A.C. Hydraulic Power Systems: Monarch Dyna Pack M 450 Mini & M 400 Series
A.C. Hydraulic Power Systems: Monarch Dyna Pack M 450 Mini & M 400 Series
Reference: 500−P−000002−E−00
Issue: 05.2010 1/58
2/58 500−P−000002−E−00/05.2010
Contents Page
1 General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Mission Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Quality Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.4 BucherHydraulicsValueStatement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.5 Prototype Policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.6 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
500−P−000002−E−00/05.2010 3/58
3.16 Model M−4551−C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
3.17 Model M−4252 (Formerly M−452) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
3.18 Model M−4253 (Formerly M−453) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
3.19 Model M−4506 (Replaces M−406) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
3.20 Model M−4505 (Replaces M−405) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
3.21 Model M−4328 (Formerly M−428) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
3.22 Model M−4328−P (Formerly M−428−P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
3.23 Model M−4528 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
3.24 Model M−4266 (Formerly M−466) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
3.25 Model M−4257 (Formerly M−457) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
3.26 Model M−4593−C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
4/58 500−P−000002−E−00/05.2010
1 General information
1.1 Introduction
ATTENTION!
This catalogue illustrates the technical specifications for S Always wear eye protection and protective
Bucher Hydraulic’s A.C. range of Hydraulic Power Units. clothing.
Designed for campactness and durability, millions of A.C.
S Remove jewelry and objects that might conduct
Series systems have been sold worldwide for actuating mo-
electricity while working on power units.
bile, material handling, transport, construction, defense, ac-
cess, machine tool, ergonomic, and other labor saving de- S Hydraulic fluid does pose a fire hazard, can
vices. cause burning or skin irritation if not propely
The Bucher Hydraulic name is synonymous with precise handled.
and cost efficient designs, robust construction and rapid S Fluid under pressure can pierce the skin and
backup service. Only eliminate under the direction oft he enter the bloodstream causing death or serious
Jack Family". Reliable service and Quality Machinery injury.
Since 1856" to around the world. S Devices being operated by the hydraulic sys-
tem should be immobilized so they cannot
1.2 Mission Statement moce and cause injury while being inspected or
repaired.
Bucher Hydraulics designs, manufactures and delivers in-
Disconnect from electrical source.
novative fluid power solutions and provides unparalleled
support for its customers. S Prior to performing any maintenance make sure
the equipment is turned off and that any stored
energy, for example pressure, is released. Also,
1.3 Quality Policy extended equipment or cylinders should be
Bucher Hydraulics will provide its customers with products lowered and mechanically locked as required.
and services of continually improving quality to the mutual S Bucher Hydraulics is not responsible for misuse
satisfaction of all parties. or misapplication of porduct. If you have any
questions about application, please contact
1.4 BucherHydraulicsValueStatement local dealer.
S Fluids should be contained and disposed of
S Bucher Hydraulics will be honest, moral and ethical.
properly.
S Bucher Hydraulics will accept responsibility for its actions.
S Bucher Hydraulics will treat people with equality.
S Bucher Hydraulics will make a profit.
You have 90 days free use of this product for testing and
evaluation from the date of invoice. At the end of this period
you can (1) extend the testing and evaluation period for an
additional 90 days or (2) purchase the unit as invoiced (and
order more if needed) or (3) return the unit via prepaid trans-
portation for full credit.
There is no risk to you. Just the opportunity to solve your hy-
draulic problem with the performance and quality of Mon-
arch Hydraulics.
500−P−000002−E−00/05.2010 5/58
1.6 Features and Benefits
Standard M−4300 series Features: Options
S Flexible coupling extends pump life, eliminates misalign- S Pressure gauges
ment S Sae ports on most models
S All powdered metal gears S Complete selection of nfpa do3 control valves and auxili-
S Hardcoated pump end plates for unmatched durability in ary valves
demanding environments and severe duty applications S Cross port relief
S Externally adjustable relief valve with lock nut S Pressure reducing
S 1 year limited warranty on system S Single and double flow control
S Monarch’s personal customer service S Direct and pilot operated check
S 24 hour shipment on most parts orders S Sequence
S Over two million power units sold S Counter balance
S Worldwide distributor network S Relief
S Pressure switches
S Water/oil heat exchangers
S Float switches
S Reservoirs
S 56 frame air motor
S Explosion proof, 50 hertz, chemical duty, dual frequency,
metric frame, high torque and special duty electric motors
S Gasoline and diesel engines
S Close coupled motors available on many systems
6/58 500−P−000002−E−00/05.2010
2 How to Use This Product Guide
S Select the Circuit that will satisfy your design objectives (refer to page 4.0). Contact the Monarch Factory or your Distributor
if you require assistance.
