Wilo General Overview 201: Efficient Solutions - 50 HZ
Wilo General Overview 201: Efficient Solutions - 50 HZ
Hz
DISCOVER
ADDITIONAL
DIGITAL
CONTENT
NOW.
PUMP TECHNOLOGY
OF THE FUTURE.
WILO-STRATOS MAXO,
THE WORLD´S FIRST SMART-PUMP*.
Water supply.........................................................................................................28 – 49
Intelligent technologies to combat water shortages.
* We understand a smart-pump as a new category of pumps, which goes far beyond our high-efficiency pumps or pumps with pump intelligence. Only the
combination of the latest sensor technology and innovative control functions (e.g. Dynamic Adapt plus and Multi-Flow Adaptation), bidirectional connectivity
(e.g. Bluetooth, integrated analogue inputs, binary inputs and outputs, Wilo Net interface), software updates and excellent usability (e.g. thanks to the Setup
Guide, the preview principle for predictive navigation and the tried and tested Green Button Technology) make this pump a smart-pump.
4 Wilo – Technology of the future
SMART SOLUTIONS
FOR A BETTER TOMORROW.
Wilo is a premium supplier for building services, water Big data is the valuable raw material of digitalisation and
management and industrial applications. We make complex we harness its power. To tap the incredible potential of this
technologies user-friendly, simple to operate, energy- exponential resource, we are transforming our processes
efficient and powerful for our customers. In the end, the in the digital world – for forward-looking, networked and
main focus of everything we do is people. We offer them varied results. We analyse relevant data and conduct spe-
outstanding products, system solutions and services. cific evaluations. Based on the systematic assessment of
Founded in Dortmund in 1872 as a factory for copper and existing data, we develop new business models as well as
brass goods, Wilo has evolved from being a local specialist customised digital product features for our pumps, applica-
to a global player in the course of its long and successful tions and services.
history.
We do it all with a precise objective: through the intelli-
We are well-acquainted with questions that will shape our gent networking of people, products, services, factories
future and we develop technologies that provide answers. and machines, we effectively harness the potential of
Global megatrends are having a profound and lasting im- digitalisation to create smart solutions. Every day, around
pact on our lives. As we address these trends, we concen- 7,600 employees worldwide work to make that claim a real-
trate on globalisation, urbanisation, climate change, energy ity. At 16 production sites in more than 60 subsidiaries in
shortage, water shortage as well as digital transforma- 60 countries. The result: pioneering new products, systems
tion – important issues for your day-to-day work. Which and services. Making life easier for our customers and the
makes them important to us, too. future a better place.
INNOVATIONS
FOR A BRAND-NEW WORLD.
Megatrend – it’s a common buzzword. But what exactly In a globalised world, the economy is growing at an incred-
does it mean? Megatrends change the world. Lasting and ible pace – and with it middle class consumers and their
profound in their effect, they are often closely related and purchasing power. Competition for raw materials and re-
reciprocally linked in their development. The influence of sources is intensifying. Energy shortage and water short-
megatrends extends throughout all areas of our lives: from ages are two major consequences. In addition, outdated
society, economy and politics to science, technology and power infrastructures, growing water pollution and highly
culture. Wilo identified six megatrends that are especially inefficient usage patterns aggravate the situation. That is
important to you as our customers and therefore to us in why Wilo focuses on developing both flexible, high-
our work: efficiency solutions that adapt to their environment and
ƒƒ Globalisation highly efficient technologies that conserve resources. Our
ƒƒ Energy shortage development activities consider the entire process from
ƒƒ Water shortage energy production or water purification to transportation
ƒƒ Urbanisation and consumption. Our innovative products let you satisfy
ƒƒ Climate change requirements for high system efficiency and the sustaina-
ƒƒ Digital transformation ble use of precious resources.
We engage intensely with these six trends to study their
effects and develop solutions that make the future a better Ultimately, the efficient use of energy and water is becom-
place and enhance the quality of life. ing more and more important everywhere you look. This
is especially true since urbanisation continues as a steady
One cross-cutting megatrend that has brought many more trend and worldwide the number of megacities with more
changes is globalisation. We all feel its effects, most of all than ten million inhabitants continues to grow. In these
at the workplace. The worldwide availability of products, increasingly dense urban centres, supplying clean water
information, services, raw materials, technologies and pro- to private households as well as industry and agriculture
cedures has heightened competition. Wilo develops solu- has been a major challenge for some time. How can the
tions that give you an edge in regional and local markets. demand for fresh water be reduced? And how can water
And in turnkey quality, since our distributed production purification be made as efficient as possible in terms of
network enables short delivery routes for our customers capacity and energy consumption?
around the world.
Wilo – Technology of the future
7
We offer a wide variety of intelligent pumps and systems to make our users’ everyday lives
simply more pleasant. Our energy-efficient solutions are suitable for residential, public
and commercial properties. Wilo products are used in heating, air conditioning, cooling and
water supply applications as well as for drainage and sewage.
Wilo – Technology of the future
1 H
EATING, AIR CONDITIONING, COOLING
Wilo delivers individual solutions and highly efficient
technology for applications in heating, air conditioning,
cooling and domestic hot water.
2 W
ATER SUPPLY
Innovative products and systems from Wilo support
applications in rainwater utilisation, water supply and
pressure boosting, firefighting and raw water intake.
3 D
RAINAGE AND SEWAGE
Wilo pumps and lifting units ensure safe and reliable
operation in wastewater and sewage disposal.
NETWORKED SOLUTIONS
FOR AN OPTIMAL INDOOR
CLIMATE.
PUMPS AND SYSTEMS FOR HEATING, AIR CONDITIONING,
COOLING AND DOMESTIC HOT WATER.
Photo: DFM/Hannappel.
Courtesy of DFB-Stiftung Deutsches Fußballmuseum gGmbH.
11
VERSATILE
Our solutions make it possible to supply various types of
buildings with a pleasant indoor climate and domestic hot
water. From single-family houses to rental, administrative
and commercial properties such as hospitals, office spaces
or hotels.
Product range Glandless premium high-efficiency Glandless standard high-efficiency Glandless standard high-efficiency
pumps pumps pumps
Field of application Heating, air conditioning, cooling Heating, air conditioning, cooling Heating, air conditioning, cooling
Duty chart H/m Wilo-Stratos PICO H/m Wilo-Yonos PICO H/m Wilo-Yonos PICO-D
6 7 8
25, 30/1-8 7
5 6
15, 25, 6
5
4 5
30/1-6 4
15, 25, 30
3 /1-6 4
3 Yonos PICO-D
2 3
15, 25, 30/1-4 2 2
1 1 15, 25, 30/1-4 1
0 0 0
0 1 2 3 4 Q/m³/h 0 1 2 3 4 Q/m³/h 0 1 2 3 4 5 Q/m³/h
Design Glandless circulation pump with screwed Glandless circulation pump with screwed Glandless circulation pump with screwed
connection, EC motor and automatic connection, EC motor and automatic connection, EC motor and automatic
power adjustment power adjustment power adjustment
Application Hot-water heating systems of all kinds, Hot-water heating systems of all kinds, Hot-water heating systems of all kinds,
air-conditioning applications, industrial air-conditioning applications, industrial air-conditioning applications, industrial
circulation systems circulation systems circulation systems
Special features ƒƒ Maximum energy efficiency thanks ƒƒ Maximum set-up comfort with new ƒƒ LED display for setting the setpoint
to the combination of the EC motor, smart settings, self-explanatory inter- in 0.1 m steps and for showing the
Dynamic Adapt and precise settings face and new functions current consumption
ƒƒ High reliability through self-protecting ƒƒ Optimised energy efficiency thanks to ƒƒ Tool-free electrical connection using
automatic routines EC motor technology, precise settings the Wilo-Connector
ƒƒ Intuitive setting/maintenance by by 0.1 m ƒƒ Unique pump venting function per
activating functions and modes shown ƒƒ Quick installation/replacement thanks pump
on LC display to the improved compact design ƒƒ Double pump for individual (Δp-c and
ƒƒ Monitoring of current power con- ƒƒ Easier maintenance due to automati- Δp-v) or parallel operation (Δp-c)
sumption or flow and cumulated kWh cally and manually activated restart or ƒƒ Very high starting torque for safe
ƒƒ Tool-free electrical connection using air venting function start-up
the Wilo-Connector ƒƒ Maximum reliability and operational
safety thanks to proven technology
Technical data ƒƒ Fluid temperature +2 °C to +110 °C ƒƒ Fluid temperature -10 °C to +95 °C ƒƒ Fluid temperature -10 °C to +95 °C
ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection 1~230 V, 50 Hz
ƒƒ Energy Efficiency Index (EEI) ≤ 0.20 ƒƒ Energy Efficiency Index (EEI) ≤ 0.20 ƒƒ Energy Efficiency Index (EEI) ≤ 0.20
ƒƒ Screwed connection Rp ½, Rp 1, Rp 1¼ ƒƒ Screwed connection Rp ½, Rp 1, Rp 1¼ ƒƒ Screwed connection Rp 1¼
ƒƒ Max. operating pressure 10 bar ƒƒ Max. operating pressure 10 bar ƒƒ Max. operating pressure 6 bar
Equipment/function ƒƒ Control mode: Δp-c and Δp-v (Dy- ƒƒ Control mode: Δp-c, Δp-v and con- ƒƒ Control mode: Δp-c and Δp-v
namic Adapt) stant speed (3 curves) ƒƒ Setting of delivery head
ƒƒ Automatic setback operation ƒƒ Setting the operating mode by appli- ƒƒ Automatic venting function
ƒƒ Automatic venting routine cation ƒƒ Automatic deblocking function
ƒƒ Automatic restart and dry running ƒƒ Setting of delivery head or constant ƒƒ Main/standby mode and parallel
detection speed operation
ƒƒ Display of the current power con- ƒƒ Automatic deblocking function ƒƒ LED display for setting the setpoint
sumption or flow and cumulative kWh ƒƒ Manual re-start and venting function and displaying actual consumption
ƒƒ Reset function for the electricity meter ƒƒ LED display for setting the setpoint ƒƒ Wilo-Connector
or to factory settings and displaying actual consumption
ƒƒ Hold function (Key lock) ƒƒ Wilo-Connector
ƒƒ Wilo-Connector ƒƒ Options: port-to-port length 130 mm
ƒƒ Options: stainless steel pump housing;
port-to-port length 130 mm
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
13
Product range Glandless standard high-efficiency Glandless standard high-efficiency Glandless premium smart pumps
pumps pumps
Field of application Heating, air conditioning, cooling Heating, air conditioning, cooling Heating, air conditioning, cooling
Duty chart H/m Wilo-Varios PICO H/m Wilo-Yonos ECO BMS H/m Wilo-Stratos MAXO
7 16
5 Wilo-Stratos MAXO-D
6 14
5 4 12
3 10
4
8
3
Varios PICO 15,25/1-7 2 6
2 Yonos ECO 25, 30/1-5 BMS Stratos MAXO Stratos MAXO-D
4
1 1
2
0 0 0
0 1 2 3 Q/m³/h 0 0,5 1,0 1,5 2,0 2,5 Q/m³/h 0 20 40 60 80 100 Q/m³/h
Design Glandless circulation pump with screwed Glandless circulation pump with screwed Smart glandless circulator with screwed
connection, EC motor and automatic connection, EC motor and automatic connection or flange connection, EC mo-
power adjustment power adjustment tor with integrated power adjustment
Application Hot-water heating systems of all kinds, Hot-water heating systems of all kinds, Hot-water heating systems of all kinds,
air-conditioning applications, industrial air-conditioning systems, closed cooling air-conditioning systems, closed cooling
circulation systems circuits, industrial circulation systems circuits, industrial circulation systems
Special features ƒƒ A highly compatible replacement ƒƒ Potential-free collective fault signal ƒƒ Intuitive operation by guided applica-
solution for all applications thanks (SSM) for connection to external moni- tion settings with the Setup Guide
to compact dimensions, new control toring unit (e.g. building automation) ƒƒ Optimised energy-saving functions
modes e.g. iPWM and the new Sync and control input 0-10 V such as No-Flow Stop
function ƒƒ Control cable (4-core, 1.5 m) for ƒƒ Innovative and intelligent controlling
ƒƒ Highest comfort in handling with one connecting SSM and 0-10 V functions such as Dynamic Adapt plus
push button for control mode and one ƒƒ Wilo-Connector and Multi-Flow Adaption
for preset curves and the LED-display ƒƒ Thermal insulation as standard ƒƒ Bluetooth interface for connection
ƒƒ Easy installation through adaptable ƒƒ Pump housing with cataphoretic to mobile devices and direct pump
connections and maintenance func- coating protects against corrosion due networking for multiple pump control
tions like air venting to condensation formation via Wilo Net
ƒƒ Highest reliability and operational ƒƒ Maximum electric installation comfort
safety thanks to proven technology by the optimised Wilo-Connector
Technical data ƒƒ Fluid temperature -10 °C bis +95 °C ƒƒ Fluid temperature -10 °C to +110 °C ƒƒ Fluid temperature -10 °C to +110 °C
ƒƒ Mains connection: 1~230 V, 50 Hz ƒƒ Mains connection: 1~230 V, 50 Hz ƒƒ Mains connection: 1~230 V, 50 Hz
ƒƒ Energy Efficiency Index (EEI) ≤ 0,20 ƒƒ Energy Efficiency Index (EEI) ≤ 0.20 ƒƒ Nominal diameter Rp 1 to DN 100
ƒƒ Screwed connection Rp ½, Rp 1 ƒƒ Screwed connection Rp 1, Rp 1¼ ƒƒ Max. operating pressure 10 bar (special
ƒƒ Max. operating pressure 10 bar ƒƒ Max. operating pressure 10 bar version: 16 bar)
Equipment/function ƒƒ Control mode: Δp-c, Δp-v and con- ƒƒ Control modes: Δp-c, Δp-v and manu- ƒƒ Control mode: Dynamic Adapt plus,
stant speed al control mode (n = constant) ∆p-c, ∆p-v, n-const, T-const,
ƒƒ External control (PWM and iPWM) ƒƒ Control input “Analog In 0 - 10 V” ∆T-const and Q-const
ƒƒ Sync function (manual manual pro- (remote speed control) ƒƒ Automatic switch-off the pump with
gramming mode) ƒƒ Collective fault signal (potential-free No-Flow Stop
ƒƒ Air venting function NC contact) ƒƒ Multi-Flow Adaptation
ƒƒ Manual re-start ƒƒ Control cable (4-core, 1.5 m) for con- ƒƒ Remote control via Bluetooth interface
ƒƒ LED display and 2 push buttons for necting SSM and 0-10 V ƒƒ Selection of application range with
settings and functions activation ƒƒ Wilo-Connector Setup Guide
ƒƒ Dual electrical connection (Molex and ƒƒ Deblocking function ƒƒ Heat and cold metering
Wilo-Connector) ƒƒ Dual pump management
ƒƒ Front access to motor screws ƒƒ Retrofitable interface modules for
communication
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
14 Heating, air-conditioning, cooling
IE
Series extension
Product range Glandless premium high-efficiency Glandless standard high-efficiency Glanded high-efficiency pumps in in-
pumps pumps line design
Field of application Heating, air conditioning, cooling Heating, air conditioning, cooling Heating, air conditioning, cooling, indus-
trial process
Duty chart H/m Wilo-Stratos H/m Wilo-Yonos MAXO, H/m Wilo-Stratos GIGA
16 Wilo-Stratos-D 16 70
Wilo-Yonos MAXO-D
14 14 60
12 12
Yo 50
10 10 Yon nos M 40
8 8 o s AX
MA O
6 6 XO 30
-D
Stratos Stratos-D 20
4 4
2 2 10
0 0 0
0 10 20 30 40 50 60 70 80 90Q/m³/h 0 4 8 12 16 20 24 28 32 36 40 44 48 Q/m³/h 0 50 100 150 200 250 300 Q/m³/h
Design Glandless circulator with screwed con- Glandless circulator with screwed con- High-efficiency in-line pump (as single or
nection or flange connection, EC motor nection or flange connection, EC motor double pump) with EC motor, electron-
and automatic power adjustment and automatic power adjustment ically controlled, in glanded design with
flange connection and mechanical seal
Application Hot-water heating systems of all kinds, Hot-water heating systems of all kinds, Pumping of heating water, cold water and
air-conditioning systems, closed cooling air-conditioning systems, closed cooling water-glycol mixtures without abrasive
circuits, industrial circulation systems circuits, industrial circulation systems substances in heating, cold water and
cooling systems
Special features ƒƒ Energy savings through greater system ƒƒ LED display for indication of set deliv- ƒƒ Innovative high-efficiency pump for
efficiency with the Q-Limit function ery head and fault codes maximum overall efficiency
ƒƒ Improved Energy Efficiency Index (EEI) ƒƒ Quick setting when replacing an un- ƒƒ High-efficiency EC motor with effi-
≤0.20 for all single pumps. controlled standard pump with pre-set ciency class IE5 acc. IEC 60034-30-2
ƒƒ Optimised display for better readability speed stages, e.g. TOP-S ƒƒ Optional IF-module interfaces for
ƒƒ Space-saving installation due to com- ƒƒ Electrical connection with Wilo plug bus communication with building
pact design and location-dependent ƒƒ Collective fault signal ensures system automation
LC display availability
ƒƒ Retrofitable interface modules for ƒƒ Pump housing with cataphoretic (KTL)
communication (e.g. Modbus, BACnet, coating protects against corrosion due
CAN, LON and PLR) to condensation
ƒƒ Tried and tested quality and reliability
Technical data ƒƒ Fluid temperature -10 °C to +110 °C ƒƒ Fluid temperature -20 °C to +110 °C ƒƒ Fluid temperature -20 °C to +140 °C
ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection: 3~380 V - 3~480 V
ƒƒ Energy Efficiency Index (EEI) ≤ 0.20 ƒƒ Energy Efficiency Index (EEI) ≤ 0.20 (±10 %), 50/60 Hz
(EEI ≤ 0.23 for double pumps) (EEI ≤ 0.23 for double pumps) ƒƒ Minimum efficiency index (MEI) ≥ 0.7
ƒƒ Nominal diameter Rp 1 to DN 100 ƒƒ Nominal diameter Rp 1 to DN 100 ƒƒ Nominal diameter DN 40 up to DN 100
ƒƒ Max. operating pressure 10 bar (special ƒƒ Max. operating pressure 10 bar ƒƒ Max. operating pressure 16 bar
version: 16 bar)
Equipment/function ƒƒ Control modes: ∆p-c, ∆p-v, ∆p-T ƒƒ Control modes: Δp-c, Δp-v, 3 speed ƒƒ Control modes: Δp-c, Δp-v, PID con-
ƒƒ Volume flow limitation with Q-Limit stages trol, n=constant
function (via IR-Stick) ƒƒ LED display for setting the required ƒƒ Manual functions: E.g. differential
ƒƒ Automatic setback operation delivery head pressure setpoint setting, manual con-
ƒƒ Dual pump management ƒƒ Quick electrical connection with Wilo trol mode, error acknowledgement
ƒƒ Graphical pump display plug ƒƒ External control functions: E.g
ƒƒ Remote control via infrared interface ƒƒ Motor protection, fault signal light and Overriding Off, external pump cycling
