 2 11
of piping
21 Standard specification for misc. civil & 6-65-0035 1 6
structural works for U/G piping & other civil
works.
22 Standard specification for underground sewer 6-65-0044 1 6
system - HDPE pipes.
23 Standard specification for plumbing & building 6-65-0053 1 10
drainage.
24 Standard specification for general civil works 6-65-0066 1 12
(package unit).
25 Standard specification for earthwork for 6-65-1006 1 7
underground piping
26 Standard specification for gravel filling 6-65-1024 1 5
27 Standard specification for underground C.I. 6-65-1036 1 7
piping system.
28 Standard specification for underground sewer 6-65-1042 1 6
system - pre cast R.C.C. pipes.
29 Standard specification for portable CO2 type 6-66-0003 1 3
extinguisher.
30 Standard specification for portable dry powder 6-66-0006 1 4
type extinguisher.
31 Standard Spec. for stand post type fire hydrant 6-66-0012 2 5
(with or without pumper connection)
32 Standard specification for water spray nozzle 6-66-0046 1 5
assembly for cooling.
33 Standard specification for deluge valve. 6-66-0048 1 8
34 Technical specification - civil & structural works 6-68-0004 3 32
- plain & reinforced cement concrete
35 Technical specification - civil & structural works 6-68-0006 4 24
- structural steel works.
36 Technical specification- civil & structural works 6-68-0008 4 12
- miscellaneous steel works.

Format No. EIL 1641-1924 Rev. 1 Copyright EIL – All rights reserved
SECTION – 3.0
LIST OF ATTACHMENT DOCUMENT NO.
(GENERAL CIVIL)
TENDER PACKAGE FOR 220KV 6812-001-16-47-LL05 REV. 1
PERMANENT POWER SWITCH
YARD Page 4 of 6

Sl. Std. No of
Description Rev
No Specification no. sheets
37 Welding specification for fabrication of piping. 6-77-0001 2 29
38 Welding specification charts for piping classes. 6-77-0005 4 5
39 Standard spec. for corrosion protection 6-79-0011 0 14
tape coating for underground steel piping.

1.4 CONSTRUCTION STANDARDS

(TO BE READ IN CONJUNCTION WITH ADDENDUM TO THE


GENERAL CIVIL CONSTRUCTION STANDARDS LISTED IN DOCUMENT NO.
6812-001-16-47-SP05.)

Sl. Construction No of
Description Rev
No Standard No. sheets
1 Stub-in standard. 7-44-0032 2 2
2 Details of mitered elbow. 7-44-0033 3 2
3 Vents and drains (on lines 2" and above). 7-44-0351 2 1
4 Welding of pipe with different thickness. 7-44-0476 2 1
5 Butt welding end preparation. 7-44-0477 2 1
6 Fillet weld details. 7-44-0478 2 1
7 Welding details for branch connections. 7-44-0479 2 1
8 Butt-weld details. 7-44-0480 2 1
9 Welding detail for branch connections (stub in). 7-44-0482 2 1
10 Branch connection (not breaking into). 7-44-0484 2 1
11 Tolerances for fabrication. 7-44-0486 2 1
12 Cable crossing under road (PVC pipe) 7-65-0006 2 1

13 Road curves and crossings. 7-65-0010 3 1

14 Standard Section of storm water drains. 7-65-0101 4 1


15 Concrete trapezoidal storm water drain. 7-65-1-0102 2 1
16 Pipe Culvert for storm water storm water 7-65-0103 1 3
drainage.
17 Details of rungs for manholes, valve pits, tanks, 7-65-0211 2 1
etc.
18 Concrete bedding and encasements for pipes 7-65-0213 2 1
19 Gully trap chamber. 7-65-0214 3 1
20 Inspection chamber. 7-65-0215 2 1
21 Septic tank type I, II & III. 7-65-0216 3 1

Format No. EIL 1641-1924 Rev. 1 Copyright EIL – All rights reserved
SECTION – 3.0
LIST OF ATTACHMENT DOCUMENT NO.
(GENERAL CIVIL)
TENDER PACKAGE FOR 220KV 6812-001-16-47-LL05 REV. 1
PERMANENT POWER SWITCH
YARD Page 5 of 6

Sl. Construction No of
Description Rev
No Standard No. sheets
22 Details of soak pit. 7-65-0217 3 1
23 Valve pit type-1 for dia.
1½". 7-65-0220 3 1
24 Detail of neutralization pit. 7-65-0310 1 1
25 Concrete Sliding Sleepers Cast-in-situ Type - 7-65-0407 4 1
II.
26 Concrete Sliding Sleepers Cast-in-situ Type - 7-65-0408 4 1
III.
27 Steel gate for entrance. 7-75-0054 3 1
28 Instruction to Turnkey contractor for 7-76-0102 0 9
routing and review of documents.

1.5 DRAWINGS

Sl.
Description No.
No.
1 Overall plot plan of Bathinda Refinery 6812-000-16-47-0001
2 Scope Drawing for 220 KV out door Switch 6812-000-16-47-3034 REV. A
Yard.
3 Cross-section of road. 6812-000-16-47-3912 REV. A
4 Detail of Chain Link Fencing 6812-000-16-47-3031 REV. B
5 Installation details of fire water hydrant, water 6812-000-16-47-3035 Rev. 1
monitor and foam/water monitor.

1.6 DATA SHEETS

Sl. No of
Description Data Sheet No. Rev
No sheets
1 Data Sheets for Spray Nozzle (HV). 6812-001-16-47-DS-11 0 1
2 Data Sheet for QBD. 6812-001-16-47-DS-12 0 1
3 Data Sheets for Double Headed water 6812-001-16-47-DS-13 0 1
hydrant

1.7 INSPECTION TESTING PLAN

Sl. No of
Description Specification no. Rev
No sheets
1 Underground Piping Works 6-82-2706 0 5
(RCC/CI)
2 WBM Roads 6-82-2707 0 5
3 Black Topping (Premix Carpeting) 6-82-2708 0 5
4 Micro Grading 6-82-2710 0 5

Format No. EIL 1641-1924 Rev. 1 Copyright EIL – All rights reserved
SECTION – 3.0
LIST OF ATTACHMENT DOCUMENT NO.
(GENERAL CIVIL)
TENDER PACKAGE FOR 220KV 6812-001-16-47-LL05 REV. 1
PERMANENT POWER SWITCH
YARD Page 6 of 6

Sl. No of
Description Specification no. Rev
No sheets
5 Underground Piping (Carbon 6-82-2740 0 10
Steel)

1.8 APPROVED VENDOR LIST

Sl. No of
Description Data Sheet No. Rev
No sheets
1 Vendor list for HV spray system for 6812-001-16-47-VR-06 A 8
Transformer

Format No. EIL 1641-1924 Rev. 1 Copyright EIL – All rights reserved