S Select the Model that will provide the desired performance (Flow/Pressure) and Valve Activation (Solenoid or Manual) listed
in the Power System Selection Guide (refer to page ??).
S Follow the ˆHow To Order Your M−4XXX Power System˜ provided after each Model description. Only the recommended
combinations are listed for the particular system. Custom configurations are available and should be discussed with the
Monarch Factory or your Distributor.
S The operating and design characteristics for all of the basic components are listed on pages ??−?? of this guide.
Example:
Order Your Hydraulic Power System As Follows:
Select Circuit: Pump/Motor/Reservoir. Page 8.
Select Model: M−4304. Page 8.
Performance Required: 1.0 GPM @ 2000 PSI. Reference Page 9
Select Pump: 12172−270 (51) (1.02 GPM @ 1725 RPM). Page 9
Select Motor: 08747 (1−1/2 HP, 1725 RPM). Page 10
Select Reservoir: 06073, Page 14
Accessories: 12172−270
Model Code: M−4304−08747−06073
Horizontal Mounting
S Nominal Dimensions are shown for all basic components. Dimensions may be found for your particular system by deleting
the component shown on the unit drawing and adding the dimension for the same item you have selected. Note: Motor
dimensions may vary according to the manufacturer and should be confirmed by the Monarch Factory or your Distributor.
S When selecting Motor, choose the HP required or the next highest HP available.
S When selecting a Reservoir, consideration should be given to dissipating heat, separating air from the oil, and settling out
contamination in the oil. The traditional ˆrule of thumb˜ is that the reservoir should be 2−3 times larger than the pump output
per minute. There must always be a reserve of oil in the reservoir when all cylinders are fully extended. Contact the Monarch
Factory or your Distributor for proper reservoir sizing for your application.
S All system wiring should be completed by a certified electrician according to local codes.
500−P−000002−E−00/05.2010 7/58
2.1 M−400 Series Power System Selection Guide
M−4326 12
M−4304 14
M−4509 16
M−4509−C 17
M−4301 18
M−4315
M−458 Mini 20
M−4319 21
M−4519−C 22
M−4303 23
M−4252 35
M−4253 38
M−4506 24
M−4505 25
M−4328−P 42
M−4528 42
M−4257 40
8/58 500−P−000002−E−00/05.2010
2.2 M−400 Series Pump/Motor Performance Data
12637−150(72)* 0.032 1725 0.24 0.20 0.30 0.35 0.50 0.55 0.75
(0.524) 3450 0.48 0.40 0.60 0.70 1.00 1.10 1.50
12637−270(62)* 0.057 1725 0.42 0.20 0.35 0.45 0.60 0.70 0.90
(0.934) 3450 0.85 0.40 0.70 0.90 1.20 1.40 1.80
12172−150(42) 0.077 1725 0.58 0.25 0.45 0.60 0.80 1.00 1.15
(1.26) 3450 1.15 0.50 0.90 1.20 1.60 2.00 2.30
12172−200(43) 0.099 1725 0.74 0.35 0.55 0.80 1.05 1.30 1.50
(1.66) 3450 1.48 0.70 1.10 1.60 2.10 2.60 3.00
12172−250(03) 0.125 1725 0.93 0.45 0.75 1.10 1.40 1.70 2.15
(2.13) 3450 1.87 0.90 1.50 2.20 2.80 3.40** 3.95**
12172−270(51) 0.137 1725 1.02 0.50 0.80 1.15 1.50 2.00 2.25
(2.31) 3450 2.05 1.00 1.60 2.30 3.00 3.60**
12172−380(05) 0.193 1725 1.44 0.60 1.10 1.50 2.00 2.50 3.00
(3.23) 3450 2.88 1.20 2.20 3.00 3.90**
** = Intermittent Service Only. Contact the Monarch Factory or your Distributor for operating limits. The above pumps tested
using Mobil DTE 24 at 100°F 165 SUS, 95 Viscosity. Note: kW = HP x 0.746
* = Denotes i−Pump
500−P−000002−E−00/05.2010 9/58
2.3 M−400 Series Motor Information
Monarch Supplied 56C Motors have the standard length NEMA shaft shortened by 1−3/16". All other frame size motors and
all special ordered units are supplied with NEMA standard length drive shafts when possible. The above motors may be speci-
fied with standard NEMA 56C length drive shafts.