(IR-Stick/IR-Monitor) contact for collective fault signal (double pump operation), analogue
ƒƒ Retrofitable interface modules for ƒƒ Combination flanges PN 6/PN 10 (for input 0-10 V/0-20 mA for constant
communication DN 40 to DN 65) speed (DDC)
ƒƒ Combination flanges PN 6/PN 10 ƒƒ Remote control via infrared interface
(DN 32 to DN 65) (IR-Stick/IR-Monitor), plug-in position
for IF-Modules for connection to
building automation
ƒƒ Safety functions
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
15
IE
Series modification
Product range Glanded high-efficiency pumps in mon- Glanded energy-saving pumps in in-line Glanded energy-saving pumps in in-line
obloc design design design
Field of application Heating, air conditioning, cooling, indus- Heating, air conditioning, cooling, indus- Heating, air conditioning, cooling, indus-
trial process trial process trial process
Application Pumping of heating water, cold water and Pumping of heating water, cold water and Pumping of heating water, cold water and
water-glycol mixtures without abrasive water-glycol mixtures without abrasive water-glycol mixtures without abrasive
substances in heating, cold water and substances in heating, cold water and substances in heating, cold water and
cooling systems cooling systems cooling systems
Special features ƒƒ Innovative high-efficiency pump for ƒƒ Energy savings due to integrated ƒƒ Energy savings due to integrated
maximum total-system efficiency, electronic control electronic control
with principal dimensions in accord- ƒƒ Optional interfaces for bus communi- ƒƒ Optional interfaces for bus communi-
ance with EN 733 cation using plug-in IF-Modules cation using plug-in IF-Modules
ƒƒ High-efficiency EC motor (efficiency ƒƒ Simple operation with green button ƒƒ Simple operation with green button
class IE5 acc. IEC 60034-30-2) technology and display technology and display
ƒƒ Optional IF-module interfaces for ƒƒ Integrated dual pump management ƒƒ Integrated dual pump management
bus communication with building ƒƒ Integrated full motor protection with ƒƒ Integrated full motor protection with
automation trip electronics trip electronics
ƒƒ Motors with efficiency class IE4 ƒƒ Motors with efficiency class IE4
Technical data ƒƒ Fluid temperature -20 °C to +140 °C ƒƒ Fluid temperature -20 °C to +120 °C ƒƒ Fluid temperature -20 °C to +140 °C
ƒƒ Mains connection: 3~380 V -3~480 V ƒƒ Mains connection: 3~440 V ƒƒ Mains connection: 3~440 V
(±10 %), 50/60 Hz ±10 %, 50/60 Hz3~400 V ±10 %, ±10 %, 50/60 Hz3~400 V ±10 %,
ƒƒ Minimum efficiency index (MEI) ≥ 0.7 50/60 Hz3~380 V -5 %/+10 %, 50/60 Hz3~380 V -5 %/+10 %,
ƒƒ Nominal diameter DN 32 to DN 80 50/60 Hz 50/60 Hz
ƒƒ Max. operating pressure 16 bar ƒƒ Minimum efficiency index (MEI) ≥ 0.4 ƒƒ Minimum efficiency index (MEI) ≥ 0.4
ƒƒ Nominal diameter DN 32 to DN 80 ƒƒ Nominal diameter DN 40 to DN 80
ƒƒ Max. operating pressure 10 (16) bar ƒƒ Max. operating pressure 16 bar
Equipment/function ƒƒ Control modes: Δp-c, Δp-v, PID con- ƒƒ Control modes: Δp-c, Δp-v, PID con- ƒƒ Control modes: Δp-c, Δp-v, PID con-
trol, n=constant trol, n=constant trol, n=constant
ƒƒ Manual functions: E.g. differential ƒƒ Manual functions: E.g. differential ƒƒ Manual functions: E.g. differential
pressure setpoint setting, manual con- pressure setpoint setting, manual con- pressure setpoint setting, manual con-
trol mode, error acknowledgement trol mode, error acknowledgement trol mode, error acknowledgement
ƒƒ External control functions: E.g. ƒƒ External control functions: E.g. Over- ƒƒ External control functions: E.g. Over-
Overriding Off, External pump cycling, riding Off, external pump cycling (ef- riding Off, external pump cycling (ef-
analogue input 0-10 V/0-20 mA for fective only in double pump operation fective only in double pump operation
constant speed (DDC) mode), analogue input 0-10 V/ mode), analogue input 0-10 V/
ƒƒ Remote control via infrared interface 0-20 mA for constant speed (DDC) 0-20 mA for constant speed (DDC)
(IR-Stick/IR-Monitor), plug-in position ƒƒ Remote control via infrared interface ƒƒ Remote control via infrared interface
for IF-Modules for connection to (IR-Stick/IR-Monitor), plug-in position (IR-Stick/IR-Monitor), plug-in position
building automation for IF-Modules for connection to for IF-Modules for connection to
ƒƒ Safety functions building automation building automation
ƒƒ Safety functions ƒƒ Safety functions
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
16 Heating, air-conditioning, cooling
Series modification
Product range Glanded energy-saving pumps in mon- Glanded standard pumps in in-line Glanded standard pumps in in-line
obloc design design design
Field of application Heating, air conditioning, cooling, indus- Heating, air conditioning, cooling, indus- Heating, air conditioning, cooling, indus-
trial process trial process trial process
Application Pumping of heating water, cold water and Pumping of heating water, cold water and Pumping of heating water, cold water and
water-glycol mixtures without abrasive water-glycol mixtures without abrasive water-glycol mixtures without abrasive
substances in heating, cold water and substances in heating, cold water and substances in heating, cold water and
cooling systems cooling systems cooling systems
Special features ƒƒ Energy savings due to integrated ƒƒ High standard of corrosion protection ƒƒ Reduced life cycle costs thanks to
electronic control thanks to cataphoretic coating optimised efficiency
ƒƒ Optional interfaces for bus communi- ƒƒ Standard condensate drainage holes in ƒƒ Can be used flexibly in air-condition-
cation using plug-in IF-Modules the motor housings and lanterns ing and cooling systems, with applica-
ƒƒ Easy operation due to tried and tested ƒƒ Series design: motor with one-piece tion benefits due to direct draining of
green button technology and display shaft condensate
ƒƒ Integrated full motor protection with ƒƒ Version N: Standard motor B5 or V1 ƒƒ High standard of corrosion protection
trip electronics with stainless steel plug shaft ƒƒ Worldwide availability of standard mo-
ƒƒ Meets user requirements due to ƒƒ Bidirectional, force-flushed tors (according to Wilo specifications)
performance and main dimensions in mechanical seal and standard mechanical seals
accordance with EN 733 ƒƒ DPL: Main-/standby operation or ƒƒ Main/standby mode or peak-load op-
ƒƒ Motors with efficiency class IE4 peak-load operation (via additional eration (by means of external auxiliary
external device) device)
Technical data ƒƒ Fluid temperature -20 °C to +140 °C ƒƒ Fluid temperature -20 °C to +120 °C ƒƒ Fluid temperature -20 °C to +140 °C
ƒƒ Mains connection:3~440 V ƒƒ Mains connection 3~400 V, 50 Hz ƒƒ Mains connection 3~400 V, 50 Hz
±10 %, 50/60 Hz3~400 V ±10 %, ƒƒ Minimum efficiency index (MEI) ≥ 0.4 ƒƒ Minimum efficiency index (MEI) ≥ 0.4
50/60 Hz3~380 V -5 %/+10 %, 50/60 Hz ƒƒ Nominal diameter Rp 1 to DN 100 ƒƒ Nominal diameter DN 32 to DN 250
ƒƒ Minimum efficiency index (MEI) ≥ 0.4 ƒƒ Max. operating pressure 10 bar (special ƒƒ Max. operating pressure 16 bar (25 bar
ƒƒ Nominal diameter DN 32 to DN 125 version: 16 bar) on request)
ƒƒ Max. operating pressure 16 bar
Equipment/function ƒƒ Control modes: Δp-c, Δp-v, PID con- ƒƒ Single-stage, low-pressure centrifugal ƒƒ Single-stage, low-pressure centrifugal
trol, n=constant pump in in-line design with pump in in-line design with
ƒƒ Manual functions: E.g. differential ƒƒ Mechanical seal ƒƒ Mechanical seal
pressure setpoint setting, manual con- ƒƒ Flange connection with pressure ƒƒ Flange connection with pressure
trol mode, error acknowledgement measuring connection R ⅛ measuring connection R ⅛
ƒƒ External control functions: E.g. Over- ƒƒ Motor with one-piece shaft ƒƒ Lantern
riding Off, analogue input 0-10 V/0-20 ƒƒ DPL with switchover valve ƒƒ Coupling
mA for constant speed (DDC) ƒƒ Motors with efficiency class IE3 for ƒƒ IEC standard motor
ƒƒ Remote control via infrared interface motors ≥ 0.75 kW ƒƒ DL with switchover valve
(IR-Stick/IR-Monitor), plug-in position ƒƒ Motors with efficiency class IE3 for
for IF-Modules for connection to motors ≥ 0.75 kW
building automation
ƒƒ Safety functions
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
17
Product range Special glanded pumps in in-line design Glanded monobloc pumps Glanded monobloc pumps
Field of application Heating, air conditioning, cooling, indus- Heating, air conditioning, cooling, indus- Heating, air conditioning, cooling, indus-
trial process trial process trial process
Application IPH-W: For hot water in closed industrial Pumping of heating water, cold water and For pumping of cooling water, cold water,
circulation systems, district heating, water-glycol mixtures without abrasive water-glycol mixtures and other fluids
closed heating systems substances in heating, cold water and without abrasive substances
IPH-O: For heat transfer oil in closed cooling systems
industrial circulation systems
Special features ƒƒ Self-cooled mechanical seal, inde- ƒƒ Reduced life cycle costs through opti- ƒƒ Reduced life cycle costs through opti-
pendent of direction of rotation mised efficiency levels mised efficiency levels
ƒƒ Great variety of applications due to a ƒƒ High corrosion protection through ƒƒ Pump housing in plastic design
wide fluid temperature range without cataphoresis coating of the cast iron ƒƒ Version with Victaulic or threaded
additional wearing parts components connection (BAC 70/135... only with
ƒƒ Standard condensate drainage holes in Victaulic connection)
the motor housings
ƒƒ High worldwide availability of standard
motors (according to Wilo specifica-
tions) and mechanical seals
ƒƒ Performance and main dimensions in
accordance with EN 733
Technical data ƒƒ Fluid temperature IPH-W: -10 °C to ƒƒ Fluid temperature -20 °C to +140 °C ƒƒ Fluid temperature -15 °C to +60 °C
+210 °C (at max. 23 bar) ƒƒ Mains connection 3~400 V, 50 Hz ƒƒ Mains connection 3~400 V, 50 Hz
ƒƒ Fluid temperature IPH-O: -10 °C to ƒƒ Minimum efficiency index (MEI) ≥ 0.4 ƒƒ Minimum efficiency index (MEI) ≥ 0.4
+350 °C (at max. 9 bar) ƒƒ Nominal diameter DN 32 to DN 150 ƒƒ Nominal diameter G2/G 1½ (only
ƒƒ Mains connection 3~400 V, 50 Hz ƒƒ Max. operating pressure 16 bar (25 bar BAC 40…/S) or Victaulic connec-
ƒƒ Nominal diameter DN 20 to DN 80 on request) tion ∅ 60.3/48.3 mm (BAC 40… /R)
∅ 76.1/76.1 mm (BAC 70…/R)
ƒƒ Max. operating pressure 6.5 bar
Equipment/function ƒƒ Single-stage, low-pressure centrifugal ƒƒ Single-stage low-pressure centrifugal ƒƒ Single-stage low-pressure centrifugal
pump in in-line design with pump in monobloc design, with axial pump in monobloc design, with axial
ƒƒ Mechanical seal suction port and radially arranged suction port and radially arranged
ƒƒ Flange connection pressure port with pressure port
ƒƒ Lantern ƒƒ Mechanical seal ƒƒ Motors with efficiency class IE3
ƒƒ Motor with special shaft ƒƒ Flange connection with pressure
measuring connection R ⅛
ƒƒ Lantern
ƒƒ Coupling
ƒƒ Motors with efficiency class IE3 for
motors ≥ 0.75 kW
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
18 Heating, air-conditioning, cooling
Product range Standard glanded pumps Standard glanded pumps Axially split case pumps
Field of application Heating, air conditioning, cooling, water Heating, air conditioning, cooling, water Cooling, air conditioning, water distribu-
supply, industrial process supply, industrial process tion/boosting, industrial process
Application Pumping of heating water, cold water and Pumping of heating water, cold water and Pumping heating water, water-glycol
water-glycol mixtures without abrasive water-glycol mixtures without abrasive mixtures, cooling/cold water and process
substances. Applications in municipal substances. Applications in municipal water
water supply, irrigation, general industry, water supply, irrigation, general industry, Applications in municipal water supply,
power stations etc. power stations etc. irrigation, building services, general
industry, power stations, etc.
Volume flow Q max. 650 m3/h 2,800 m3/h 3,400 m3/h
Special features ƒƒ Reduced life-cycle costs through ƒƒ NLG: ƒƒ Higher capacities up to 17,000 m3/h
optimised efficiency levels --Reduced life cycle costs through on request
ƒƒ Bidirectional, force-flushed mechan- optimised efficiency ƒƒ Special motors and other materials on
ical seal --Mechanical seal independent of the request
ƒƒ Low NPSH values, best cavitation direction of rotation
properties --Interchangeable casing wear ring
ƒƒ Shaft coupling with or without spacer --Permanently lubricated, generously
coupling dimensioned roller bearings
ƒƒ NPG:
ƒƒ Suitable for temperatures up to 140 °C
ƒƒ Back pull-out version
Technical data ƒƒ Fluid temperature -20 °C to +120 °C ƒƒ Fluid temperature -20 °C to +120 °C ƒƒ Fluid temperature -8 °C to +120 °C
ƒƒ Mains connection 3~400 V, 50 Hz (depending on type) ƒƒ Mains connection 3~400 V, 50 Hz
ƒƒ Minimum efficiency index (MEI) ≥ 0.4 ƒƒ Mains connection 3~400 V, 50 Hz ƒƒ Nominal diameters - Suction side: DN
ƒƒ Nominal diameter: DN 50 to DN 500 ƒƒ Minimum efficiency index (MEI) ≥ 0.4 65 to DN 500
(suction side), DN 32 to DN 500 ƒƒ Nominal diameters: DN 150 to DN 500 ƒƒ Pressure side: DN 50 to DN 400
(pressure side) (depending on type) ƒƒ Max. operating pressure: 16 or 25 bar,
ƒƒ Operating pressure: depending on type ƒƒ Operating pressure: depending on depending on type
and application – up to 16 bar type and application – up to 16 bar
Equipment/function ƒƒ Single-stage horizontal spiral housing ƒƒ Single-stage horizontal spiral housing ƒƒ 1- or 2-stage, low-pressure centrifu-
pump with bearing bracket and pump with bearing bracket and gal pump in monobloc design
exchangeable casing wear rings in exchangeable casing wear rings (NLG ƒƒ Deliverable as complete unit or with-
process design only) in process design out motor or only pump hydraulics
ƒƒ Shaft sealing with mechanical seals in ƒƒ Shaft sealing with mechanical seals in ƒƒ Shaft sealing with mechanical seal or
accordance with EN 12756 or packing accordance with EN 12756 or packing stuffing box packing
stuffing box stuffing box ƒƒ 4-pole and 6-pole motors
ƒƒ Spiral housing with cast pump bases ƒƒ Spiral housing with cast pump bases ƒƒ Materials:
ƒƒ Shaft coupling with spacer coupling ƒƒ Greased grooved ball bearings for ƒƒ Pump housing: EN-GJL-250
ƒƒ Motors with efficiency class IE3 for bearing of pump shaft ƒƒ Impeller: G-CuSn5 ZnPb
motors ≥ 0.75 kW ƒƒ Motors with efficiency class IE3 ƒƒ Shaft: X12Cr13
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
19
Product range Glanded energy-saving pumps Condensate lifting units Particle separator systems for closed
Multi-pump systems HVAC loops
Duty chart H/m Wilo-SiFlux H/m Wilo-Plavis 011-C, 013-C, 015-C no illustration
50 50 Hz 5
40 4
SiFlux 21 SiFlux 31
30 3
20 2
10 1
0 0
0 50 100 150 200 250 300 350 400Q/m³/h 0 50 100 150 200 250 300 Q/l/h
Design Highly efficient, fully automatic, ready for Automatic condensate lifting unit Compact particle separator kit, consisting
connection multi-pump system for high of mechanical and hydraulic components.
volume flows in heating, cold water and Manual emptying of the system
cooling water systems. 3 to 4 electron-
ically controlled glanded in-line pumps
switched in parallel
Application For pumping heating water, water-gly- For pumping condensate out of Removes magnetic and non-magnetic
col mixtures and cooling and cold water Heat generators with condensing boiler particles from heating systems via nat-
without abrasive substances in heating, technology, Air-conditioning and cooling ural physical phenomena in commercial
cold water and cooling water systems systems (such as refrigerators, refrigerat- properties and for district heating
ed display cases and evaporators)
Special features ƒƒ Number of pumps: 2+1 or 3+1 (2 or 3 ƒƒ Low-noise operation (≤ 40 dB[A]) ƒƒ Removal of magnetic and non-mag-
pumps in operation, 1 standby pump ƒƒ Energy saving through low power netic particles from the medium,
each) consumption venting of micro bubbles
ƒƒ Quick and easy installation ƒƒ Easy installation thanks to adaptable ƒƒ High cleaning efficiency due to physi-
ƒƒ Energy-saving: Operation in partial inlet cal effects (gravity, filtration…)
load area according to current needs ƒƒ Quick and easy maintenance thanks to ƒƒ Easy to use due to ease of installation,
ƒƒ Reliable system thanks to optimally removable service cap and integrated maintenance, and simplified settings
matched components non-return valve ƒƒ Corrosion-resistant thanks to stainless
ƒƒ Compact design, good accessibility to steel particle separator
all components
Technical data ƒƒ Pump type: VeroLine-IP-E or Crono- ƒƒ Mains connection 1 ~ 100-240 V, ƒƒ Fluid temperature 0 °C to +95 °C
Line-IL-E 50/60 Hz ƒƒ Mains connection: 1~230 V, 50 Hz
ƒƒ 3~230/400 V, 50 Hz ±10 % ƒƒ Max. fluid temperature 60 °C
ƒƒ Fluid temperature: 0 °C to +120 °C ƒƒ Protection class IP X4
ƒƒ Pipe connections: DN 125 to DN 300 ƒƒ Inlet connections 18/40 mm
ƒƒ Flanges: PN 16, according EN 1092-2 ƒƒ Tank volume 0.7 l to 1.6
ƒƒ Max. permissible operating pressure:
10 bar (IP-E), 16 bar (IL-E)
Equipment/function ƒƒ Automatic pump control via Wilo-SCe ƒƒ Electric connecting cable with plug ƒƒ Anti-corrosive, hydraulic components
ƒƒ Parts that come in contact with the (1.5 m, versions available with UK plug) ƒƒ Fabric-reinforced hoses connected
fluid are corrosion-resistant ƒƒ 011-C and 013-C: Pressure hose (5 m, to inlet and outlet of the particle
ƒƒ Base frame made of galvanised steel, Ø 8) ; Alarm cable (1.5 m) ; Adjustable separator
with height-adjustable vibration rubber guide, Ø 2 to Ø 32; Detachable ƒƒ Pre-assembled venting unit for expul-
absorbers for insulation against struc- slide valve for maintenance sion of microbubbles
ture-borne noise ƒƒ 015-C: Granulated chamber wall for ƒƒ Movable magnetic rods for separation
ƒƒ Distributor steel, with corrosion- neutralisation of iron oxide particles
resistant coating ƒƒ Volume flow limiter
ƒƒ Shut-off valves, non-return valve, ƒƒ Manual purge valve for draining of
pressure gauge and premounted seals collected particles
ƒƒ Differential pressure sensor ƒƒ Switchbox for monitoring the circu-
lator
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
20 Heating, air-conditioning, cooling
NEW
Product range Particle separator systems for closed Control devices External Frequency Converter
HVAC loops (Comfort controller CC..., Vario control-
ler VR..., Smart controller SC...)
Field of application Heating, air conditioning, cooling Heating, air conditioning, cooling All water applications in Building Ser-
vices, Water Management and Industry,
especially: heating, air conditioning and
pressure boosting, etc.
