OEG Service Information Hard Disk Initialization Method For DNC-DT Function

1) The document discusses when hard disk initialization is necessary for the DNC-DT function after upgrading software versions on OSP-7000M/U100M and OSP-E100M CNC machines. 2) Hard disk initialization is required when upgrading the DNC software package from versions older than V615A to V620A or newer on OSP-7000M/U100M, and from versions older than V700X to V701A or newer on OSP-E100M. 3) The document provides instructions for performing hard disk initialization, which takes about 30 minutes to complete.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
255 views

OEG Service Information Hard Disk Initialization Method For DNC-DT Function

1) The document discusses when hard disk initialization is necessary for the DNC-DT function after upgrading software versions on OSP-7000M/U100M and OSP-E100M CNC machines. 2) Hard disk initialization is required when upgrading the DNC software package from versions older than V615A to V620A or newer on OSP-7000M/U100M, and from versions older than V700X to V701A or newer on OSP-E100M. 3) The document provides instructions for performing hard disk initialization, which takes about 30 minutes to complete.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

1/2

OEG Doc. No SIE200-007-0


Date: 19.02.2003
OEG Service Information

Hard disk Initialization Method for DNC-DT function

<< Outline >>


When the “DNC PACKAGE” of OSP-7000M/U100M/E100M takes software version up according to
Retro-fit/Countermeasure, it is necessary to execute Hard disk Initialization again for DNC-DT
function.
However, it depends on the software versions as below; Because the HARD DISK FORMAT form is
different from software versions to new ones.

Only if the following version-up is done, the hard disk Initialization is necessary.

<OSP-7000M/U100M>
When the software version of DNC PACKAGE is up-graded from V615A or older to V620A or newer.
• V615A software is applied on the DNC PACKAGE; “DNCB000AENG-012” or older.
• V620A software is applied on the DNC PACKAGE; “DNCB000AENG-013” or newer.

<OSP-E100M>
When the software version of DNC PACKAGE is up-graded from V700X or older to V701A or newer.

The software versions are possible to be confirmed at OSP MANAGEMENT CARD as below.
EX)OSP-U100M
V615A version or older V620A version or newer
 [ DNC package ] [ DNC package ]

DNCB000AENG-012 DNCB000AENG-013

 FR0F:DNP0615A-1-ENG.MSG FR0F:DNP0620A-1-ENG.MSG
 FR0F:DNP0615A-2-ENG.MSG FR0F:DNP0620A-2-ENG.MSG

FR0F:DNPC615A-1.POL FR0F:DNPC620A-1.POL

 FR0F:DNPC615A-2.POL Version up FR0F:DNPC620A-2.POL
 FR0F:DNPC615A-3.POL FR0F:DNPC620A-3.POL

FR0F:DNTC615A-3.POL FR0F:DNTC620A-1.POL

FR0F:DNTC615A-4.POL FR0F:DNTC620A-2.POL

 FR0F:PEDT0220A-ENG.MSG FR0F:DNTC620A-3.POL
 FR0F:PEDTC220A.POL FR0F:DNTC620A-4.POL

FR0F:DNCB201A.POL FR0F:PEDT0220A-ENG.MSG

 FR0F:DNCC201A.POL FR0F:PEDTC220A.POL
FR0F:SAHD300A.ADD FR0F:DNCB201A.POL
FR0F:SFSC200A.POL FR0F:DNCC201A.POL
FR0F:TCPA233A.POL FR0F:SAHD300A.ADD

Any technical information is subject to change without notice.


Okuma Europe GmbH
Original Written by:
Original Doc. No.: SIE200-007-0 Hard disk Initialization Method for DNC-DT function.doc
2/2

OEG Doc. No SIE200-007-0


Date: 19.02.2003
OEG Service Information

(Information)
- OSP7000M/U100M is possible to be confirmed at DNC PACKAGE floppy disk.
However, OSP-E100 is unnecessary to be checked by OSP MANAGEMENT CARD due the
software is in CD-R.
- If an above method isn’t done with an above software version up, the following alarm happen with
program selection of DNC-DT function.
Ex) U100M
5427 DNC-DT Program Selection 16

<< Initialization Method >>

-Hard disk initialization takes about 30 minutes. (It depends on the hard
disk capacity)
-Please note that CTRL-C doesn’t stop the initialization after it is started,
and don’t turn off the power of machine during initialization.
-The initialization is impossible if the following error occurs during
program selection with DNC-DT.
5428 Hard Disk Initialization Error FF
In this case, please wait to finish the program selection.

<OSP-7000M/U100M>

- Select program operation mode; EDIT AUX.


- Input “HDINIT”, then press the WRITE key.
- When the “=” indication appear at consol line, the operation is completed.

<OSP-E100M>

- Select program operation mode; EDIT AUX.


- Find “INIT” indication at [F3] by pressing the extend key.
- Press the [F3](INIT).
- Press the [F5](HDINIT).
- When the initialization window is closed, the operation is completed.