10/58 500−P−000002−E−00/05.2010
2.4 Dimensional Information for Standard M−400 Motors With Flexible Couplings
Motor Number 08751 is a 2 HP, 3450 RPM, 115/230 V AC, 60 Hz, 1 Phase, NEMA 56C TEFC and is shown as a general
reference. Dimensions will vary according to motor output and manufacturer. Contact the Monarch Factory for more informa-
tion.
Monarch standard adapter 01605 requires the NEMA motor shaft be shortened by 1−3/16". Adapter 01615 should be specified
when a standard NEMA motor shaft is required.
2” (51 mm)
5/8” Ø
(16 mm)
8−11/16”
(221 mm)
1−5/8” 6−13/16”
(41 mm) (173 mm)
10−11/16” (271 mm) 8−1/4”
(210 mm)
SIDE VIEW END VIEW
500−P−000002−E−00/05.2010 11/58
2.4.1 Close Coupled Motors For M−400 Units
The following direct drive (partial) motors are supplied with an adapter for mounting the pump base directly to the motor. The
01605 and/or 01615 extended pump/motor adapter and flexible coupling is not required. The close coupled motors may be
used on Models: M−4301, M−4304, M−4315, M−4319, M−4326, M−4328 and M−4328−P
12/58 500−P−000002−E−00/05.2010
2.4.2 Close Coupled Motor for Monarch M−4200 Mini Units
The 08149 110 V AC, PSC 1 Phase, 60 Hz Motor is standard on all Mini Units. The motor includes a thermal overload with
automatic reset. A capacitor is required. The 03862 60 ìF 330V AC Capacitor is available as optional equipment. Note: Other
Voltages, Enclosures, and Capacitors are available.
12637−100(70) 0.021 1800 0.16 7.6 7.7 8.0 8.4 8.9 9.5
(0.34)
12637−120(71) 0.025 1800 0.20 7.6 7.8 8.2 8.8 9.5 9.5
(0.41)
12637−150(72) 0.032 1800 0.25 7.7 7.8 8.6 9.5 9.5 9.5
(0.524)
500−P−000002−E−00/05.2010 13/58
2.5 Reservoirs for M−400 Units
14/58 500−P−000002−E−00/05.2010
Part Number Useable Capacity Length in / (mm)
Horizontal Vertical
Cubic inch (in3) Liter (L) Cubic inch (in3) Liter (L)
500−P−000002−E−00/05.2010 15/58
Horizontal Length in / (mm)
16/58 500−P−000002−E−00/05.2010
2.6 Reservoirs for Mini Units
Useable Capacity
Cubic inch (in3) Liter (L) Cubic inch (in3) Liter (L)
500−P−000002−E−00/05.2010 17/58
Part Number Horizontal Vertical Length in / (mm)
Useable Capacity
Cubic inch (in3) Liter (L) Cubic inch (in3) Liter (L)
* Reservoir should not be used in a horizontal application without first consulting engineering (Special supports may be re-
quired).
18/58 500−P−000002−E−00/05.2010
2.7 Valves for M−400 Series Units
2.7.1 NPFA DO3 Directional and Auxiliary Control Valves.
Solenoid directional and auxiliary controls are typically added to the M−4505, M−428, and M−429. Please refer to the Bucher
Hydraulics Directional Control Valve brochure for additional information and selection.
00970 A B 4−Way/3−Position.
Solenoid Operated.
b P T a Tandem Center. 110VAC
00967 A B 4−Way/3−Position.
Solenoid Operated.
b P T a Open Center. 110VAC
00968 A B 4−Way/3−Position.
Solenoid Operated.
b P T a Closed Center. 110VAC
01041 4−Way/2−Position.
P to A.
b P T Spring Offset. 110VAC
00692 AB 4−Way/2−Position.
P to A.
b P T a Spring Offset. 110VAC
P T B A
Consult your local Monarch distributor or the factory about special requirements for explosion proof, shockless (soft shift) and
other function and spool configurations not shown here. 12 and 24 VDC, 24 VAC and other voltages are available. Functional
symbols related to solenoid identity "A" or "B" according to NFPA/ANSI standards, i.e., energizing solenoid "A" gives flow P
to A, solenoid "B" gives flow P to B (As Applicable).