Application SiClean Comfort removes particles from Switchgear for controlling 1 to 6 pumps Wall-mounted frequency converter for
heating systems using natural physical fixed-speed pumps equipped with asyn-
phenomena. For installation in commer- chronous or permanent magnet motors
cial properties and heating/air-condi-
tioning systems for district heating
Special features ƒƒ High efficiency via combination of ƒƒ Special versions on request ƒƒ Flexible and safe application
physical effects ƒƒ Compact design with energy-saving
ƒƒ Fully automated operation cooling concept to reduce tempera-
ƒƒ “Plug & Play” design ture losses
ƒƒ Fully automated and adjustable ƒƒ Integrated energy-efficient harmonic
disposal of collected particles in the reduction
desludging tank ƒƒ Additional energy-saving function in
ƒƒ Highly functional thanks to removal the partial load range of the pump
of all magnetic and non-magnetic ƒƒ Versatile use in pump applications
particles, free air and micro bubbles in thanks to several connection options
the fluid, support for the degasifica- and different control modes
tion process
Technical data ƒƒ Fluid temperature 0 °C to +95 °C – ƒƒ Max. ambient temperature: 55°C (50°C
ƒƒ Mains connection: 3~400 V, 50 Hz without derating) up to 90 kW, 50°C
(45°C without derating) from 110 kW
ƒƒ Environment protection class: IP55 up
to 90 kW, IP54 from 110 kW
Equipment/function ƒƒ Corrosion-resistant, hydraulic com- ƒƒ CC-HVAC: Control system for 1 to 6 ƒƒ IF-modules as an option: Profibus,
ponents pumps with fixed speed Ethernet, DeviceNet, Profinet, Modbus
ƒƒ Fabric-reinforced hoses connected ƒƒ CCe-HVAC: Control system for 1 to 6
to inlet and outlet of the particle pumps with integrated electronics/
separator speed control or external frequency
ƒƒ Pre-assembled flushing device includ- converter control
ing electronic drain valve and addition- ƒƒ VR-HVAC: Controller for 1 to 4 pumps
al safety valve with integrated speed control
ƒƒ Automatic draining of the particle ƒƒ SC-HVAC: Controller for 1 to 4 pumps
collection chamber ƒƒ SC and SC-FC versions for standard
ƒƒ SC switchgear pumps with fixed speed
ƒƒ Separator for removing magnetic and ƒƒ SCe version for infinitely variable, elec-
non-magnetic particles tronically controlled pumps or pumps
with integrated frequency converter
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
21
Field of application Heating, air conditioning, cooling Solar thermal and geothermal energy Geothermal energy systems
+P
Wilo-Yonos PICO-STG
12 7:8*7
28
10 24
8 20
6 16
12
4
8
2 4
15/1-13 15, 25, 30/1-7,5
0 0
0 1 2 3 4 Q/m³/h 0 1 2 3 4 5 4PåK
Design Glandless circulator with screwed con- Submersible pump, multistage
nection, EC motor and automatic power
adjustment
Application Wilo-Control products for connecting Circulation in solar thermal and geother- Water supply from boreholes, wells
pumps to building automation mal energy systems and rainwater storage for geothermal
applications
Special features – ƒƒ Green button for setting the control ƒƒ Performance-optimised motors for
mode Δp-v or the fixed speed geothermal applications
ƒƒ External speed control via integrated ƒƒ Parts in contact with the fluid are
interface PWM 1 (geothermal) and corrosion-resistant
PWM 2 (solar) ƒƒ Integrated non-return valve
ƒƒ Flexible connection cable with ƒƒ Low wear due to floating impellers
Wilo-Connector
ƒƒ Pump housing with cataphoretic
coating protects against corrosion due
to condensation formation
ƒƒ Operation and fault display via ring
LED
Technical data – ƒƒ Fluid temperature 0 °C to +110 °C ƒƒ Mains connection: 3~400 V, 50 Hz
ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Immersed operating mode: S1
ƒƒ Energy Efficiency Index (EEI) ≤ 0.23 ƒƒ Fluid temperature: 3-30 °C
ƒƒ Screwed connection Rp ½, Rp 1, Rp 1¼ ƒƒ Minimum flow rate at motor: 0.08 m/s
ƒƒ Max. operating pressure 10 bar ƒƒ Max. sand content: 50 g/m³
ƒƒ Up to 20 starts per hour
ƒƒ Max. immersion depth: 200 m
ƒƒ Minimum efficiency index MEI: ≥ 0.7
Equipment/function ƒƒ Wilo-IR-Stick/IR-Monitor ƒƒ Control modes: Δp-v, manual control ƒƒ Multistage submersible pump with
ƒƒ Remote control with infrared interface mode (n = constant), external speed radial or semi-axial impellers
for electronically controlled Wilo control with PWM 1 or PWM 2 signal ƒƒ Integrated non-return valve
pumps ƒƒ Interface for PWM 1 or PWM 2 signal ƒƒ NEMA coupling
ƒƒ Wilo-IF-Modules Stratos/IF-Modules ƒƒ Wilo-Connector ƒƒ Three-phase motor
ƒƒ Plug-in modules for BA connection ƒƒ Automatic deblocking function ƒƒ Hermetically sealed motors
of Stratos, Stratos GIGA/-D/-B, IP-E, ƒƒ Pump housing with cataphoretic
DP-E, IL-E/DL-E, BL-E, MHIE, MVIE, coating
Helix VE...
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
22 Heating, air-conditioning, cooling
Series extension
Product range Glandless high-efficiency pumps Glandless premium high-efficiency Glandless premium smart pumps
pumps
Field of application Domestic hot water Domestic hot water Domestic hot water
Duty chart H/m Wilo-Star-Z NOVA H/m Wilo-Stratos PICO-Z H/m Wilo-Stratos MAXO-Z
1,2 6 12
1,0 5 10
20, 25/1-6
0,8 4 8
0,6 3 6
0,4 2 4
20, 25/1-4
0,2 1 2
0 0 0
0 0,1 0,2 0,3 0,4 Q/m³/h 0 1 2 3 Q/m³/h 0 10 20 30 40 Q/m³/h
Design Glandless circulator with screwed Glandless circulator with screwed con- Smart glandless circulator with screwed
connection and blocking-current proof nection, EC motor and automatic power connection or flange connection, EC mo-
synchronous motor adjustment tor with integrated power adjustment
Application Domestic hot water circulation systems Domestic hot water circulation systems Domestic hot water circulation systems
in industry and in building services in industry and in building services and similar systems in industry and in
building services
Special features ƒƒ Hygienically safe thanks to proven ƒƒ Manual and temperature-controlled ƒƒ Intuitive operation by guided applica-
technology mode for optimum operation tion settings with the Setup Guide
ƒƒ Improved energy efficiency due ƒƒ Identification of the thermal disinfec- ƒƒ Maximum drinking water hygiene and
to synchronous motor with power tion of the drinking water tank energy efficiency by the new, innovative
consumption of only 3-6 watts and ƒƒ Display of the current consumption and intelligent control function T-const.
thermal insulation shell as standard in Watts and the cumulative kilowatt ƒƒ Optimum hygiene support thanks to
ƒƒ Quick, easy installation and re- hours or of the current flow and the thermal disinfection.
placement of common pump types temperature ƒƒ Bluetooth interface for connection to
thanks to flexible service motor and ƒƒ Stainless steel pump housing protects mobile devices.
Wilo-Connector against bacteria and corrosion ƒƒ Maximum electric installation comfort
ƒƒ Wilo-Connector by the optimised Wilo-Connector
ƒƒ Corrosion-resistant pump housing in
stainless steel
Technical data ƒƒ Fluid temperature: drinking water ƒƒ Fluid temperature: drinking water ƒƒ Fluid temperature: drinking water
up to water hardness 3.56 mmol/l up to water hardness 3.57 mmol/l max. +80 °C
(20 °dH): max. +65 °C (NOVA T: +95 °C) (20 °dH) max. +70 °C ƒƒ Heating water -10 °C to +110 °C
ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection 1~230 V, 50 Hz
ƒƒ Screwed connection Rp ½ ƒƒ Screw connection Rp ¾, Rp 1 ƒƒ Nominal diameter Rp 1 to DN 65
ƒƒ Max. operating pressure 10 bar ƒƒ Max. operating pressure 10 bar ƒƒ Max. operating pressure 10 bar
Equipment/function ƒƒ Wilo-Connector ƒƒ Control mode: Δp-c, tempera- ƒƒ Control mode: Dynamic Adapt plus,
ƒƒ Ball shut-off valve on suction side ture-controlled mode ∆p-c, ∆p-v, n-const, T-const,
and non-return valve on pressure side ƒƒ Temperature control for constant ∆T-const and Q-const
(Star-Z NOVA A, C, T) return temperature in drinking water ƒƒ Multi-Flow Adaptation
ƒƒ Including plug-in time switch, 1.8 m circulation systems ƒƒ Remote control via Bluetooth interface
connection cable (Star-Z NOVA C) ƒƒ Thermal disinfection routine ƒƒ Selection of application range with
ƒƒ Star-Z NOVA T incl. timer, thermo- ƒƒ Reset function for resetting the elec- Setup Guide
static valve and detection of thermal tricity counter or to factory settings ƒƒ Heat meatering
desinfection, LC display with symbolic ƒƒ “Hold” function (key lock) ƒƒ Desinfection detection
language ƒƒ Wilo-Connector ƒƒ Air-venting function
ƒƒ Automatic deblocking function ƒƒ Retrofitable interface modules for
communication
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
23
Product range Glandless high-efficiency pumps Glandless standard high-efficiency Standard glandless pumps
pumps
Field of application Domestic hot water Domestic hot water Domestic hot water
Application Domestic hot water circulation systems Domestic hot water circulation systems Domestic hot water circulation systems
and similar systems in industry and in in industry and in building services in industry and in building services
building services
Special features ƒƒ Energy savings through greater system ƒƒ LED display for indication of set deliv- ƒƒ All plastic parts that come into contact
efficiency with the Q-Limit function ery head and fault codes with the fluid fulfil KTW recommen-
ƒƒ Space-saving installation due to com- ƒƒ Quick setting when replacing an un- dations
pact design and location-dependent controlled standard pump with pre-set
LC display speed stages, e.g. TOP-Z
ƒƒ Retrofitable interface modules for ƒƒ Electrical connection with Wilo plug
communication (e.g. Modbus, BACnet, ƒƒ Collective fault signal ensures system
CAN, LON and PLR) availability
ƒƒ Corrosion-resistant pump housing in ƒƒ Corrosion-resistant pump housing in
red brass for systems where oxygen red brass for systems where oxygen
entry is possible entry is possible
ƒƒ Tried and tested quality and reliability
Technical data ƒƒ Fluid temperature: drinking water ƒƒ Permissible temperature range drink- ƒƒ Fluid temperature: drinking water up
max. +80 °C ing water up to a water hardness of to water hardness 3.2 mmol/l (18 °dH)
ƒƒ Heating water -10 °C to +110 °C 3.57 mmol/l (20 °dH) max. +80 °C max. +65 °C
ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection 1~230 V, 50 Hz
ƒƒ Energy Efficiency Index (EEI) ≤ 0.20 ƒƒ Nominal diameter Rp 1 to DN 50 (DM = 3~400 V, 50 Hz)
(EEI ≤ 0.23 for double pumps) ƒƒ Max. operating pressure 10 bar ƒƒ Screwed connection Rp ½, Rp 1
ƒƒ Nominal diameter Rp 1 to DN 65 ƒƒ Max. operating pressure 10 bar
ƒƒ Max. operating pressure 10 bar
Equipment/function ƒƒ Control modes: ∆p-c, ∆p-v, ∆p-T ƒƒ Control modes: Δp-c, Δp-v, 3 speed ƒƒ Constant speed or 3 selectable speed
ƒƒ Volume flow limitation with Q-Limit stages stages (Star-Z 25/6),
function (via IR-Stick) ƒƒ LED display for setting the required ƒƒ Quick electrical connection with spring
ƒƒ Pre-selectable speed for constant delivery head clips
operation ƒƒ Quick electrical connection with Wilo ƒƒ Star-ZD version as double pump
ƒƒ Automatic setback operation plug
ƒƒ Graphical pump display ƒƒ Motor protection, fault signal light and
ƒƒ Remote control via infrared interface contact for collective fault signal
(IR-Stick/IR-Monitor) ƒƒ Corrosion-resistant pump housing in
ƒƒ Retrofitable interface modules for red brass
communication ƒƒ Combination flanges PN 6/PN 10 (for
ƒƒ Combination flanges PN 6/PN 10 (for DN 40 to DN 65)
DN 40 and DN 65)
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
24 Heating, air-conditioning, cooling
Application Domestic hot water circulation systems For pumping drinking water, cold and
in industry and in building services hot water without abrasive substances,
in heating, cold water and cooling water
systems
Special features ƒƒ Thermal winding contact (WSK) as ƒƒ High resistance to corrosive fluids due
potential-free contact (depending on to stainless steel housing and Noryl
type) impeller
ƒƒ Rotation control lamp indicates the ƒƒ Wide range of applications due to
correct direction of rotation (only for suitability for water hardness up to
3~) 5 mmol/l (28 °dH)
ƒƒ Thermal insulation as standard ƒƒ All plastic parts that come into contact
with the fluid fulfil KTW recommen-
dations
Technical data ƒƒ Fluid temperature: drinking water ƒƒ Fluid temperature: drinking water up
max. +80 °C (+65°C for TOP-Z 20/4 to a water hardness of 4.99 mmol/l
and TOP-Z 25/6) (28 °dH) max. +65 °C
ƒƒ Mains connection: ƒƒ Heating water -8 °C to +110 °C
ƒƒ 1~230 V, 50 Hz (depending on type) ƒƒ Mains connection 1~230 V, 50 Hz,
ƒƒ 3~400 V, 50 Hz 3~400 V, 50 Hz
ƒƒ Nominal diameter Rp 1 to DN 65 ƒƒ Nominal diameter Rp 1
ƒƒ Max. operating pressure 10 bar ƒƒ Max. operating pressure 10 bar
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
25
Outside the EU
Pumps of the following series are allowed to be further distri-
buted outside the EU, however in compliance with the legislation
in force in these countries.
Star-RS/RSD
TOP-S/SD
TOP-RL
Star-STG
Note
An energy efficiency evaluation and a CE conformity declaration
(CE mark) do no longer exist for these products.
*Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary,
Ireland, Italy, Latvia, Lithuania, Luxemburg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Great Britain
+ Croatia (EU member from 2013 on), + Turkey (candidate country), + Serbia (candidate country)
+ 4 countries of the EFTA (European Free Trade Association) Iceland, Norway, Liechtenstein, Switzerland
26 Heating, air-conditioning, cooling
Product range Standard glandless pumps Standard glandless pumps Standard glandless pumps
Field of application Heating, air conditioning, cooling Heating, air conditioning, cooling Heating, air conditioning, cooling
Application Hot-water heating systems of all kinds, Hot-water heating systems of all kinds, Hot-water heating systems of all kinds,
industrial circulation systems, cold water industrial circulation systems, cold water industrial circulation systems, cold water
and air-conditioning systems and air-conditioning systems and air-conditioning systems
Special features ƒƒ Suitable for any installation position ƒƒ Rotation control lamp indicates the ƒƒ Collective fault signal as potential-free
with horizontal shaft; terminal box in correct direction of rotation (only for contact (depending on type)
3-6-9-12 o’clock position 3~) ƒƒ Pump housing with cataphoretic (KTL)
ƒƒ Three pre-selectable speed stages for ƒƒ Manual power adjustment with 3 coating protects against corrosion due
load adaptation speed stages to condensation formation
ƒƒ Easy and safe installation with prac- ƒƒ Pump housing with cataphoretic (KTL)
tical wrench attachment point on the coating protects against corrosion due
pump housing to condensation formation
ƒƒ Simplified electrical connection thanks
to a terminal box where the threaded
cable connection can be taken out and
used from both sides; quick connec-
tion with spring clips
Technical data ƒƒ Fluid temperature -10 °C to +110 °C ƒƒ Fluid temperature -20 °C to +130 °C ƒƒ Fluid temperature -20 °C to +130 °C
ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection: ƒƒ Mains connection 1~230 V, 50 Hz,
ƒƒ Screw connection Rp ½, Rp 1, Rp 1½ ƒƒ 1~230 V, 50 Hz (depending on type) 3~400 V, 50 Hz
ƒƒ Max. operating pressure 10 bar ƒƒ 3~400 V, 50 Hz ƒƒ Nominal diameter Rp 1 to DN 40
ƒƒ Nominal diameter Rp 1 to DN 100 ƒƒ Max operating pressure 10 bar (op-
ƒƒ Max operating pressure 10 bar (op- tional: 16 bar)
tional: 16 bar)
Equipment/function ƒƒ 3 manually selectable speed stages ƒƒ Preselectable speed stages for perfor- ƒƒ Preselectable speed stages for perfor-
ƒƒ Wrench attachment point on pump mance adaptation mance adaptation
body ƒƒ Combination flanges PN 6/PN 10 (DN ƒƒ Pump housing is KTL-coated
ƒƒ Cable inlet possible from both sides - 40 to DN 65) ƒƒ Combination flange PN 6/PN 10 (DN
for easy installation ƒƒ Pump housing is KTL-coated 40)
ƒƒ Quick electrical connection with spring ƒƒ Thermal insulation shells for heating
clips applications as standard
ƒƒ RSD version as double pump ƒƒ Extendable motor protection
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
27
Series Wilo-Star-STG
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
28 Water supply
INTELLIGENT TECHNOLOGIES
TO COMBAT
WATER SHORTAGES.
PUMPS AND SYSTEMS FOR RAINWATER UTILISATION, WATER
SUPPLY AND PRESSURE BOOSTING, FIREFIGHTING, WATER
PURIFICATION, RAW WATER INTAKE, DESALINATION AND
PROFESSIONAL IRRIGATION/AGRICULTURE.
29
Water is one of the most precious resources on the planet. With a growing world population, more and more water is
required for drinking, cleaning and hygiene, in agriculture and industry. Insufficient access to water is an urgent problem
worldwide – and a major source of potential conflict. The extraction and supply of water are therefore among the most
important challenges of the future. Wilo develops pumps and systems that enable the use and optimisation of new
sources and methods of water collection. Our flexible solutions ensure a reliable supply while adapting to the require-
ments of buildings that range from multi-family houses, schools to industrial parks. With individual concepts and highly
efficient technologies, we advance the construction of intelligent networks as well as the availability of decentralised
water purification systems.
Water supply
an enormous challenge. Jordan, for example, is one of the
most arid countries in the world. Fresh water is pumped
into the major cities from the Jordan Valley over a vertical
distance of 1,400 metres. The growing population and old,
leaky pipe systems further aggravate the problem. Wilo
provided new equipment and above all expertise for the
drinking water pumping station in Ebquoreyeh. Equipped
with two efficient Wilo-EMU K pressure shroud pumps,
energy saving systems and new monitoring, the pumping
station now reliably supplies drinking water to 50,000 in-
habitants. And it saves more than 1.5 million kilowatt
hours, 1,100 tonnes of CO2 and over 110,000 euros in
electricity costs per year.
