Design Constants: Load On Slab
Design Constants: Load On Slab
Design of Tank
Storage Capacity is = 6.93x 5.62 x 0.9
= 35.02 Cum
L/B = 1.23 L/H = 7.7 B/H = 6.24
L/H and B/H are greater than 2
Hence the walls span in Vertical direction
since the tank is closed one the walls act as proped cantilevers.
Roof Slab
Slab thickness assumed is = 125 mm
clear cover taken as = 20 mm
assumed dia of bar = 8 mm
where effective depth = 101 mm
The panel size is ly = 4.96
lx = 4.12
ly/lx = 1.21
Density of concrete = 25 KN/m3
Load On slab
self weight = 3.125
Floor finish = 1.5
Live Load = 1.5
Total Load on Slab = 6.125 KN/m2 ~ 6.20 KN/m2
Considering the slab as One long edge continuous
As per code IS 456
Short span -ve moment -αx= 0.071 Mx = αxwlx2 = 7.459 KN-m
2
Short span +ve moment +αx= 0.053 Mx = αxwl x = 5.594 KN-m
2
Long span -ve moment -αy= 0.000 My = αywl x = 0.000 KN-m
2
Long span +ve moment +αy= 0.044 My = αywl x = 4.567 KN-m
Ast required Ast provided
Ast for Short span -ve moment = 175.9 8 286 c/c 200 c/c
Ast for Short span +ve moment = 150.0 8 335 c/c 200 c/c
Ast for Long span -ve moment = 150.0 8 335 c/c 200 c/c
Ast for Long span +ve moment = 150.0 8 335 c/c 200 c/c
d = 298.27 mm
Provide Overall depth = 750 mm
clear cover = 30 mm
dia of bar = 20 mm
effective depth = 700 mm
Area of steel required shorter span = M
σst x j x d
Ast = = 612.84 mm2
Provide 2-#16st +2-#16 ext at top and 2-#16 st +2-#16 ext at bottom
d = 239.70 mm
Provide Overall depth = 600 mm
clear cover = 30 mm
dia of bar = 20 mm
effective depth = 550 mm
Area of steel required shorter span = M
σst x j x d
Ast = = 503.74 mm2
Provide 2-#20st +3-#20 ext at top and 2-#20st +3-#20 ext at bottom
B3 span = 3.50 m
wall thickness taken as = 0.175 m
height of wall taken as = 1.50 m
thickness of beam = 0.23 m
depth of beam = 0.475 m
d = 367.97 mm
Provide Overall depth = 475 mm
clear cover = 30 mm
dia of bar = 20 mm
effective depth = 425 mm
Area of steel required shorter span = M
σst x j x d 17.45
Ast = = 1177.83 mm 2