500−P−000002−E−00/05.2010 19/58
2.7.2 Cartridge Valves
Solenoid operated cartridge valves are used in the M−403, M−419, and M−452 units.
07145 4−Way/2−Position.
Common Cavity #8. 110VAC.
Conduit Connector.
Consult Factory about many additional valve voltages, coil terminations and other options.
00948 A B 4−Way/3−Position.
Closed Center.
P T Manually Operated.
00949 A B 4−Way/3−Position.
Open Center.
P T Manually Operated.
00806 A B 4−Way/3−Position.
Tandem Center.
P T
Manually Operated.
00957 A B 4−Way/3−Position.
Tandem Center.
P T NFPA DO3.
20/58 500−P−000002−E−00/05.2010
2.8 M−400 Series Accessories
01875 Filter Only, Return Line. 15 GPM. 10 Micron Nominal, includes filterhead.
S Air Motors
S Heat Exchangers
S Temperature Switches
S Pressure Switches
S Motor Controls
S Multi−Function Valve Controls − Monoblock and Sectional
Consult Factory about many additional valve voltages, coil terminations and other options.
500−P−000002−E−00/05.2010 21/58
2.9 Monarch Hand Pumps
Standard − Standard Displacement (0.50 In3/Stroke) High Pressure − Low Displacement (0.25 In3/Stroke) High Pressure/
Heavy Duty − Standard Displacement (0.50 In3/Stroke)
Note: It is recommended that pins and piston be periodically lubricated to prolong hand pump life.
Description Schematic
S 0.50 In3/Stroke (8.20 Cm3/Stroke)
S Single Acting
S 2000 PSI (138 Bar)
S Outlet Port: 1/4" NPTF
S Ideal For Emergency Back−Up Application in Case of
Primary Pump Failure
S Horizontal or Vertical Mounting
S Designed for Mounting Directly to Monarch Power Units
S Handle May Positioned in any Direction
S Release Valve (Use Handle for Actuating)
S Supplied with Painted Steel "Comfort Grip" Handle
S All Exposed Materials are Aluminum or Plated Steel for
Corrosion Resistance
Popular Options
S Remote Mounting
S Ports. Other Styles Available
S Relief Valve
S Integral Reservoir
22/58 500−P−000002−E−00/05.2010
2.11 High Pressure − Low Displacement Hand Pump
Description Schematic
S 0.25 In3/Stroke (4.10 Cm3/Stroke)
S Single Acting
S 3500 PSI (240 Bar)
S Outlet Port: 1/4" NPTF
S Ideal For Emergency Back−Up Application in Case of
Primary Pump Failure
S Horizontal or Vertical Mounting
S Designed for Mounting Directly to Monarch Power Units
S Handle May Positioned in any Direction
S Release Valve (Use Handle for Actuating)
S Supplied with Painted Steel "Comfort Grip" Handle
S All Exposed Materials are Aluminum or Plated Steel for
Corrosion Resistance
Popular Options
S Remote Mounting
S Ports. Other Styles Available
S Relief Valve
500−P−000002−E−00/05.2010 23/58
2.12 High Pressure − Heavy Duty Hand Pump
Description Schematic
S 0.50 In3/Stroke (8.20 Cm3/Stroke)
S Single Acting
S 4000 PSI (275 Bar)
S Outlet Port: 1/4" NPTF
S Heavy Duty Plated Steel Tension Link and Extruded
Aluminum Top and Bottom Brackets
S Ideal For Emergency Back−Up Application in Case of
Primary Pump Failure
S Horizontal or Vertical Mounting
S Designed for Mounting Directly to Monarch Power Units
S Handle May Positioned in any Direction
S Release Valve (Use Handle for Actuating)
S Supplied with Painted Steel "Comfort Grip" Handle
S All Exposed Materials are Aluminum or Plated Steel for
Corrosion Resistance
Popular Options
S Remote Mounting
S 1/4" NPTF Ports. Other Styles Available
S Relief Valve
24/58 500−P−000002−E−00/05.2010
2.13 Heavy Duty Remote Hand Pump
500−P−000002−E−00/05.2010 25/58
3 Monarch A.C. Hydraulic Power Systems
3.1 Model M−4226 Mini System (Formerly M−455)