Product range Rainwater utilisation systems Rainwater utilisation systems Rainwater utilisation systems
Duty chart H/m Wilo-RainSystem H/m Wilo-RainSystem AF 150 H/m Wilo-RainSystem AF 400
AF Basic 50 50
50 AF Comfort
40 40
40
30 30
30
20 20
20 10 10
10 0 0
0 1 2 3 4 Q/m³/h 0 2 4 6 8 10 12 14 Q/m³/h 0 2 4 6 8 10 12 14 Q/m³/h
Design Ready-to-plug rainwater utilisation sys- Automatic rainwater utilisation system Automatic rainwater utilisation system
tem with 1 MultiCargo MC self-priming with 2 MultiCargo MC self-priming cen- with run-down tank and 2 MultiPress MP
centrifugal pump trifugal pumps non self-priming centrifugal pumps
Application Rainwater utilisation for saving drinking Rainwater utilisation in multi-family Hybrid system for commercial and indus-
water in conjunction with rainwater houses and small businesses for saving trial rainwater utilisation for saving drink-
storage tanks or reservoirs drinking water in conjunction with rain- ing water in conjunction with rainwater
water storage tanks or reservoirs storage tanks or reservoirs
Special features ƒƒ Low-noise, due to encapsulated sys- ƒƒ Low-noise due to multistage pumps ƒƒ Low-noise due to flow-and noise-op-
tem (Comfort) and multistage pump ƒƒ Media-touched components are timised overall concept with multi-
ƒƒ System fulfills DIN 1989 and EN 1717 corrosion-free stage pumps
ƒƒ Demand-oriented, flow- and ƒƒ Maximum operational reliability due to ƒƒ Media-touched components are
noise-optimised fresh water replen- fully electronic controller (RCP) corrosion-free
ishment ƒƒ Demand-oriented fresh water replen- ƒƒ Maximum operational reliability due to
ƒƒ Media-touched components are ishment a fully electronic controller (RCH)
corrosion-free ƒƒ High reliability due to flow-optimised ƒƒ Demand-oriented fresh water replen-
ƒƒ Automatic support function for evacu- and noise-optimised replenishment ishment
ation of air (Comfort) reservoir ƒƒ Automatic control of the feeding
pump
ƒƒ System/level control in the low-volt-
age range
Technical data ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection 3~400 V, 50 Hz
ƒƒ Suction head max. 8 m ƒƒ Suction head max. 8 m ƒƒ Fluid temperature max. +5 °C to
ƒƒ Fluid temperature max. +5 °C to ƒƒ Fluid temperature max. +5 °C to +35 °C
+35 °C +35 °C ƒƒ Max. operating pressure 10 bar
ƒƒ Max. operating pressure 8 bar ƒƒ Max. operating pressure 8 bar ƒƒ Replenishment reservoir 400 l
ƒƒ Replenishment reservoir 11 l with float ƒƒ Replenishment reservoir 150 l with ƒƒ Protection class IP 54
valve float valve
ƒƒ Protection class IP 42/IP 54 ƒƒ Protection class IP 41
Equipment/function ƒƒ Connection-ready module mounted ƒƒ Connection-ready module on vibra- ƒƒ Connection-ready module on vibra-
on a non-corroding base frame tion-insulated tubular frame tion-insulated baseplate
ƒƒ Pressure-side pipework Rp 1 ƒƒ Pressure sided joint tubing R 1 ½ with ƒƒ Pressure sided joint tubing R 1½ with
ƒƒ 1.8/3.0 m connection cable and mains transmitter unit, diaphragm pressure transmitter unit, diaphragm pressure
plug vessel, shut-off device vessel, shut-off device
ƒƒ Switchgear Rain Control Basic RCB/ ƒƒ Pressure gauge 0-10 bar ƒƒ Pressure gauge 0-10 bar
Economy RCE with control electronics ƒƒ Ball valve on suction/pressure sides ƒƒ Ball valve on suction/pressure sides,
ƒƒ Monitoring of rainwater storage levels ƒƒ Central switchgear (RCP) with control non-return valve
ƒƒ Connection for overflow warning electronics, level sensor ƒƒ Hybrid tank with all connections,
ƒƒ Menu-prompted operation and display calmed inlets and overflow with siphon
ƒƒ Pump cycling and test run ƒƒ Central switchgear (RCH) with control
ƒƒ Automatic fault-actuated switchover, electronics
peak-load operation plus water ex- ƒƒ Pump cycling and test run
change in the replenishment reservoir ƒƒ Automatic fault-actuated switchover,
peak-load operation plus water ex-
change in the replenishment reservoir
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
31
Product range Self priming pumps, self-priming multi- Self- and non self-priming multistage Non self-priming peripheral pump
stage pumps and pump systems pumps and pump systems
Field of application Rainwater utilisation, water supply/pres- Rainwater utilisation, water supply/pres- Water supply/ pressure boosting, raw
sure boosting, raw water intake sure boosting, raw water intake water intake, rainwater utilisation
Duty chart H/m Wilo-Jet H/m Wilo-HiMulti 3 /..C /..H H/m Wilo-HiPeri
WJ / HWJ / FWJ 50 50
40
40 40
30
30 30
20
20 20
10 HiPeri 1-5
10 10
0 0 HiPeri 1-4
0
0 1 2 3 4 5 Q/m³/h 0 1 2 3 4 5 6 Q/m³/h 0 5 10 15 20 25 30 35 Q/l/min
Design Self-priming single-stage centrifugal Self-priming (version P) and non Non self-priming peripheral pump
pumps self-priming multistage pumps and pump
systems
Water supply
Application For pumping water from wells for filling, For domestic potable water supply, sprin- For water supply/pressure boosting, raw
pumping empty, transferring by pumping, kling, irrigation, spraying and rainwater water intake, sprinkling and spraying,
irrigation and sprinkling utilisation rainwater utilisation
As emergency pump for overflows
Special features ƒƒ Ideal for portable outdoor applications ƒƒ Easy: Electrical quick connector, On/ ƒƒ Simple handling thanks to low weight,
(hobby, garden) Off switch, cap for filling and draining, perfectly suited for permanent oper-
ƒƒ HWJ version with diaphragm pressure enlarged foot fastening ation
vessel and pressure switch ƒƒ Efficient and economical: highly effi- ƒƒ Brass impeller for fluids up to 60 °C and
ƒƒ FWJ version with fluid control for cient hydraulics, extremely compact ambient temperatures up to 40 °C
system control ƒƒ HiMulti 3 C (P): Automation and ƒƒ Efficient thanks to low power con-
ƒƒ FWJ SmartHome version with addi- dry-running protection, automation sumption at a high maximum delivery
tional adapter plug which enables rotatable by 360° for easier installation head and high maximum volume flow
the integration of the pump into a ƒƒ HiMulti 3 H (P): Automation and water ƒƒ Expandable with the electronic pump
Smart Home system. A wibutler app hammer protection control Wilo-Fluidcontrol/HiControl 1
allows controlling pump operation via
a smartphone and customising it (e.g.
combination with a moisture sensor)
Technical data ƒƒ Mains connection 1~230 V, 50 Hz / ƒƒ Mains connection 1~230 V, 50 Hz ƒƒ Mains connection 1~230 V, 50 Hz
3~400 V, 50 Hz ƒƒ Inlet pressure max. 3 bar ƒƒ Inlet pressure max. 1.5 bar
ƒƒ Inlet pressure max. 1 bar ƒƒ Fluid temperature max. 0 °C to ƒƒ Fluid temperature max. +5 °C to
ƒƒ Fluid temperature max. +5 °C to ƒƒ +40 °C (+55 °C for max. 10 minutes) +60 °C
+35 °C ƒƒ Operating pressure max. 8 bar ƒƒ Max. operating pressure 6.5 bar
ƒƒ Max. operating pressure 6 bar ƒƒ Protection class IP X4, IP 54 ƒƒ Protection class IP x4
ƒƒ Protection class IP 44 ƒƒ Suction/pressure side connections:
Rp 1"
Equipment/function ƒƒ With or without carrying frame, de- ƒƒ Directly flanged motor ƒƒ Single-stage displacement pump with
pending on the version (WJ, FWJ) ƒƒ Thermal motor protection switch for a radial impeller
ƒƒ For single-phase AC motor (1~230 V) 1~230 V version ƒƒ Can be supplemented by the
ƒƒ Connection cable with plug ƒƒ Version HiMulti 3 C (P): Automatic Wilo-FluidControl resp. HiControl 1
ƒƒ On/Off switch pump control, low-water level switch
ƒƒ Thermal motor protection switch ƒƒ Version HiMulti 3 H (P): Pressure
switch, diaphragm pressure vessel
50 l/100 l
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
32 Water supply
Product range Non self-priming water-supply unit Cistern pumps Non self-priming water-supply unit
with frequency converter
Field of application Rainwater utilisation, water supply/pres- Rainwater utilisation, water supply/pres- Water supply/pressure boosting
sure boosting, raw water intake sure boosting, raw water intake
Duty chart H/m Wilo-EMHIL H/m Wilo-Sub TWI 5 H/m Wilo-COE 2 TWI 5
50 60
80
50
40
60 40
30
40 30
20 20
10 20
10
0 0 0
0 1 2 3 4 5 6 7 Q/m³/h 0 2 4 6 8 10 12 14 Q/m³/h 0 4 8 12 16 Q/m³/h
Design Non self-priming water-supply unit with Submersible pumps Pressure boosting system with two paral-
frequency converter lel submersible pumps
Application Water supply For domestic water supply from wells, Pressure boosting and water supply in
Rainwater utilisation rainwater storage tanks, and reservoirs. residential applications and for small
Irrigation and spraying For irrigation, sprinkling, rainwater utili- commercial installations that require
sation or for pumping out water compact construction and a low noise
level
Special features ƒƒ Heavy-duty multistage pump with ƒƒ Ready-to-plug in EM version ƒƒ Pumps in the TWI 5 series with low
stainless steel hydraulics (1~230 V) noise due to water-cooled motor,
ƒƒ Easy operation and adjustment: ƒƒ Pump (housing, stages, impellers) between 51 dB (A) and 61 dB (A)
ƒƒ Large display screen made entirely of stainless steel 1.4301 ƒƒ 2-pump pressure boosting system in
ƒƒ LEDs for status display (AISI 304) compact design due to vertical pump
ƒƒ Plug & Pump ƒƒ Self-cooling motor enables installation layout
ƒƒ Functions: PID, frost protection, restart outside water ƒƒ Economical system, based on the basic
after a fault functions of the BC switchgear
ƒƒ Float switch can be connected as an ƒƒ Long service life due to the stainless
option steel construction of the pumps and
the piping
Technical data ƒƒ Max. operating pressure: 10 bar ƒƒ Mains 3~400 V or 1~230 V ±10% ƒƒ Mains 3~400 V or 1~230 V ±10%
ƒƒ Max. fluid temperature: 40 °C 50 Hz 50 Hz
ƒƒ Min. fluid temperature: 0 °C ƒƒ Fluid temperature max. +40 °C ƒƒ Fluid temperature max: +40°C
ƒƒ Max. ambient temperature: 50 °C ƒƒ Max. operating pressure 10 bar ƒƒ Operating pressure max: 10 bar
ƒƒ Mains connection: 1~230 V, 50/60 Hz ƒƒ Protection class IP 68 ƒƒ Nominal connection diameters G 2"
ƒƒ Pressure-side Rp 1¼
ƒƒ Suction-side (SE version) Rp 1¼
Equipment/function ƒƒ Including 1.4 m mains connection and ƒƒ Connection cable, 20 m ƒƒ Intake and outflow collector pipes
plug ƒƒ TWI 5 version with standard intake ƒƒ Ball shut-off valves on the suction side
ƒƒ Including EMC filter strainer and pressure side
ƒƒ With built-in pressure and flow con- ƒƒ Variants: ƒƒ Non-return valve on the pressure side
trollers ƒƒ SE: with lateral inlet connecting piece ƒƒ 1 manometer
ƒƒ FS: with built-in float switch ƒƒ 2 pressure switches
ƒƒ Thermal motor protection for EM ƒƒ BC switchgear
version (1~230 V)
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
33
IE
Product range Vertical, multistage centrifugal pumps Vertical, multistage centrifugal pumps Vertical, multistage centrifugal pumps
Field of application Water supply/pressure boosting Water supply/pressure boosting Water supply/pressure boosting, profes-
sional irrigation/agriculture
Water supply
Application Water supply and pressure boosting Water supply and pressure boosting Water supply and pressure boosting
Industrial circulation systems Industrial circulation systems Industrial circulation systems
Process water Process water Process water
Closed cooling circuits Closed cooling circuits Closed cooling circuits
Washing systems, Irrigation Washing systems, Irrigation Washing systems, Irrigation
Special features ƒƒ High-efficiency EC motor (energy ƒƒ Multistage, speed-configurable stain- ƒƒ Efficiency-optimised, laser-welded
efficiency class IE5 acc. to IEC 60034- less steel high-efficiency pump with 2D/3D hydraulics, flow and degassing
30-2) 2D/3D hydraulics optimised
ƒƒ Integrated electronic control “High ƒƒ Optimised design for easy operation, ƒƒ Corrosion-resistant impellers, guide
Efficiency Drive” transportation and installation with vanes and stage housings
ƒƒ Easy operation thanks to proven Green handles, lantern adjustment and rotat- ƒƒ Maintenance-friendly design with
Button Technology and clear display able free flanges particularly robust coupling guard
ƒƒ User-friendly cartridge mechanical ƒƒ User-friendly display with Green But- ƒƒ Drinking water approval
seal “X-Seal” and spacer coupling ton Technology and full text menu
(from 5.5 kW) ƒƒ IF plug-in module for quick communi-
ƒƒ Flexible connection to building auto- cation with the BMS
mation ƒƒ Drinking water approval
ƒƒ Drinking water approval
Technical data ƒƒ Fluid temperature: -30 to +120 °C ƒƒ Fluid temperature -30 to +120 °C with ƒƒ Fluid temperature -30 to +120 °C with
with EPDM (-10 to +90 °C with FKM) EPDM (-10 to +90 °C with FKM) EPDM (-10 to +90 °C with FKM)
ƒƒ Max. operating pressure: 16/25 bar ƒƒ Max. operating pressure 16/25 bar ƒƒ Max. operating pressure 16/25/30 bar
ƒƒ Protection class IP 55 ƒƒ Max. inlet pressure 10 bar ƒƒ Max. inlet pressure 10 bar
ƒƒ Minimum efficiency index MEI ≥ 0.7 ƒƒ Protection class IP 55 ƒƒ Protection class IP 55
(Helix EXCEL 16: MEI ≥ 0.5) ƒƒ Minimum efficiency index MEI ≥ 0.7 ƒƒ Minimum efficiency index MEI ≥ 0.7
(Helix VE 16: MEI ≥ 0.5) (Helix V 16: MEI ≥ 0.5)
Equipment/function ƒƒ Impellers, stage chambers and pump ƒƒ Impellers, stage chambers and pump ƒƒ Impellers, stage chambers and pump
housing made of stainless steel housing made of stainless steel housing made of stainless steel
1.4301/1.4404 (AISI 304L/AISI 316L) 1.4301/1.4404 (AISI 304L/AISI 316L) 1.4301/1.4404 (AISI 304L/AISI 316L)
ƒƒ Helix EXCEL 2 - 16, PN 16 with oval ƒƒ Helix VE 2 - 16, PN 16 with oval flang- ƒƒ Helix V 2 - 16, PN 16 with oval flanges,
flanges, PN25 with round flanges es, PN25 with round flanges PN25 with round flanges
ƒƒ Helix EXCEL 22 - 36, with round ƒƒ Helix VE 22 - 36, with round flanges ƒƒ Helix V 22 - 36, with round flanges
flanges ƒƒ IEC standard motor ƒƒ IEC standard motor
ƒƒ EC IE5 Motor ƒƒ Integrated frequency converter
ƒƒ Integrated electronic control
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
34 Water supply
Product range Vertical, multistage centrifugal pumps Vertical and horizontal, multistage Vertical, multistage centrifugal pumps
centrifugal pumps
Field of application Water supply/pressure boosting, profes- Rainwater utilisation, water supply/pres- Water supply/pressure boosting, profes-
sional irrigation/agriculture sure boosting, raw water intake sional irrigation/agriculture
Duty chart H/m Wilo-Helix FIRST V H/m Wilo-Zeox FIRST H/m Wilo-Multivert MVIE
280 100
400
240
Zeox FIRST H 80
200 300
160 60
120 200
Zeox FIRST V 40
80
100 20
40
0 0 0
0 10 20 30 40 50 60 70 Q/m³/h 0 50 100 150 200 250 Q/m³/h 0 20 40 60 80 100 120 140 Q/m³/h
Design Non self-priming multistage pump Non-self-priming, high-efficiency multi- Non self-priming multistage pump with
stage high-pressure centrifugal pump in integrated frequency converter
vertical or horizontal design with off-line
connections
Application Water distribution and pressure boosting Professional irrigation/agriculture Water supply and pressure boosting
Industrial circulation systems Water supply/pressure boosting Industrial circulation systems
Process water Fire fightingHeating Process water
Closed cooling circuits air-conditioning, cooling Closed cooling circuits
Washing systems, Irrigation Washing systems, Irrigation
Technical data ƒƒ Fluid temperature range: -20 to 120 °C ƒƒ Fluid temperature: -5 °C to +90 °C ƒƒ Fluid temperature -15 to +120 °C
ƒƒ Max. operating pressure: 16/25/30 bar ƒƒ Max. suction pressure: Zeox FIRST .. V/ ƒƒ Max. operating pressure 16 bar/25 bar
ƒƒ Protection class: IP 55 .. H: 6/16 bar Max. operating pressure: ƒƒ Max. inlet pressure 10 bar
ƒƒ Minimum efficiency index MEI ≥ 0.7 Zeox FIRST V: 27 bar Zeox FIRST H (DN ƒƒ Protection class IP 55
(Helix FIRST V 16: MEI ≥ 0.5) 65 to DN 1 00): 50 bar; Zeox FIRST H ƒƒ Minimum efficiency index MEI ≥ 0.4
(DN 150): 40 bar
ƒƒ Protection class: IP 55
Equipment/function ƒƒ Corrosion-resistant impellers, guide ƒƒ IE3 high-efficiency motor as standard ƒƒ Stainless steel hydraulics with pump
vanes and stage housings ƒƒ Flushing by-pass device to ensure a housing made of cast iron
ƒƒ Helix FIRST V 2 - 16, PN 16 with oval long service life ƒƒ MVIE 70.. to 95.. PN 16/25 with round
flanges, PN25 with round flanges ƒƒ Packing gland on request, exchangea- flange
ƒƒ Helix FIRST V 22 - 36, with round ble without disassembling the pump ƒƒ IEC standard motor
flanges ƒƒ Integrated frequency converter with
ƒƒ IEC standard motor Green Button Technology and LCD
display for status indication
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
35
Product range Vertical, multistage centrifugal pumps Sectional pumps Vertical, multistage centrifugal pumps
Series Wilo-Multivert MVI Series RN, HS, IPB, PJ, STD PLURO, FG/FH Wilo-Multivert MVISE
Field of application Water supply/pressure boosting, profes- Industrial process Water supply/pressure boosting
sional irrigation/agriculture
Water supply
Application Water supply and pressure boosting Metal industry, mine dewatering, desali- Water supply and pressure boosting
Industrial circulation systems nation plants, boiler supply, fire fighting,
Process water high-pressure cleaning, water supply
Closed cooling circuits
Washing systems, Irrigation
Special features ƒƒ MVI 70..-95.. in stainless steel with ƒƒ Modular design ensures pump versions ƒƒ Glandless pump technology
pump housing made of cataphoret- in a variety of materials and versions ƒƒ Virtually noiseless operation (up to
ic-coated cast iron which can be adapted to meet cus- 20 dB [A] quieter than conventional
tomer demands precisely pumps)
ƒƒ Hydraulic pressure compensation ƒƒ Space-saving, compact design
relieves load on bearings and ensures a ƒƒ Virtually maintenance free thanks to
longer service life a design which does not feature any
ƒƒ Multiple optional pressure connec- mechanical seals
tions allow different pressures to be ƒƒ Drinking water approval for all com-
supplied from a single pump ponents that come in contact with the
fluid (EPDM version)
Technical data ƒƒ Fluid temperature -15 to +120 °C ƒƒ Permitted temperature range up to ƒƒ Fluid temperature -15 to +50 °C
ƒƒ Max. operating pressure 16/25 bar +80 °C, or up to +160 °C on request ƒƒ Max. operating pressure 16 bar
ƒƒ Max. inlet pressure 10 bar ƒƒ Max. operating pressure 180 bar ƒƒ Max. inlet pressure 16 bar
ƒƒ Protection class IP 55 ƒƒ Nominal diameter on pressure side ƒƒ Protection class IP 44
ƒƒ Minimum efficiency index MEI ≥ 0.4 DN 32 to DN 250
ƒƒ 2- or 4-pole 50 Hz motors, 60 Hz on
request
Equipment/function ƒƒ MVI 70.. to 95.. PN 16/PN 25 with ƒƒ 2 to 15-stage industrial version ƒƒ Multistage, non-self-priming, vertical
round flange ƒƒ Screwed segments high-pressure centrifugal pump in
ƒƒ IEC standard motor, 2-pole ƒƒ Hydraulic axial compensation in-line design
ƒƒ Shaft sealing with mechanical seal or ƒƒ Glandless three-phase motor with
stuffing box packing integral water-cooled frequency
ƒƒ Optionally with multiple pressure converter
outlets for e.g. fire extinguishing ƒƒ Hydraulic connection with oval flanges
applications PN 16. Counter flanges made of stain-
ƒƒ Supplied as a complete unit: with less steel with female thread, screws
pump, coupling, motor mounted on and gaskets (scope of delivery)
baseplate or without motor or as pump
only, with free shaft end
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
36 Water supply
Product range Vertical, multistage centrifugal pumps Horizontal, multistage centrifugal Horizontal, multistage centrifugal
pumps pumps
Field of application Water supply/pressure boosting Water supply/pressure boosting Water supply/pressure boosting
Duty chart H/m Wilo-Multivert MVIS H/m Wilo-Economy MHIE H/m Wilo-Economy MHI
100 70
80
60
80 50
60
60 40
40 30
40
20
20 20
10
0 0 0
0 2 4 6 8 10 Q/m³/h 0 4 8 12 16 20 24 Q/m³/h 0 2 3 4 5 8 10 20 Q/m³/h
Design Non self-priming multistage pump with Non self-priming multistage pump with Non self-priming multistage pump
glandless pump motor integrated frequency converter
Application Water supply and pressure boosting Water supply and pressure boosting Water supply and pressure boosting
Industrial circulation systems Commerce and industry
Process engineering Cooling water circulation systems
Cooling water circulation systems Washing and sprinkling systems
Washing and sprinkling systems
Special features ƒƒ Glandless pump technology ƒƒ Easy commissioning ƒƒ All parts that come in contact with the
ƒƒ Virtually noiseless operation (up to ƒƒ All parts that come in contact with the fluid are made of stainless steel
20 dB [A] quieter than conventional fluid are made of stainless steel ƒƒ Compact design
pumps) ƒƒ Compactdesign ƒƒ WRAS/KTW/ACS approval for all parts
ƒƒ Space-saving, compact design ƒƒ Integrated frequency converter that come in contact with the fluid
ƒƒ Virtually maintenance free thanks to ƒƒ Full motor protection (EPDM version)
a design which does not feature any ƒƒ WRAS/KTW/ACS approval for all parts
mechanical seals that come in contact with the fluid
ƒƒ Drinking water approval for all com- (EPDM version)
ponents that come in contact with the
fluid (EPDM version)
Technical data ƒƒ Fluid temperature -15 to +50 °C ƒƒ Fluid temperature -15 to +110 °C ƒƒ Fluid temperature -15 to +110 °C
ƒƒ Max. operating pressure 16 bar ƒƒ Max. operating pressure 10 bar ƒƒ Max. operating pressure 10 bar
ƒƒ Max. inlet pressure 10 bar ƒƒ Inlet pressure max. 6 bar ƒƒ Inlet pressure max. 6 bar
ƒƒ Protection class IP 44 ƒƒ Protection class IP 54 ƒƒ Protection class IP 54
Equipment/function ƒƒ Multistage, non-self-priming, vertical ƒƒ Stainless steel in monobloc design ƒƒ Stainless steel pump in monobloc
high-pressure centrifugal pump in ƒƒ Threaded connection design
in-line design ƒƒ Integrated frequency converter ƒƒ Threaded connection
ƒƒ Glandless three-phase motor ƒƒ Single-phase or three-phase AC motor ƒƒ Single-phase or three-phase AC motor
ƒƒ Hydraulic connection with oval flanges ƒƒ Three-phase version with LCD ƒƒ Single-phase AC motor with integrat-
PN 16. counter flanges made of stain- ƒƒ display for status indication ed thermal motor protection
less steel with female thread, screws ƒƒ Integrated thermal motor protection
and gaskets (scope of delivery)
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
37
Product range Horizontal, multistage centrifugal Vertical, multistage centrifugal pumps Single-pump pressure boosting
pumps systems with speed-controlled pump
Water supply
Application Water supply and pressure boosting Water supply and pressure boosting Fully automated water supply in inlet
Commerce and industry Commerce and industry mode from the public water supply net-
Washing and spraying systems Washing and spraying systems work or a reservoir
Rainwater utilisation Rainwater utilisation For pumping drinking/process water,
Cooling and cold water circulation systems Cooling and cold water circuits cooling water, water for fire-fighting
Special features ƒƒ Impellers and stage chambers made of ƒƒ Space-saving, compact block design ƒƒ For systems with MVISE pump applies:
1.4301 stainless steel (AISI 304) Up to 20 dB(A) quieter than compara-
ƒƒ Pump housing made of grey cast ble systems
iron EN-GJL-250, with cataphoretic ƒƒ For systems with Helix VE pump
coating ƒƒ Optimised hydraulics
ƒƒ Cartridge mechanical seal
ƒƒ IE4 standard motor
Technical data ƒƒ Fluid temperature -15 to +90 °C ƒƒ Fluid temperature -15 to +90 °C ƒƒ Mains connection 3~400 V, 50 Hz
ƒƒ Max. operating pressure 10 bar ƒƒ Max. operating pressure or max. 10 or ƒƒ Max. fluid temperature 50 °C
ƒƒ Inlet pressure max. 6 bar 16 bar, depending on type ƒƒ Operating pressure 10/16 bar
ƒƒ Protection class IP 54 ƒƒ Max. inlet pressure 6 or 10 bar, de- ƒƒ Inlet pressure 6/10 bar
pending on type ƒƒ Protection class IP 44/IP 54
ƒƒ Protection class IP 54
ƒƒ Minimum efficiency index MEI ≥ 0.4
Equipment/function ƒƒ Pump in monobloc design ƒƒ Pump in in-line design ƒƒ All parts that come in contact with the
ƒƒ Threaded connection ƒƒ Hydraulics in 1.4301, pump housing in fluid are corrosion-resistant
ƒƒ Single-phase or three-phase AC motor EN-GJL-250 ƒƒ Pipework made of stainless steel
ƒƒ Single-phase AC motor with integrat- ƒƒ Oval flange 1.4571
ed thermal motor protection ƒƒ Single-phase or three-phase AC motor ƒƒ Shut-off device, on the pressure side
ƒƒ Non-return valve, on the pressure side
ƒƒ Diaphragm pressure vessel 8 l, PN 16
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
38 Water supply
IE
NEW NEW
Product range Single-pump pressure boosting systems Single-pump pressure boosting Multi-pump pressure boosting
system with system separation systems with speed-controlled pumps
Series Wilo-Economy CO-1 MVIS … /ER Wilo-Economy CO/T-1 Helix V … /CE Wilo-SiBoost Smart (FC) Helix V
Wilo-Economy CO-1 MVI … /ER Wilo-Comfort-Vario COR/T-1 Helix VE Wilo-SiBoost Smart Helix VE
Wilo-Economy CO-1 Helix V … /CE+ … -GE Wilo-SiBoost Smart Helix EXCEL
Field of application Water supply/pressure boosting Water supply/pressure boosting Water supply/pressure boosting
Application Fully automated water supply in inlet Fully automated water supply in inlet Fully automatic water supply/pressure
mode from the public water supply net- mode from the public water supply boosting in residential/office buildings
work or a reservoir network and in industrial systems
For pumping drinking/process water, For pumping drinking/process water, For pumping drinking/process water,
cooling water, water for fire-fighting cooling water, water for fire-fighting cooling water, water for fire-fighting
Special features ƒƒ For systems with MVIS pump applies: ƒƒ Compact system, ready for connec- ƒƒ High-efficiency pump hydraulics
Up to 20 dB(A) quieter than compara- tion, for all applications that require ƒƒ Helix V with IE3 standard motors, Helix
ble systems system separation VE with IE4, Helix EXCEL with High-
ƒƒ For systems with Helix V pump ƒƒ High-efficiency pump hydraulics efficiency EC motor (energy efficiency
ƒƒ Optimised hydraulics ƒƒ Helix V with IE3 standard motors class IE5 acc. to IEC 60034-30-2)
ƒƒ Cartridge mechanical seal ƒƒ Helix VE with IE4 standard motors ƒƒ Hydraulics of entire system are pres-
ƒƒ IE3 standard motors for Helix V sure-loss optimised
ƒƒ Integrated dry-running detection and
low water cut-out switch
Technical data ƒƒ Mains connection 3~230 V / 400 V, ƒƒ Mains connection 3~230 V / 400 V, ƒƒ Mains connection:
50 Hz 50 Hz (other versions on request) --Helix V: 3~230 V/400 V, 50 Hz
ƒƒ Max. fluid temperature 50 °C ƒƒ Max. fluid temperature 40 °C --Helix VE and EXCEL: 3~400 V, 50 Hz
ƒƒ Operating pressure 10/16 bar ƒƒ Operating pressure 16 bar ƒƒ Max. fluid temperature 70 °C
ƒƒ Inlet pressure 6/10 bar ƒƒ Inlet pressure 6 bar ƒƒ Operating pressure 16 bar (25 bar
ƒƒ Switching pressure stages 6 / 10 / ƒƒ Protection class CO/T=IP 54, optional)
16 bar COR/T=IP 55 ƒƒ Inlet pressure 10 bar
ƒƒ Protection class IP 41/IP 54 ƒƒ Protection class IP 54
Equipment/function ƒƒ Components that come in contact ƒƒ PE break tank, atmospherically venti- ƒƒ Automatic pump control via Smart
with fluid are corrosion-resistant lated (150 l) Controller SC
ƒƒ Base frame made of stainless steel ƒƒ Components that come in contact ƒƒ New innovative pressure-variable
1.4301 with height-adjustable vibra- with fluid are corrosion-resistant control for Helix VE and EXCEL
tion absorbers for insulation against ƒƒ Pipework made of stainless steel ƒƒ Components in contact with fluid are
structure-borne noise 1.4307 corrosion-resistant
ƒƒ Pipework made of stainless steel ƒƒ Shut-off device, on the pressure side ƒƒ Shut-off device on suction and pres-
1.4571 ƒƒ Non-return valve, on the pressure side sure sides of each pump
ƒƒ Shut-off device, on the pressure side ƒƒ Break tank including float valve and ƒƒ Non-return valve, pressure sensor,
ƒƒ Non-return valve, on the pressure side float switch diaphragm pressure vessel 8 l, PN 16,
ƒƒ Diaphragm pressure vessel 8 l, PN 16, ƒƒ Diaphragm pressure vessel 8 l, PN 16, on pressure side
on pressure side on pressure side ƒƒ Low-water sensor standard for VE and
ƒƒ Low-water cut-out switchgear EXCEL
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
39
Product range Multi-pump pressure boosting Multi-pump pressure boosting Multi-pump pressure boosting systems
systems with speed-controlled pumps systems with speed-controlled pumps
Series Wilo-Comfort-Vario-COR 2-4 MHIE … /VR Wilo-Comfort-N-COR 2-6 MVIS … /CC Wilo-Economy CO 2-4 MHI … /ER
Wilo-Comfort-N-Vario-COR 2-4 MVISE … /VR Wilo-Comfort-COR 2-6 MVI … /CC Wilo-Economy CO 2-4 Helix … /CE
Wilo-Comfort-Vario-COR 2-4 MVIE … /VR Wilo-Comfort-COR 2-6 Helix V … /CC Wilo-Comfort-N-CO 2-6 MVIS … /CC
Wilo-Comfort-COR 2-6 Helix VE … /CCe Wilo-Comfort-CO 2-6 MVI or Helix V… /CC
Field of application Water supply/pressure boosting Water supply/pressure boosting Water supply/pressure boosting
Water supply
Application Fully automatic water supply/pressure Fully automatic water supply/pressure Fully automatic water supply/pressure
boosting in residential/office buildings boosting in residential/office buildings boosting in residential/office buildings
and in industrial systems and in industrial systems and in industrial systems
For pumping drinking/process water, For pumping drinking/process water, For pumping drinking/process water,
cooling water, water for fire-fighting cooling water, water for fire-fighting cooling water, water for fire-fighting
Special features ƒƒ Compact system due to high-pressure, ƒƒ Compact system in accordance of ƒƒ Compact system in accordance of
multistage centrifugal pumps with DIN 1988 (EN 806) DIN 1988 (EN 806)
integrated frequency converters ƒƒ Series with Helix VE integrated fre- ƒƒ For systems with MVIS pumps applies:
ƒƒ Integrated full motor protection quency converter Up to 20 dB(A) quieter than compara-
via PTC ƒƒ For systems with MVIS pumps applies: ble systems
ƒƒ Integrated dry-running detection and Up to 20 dB(A) quieter than compara-
low water cut-out switch ble systems
ƒƒ For systems with MVISE pumps
applies: Up to 20 dB(A) quieter than
comparable systems
Technical data ƒƒ Mains connection 3~400 V, 50/60 Hz, ƒƒ Mains connection 3~230 / 400 V, ƒƒ Mains connection 3~230 V / 400 V,
depending on type also 1~230 V, 50 Hz 50 Hz
50/60 Hz ƒƒ Max. fluid temperature 50 °C ƒƒ Max. fluid temperature 50 °C
ƒƒ Max. fluid temperature 70 °C ƒƒ Operating pressure 10/16 bar ƒƒ Operating pressure 10/16 bar
ƒƒ Operating pressure 10/16 bar ƒƒ Inlet pressure 6/10 bar ƒƒ Inlet pressure 6/10 bar
ƒƒ Inlet pressure 6/10 bar ƒƒ Protection class IP 54 ƒƒ Protection class IP 54
ƒƒ Protection class IP 54
Equipment/function ƒƒ Continuous auto control due to pumps ƒƒ Continuous auto control of the base- ƒƒ Components that come in contact
with integrated frequency converters load pump via frequency converter with fluid are corrosion-resistant
ƒƒ Components that come in contact integrated in the CC controller ƒƒ Pipework made of stainless steel
with fluid are corrosion-resistant ƒƒ Components that come in contact 1.4571
ƒƒ Pipework made of stainless steel with fluid are corrosion-resistant ƒƒ Shut-off device at each pump, on the
1.4571 ƒƒ Pipework made of stainless steel suction and pressure sides
ƒƒ Shut-off device at each pump, on the 1.4571 ƒƒ Non-return valve, on the pressure side
suction and pressure sides ƒƒ Shut-off device at each pump, on the ƒƒ Diaphragm pressure vessel 8 l, PN 16,
ƒƒ Non-return valve, on the pressure side suction and pressure sides on pressure side
ƒƒ Diaphragm pressure vessel 8 l, PN 16, ƒƒ Non-return valve, on the pressure side ƒƒ Pressure sensor, on the discharge side
on pressure side ƒƒ Diaphragm pressure vessel 8 l, PN 16,
ƒƒ Pressure sensor, on the discharge side on pressure side
ƒƒ Pressure sensor, on the discharge side
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
40 Water supply
Series modification
Product range Fire-fighting systems for wall hydrant Fire fighting systems for wall hydrant Fire fighting systems for sprinkler sys-
installations according to DIN 14462 installations according to DIN 14462 tems according to EN 12845
Special features ƒƒ Compact system in accordance of ƒƒ Compact system with break tank in ƒƒ Compact system (just one base frame)
DIN 14462 accordance with DIN 14462 in accordance with EN 12845
ƒƒ Variants ƒƒ Variants ƒƒ Jockey pump for maintaining the
ƒƒ Single-pump system ƒƒ Single-pump system required pressure in the system; with
ƒƒ Double-pump system with redundant ƒƒ Double-pump system with two automatic start/stop function
single-pump systems in a base frame redundant single-pump systems on a ƒƒ Sized diaphragm at the pump outlet
ƒƒ Comes as standard with pump pro- base frame for a minimum bypass line so that the
tection by means of minimum volume ƒƒ Comes as standard with pump pro- pump is protected at a low volume
discharge via bypass circuit without tection by means of minimum volume flow
auxiliary energy discharge via bypass circuit without ƒƒ The cables are hidden in the con-
auxiliary energy struction and are thus protected from
shocks or cuts
Technical data ƒƒ Mains connection 3~400 V, 50 Hz ƒƒ Mains connection 3~400 V, 50 Hz ƒƒ Mains connection 3~400 V, 50 Hz
ƒƒ Max. fluid temperature 50 °C ƒƒ Fluid temperature max. 50 °C (1~230 V, 50 Hz panel diesel pump)
ƒƒ Max. operating pressure 16 bar ƒƒ Operating pressure up to 16 bar ƒƒ Fluid temperature max. +40 °C
ƒƒ Inlet pressure 6 bar ƒƒ Inlet pressure from break tank < 1 bar ƒƒ Max. operating pressure 10 bar or
ƒƒ Protection class IP 54 ƒƒ Protection class of operating device 16 bar
IP 54 ƒƒ Max. inlet pressure 6 bar
ƒƒ Round break tank (540 l) ƒƒ Protection class of the switch cabinet
IP54
Equipment/function ƒƒ Components that come in contact ƒƒ Components in contact with the fluid ƒƒ A circuit with double pressure switch,
with fluid are corrosion-resistant are corrosion-resistant pressure gauge, non-return valve,
ƒƒ Pipework made of stainless steel ƒƒ Pipework made of stainless steel valve for the main and standby pump
1.4301 1.4301 for an automatic start
ƒƒ Shut-off device at each pump, on the ƒƒ Ball shut-off valve on pressure side ƒƒ Pipework in steel; painted with epoxy
suction and pressure sides ƒƒ Gate valve between pump and break resin. Distributor with flanges
ƒƒ Non-return valve, on the pressure side tank with free outlet according to ƒƒ Shutting gate with safety lock on the
ƒƒ Diaphragm pressure vessel 8 l, PN 16, ƒƒ EN 13077, type AB according to pressure side of the pump
on pressure side ƒƒ DIN EN 1717 ƒƒ Non-return valve on the pressure side
ƒƒ Pressure switch, on the discharge side ƒƒ Non-return valve, on pressure side of every pump
ƒƒ Diaphragm pressure vessel 8 l, PN16, ƒƒ DN2" connection for the break tank of
arranged on the pressure side the pumps
ƒƒ Pressure switch, on pressure side ƒƒ Pressure measuring on pressure side
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
41
Product range Certified fire fighting systems for hy- Submersible pumps Submersible pumps
drant and sprinkler systems according
to EN 1717, EN 12056, DIN 14462 or
EN 12845
Series Wilo-GEP Fire Wilo-Sub TWU 3 Wilo-Sub TWU 4 …
Wilo-Sub TWU 3-...-HS Wilo-Sub TWU 4 …-QC
Wilo-Sub TWU 4 ...-GT
Field of application Fire fighting Rainwater utilisation, raw water intake Rainwater utilisation, raw water intake
Water supply
Application Fire-fighting water with exterior hydrants Water supply: boreholes, wells and Water supply: boreholes, wells, rainwater
and fire hose reels particularly for high- rainwater tanks; domestic water supply, tanks; sprinkling, irrigation, pressure
rise buildings and large properties - with- sprinkling and irrigation; pumping of boosting; lowering ground water level;
out using valves for pressure reduction water without long-fibre or abrasive pumping of water without long-fibre or
- for sprinkler and water spray systems components abrasive components
Special features ƒƒ Room air cooling ƒƒ Parts in contact with the fluid are ƒƒ Parts in contact with the fluid are
ƒƒ Split version for installation/transport corrosion-resistant corrosion-resistant
ƒƒ Pressure maintaining pump or pilot ƒƒ Integrated non-return valve ƒƒ Integrated non-return valve
pump as an option ƒƒ Supply security with constant pressure ƒƒ Low wear due to floating impellers
ƒƒ Combination with industrial water thanks to extended pump performance ƒƒ Maintenance-friendly motor
system due to a higher speed of up to 8,400
ƒƒ Real pressure method and VR control- rpm (TWU 3/HS)
ler for high-rise buildings and large ƒƒ Frequency converter with integrated
properties and menu-guided control
ƒƒ Monitoring of the switchgear and the ƒƒ (TWU 3/HS)
equipment environment temperature
ƒƒ Complete unit casing
Technical data ƒƒ Certified system - TÜV, DEKRA, DVGW, ƒƒ Mains connection: 1~230 V, 50 Hz or ƒƒ Mains connection: 1~230 V, 50 Hz or
SVGW 3~400 V, 50 Hz 3~400 V, 50 Hz
ƒƒ Hygienic safety due to free outlet (EN ƒƒ Fluid temperature: 3-35 °C ƒƒ Fluid temperature: 3-30 °C
1717) ƒƒ Minimum flow rate at motor: 0.08 m/s ƒƒ Minimum flow rate at motor: 0.08 m/s
ƒƒ Stainless steel run-down tank ƒƒ Max. sand content: 50 g/m³ ƒƒ Max. sand content: 50 g/m³
ƒƒ Automatic function test up to redun- ƒƒ Max. number of starts: 30/h ƒƒ Up to 20 starts per hour
dancy stage 3 ƒƒ Max. immersion depth: 150 m ƒƒ Max. immersion depth: 200 m
ƒƒ Small installation surface min. 0.64 m² ƒƒ Pressure connection: Rp 1 ƒƒ MEI: up to ≥ 0.7
Equipment/function ƒƒ Drainage or pump emergency drainage ƒƒ Multistage submersible pump with ƒƒ Multistage submersible pump with
(EN12056) for total volume flow radial impellers radial or semi-axial impellers
ƒƒ Installation possible below backflow ƒƒ Integrated non-return valve ƒƒ Integrated non-return valve
level ƒƒ NEMA coupling ƒƒ NEMA coupling
ƒƒ No valves for reducing pressure in the ƒƒ Single-phase or three-phase AC motor ƒƒ Single-phase or three-phase AC motor
main flow of the fire extinguishing ƒƒ Thermal motor protection for ƒƒ Integrated thermal motor protection
system ƒƒ single-phase motor for single-phase motor
ƒƒ Effective maintenance management ƒƒ HS variant including external or inter- ƒƒ Hermetically sealed motors
and permanent information on the nal frequency converter
operation via smartphone, tablet or PC
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
42 Water supply
NEW
Series Wilo-Actun OPTI-MS Wilo-Sub TWU 3 … Plug & Pump Wilo-Sub TWI 4/6/8/10 …
Wilo-Sub TWU 4 … Plug & Pump
Field of application Rainwater utilisation, raw water intake Rainwater utilisation, raw water intake Water supply/pressure boosting, clean