Description Schematic
S Pump Motor Unit
S Check Valve
S Externally Adjustable Relief Valve
S .375 Inch NPT Suction M
26/58 500−P−000002−E−00/05.2010
3.2 Model M−4326 (Formerly M−426)
Description Schematic
S Pump Motor Unit OUTLET PORT
3/8 NPTF
S Check Valve
S Externally Adjustable Relief Valve
S .375 Inch NPT Suction
S .375 Inch NPT Outlet
S .125 Inch NPT Relief Valve Return Port
500−P−000002−E−00/05.2010 27/58
3.3 Model M−4204 Mini System (Formerly M−454)
Description Schematic
S Pump/Motor/Reservoir/Unit
S Externally Adjustable Relief Valve
S 7/16−20 SAE O−Ring Outlet Port, 3/8" NPT Return
S Horizontal Mounting Standard M
S Vertical Mounting/Motor Up
Ref. Page 9 Ref. Page 10 Ref. Page 13 Ref. Page17 Ref. Page 21
28/58 500−P−000002−E−00/05.2010
3.4 Model M−4304 (Formerly M−404)
Description Schematic
S Pump/Motor/Reservoir/Unit OUTLET PORT
3/8 NPT
S Check Valve
S Externally Adjustable Relief Valve
S .375 Inch NPT Outlet and Return
S Horizontal Mounting Standard
S Vertical Mounting/Motor Up M
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 13 Ref. Page 21
500−P−000002−E−00/05.2010 29/58
3.5 Model M−4313 (Formerly M−413)
Description Schematic
S Pump/Motor/Reservoir/Unit OUTLET PORT
3/8 NPTF
S Manually Operated 2−Way/2−Position
Normally Closed Valve
S Externally Adjustable Relief Valve
S .375 Inch NPT Outlet and Return
S Horizontal Mounting Standard
S Vertical Mounting/Motor Up
M
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 21
30/58 500−P−000002−E−00/05.2010
3.6 Model M−4509
Description Schematic
S Pump/Motor/Reservoir/Valve Unit Outlet Port
#6 SAE (9/16−18)
S 3−Way Manually Operated Valve
S Externally Adjustable Relief Valve
S .#6 SAE
S Vertical Mounting Standard (Motor Up)
S Snap Action Push Button Start Switch
in Motor L1
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 21
500−P−000002−E−00/05.2010 31/58
3.7 Model M−4509−C
Description Schematic
S Pump/Motor/Reservoir/Valve Unit Outlet Port
#6 SAE (9/16−18)
S Check Valve
S Externally Adjustable Relief Valve
S Manually Operated Lowering Valve
S Pressure Compensated Flow Control
S #6 SAE Outlet
L1
S Vertical Mounting Standard, Motor Up
M
Popular Features L2
S Horizontal Mounting
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 21
32/58 500−P−000002−E−00/05.2010
3.8 Model M−4301 (Formerly M−401)
Description Schematic
S Pump/Motor/Reservoir/Unit OUTLET PORT
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 13 Ref. Page 21
500−P−000002−E−00/05.2010 33/58
3.9 Model M−4315 (Formerly M−415)
Description Schematic
S Pump/Motor/Reservoir/Unit 1/4 NPTF
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 13 Ref. Page 21
34/58 500−P−000002−E−00/05.2010
3.10 Model M−4219 (Formerly M−459)
Description Schematic
S Pump/Motor/Reservoir/Unit
S Check Valve
S Externally Adjustable Relief Valve
S 2−Way/2−Position Normally Closed
Solenoid Operated Lowering Valve
S Outlet Port Options: M
Check Valve Port 7/16−20 SAE O−Ring or
Face Port: 7/16−20 SAE O−Ring
S Horizontal Mounting Standard
S Vertical Mounting (Motor Up) Optional
Ref. Page 9 Ref. Page 10 Ref. Page 13 Ref. Page17 Ref. Page 21
500−P−000002−E−00/05.2010 35/58
3.11 Model M−4219 w/PCFC
Description Schematic
S Pump/Motor/Reservoir/Unit 7/16 SAE OR NPTF
S Check Valve
S Externally Adjustable Relief Valve
S 2−Way/2−Position Normally Closed
Solenoid Operated Lowering Valve
S Cartridge Style Pressure Compensated
Lowering Valve
S Outlet Port Options:
M
Check Valve Port 7/16−20 SAE O−Ring or