water treatment, rainwater utilisation,
raw water intake, desalination, irrigation
+P
Q/m³/h Wilo-Actun OPTI-MS :LOR6XE7:83 3 :LOR6XE
12 7:83 3 440 7:,
10 80 360
8
60 280
7:83 3
6 7:83 3
40 200
4
120
2
20
40
0 0 0
0 400 800 1200 1600 2000 2400 2800P1/kW 0 1 2 3 4 5 4PåK 0 1 5 10 20 4PåK 200
Design Submersible pump, multistage Water-supply unit with submersible Submersible pump, multistage
pump, control and complete accessories
Application Water supply: boreholes, wells, rainwater Water supply system for water supply Water supply (also drinking water): bore-
tanks; sprinkling, irrigation; pumping from boreholes, wells and rainwater holes, rainwater tanks; municipal/industrial;
of water without long-fibre or abrasive tanks; domestic water supply, sprinkling sprinkling, irrigation; pressure boosting;
components and irrigation; pumping of water without lowering ground water; pumping of water
long-fibre or abrasive components without long-fibre or abrasive components
Special features ƒƒ Powered by renewable energy sources ƒƒ Easy installation thanks to pre-mount- ƒƒ Corrosion-resistant thanks to stainless
ƒƒ All parts in contact with the fluid are ed and pre-wired components steel version
made of stainless steel ƒƒ Parts in contact with the fluid are ƒƒ Flexible installation thanks to vertical
ƒƒ Integrated non-return valve corrosion-resistant and horizontal installation
ƒƒ Low wear due to floating impellers ƒƒ Integrated non-return valve ƒƒ Easy installation due to integrated
ƒƒ Types with helical rotor for high head non-return valve
at low speed ƒƒ Large performance range
ƒƒ AC permanent magnet motor ƒƒ ACS approval for TWI 4 for drinking
ƒƒ Built-in inverter module with MPPT water application
function
Technical data ƒƒ Operating voltage range: 90-400 VDC ƒƒ Mains connection: 1~230 V, 50 Hz ƒƒ Mains: 1~230 V, 50 Hz
or 90-265 VAC ƒƒ Fluid temperature: 3-30 °C ƒƒ (only TWI 4 …) or 3~400 V, 50 Hz
ƒƒ Fluid temperature max.: 35 °C ƒƒ Minimum flow rate at motor: 0.08 m/s ƒƒ Immersed operating mode: S1
ƒƒ Minimum flow rate at motor: 0.2 m/s ƒƒ Max. sand content: 50 g/m³ ƒƒ Fluid temperature: 3-20 °C or 3-30 °C
ƒƒ Max. sand content: 50 g/m³ ƒƒ Up to 20 starts per hour ƒƒ Min. flow rate at motor: 0.08-0.5 m/s
ƒƒ Max. immersion depth: 150 m ƒƒ Max. immersion depth TWU 3/TWU 4: ƒƒ Max. sand content: 50 g/m³
150/200 m ƒƒ Up to 10 or 20 starts per hour
ƒƒ MEI: ≥ 0.7 (TWU 4) ƒƒ Max. immersion depth: 100-350 m
Equipment/function ƒƒ Type MSI: Multistage submersible ƒƒ Multistage submersible pump with ƒƒ Multistage submersible pump with
pump with radial impellers in jacket radial impellers radial or semi-axial impellers
design ƒƒ Integrated non-return valve ƒƒ Integrated non-return valve
ƒƒ Type MSH: Hydraulics with helical rotor ƒƒ NEMA coupling ƒƒ NEMA coupling
within double helix rubber stator ƒƒ Single-phase AC motor ƒƒ Single-phase or three-phase
ƒƒ Integrated non-return valve ƒƒ Integrated thermal motor protection ƒƒ AC motor
ƒƒ AC permanent magnet motor, capsu- ƒƒ Dry-running protection (only for TWU
lated, water-cooled 4- … -P&P with Wilo-Sub-I package)
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
43
NEW
Product range Submersible pumps Sprinkler pumps with VdS approval Submersible pumps
+P
Wilo-MMI 50 V
'..0 ǒǒǒ
160 480
120
400
120 100
80 320
80 60 240
ǒ ǒ ǒǒ
40 160
40
20 80
0 0 0
0 5 10 15 20 25 Q/m³/h 30 50 70 100 200 300 4PåK 1 2 3 5 10 20 50 100 4OV
Design Multistage submersible pump Submersible pump with sectional con- Submersible pump with sectional con-
struction struction
Water supply
Application Pumping clean/slightly contaminated Supplying sprinkler systems Potable and other water from boreholes,
water (industrial process or clean water rainwater tanks; process water; municipal/
treatment), for small installation spaces. industrial water supply; sprinkling/irrigation;
Installation in tanks, vessels, rainwater pressure boosting; lowering the ground water
storage tanks and chambers level; geothermal and offshore applications
Technical data ƒƒ Permitted temperature range -20 °C ƒƒ Mains connection: 3~400 V/50 Hz ƒƒ Mains connection: 3~400 V, 50 Hz
to +120 °C ƒƒ Max. fluid temperature: 25 °C or on ƒƒ Max. fluid temperature: 20 ... 30 °C
ƒƒ Nominal diameter on pressure side request ƒƒ Minimum flow rate at motor: 0.1 ... 0.5 m/s
DN 32 to DN 100 ƒƒ Minimum flow rate at motor: 0.1 m/s ƒƒ Max. sand content:
ƒƒ Max. operating pressure PN 10 or ƒƒ Max. sand content: 35 g/m³ ƒƒ 35 g/m³ or 150 g/m³
PN 16 ƒƒ Up to 10 starts per hour ƒƒ Up to 10 starts per hour
ƒƒ Mains connection 3~400 V, 50 Hz ƒƒ Max. immersion depth: 100 m or ƒƒ Max. immersion depth: 100/300/350 m
ƒƒ Max. viscosity 150 cSt 300 m ƒƒ MEI: up to ≥ 0.7
Equipment/function ƒƒ VCS: adjustable base and fixed cou- ƒƒ Multistage submersible pump ƒƒ Multistage submersible pump
pling ƒƒ Radial or semi-axial impellers ƒƒ Radial or semi-axial impellers
ƒƒ VEM: cast iron support and fixed ƒƒ NEMA coupling (depending on type) ƒƒ Hydraulics and motor freely
coupling ƒƒ Three-phase motor for direct or ƒƒ configurable according to power
ƒƒ VTM: bearing block and semi-elastic star-delta start requirements
coupling ƒƒ Rewindable motors ƒƒ Integrated non-return valve
ƒƒ VTMRI: bearing block and semi-elastic ƒƒ (depending on type)
coupling with internal drain (shaft seal) ƒƒ NEMA coupling or standardised
for small installation spaces ƒƒ connection
ƒƒ VRI: cast iron support, fixed coupling ƒƒ Three-phase motor for direct or
and internal drain (shaft seal) for small star-delta start
installation spaces
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
44 Water supply
Product range Submersible pumps Vertical turbine pumps Standard glanded pumps
Field of application Water supply/pressure boosting, clean Water supply/pressure boosting, indus- Heating, air conditioning, cooling, water
water treatment, raw water intake, desal- trial process supply, industrial process
ination, dewatering, industrial process
Wilo-CronoNorm-NL
.3.03'3 140
140 120
120
100
100
80
80
60 60
40 40
20 20
0 0
10 20 30 40 50 100 160 4OV 0 100 200 300 400 500 Q/m³/h
Design Polder pump Vertical turbine pumps for dry well instal- Single-stage low-pressure centrifugal
lation with submerged axial or semi-axial pump with axial suction, according to
hydraulics EN 733 and ISO 5199, mounted on a
baseplate
Application Potable and process water from tanks Industrial or municipal water supply Pumping of heating water, cold water and
or shallow bodies of water; municipal/ irrigation, fire fighting water-glycol mixtures without abrasive
industrial water supply; sprinkling, irri- Cooling water supply substances. Applications in municipal
gation; lowering the ground water level; Dewatering, flood control water supply, irrigation, general industry,
geothermal and offshore applications power stations etc.
Special features ƒƒ Deep water lowering thanks to ƒƒ Minimum surface area needed ƒƒ Reduced life-cycle costs through
self-cooling motors ƒƒ High hydraulic efficiency optimised efficiency levels
ƒƒ Sturdy version in cast iron or bronze ƒƒ Submerged pump hydraulics ƒƒ Bidirectional, force-flushed mechan-
ƒƒ Compact construction ƒƒ Design to order as per customer ical seal
ƒƒ Maintenance-friendly, rewindable specifications ƒƒ Low NPSH values, best cavitation
motors properties
ƒƒ Optionally with Ceram CT coating for ƒƒ Shaft coupling with or without spacer
increasing the efficiency coupling
Technical data ƒƒ Mains connection: 3~400 V, 50 Hz ƒƒ Permitted temperature range up to ƒƒ Fluid temperature -20 °C to +120 °C
ƒƒ Max. fluid temperature: 20 °C 80 °C, or up to 105 °C on request ƒƒ Mains connection 3~400 V, 50 Hz
ƒƒ Minimum flow across outside shroud: ƒƒ Nominal diameter on pressure side ƒƒ Minimum efficiency index (MEI) ≥ 0.4
not necessary DN 100 to DN 2000 ƒƒ Nominal diameter: DN 50 to DN 500
ƒƒ Max. sand content: 35 g/m3 (suction side), DN 32 to DN 500
ƒƒ Up to 10 starts per hour (pressure side)
ƒƒ Max. immersion depth: 300 m ƒƒ Operating pressure: depending on type
and application – up to 16 bar
Equipment/function ƒƒ Multistage submersible pump ƒƒ For types of installation with pressure ƒƒ Single-stage horizontal spiral housing
ƒƒ Semi-axial impellers port, for concealed floor, floor-mount- pump with bearing bracket and
ƒƒ Hydraulics and motor freely ed or twin-ceiling installation exchangeable casing wear rings in
ƒƒ configurable according to power ƒƒ Design: process design
requirements --As removable or permanent ƒƒ Shaft sealing with mechanical seals in
ƒƒ Three-phase motor for direct or --installation accordance with EN 12756 or stuffing
star-delta start --With axial or semi-axial, single or box packing
ƒƒ Motors rewindable as standard multistage hydraulics ƒƒ Spiral housing with cast pump support
--With open shaft for bearing lubrica- feet
tion with the fluid, or with shaft trim ƒƒ Shaft coupling with spacer coupling
for separate bearing lubrication ƒƒ Motors with efficiency class IE3 for
ƒƒ Drive options: Electric motor, diesel motors ≥ 0.75 kW
motor or steam turbine
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
45
Product range Standard glanded pumps Axially split case pumps Standard pumps in accordance
with EN 733
Field of application Heating, air conditioning, cooling, water Cooling, air-conditioning, water supply/ Industrial process
supply, industrial process pressure boosting, industrial process
Water supply
Application Pumping of heating water, cold water and Pumping of heating water in accordance Industrial process, non-hygienic food
water-glycol mixtures without abrasive with VDI 2035, water-glycol mixtures, cool- industry, power generation, water cir-
substances. Applications in municipal ing/cold water and process water, municipal culation in the metals industry, heating,
water supply, irrigation, general industry, water supply, irrigation, building services, cold water and cooling water systems
power stations etc. general industry, power stations etc.
Special features ƒƒ NLG: ƒƒ Higher volume flows up to 17,000 on ƒƒ Impeller diameter is adjusted to the
--Reduced life cycle costs through request desired duty point
optimised efficiency ƒƒ Special motors and other materials on ƒƒ Many version options for the shaft seal
--Bidirectional mechanical seal request ƒƒ 60 Hz or ATEX version on request
--Replaceable casing wear ring ƒƒ Pumping of clean or slightly muddy
--Permanently lubricated, generously fluids without solid material
dimensioned roller bearings
ƒƒ NPG:
--Suitable for temperatures up to
140 °C
--Back pull-out version
Technical data ƒƒ Fluid temperature -20 °C to +120 °C ƒƒ Fluid temperature -8 °C to +120 °C ƒƒ Permitted temperature range -20 °C
(depending on type) ƒƒ Mains connection 3~400 V, 50 Hz to +120 °C
ƒƒ Mains connection 3~400 V, 50 Hz ƒƒ Protection class IP 55 ƒƒ Mains connection 3~400 V, 50 Hz
ƒƒ Minimum efficiency index (MEI) ≥ 0.4 ƒƒ Nominal diameters - Suction side: DN ƒƒ Nominal diameter on pressure side
ƒƒ Nominal diameters: DN 150 to DN 500 65 to DN 500 DN 32 to DN 125
(depending on type) ƒƒ Pressure side: DN 50 to DN 400 ƒƒ Max. operating pressure PN 16
ƒƒ Operating pressure: depending on ƒƒ Max. operating pressure:
type and application – up to 16 bar ƒƒ 16 or 25 bar, depending on type
Equipment/function ƒƒ Single-stage horizontal spiral housing ƒƒ 1- or 2-stage, low-pressure centrifu- ƒƒ Dimensions and hydraulic output as
pump with bearing bracket and gal pump in monobloc design per EN 733
exchangeable casing wear rings (NLG ƒƒ Deliverable as complete unit or with- ƒƒ Hydraulics made from cast iron (ML)
only) in process design out motor or only pump hydraulics or stainless steel (MX) depending on
ƒƒ Shaft sealing with mechanical seals in ƒƒ Shaft sealing with mechanical seal or version
accordance with EN 12756 or stuffing stuffing box packing ƒƒ Sealed by uncooled mechanical seal
box packing ƒƒ 4-pole and 6-pole motors ƒƒ Version with or without spacer cou-
ƒƒ Spiral housing with cast pump bases ƒƒ Materials: pling
ƒƒ Greased grooved ball bearings for --Pump housing: EN-GJL-250 ƒƒ 2 or 4-pole IEC standard motor
bearing of pump shaft --Impeller: G-CuSn5 ZnPb ƒƒ Baseplate made from steel or cast iron
ƒƒ Motors with efficiency class IE3 --Shaft: X12Cr13 ƒƒ Supplied as a complete unit: with
pump, coupling, coupling guard, motor
and baseplate or without motor or
pump only, with free shaft end
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
46 Water supply
Product range Standard pumps in accordance Standard pumps in accordance Self-priming drainage pumps
with EN 733 and EN 22858 with EN 733
Field of application Industrial process Industrial process Water supply/pressure boosting, profes-
sional irrigation/agriculture, dewatering/
flood control
Duty chart H/m Wilo-NESD / NESE H/m Wilo-NFCH H/m Wilo-Drain LP / LPC
100 100 30
50 25
50
20
20 20
15
10 10 10
5 5 5
0 2 0
0 5 10 50 100 500 Q/m³/h 2 5 10 50 100 500 Q/m³/h 0 10 20 30 40 50 Q/m³/h
Design Single-stage low-pressure centrifugal Single-stage low-pressure centrifugal Self-priming drainage pumps for dry well
pump with axial suction connection and pump with axial suction connection and installation
radial, upwards-facing pressure connec- radial, upwards-facing pressure con-
tion mounted on a baseplate nec-tion, mounted on a baseplate
Application For heat transfer or circulating hot water For pumping mineral or synthetic For pumping wastewater with small
in industrial processes, for power genera- heat-carrier fluids up to 350 °C, e.g.: in amounts of solid matter for excavation
tion or in building services industrial processes or power generation pits and ponds, sprinkling/spraying of
gardens and green areas, drainage of
seepage water and mobile drainage
Special features ƒƒ Impeller diameter is adjusted to the ƒƒ Impeller diameter is adjusted to the ƒƒ Long service life
desired duty point desired duty point ƒƒ Sturdy construction
ƒƒ 60 Hz or ATEX version on request ƒƒ 60 Hz or ATEX version on request ƒƒ Easy operation
ƒƒ Special self-cooling design allows use ƒƒ Self-cooling design with double ƒƒ Flexible use
of an uncooled shaft seal. Additional temperature barrier allows the use of
or external cooling devices are not an uncooled shaft seal and reduces
required heat loss
Technical data ƒƒ Max. permitted fluid temperature ƒƒ Permitted temperature range: 0 °C ... ƒƒ Mains connection: 1~230 V, 50 Hz,
--NESD: 207 °C 120 °C (16 bar), 120 °C … 300 °C (13 3~400 V, 50 Hz
-- NESE: 0 °C ... 120 °C (40 bar), 120 °C … bar), 300 °C ... 350 °C (16 bar) ƒƒ Fluid temperature 3 °C to 35 °C
200 °C (35 bar), 200 °C ... 230 °C (32 bar) ƒƒ Nominal diameter on pressure side ƒƒ Free ball passage 5 to 12 mm,
ƒƒ Minimum fluid temperature: 170 °C DN 32 to DN 125 ƒƒ depending on type
ƒƒ Nominal-Ø pressure side: DN 32 - 125 ƒƒ Max. operating pressure PN 16 ƒƒ Connection Rp 1½ to G3
ƒƒ Max. operating pressure
ƒƒ NESD: PN 25; NESE: PN 40
Equipment/function ƒƒ Dimensions and hydraulic output as ƒƒ Dimensions and hydraulic output as ƒƒ Portable self-priming centrifugal
per EN 22858 per EN 733 pump
ƒƒ Hydraulics in spheroidal cast iron EN- ƒƒ Standard mechanical seal correspond-
GS400 (MG version) ing to the heat-carrier fluid
ƒƒ Flange version in accordance with ƒƒ Version with or without spacer cou-
EN 1092-1 pling
ƒƒ With or without spacer coupling ƒƒ 2 or 4-pole IEC standard motor 50 Hz
ƒƒ 2 or 4-pole IEC standard motor 50 Hz ƒƒ Supplied as a complete unit: with
ƒƒ Baseplate steel or cast iron pump, coupling, coupling guard, motor
ƒƒ Supplied as a complete unit: with and baseplate or without motor or
pump, coupling, coupling guard, motor pump only, with free shaft end
and baseplate or without motor or
pump only, with free shaft end
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
47
Product range Pedestal pumps Submersible sewage pumps Hot-water pressure-boosting pumps
Field of application Professional irrigation/agriculture, special Raw water intake, wastewater treatment, Water supply/pressure boosting
applications, dewatering/flood control, dewatering/flood control
industrial process
Water supply
Application Pumping of wastewater and condensate Pumping cooling or rainwater, cleaned Domestic water supply from a water tank
up to 95 °C from pump sumps and from sewage and for irrigation and pumping
cellars at risk of flooding sludge
Special features ƒƒ For fluids up to 95 °C ƒƒ Installation directly in the pressure ƒƒ Easy: …S…A versions for all in one
ƒƒ Long service life pipe water booster
ƒƒ Easy operation with attached float ƒƒ Angle of propeller blades adjustable ƒƒ Efficient: High-efficiency motor (IE2 or
switch ƒƒ Process security thanks to extensive IE3 depending on versions)
ƒƒ Long standstill times possible monitoring devices
ƒƒ Integrated motor protection with ƒƒ Low vibrations and long standstill
thermal relay times thanks to high-quality compo-
nents
Technical data ƒƒ Mains connection: 1~230 V, 50 Hz or ƒƒ Mains connection: 3~400 V, 50 Hz ƒƒ Mains connection: 1~230 V, 50/60 Hz
3~400 V, 50 Hz ƒƒ Immersed operating mode: S1 (depending models)
ƒƒ Protection class IP 54 ƒƒ Protection class: IP 68 ƒƒ Fluid temperature from 5°C to +80°C
ƒƒ Fluid temperature +5 °C to +95 °C ƒƒ Max. fluid temperature: 40 °C (depending models)
ƒƒ Free ball passage 5 or 7 mm, ƒƒ Free ball passage of 85 to 130 mm ƒƒ Ambient temperature from 0°C to +40°C
ƒƒ depending on type ƒƒ Short common pump/motor shaft ƒƒ Max suction pressure: From 0.4 bars up
ƒƒ Pressure port Rp 1 or Rp 1½ ƒƒ Permanently lubricated roller bearings to 1.4 bars
ƒƒ depending on type ƒƒ Max. immersion depth: 20 m ƒƒ Protection class 1~: IP X4
Equipment/function ƒƒ Attached float switch ƒƒ Heavy-duty version made of cast iron ƒƒ Directly flanged motor
ƒƒ Thermal motor protection switch for
1~230V version
ƒƒ Flow sensor for automatic pump start
PB-…A
ƒƒ Flow sensor, pressure switch and pres-
surised tank for automatic pump start
and protection of versions PB-…S…A
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
48 Water supply
Application Water supply from a water tank Water supply from a water tank
Sprinkling from a water tank Sprinkling from a water tank
Irrigation and spraying from a water tank Irrigation and spraying from a water tank
Rainwater utilisation from a water tank Rainwater utilisation from a water tank
Special features ƒƒ Easy: PU-S… versions for salt water ƒƒ Easy: S…A versions for all in one water
ƒƒ Efficient: Self-priming automatic booster
peripheral pumps up to 8m ƒƒ Efficient: Self-priming automatic
ƒƒ Efficient: High-efficiency motor (IE2 or peripheral pumps up to 8m
IE3 depending on versions) ƒƒ Efficient: High efficiency motor (IE2 or
IE3 depending on versions)
Technical data ƒƒ Mains connection 1~230 V, 50/60 Hz ƒƒ Mains connection 1~230 V, 50/60 Hz
(depending models) (depending models)
ƒƒ Fluid temperature from +0°C to +60°C ƒƒ Fluid temperature from +5°C to +40°C
ƒƒ Ambient temperature from 0°C to ƒƒ Ambient temperature from 0°C to
+40°C +40°C
ƒƒ Max suction pressure: From 1.0 bar up ƒƒ Max suction pressure: From 0.7 bar up
to 1.4 bar to 1.4 bar
ƒƒ Protection class 1~: IP X4 ƒƒ Protection class 1~: IP X4
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
WILO BRINGS
THE FUTURE.
Ground-breaking solutions for an ever more complex world.
Water management worldwide faces complex tasks. Scarcity of resources and urbani-
sation require efficient systems to reliably transport and treat water. The key question
is: what might the sustainable, effective water infrastructure of tomorrow look like? We
do not have just the one answer, but a whole range – each individually tailored to each
project. As a solutions provider we assist our customers in a holistic manner, from plan-
ning to maintenance and support them with intelligent networking during digitisation.
Water supply
50 Drainage and sewage
RELIABLE
WASTEWATER SYSTEMS
FOR GROWING CITIES.
PUMPS AND SYSTEMS FOR WASTEWATER COLLECTION AND
TRANSPORT, SEWAGE TREATMENT, DRAINAGE AND FLOOD
CONTROL.
51
More and more people live in cities and these habitats of the future pose us major challenges. One of these challenges
is the disposal of wastewater and sewage to comply with hygiene standards and prevent unpleasant odours. Wherever
sewage does not simply flow into the sewer system via gravity, efficient sewage pumps and lifting units come into play.
The powerful and particularly economical products and systems from Wilo collect and transport sewage reliably and in
a resource-friendly way. And with the development of effective solutions for sewage treatment, we help protect the
environment and contribute to sustainable use of water – one of life’s most valuable resources.
Product range Self-priming drainage pumps Submersible drainage pumps Pedestal pumps
Field of application Water distribution/boosting, dewatering/ Dewatering/flood control, industrial Dewatering/flood control, industrial
flood control process process
+P
Wilo-Drain LP / LPC :LOR'UDLQ707 :LOR'UDLQ9&
30 16
14 16
25
12
20 10 12
15 8
6 8
10
4 4
5 2
0 0 0
0 10 20 30 40 50 Q/m³/h 0 4 8 12 16 20 4PåK 0 2 4 6 8 10 12 4PåK
Design Non-submersible self-priming drainage Submersible drainage pump Non-submersible pedestal pump with
pump standard motor
Technical data ƒƒ Mains connection: 1~230 V or 3~400 V ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 1~230 V or 3~400 V
ƒƒ Fluid temperature: max. 35 °C ƒƒ Immersed operating mode: S1 ƒƒ Operation mode: S1
ƒƒ Operation mode: S1 ƒƒ Non-immersed operating mode: S3 ƒƒ Protection class: IP 54
25 % ƒƒ Fluid temperature: max. 95 °C
ƒƒ Protection class: IP 68
ƒƒ Max. immersion depth: 7 m
ƒƒ Fluid temperature: max. 95 °C
Equipment/function ƒƒ Portable self-priming centrifugal ƒƒ Housing and impeller made of grey ƒƒ Attached float switch
pump cast iron
ƒƒ Thermal motor monitoring
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
53
NEW
Product range Submersible drainage pumps Submersible drainage pumps Submersible drainage pumps
Field of application Wastewater collection and transport, Wastewater collection and transport, Wastewater collection and transport,
dewatering/flood control dewatering/flood control dewatering/flood control
Duty chart H/m Wilo-Drain TS / TSW +P :LOR'UDLQ H/m Wilo-Padus UNI
14
10 TM / TMR / TMW 76 25
12
8 20
10
6 8 15
4 6 10
4
2 5
2
0 0 0
0 2 4 6 8 10 12 Q/m³/h 0 2 4 6 8 10 12 14 4PvK 0 2 4 6 8 10 12 Q/l/s
Design Submersible drainage pump Submersible drainage pump Submersible drainage pump
Special features ƒƒ TMW, TSW with turbulator for ƒƒ Low weight ƒƒ Outstanding reliability, thanks to
ƒƒ constantly clean pump chamber ƒƒ Sealing chamber corrosion-free hydraulics for universal
ƒƒ No generation of fluid-related odours ƒƒ Easy operation thanks to attached applications and various fluids
ƒƒ Easy installation float switch and plug (A version) ƒƒ Easy installation due to its low weight
ƒƒ High operational reliability and threaded flange
ƒƒ Easy operation ƒƒ Quick maintenance facilitated by
direct access to the pump housing
ƒƒ Long maintenance intervals thanks
Technical data ƒƒ Mains connection: 1~230 V, 50 Hz ƒƒ Mains connection: 1~230 V or 3~400 V ƒƒ Mains connection: 1~230 V or 3~400 V
ƒƒ Protection class IP 68 ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1
ƒƒ Max. immersion depth TM/TMW/TMR ƒƒ Non-immersed operating mode: S3 ƒƒ Non-immersed operating mode: S2-
= 1 m, TS/TSW = 7 m 25 % 15, S3 10 %
ƒƒ Fluid temperature 3 °C to 35 °C, ƒƒ Protection class: IP 68 ƒƒ Protection class: IP 68
ƒƒ for short periods up to 3 min. ƒƒ Immersion depth: 5 m ƒƒ Immersion depth: 7 m
ƒƒ max. 90 °C ƒƒ Fluid temperature: max. 35 °C ƒƒ Fluid temperature: max. 40 °C
Equipment/function ƒƒ Motor monitoring via temperature ƒƒ Ready-to-plug versions also with float ƒƒ Single-phase variant with internal
ƒƒ Sheath flow cooling switch capacitor
ƒƒ Hose connection ƒƒ Thermal motor monitoring ƒƒ A-model with plug and float switch
ƒƒ Turbulator (TMW, TSW) ƒƒ Integrated non-return valve ƒƒ VA-model with plug and vertical float
ƒƒ Float switch (depending on type) ƒƒ Hose connection switch
ƒƒ P-model with plug
ƒƒ Thermal motor monitoring
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
54 Drainage and sewage
1H[RV
,QWHOOLJHQFH
Smart solution:
This product is connectable
NEW to pressure drainage systems
with Nexos Intelligence.
Product range Submersible drainage pumps Submersible drainage pumps Submersible sewage pumps
Field of application Dewatering/flood control, industrial Dewatering/flood control, industrial Wastewater collection and transport
process process
Special features ƒƒ Long service life ƒƒ High reliability in abrasive media ƒƒ Low-weight version with stainless
ƒƒ Sturdy construction thanks to rubber-coated hydraulics steel motor
ƒƒ Slurping operation possible and impeller made of hardened chrome ƒƒ Sturdy version in cast iron
ƒƒ Suitable for continuous duty (S1) steel ƒƒ Sealing with two mechanical seals
ƒƒ Ready-to-plug ƒƒ Easy installation thanks to low weight ƒƒ Longitudinal watertight cable inlet
and flexible pressure connection (ver-
tical/horizontal)
ƒƒ Active cooling for reliable continuous
duty, particularly in slurping operation
ƒƒ Easy maintenance thanks to quick
access to wearing parts
ƒƒ Equipped with energy-efficient IE3
motor technology as standard
Technical data ƒƒ Mains connection: 1~230 V or 3~400 V ƒƒ Mains connection: 1~230 V or 3~400 V ƒƒ Mains connection: 1~230 V or 3~400 V
ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1
ƒƒ Non-immersed operating mode: S1 ƒƒ Non-immersed operating mode: S1 ƒƒ Non-immersed operating mode: S2
ƒƒ Fluid temperature: max. 40 °C ƒƒ Fluid temperature: max. 40 °C or S3
ƒƒ Protection class: IP 68 ƒƒ Protection class: IP 68 ƒƒ Protection class: IP 68
ƒƒ Immersion depth: 20 m ƒƒ Immersion depth: 20 m ƒƒ Fluid temperature: max. 40 °C
ƒƒ Immersion depth: 7 or 20 m
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
55
Product range Submersible sewage pumps Submersible sewage pumps Submersible sewage pumps
Field of application Wastewater collection and transport, Wastewater collection and transport, Wastewater collection and transport,
dewatering/flood control dewatering/flood control dewatering/flood control
Special features ƒƒ Heavy-duty hydraulic housing made ƒƒ Connection cable detachable ƒƒ High reliability due to corrosion-free
of cast iron ƒƒ Stainless steel surface-cooled motor hydraulics for universal applications
ƒƒ Easy operation due to the attached ƒƒ Attached float switch (A-model) ena- and various fluids
float switch bles easy operation ƒƒ Easy installation thanks to low weight
ƒƒ Integrated stainless steel pump sup- ƒƒ Integrated pump support foot for easy of composite, integrated capacitor in
port foot for easy installation installation single-phase motor and integrated
ƒƒ Free ball passage: 40 mm ƒƒ Free ball passage: 40 mm fixations in flanges
ƒƒ No switchgear required for thermal ƒƒ Quick maintenance by direct access to
Technical data ƒƒ Mains connection: 1~230 V ƒƒ Mains connection: 1~230 V or 3~400 V ƒƒ Mains connection: 1~230 V or 3~400 V
ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1
ƒƒ Non-immersed operating mode: S3 ƒƒ Non-immersed operating mode: S3 ƒƒ Non-immersed operating mode: S2-
25 % 25 % 15 min, S3 10 %
ƒƒ Protection class: IP 68 ƒƒ Protection class: IP 68 ƒƒ Protection class: IP 68
ƒƒ Fluid temperature: max. 40 °C ƒƒ Fluid temperature: max. 35 °C ƒƒ Fluid temperature: max. 40 °C
ƒƒ Max. immersion depth: 2 m ƒƒ Max. immersion depth: 7 m ƒƒ Max. immersion depth: 7 m
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
56 Drainage and sewage
Product range Submersible sewage pumps Submersible sewage pumps Sewage pumps
Field of application Wastewater collection and transport, de- Wastewater collection and transport, Wastewater collection and transport,
watering/flood control, industrial process wastewater treatment, dewatering/flood wastewater treatment, dewatering/flood
control control
Special features ƒƒ Self-cooling motor for the use in wet ƒƒ Low-weight version with stainless ƒƒ High reliability due to oil-filled sealing
well and dry well installations steel motor or sturdy version in cast chamber and additional leakage
ƒƒ Corrosion-resistant stainless steel iron chamber
motor housing in 1.4404 ƒƒ Also with IE3 motor technology ƒƒ Easy impeller replacement due to
ƒƒ Patented non-clogging hydraulics ƒƒ (on the basis of IEC 60034-30) “back pull-out” design. This means
ƒƒ Longitudinal watertight cable inlet the motor and the impeller can be
ƒƒ Low weight removed without needing to dismantle
the hydraulics
ƒƒ Closed bearing bracket design. This
means that no oil needs to be drained
during dismantling
Technical data ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 1~230 V or 3~400 V ƒƒ Mains connection: 3~400 V
ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1 ƒƒ Operating mode: S1
ƒƒ Non-immersed operating mode: S1 ƒƒ Non-immersed operating mode: S1, S2 ƒƒ Protection class: IP 55
ƒƒ Protection class: IP 68 or S3 (depending from motor type) ƒƒ Fluid temperature: max. 70 °C
ƒƒ Fluid temperature: max. 40 °C ƒƒ Protection class: IP 68 ƒƒ Ambient temperature: max. 40 °C
ƒƒ Max. immersion depth: 20 m ƒƒ Fluid temperature: max. 40 °C ƒƒ Motor efficiency class: IE3, IE4
ƒƒ Max. immersion depth: 7 or 20 m
Equipment/function ƒƒ Thermal motor monitoring ƒƒ Thermal motor monitoring ƒƒ Optional external sealing chamber
ƒƒ Motor chamber monitoring ƒƒ Motor chamber monitoring (Rexa PRO) monitoring
ƒƒ ATEX approval ƒƒ Sealing chamber with optional external
ƒƒ Sheath flow cooling monitoring
ƒƒ ATEX approval (Rexa PRO)
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
57
Product range Sewage pumps Submersible sewage pumps Submersible sewage pumps
Field of application Wastewater collection and transport, Wastewater collection and transport, Wastewater collection and transport,
wastewater treatment, dewatering/flood wastewater treatment, dewatering/flood wastewater treatment, dewatering/flood
control, industrial process control control, industrial process
+P
8JMP3FYB/PSN3& :LOR(08)$
36 48 )$)$
32 69$
28 40 40
24 32 20
20
24 10
16
12 16
8
4 8
0 0 1
0 200 400 600 800 1000 1200 2NåI 0 50 100 150 200 250 300 4PåK 1 10 100 500 4OV
Design Non submersible sewage pump with Submersible sewage pump Submersible sewage pump
standard motor, fully mounted on
baseplate
Special features ƒƒ Easy impeller replacement due to ƒƒ Operationally reliable thanks to Vortex ƒƒ Self-cooling motors for the use in wet
“back pull-out” design and spacer hydraulics and single-channel hydrau- well and dry well installation
coupling as standard. This makes lics with large, free ball passage ƒƒ Process security thanks to extensive
it possible to uninstall the impeller ƒƒ Process reliability thanks to optional monitoring devices
without dismantling the hydraulics monitoring for the sealing chamber ƒƒ Special versions for abrasive and
from the pipeline and the motor from corrosive fluids
the baseplate ƒƒ Low vibrations and long service life
ƒƒ Shut “Back pull-out” unit: Dismantling thanks to high-quality components
Technical data ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 3~400 V
ƒƒ Operating mode: S1 ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1
ƒƒ Protection class: IP 55 ƒƒ Non-immersed operating mode: S2- ƒƒ Non-immersed operating mode: S1
ƒƒ Fluid temperature: max. 70 °C 15 or S2-30 with self-cooling motor, S2 with sur-
ƒƒ Ambient temperature: max. 40 °C ƒƒ Protection class: IP 68 face-cooled motors
ƒƒ Motor efficiency class: IE3, IE4 ƒƒ Fluid temperature: max. 40 °C ƒƒ Protection class: IP 68
ƒƒ Max. immersion depth: 20 m ƒƒ Fluid temperature: max. 40 °C
ƒƒ Max. immersion depth: 20 m
Equipment/function ƒƒ Optional thermal motor monitoring ƒƒ Optional external sealing chamber ƒƒ Heavy-duty version made of cast iron
ƒƒ Optional external sealing chamber monitoring ƒƒ Optional monitoring for motor bearing
monitoring temperature, motor winding tempera-
ture and tightness of motor, terminals
and sealing chamber
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
58 Drainage and sewage
1H[RV
,QWHOOLJHQFH
Smart solution:
Sewage pump
with built-in NEW
Nexos Intelligence.
Product range Submersible sewage pumps Submersible sewage pumps Submersible sewage pumps
Field of application Wastewater collection and transport, Wastewater collection and transport, Wastewater collection and transport,
wastewater treatment, dewatering/flood industrial process wastewater treatment
control, industrial process
+P
+P
Wilo-Rexa SOLID :LOR(08
40 40 )$5) )$:5
50
20
30 40
10
20 30
5
20
10
10
0 1 0
0 20 40 60 80 100 Q/l/s 1 2 3 4 5 10 15 4OV 0 20 40 60 80 100 4OV
Design Submersible sewage pump Submersible sewage pump made of cast Submersible sewage pump with mechan-
stainless steel ical stirring apparatus
Application Pumping of Pumping of highly abrasive sewage Pumping of highly abrasive and fae-
ƒƒ Untreated sewage with faeces and containing faeces (EN 12050-1) without ces-containing sewage (EN 12050-1)
long-fibre components long-fibre components without long-fibre components
ƒƒ Sewage containing faeces ((DIN) EN 12050-1)
ƒƒ Process water, wastewater
Special features ƒƒ Highest operational reliability and ƒƒ Sturdy version completely in stainless ƒƒ Mechanical mixing device made of
reduced service costs, especially for steel casting 1.4581 for the use in Abrasit material to avoid deposits in
pumping untreated sewage thanks to corrosive fluids the pump chamber
the self-cleaning characteristics ƒƒ Longitudinal watertight cable inlet ƒƒ Low vibrations and long service life
ƒƒ Corrosion protection with the optional ƒƒ Low vibrations and long service life thanks to high-quality components
Ceram coating for a long service life in thanks to high-quality components ƒƒ Customised versions are possible
aggressive media
ƒƒ Optional Digital Data Interface (DDI)
with integrated vibration monitor, data
logger, web server and digital rating
plate for convenient monitoring and
system integration
ƒƒ Integration of Nexos Intelligence
Technical data ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 3~400 V
ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1
ƒƒ Non-immersed operating mode: S1 ƒƒ Non-immersed operating mode: S2 ƒƒ Non-immersed operating mode: S2
with self-cooling motor, S2 with sur- ƒƒ Protection class: IP 68 ƒƒ Protection class: IP 68
face-cooled motors ƒƒ Fluid temperature: max. 40 °C ƒƒ Fluid temperature: max. 40 °C
ƒƒ Protection class: IP 68 ƒƒ Max. immersion depth: 20 m ƒƒ Max. immersion depth: 20 m
ƒƒ Fluid temperature: max. 40 °C
ƒƒ Max. immersion depth: 20 m
Equipment/function ƒƒ Optional Nexos Intelligence: ƒƒ Optional external sealing chamber ƒƒ Heavy-duty version made of cast iron
--Reduced downtime and service call- monitoring ƒƒ Mechanical stirring apparatus is fas-
outs thanks to automatic detection tened directly to the impeller
and removal of clogging ƒƒ Mixer head made of Abrasit (chilled
-- Lower energy costs due to the integrat- cast iron)
ed automatic control for the optimal ƒƒ Optional external sealing chamber
operating mode of the specific system monitoring
--Convenient control and connectiv-
ity with the local network via the
integrated web server and Ethernet
interface with established protocols
in the pump
--Increased operational reliability in
the event of a failure thanks to the
integrated pump control in multiple
execution
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
59
Product range Submersible sewage pumps Pedestal pumps Sewage lifting unit
Field of application Raw water intake, wastewater treatment, Industrial process Waste water collection and transport
dewatering/flood control
:LOR(08.35 150 8
100 7
6 50 6
5
4 20 4
10 3
2 2
5
1
0 3-24 3-35 3-37
2 0
0 500 1000 1500 2000 4OV 1 5 10 20 30 50 100 200 Q/m³/h 0 1 2 3 4 5 Q/m³/h
Design Axial submersible pump for use in pipe Non-submersible pedestal pump with Sewage lifting unit
chambers standard motor, discharge bend with
axial suction
Special features ƒƒ Installation directly in the pressure ƒƒ Low maintenance ƒƒ Very compact design for the installa-
pipe ƒƒ No shaft sealing tion into a wet cell or under a shower
ƒƒ Angle of propeller blades adjustable ƒƒ Noise-free suction tray (HiDrainlift 3-24)
ƒƒ Process security thanks to extensive ƒƒ Replaceable IEC standard motor ƒƒ Low-noise operation and integrated
monitoring devices ƒƒ Semi-elastic coupling with the VTM active carbon filter for a high user
ƒƒ Low vibrations and long service life version comfort
thanks to high-quality components ƒƒ Installation in tanks, vessels, rainwater ƒƒ Reliable performance and low power
ƒƒ Customised versions are possible storage tanks and chambers consumption for an efficient wastewa-
Technical data ƒƒ Mains connection: 3~400 V ƒƒ Permitted temperature range up to ƒƒ Mains connection: 1~230 V
ƒƒ Immersed operating mode: S1 120 °C ƒƒ Operation mode: S3
ƒƒ Protection class: IP 68 ƒƒ Nominal-Ø on pressure side DN 32 to ƒƒ Fluid temperature: 35 °C, up to
ƒƒ Fluid temperature: max. 40 °C DN 100 60/75 °C for short periods (5 min)
ƒƒ Max. immersion depth: 20 m ƒƒ Max. operating pressure PN 16 ƒƒ Pressure port: Ø 32 mm
ƒƒ Mains connection 3~400 V, 50 Hz ƒƒ Inlet connection: Ø 40 mm
ƒƒ Max. viscosity 150 cSt ƒƒ Tank volume: 3.9 l; 16 l; 15.5 l
ƒƒ Switching Volume: 0.7 l; 2 l; 2 l
Equipment/function ƒƒ Heavy-duty version made of cast iron ƒƒ Connection on pressure side above or ƒƒ Ready-to-plug (except HiDrainlift
optionally also below the connection 3-24)
plate ƒƒ Thermal motor monitoring
ƒƒ Flange version in PN 10/16/25 ƒƒ Level control with pneumatic pressure
ƒƒ Basic versions VCS: adjustable base- transducer
plate/fixed coupling ƒƒ Integrated non-return valves
ƒƒ Basic version VEM: cast iron support/ ƒƒ Active carbon filter
fixed coupling
ƒƒ Basic version VTM: bearing block/
semi-elastic coupling
ƒƒ Optional: explosion-proof float switch
ƒƒ Optional: external lubrication of
bearing or lubrication provided by fluid
(default)
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
60 Drainage and sewage
Product range Sewage lifting unit Sewage lifting unit Sewage lifting unit
Field of application Wastewater collection and transport Waste water collection and transport Wastewater collection and transport
Application Pumping of pre-cleaned sewage without Pumping of sewage containing faeces Pumping of sewage containing faeces
faeces (DIN EN 12050-2) that cannot be (DIN EN 12050-1) that cannot be piped (DIN EN 12050-1) that cannot be re-
piped to the sewer system through the to the sewer system through the use of turned to the sewer system using natural
use of natural falls natural falls falls, and backflow resistant drainage of
discharge points below the backflow level
Special features ƒƒ Easy to install due to integrated pump ƒƒ HiSewlift 3-I35 in particularly narrow ƒƒ Space-saving installation
and non-return valve design (< 149 mm width) for an easy ƒƒ Installation-friendly due to low weight
ƒƒ Large tank volume front-wall installation and large scope of delivery incl.
ƒƒ Easy maintenance ƒƒ Low-noise operation and integrated non-return valve
ƒƒ Pumps with pressure pipe removable active carbon filter for a high user ƒƒ Flexible thanks to freely selectable
ƒƒ Stainless steel tile frame with trap comfort inlets
ƒƒ Reliable performance and low power ƒƒ Operational reliability thanks to inte-
consumption for an efficient sewage grated thermal motor protection and
disposal mains-independent alarm for SSM and
ƒƒ Easy installation with flexible connec- high water
tion possibilities
ƒƒ Ready for connection
Technical data ƒƒ Mains connection: 1~230 V ƒƒ Mains connection: 1~230 V ƒƒ Mains connection: 1~230 V or 3~400 V
ƒƒ Operation mode: S3 ƒƒ Operation mode: S3 ƒƒ Operation mode: S3
ƒƒ Fluid temperature: max. 35/40 °C ƒƒ Fluid temperature: max. 35 °C ƒƒ Pressure port: DN80
ƒƒ Pressure port: Ø 40 mm ƒƒ Pressure port: Ø 32 mm ƒƒ Inlet connection: DN100, DN40
ƒƒ Inlet connection: DN100 ƒƒ Inlet connection: Ø 40 mm ƒƒ Fluid temperature: max. 40 °C
ƒƒ Gross volume: 113 l ƒƒ Gross volume: 14.4 l; 17.4 l ƒƒ Gross volume: 45 l
ƒƒ Switching volume: 22…31 l ƒƒ Switching Volume: 1 l ƒƒ Switching volume: 21 l
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
61
Product range Sewage lifting unit Sewage lifting unit Sewage lifting unit
Field of application Wastewater collection and transport Wastewater collection and transport Wastewater collection and transport
+P
+P
'UDLQ/LIW0 :LOR'UDLQ/LIW;;/
5H[D/LIW),7/
20 20
16
16 16
12
12 12
8 8 8
4 4 4
0 0 0
0 5 10 15 20 25 30 35 4PåK 0 5 10 15 20 25 30 35 4PåK 0 20 40 60 80 100 120 4PåK
Design Sewage lifting unit Sewage lifting unit Sewage lifting unit
Single and double-pump system Double-pump system Double-pump system
Application Pumping of sewage containing faeces Pumping of sewage containing faeces Pumping of sewage containing faeces
(DIN EN 12050-1) that cannot be re- (DIN EN 12050-1) that cannot be re- (DIN EN 12050-1) that cannot be re-
turned to the sewer system using natural turned to the sewer system using natural turned to the sewer system using natural
falls falls falls
Special features ƒƒ Low system weight for an easy instal- ƒƒ Flexible thanks to height-adjustable ƒƒ Flexible use thanks to one or two tanks
lation and swivel-mounted inlet connection ƒƒ Optimum tank drainage with deep
ƒƒ Integrated non-return valve ƒƒ Easy operation with menu-guided suction function
ƒƒ Flexible thanks to freely selectable switchgear ƒƒ Operationally reliable thanks to large
inlets ƒƒ Integrated non-return valve performance range and a reliable level
ƒƒ Operationally reliable thanks to inte- ƒƒ Operationally reliable due to high detection
grated thermal motor protection and switching volume and reliable level ƒƒ Continuous duty (S1) possible due to
mains-independent alarm for SSM and detection the use of self-cooling motors
Technical data ƒƒ Mains connection: 1~230 V or 3~400 V ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 3~400 V
ƒƒ Operation mode: S3 ƒƒ Operating mode: S1 ƒƒ Operating mode: S1
ƒƒ Fluid temperature: max. 40 °C ƒƒ Fluid temperature: max. 40 °C ƒƒ Fluid temperature: max. 40 °C
ƒƒ Pressure port: DN80 ƒƒ Pressure connection: DN80 ƒƒ Pressure port: DN80, DN100
ƒƒ Inlet connection: DN40/50, DN100, ƒƒ Inlet connection: DN100, DN150 ƒƒ Inlet connection: DN100, DN150
DN150 ƒƒ Gross volume: 380 l ƒƒ Gross volume: 400/800 l
ƒƒ Gross volume: 62 to 140 l ƒƒ Switching volume: 260 l ƒƒ Switching volume: 305 ... 630 l
ƒƒ Switching volume: 24 to 50 l
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
62 Drainage and sewage
1H[RV
,QWHOOLJHQFH
Smart solution:
This product is connectable
to pressure drainage systems
with Nexos Intelligence.
Product range Sewage lifting unit Sewage lifting unit Pump chamber
Pump chamber
Field of application Wastewater collection and transport Wastewater collection and transport Wastewater collection and transport
Application Pumping of sewage containing faeces Pumping of sewage containing faeces Pumping of sewage containing faeces
or pre-cleaned sewage that cannot be or pre-cleaned sewage that cannot be or pre-cleaned sewage that cannot be
returned to the sewer system using returned to the sewer system using returned to the sewer system using
natural falls natural falls natural falls
Special features ƒƒ Long service life and corrosion resist- ƒƒ Pressure-tight pump chamber for ƒƒ Universal use thanks to continuous
ance thanks to PE/PUR material floor-mounted or concealed floor pump chamber extension up to 2.75 m
ƒƒ Maintenance-friendly as all parts are installation ƒƒ Anti-buoyant without weights for
accessible from outside ƒƒ Flexible thanks to freely selectable ground water levels up to the surface
ƒƒ High operational reliability thanks to inlets of the ground for maximum operation-
a pre-filtering of solid matter, the ƒƒ Large tank volume al reliability
pumps deliver only the cleaned sewage ƒƒ Including pipework, level control, ƒƒ covers up to load class D 400
ƒƒ Retrofit system for the economic switchgear and pump (basic version) ƒƒ Easy maintenance thanks to surface
reconstruction of old pump stations coupling
ƒƒ Long service life thanks to pump
chamber body made of corrosion-free
polyethylene
Technical data ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 1~230 V or 3~400 V ƒƒ Diameter: 600/800 mm
ƒƒ Max. inlet: 60 m³/h ƒƒ Operating mode: S3 ƒƒ Pressure port: R 1¼, R 1½
ƒƒ Operation mode: S1 ƒƒ Fluid temperature: max. 40 °C ƒƒ Inlet connection: DN100, DN150,
ƒƒ Fluid temperature: max. 40 °C ƒƒ Pressure port: Ø 40/50 mm DN200
ƒƒ Pressure port: DN80, DN100 ƒƒ Inlet connection: DN100, DN150 ƒƒ Tank heights: 1500, 1800, 2250 mm
ƒƒ Inlet connection: DN200 ƒƒ Gross volume: 255/400 l ƒƒ covers: class A15, B125, D400
ƒƒ Gross volume: 440 or 1200 l ƒƒ Switching volume: 90/130 l ƒƒ Telescopic chamber extension:
ƒƒ Usable tank volume: 295 or 900 l 500 mm
Equipment/function ƒƒ Sewage lifting unit with solid sapara- ƒƒ Wilo-DrainLift WS 40 Basic including ƒƒ Wilo sewage pumps which can be
tion system sewage pump Drain TC 40 used:
ƒƒ Collection reservoir ƒƒ For Wilo-DrainLift WS 40/50 following --Drain TMW 32
ƒƒ 2x solids separation reservoir sewage pumps can be used: --Drain TS 40
ƒƒ 2x sewage pump --Rexa UNI --Drain TC 40
ƒƒ Complete pipework including inlet and --Rexa CUT --Drain STS 40
pressure connection and non-return --Drain MTC
valve --Rexa CUT
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
63
Series Wilo-DrainLift WS 1100 Wilo-EMU polder pump Wilo-EMU RZP 20 to RZP 80-2
Field of application Wastewater collection and transport Water distribution/boosting, clean water Wastewater treatment
treatment, raw water intake, dewatering,
industrial process
+P
+P
:LOR(085=3
.3.03'3
140
2
120
100 1
80
0,5
60
40 0,2
20
0 0,1
10 20 30 40 50 100 160 4OV 50 100 200 500 1000 4OV
Design Pump chamber with synthetic tank, as Polder pump Submersible mixers with housing unit,
single- or double-pump system directly driven or with single-stage
planetary gear
Application Pumping of sewage containing faeces Potable and process water from tanks or Pumping of Wastewater and sewage
or pre-cleaned sewage that cannot be shallow bodies of water; municipal and with low delivery heads and large volume
returned to the sewer system using industrial water supply; sprinkling and flows
natural falls irrigation Flow generation in water channels
Special features ƒƒ Flexible installation ƒƒ Deep water lowering thanks to ƒƒ Vertical or in-line installation possible
ƒƒ Anti-buoyant self-cooling motors ƒƒ Self-cleaning propeller to avoid
ƒƒ High stability ƒƒ Sturdy construction in cast iron or clogging
bronze ƒƒ Propeller in steel or PUR
ƒƒ Compact construction
ƒƒ Maintenance-friendly, rewindable
motors
ƒƒ Optionally with Ceram CT coating for
Technical data ƒƒ Diameter: 1500 mm ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 3~400 V
ƒƒ Pressure port: Rp1½, Rp2, Rp2½, ƒƒ Fluid temperature: max. 20 °C ƒƒ Immersed operating mode: S1
DN80 ƒƒ Minimum flow across outside shroud: ƒƒ Protection class: IP 68
ƒƒ Inlet connection: DN150 not necessary ƒƒ Fluid temperature: max. 40 °C
ƒƒ Tank height: 1800 mm ƒƒ Max. sand content: 35 g/m3 ƒƒ Max. immersion depth: 20 m
ƒƒ Pump chamber covers: 5 kN/m² (in ƒƒ Immersed operating mode: S1
accordance with DIN EN 124, Group 1) ƒƒ Max. immersion depth: 300 m
Equipment/function ƒƒ Wilo sewage pumps which can be ƒƒ Multistage submersible pump ƒƒ Stationary installation directly on the
used: ƒƒ Semi-axial impellers flow pipe
--Drain TS 40 ƒƒ Hydraulics and motor freely configur- ƒƒ Flexible installation via lowering device
--Rexa UNI able according to power requirements ƒƒ Vertical or in-line installation
--Drain TP 80 ƒƒ Three-phase motor for direct or ƒƒ possible
--Rexa FIT/PRO star-delta start
--Drain MTC ƒƒ Motors rewindable as standard
--Rexa CUT
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
64 Drainage and sewage
NEW
Design Direct driven submersible mixer Submersible mixer with single-stage Submersible mixer with two-stage
planetary gear planetary gear
Application Turbulation of deposits and solids in Use in activated sludge tanks and sludge Energetically optimised mixing and circu-
stormwater retention tank and pump tanks for flow generation, suspension of lation of activated sludge; generation of
sump; destruction of floating sludge solids, homogenisation and prevention of flow rates in circulation channels
layers floating sludge layers
Volume flow Q max. Thrust: 180 - 1,131 N Thrust: 160 - 6620 N Thrust: 390 - 4250 N
Special features ƒƒ Low clogging rate and reliable opera- ƒƒ Secure your processes. The planetary ƒƒ Efficient energy usage. The innovative
tion thanks to optimised hydraulics gear is dimensioned on a large scale blade geometry and energy-efficient
ƒƒ Low-wearing, due to the use of stain- so that the mixing forces are absorbed IE3/IE4 motors ensure the best possi-
less steel precision-cast propellers efficiently. ble specific thrust coefficient. At the
with the lowest cavitation tendency ƒƒ Efficient energy usage. The innovative same time, this reduces your energy
ƒƒ Reduction of the energy and operating blade geometry ensures the best pos- and operating costs.
costs due to the use of IE3 motors for sible specific thrust coefficient. At the ƒƒ Consistently reliable. The low-wear-
the best possible thrust coefficient same time, this reduces your energy ing GFK/PA6 propeller is durable and
and operating costs. scores with its self-cleaning effect.
ƒƒ Reliable operation. Clogging-free ƒƒ Smooth running thanks to the
operation with backward-curved balanced propeller load, even in high
incoming flow edge. thrust ranges and when incoming flow
conditions are unfavourable.
Technical data ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 3~400 V ƒƒ Mains connection: 3~400 V
ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1 ƒƒ Immersed operating mode: S1
ƒƒ Protection class: IP 68 ƒƒ Protection class: IP 68 ƒƒ Protection class: IP 68
ƒƒ Fluid temperature: max. 40 °C ƒƒ Fluid temperature: max. 40 °C ƒƒ Fluid temperature: max. 40 °C
ƒƒ Max. immersion depth: 20 m ƒƒ Max. immersion depth: 20 m ƒƒ Max. immersion depth: 20 m
Equipment/function ƒƒ Stationary installation on wall and floor ƒƒ Stationary installation on walls ƒƒ Installation with stand allows free
ƒƒ Flexible installation through the use ƒƒ Flexible installation via lowering device placement in basin
of lowering device or special pipe ƒƒ Can be swivelled horizontally when ƒƒ Flexible installation
attachment installed with a lowering device ƒƒ Two-stage planetary gear with
ƒƒ Can be swivelled vertically and hori- ƒƒ Installation with stand allows free exchangeable second planetary gear
zontally when installed with a lowering placement in basin speed
device ƒƒ Single-stage planetary gear
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
65
Series extension
NEW
Field of application Wastewater treatment Wastewater treatment, industrial process Sewage treatment
Design Vertical mixer with standard gear motor Solids diffuser Aeration system with panel, tube or disc
diffusers
Application Energetically optimised mixing and circu- Gentle mixing process of biomass parti- For fine-bubble aeration of aqueous me-
lation of activated sludge cles in the pumped fluid dia such as water, wastewater or sludge,
for the purposes of supplying oxygen
Volume flow Q max. Thrust: max. 6000 N Circulation capacity 3300 – 4000 m3/h –
Special features ƒƒ Efficient energy usage. The ener- ƒƒ Careful introduction of the biomass ƒƒ High operational reliability thanks to
gy-efficient IE3/IE4 motors reduce carrier particles into the fluid integrated non-return valve
your energy and operating costs. ƒƒ Higher volume penetration for opti- ƒƒ High system efficiency due to in-
ƒƒ Consistently reliable. The low-wear- mising the cleaning process creased ventilation capacity
ing full-material PUR propeller is ƒƒ Reduced energy costs thanks to an ƒƒ Optimised ventilation process due to
durable and and can be adapted to the improved cleaning performance selection of the appropriate diffuser -
system requirments with an angular ƒƒ Also with IE3 motor technology (on panel, tube or disc diffuser
adjustment. the basis of IEC 60034-30) ƒƒ Optimisation of the ventilation process
Equipment/function ƒƒ Version with float for floating instal- ƒƒ Height-adjustable suction pipe due to ƒƒ Aeration system including pipework
lation lowering device made from PVC or stainless steel
ƒƒ Version with 2 propellers ƒƒ Suction pipe with telescopic extension
ƒƒ Version with Ex-rating
ƒƒ Version with integrated frequency
converter
General Overview – Edition 2018 – 50 Hz – Subject to change without prior notice.
66 Service and support
PRACTICAL
SUPPORT FOR
YOUR DAILY WORK.
ALWAYS AT YOUR SIDE: WILO SERVICES.
We are there for you worldwide, 365 days a year. With over 2,500 technicians, our teams assist you in over 60 countries –
not just to meet your needs and requirements but to exceed them whenever possible. A phone call is all it takes and we’ll
initiate all the necessary steps – quickly, professionally and in direct coordination with you. Our service pledge holds for
the entire life cycle of your Wilo products. Because you can always rely on Wilo.
WILO SE
Nortkirchenstraße 100
D-44263 Dortmund
Germany
T +49 231 4102-0
F +49 231 4102-7363
[email protected]
www.wilo.com