Face Port: 7/16−20 SAE O−Ring
S Horizontal Mounting Standard
S Vertical Mounting (Motor Up) Optional
Ref. Page 9 Ref. Page 10 Ref. Page 13 Ref. Page17 Ref. Page 21
36/58 500−P−000002−E−00/05.2010
3.12 Model M−4319 (Formerly M−419)
Description Schematic
S Pump/Motor/Reservoir/Valve Unit OUTLET PORT
3/8 NPTF
S Solenoid Operated 2−Way/2−Position
Normally Closed Valve
S Externally Adjustable Relief Valve
S .375 Inch NPT Outlet
S Horizontal Mounting Standard
S Vertical Mounting (Motor Up) Optional
M
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 13 Ref. Page 21
500−P−000002−E−00/05.2010 37/58
3.13 Model M−4519−C
Description Schematic
S Pump/Motor/Reservoir/Valve Unit
S Check Valve
S Externally Adjustable Relief Valve
S 2 Way/2 Position Normally Closed Cartridge Valve
S #6 SAE Outlet
S Horizontal Mounting Standard M
Popular Features
S Vertical Mounting/Motor Up
S Pressure Compensated Cartridge Style On HYDRAULIC SCHEMATIC
Lowering Circuit
S Manual Override
Ref. Page 9 Ref. Page 11 Ref. Page 10 Ref. Page 13 Ref. Page 21
38/58 500−P−000002−E−00/05.2010
3.14 Model M−4303 (Formerly M−403)
Description Schematic
S Pump/Motor/Reservoir/Valve Unit OUTLET PORT
3/8 NPT
S Solenoid Operated 2−Way/2−Position Normally Closed
Valve and Solenoid Operated 2−Way/2−Position Normally
Open Valve
S Externally Adjustable Relief Valve
S .375 Inch NPT Outlet
S Horizontal Mounting Standard
S Vertical Mounting (Motor Up) Optional
M
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 21
500−P−000002−E−00/05.2010 39/58
3.15 Model M−4310 (Formerly M−410)
Description Schematic
S Pump/Motor/Reservoir/Valve Unit OUTLET PORTS
1/4 NPT
S 4−Way Manually Operated Valve ”A” ”B”
S Externally Adjustable Relief Valve
S .250 Inch NPT Outlets
S Horizontal Mounting Standard
S Vertical Mounting (Motor Up) Optional
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 13 Ref. Page19 Ref. Page 21
40/58 500−P−000002−E−00/05.2010
3.16 Model M−4551−C
Description Schematic
S Pump/Motor/Reservoir/Valve Unit C2 C1
S Check Valve
S Externally Adjustable Relief Valve
S (1) 4 Way/2 Position and (1) 2 Way/2 Position Normally
1800 PSI
Closed Solenoid Cartridge Valve Located in the Base
S C1 Port Positively Checked
S Externally Adjustable Relief Valve in C2 Port
S #6 SAE Outlets
S Horizontal Mounting Standard 1200 PS I
M
Popular Features
S Pressure Compensated Cartridge Style Flow Control
S Vertical Mounting, Motor Up
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 13 Ref. Page 21
500−P−000002−E−00/05.2010 41/58
3.17 Model M−4252 (Formerly M−452)
Description Schematic
S Pump/Motor/Reservoir/Unit C1 C2
S Check Valve
S 4−Way/2−Position Solenoid Cartridge Valve Mounts
Directly to Unit
S 7/16−20 SAE O−Ring Outlet
S Horizontal Mounting Standard
S Vertical Mounting (Motor Up) Optional
Ref. Page 9 Ref. Page 10 Ref. Page 13 Ref. Page17 Ref. Page 21
42/58 500−P−000002−E−00/05.2010
3.18 Model M−4253 (Formerly M−453)
Description Schematic
S Pump/Motor/Reservoir/Unit OUTLET PORTS
1/4 NPT
S 4−Way/3−Position DO3 Solenoid Valve
S 7/16−20 SAE O−Ring Outlet
S Horizontal Mounting Standard
S Vertical Mounting (Motor Up) Optional
Ref. Page 9 Ref. Page 10 Ref. Page 13 Ref. Page17 Ref. Page 21
500−P−000002−E−00/05.2010 43/58
3.19 Model M−4506 (Replaces M−406)
Description Schematic
S Pump/Motor/Reservoir/Unit OUTLET PORTS
1/4 NPT
S NPFA DO3 Valve Mounting Surface
S Externally Adjustable Relief Valve
A B
S .250 Inch NPT Outlets
D03
S Horizontal Mounting Standard
S Vertical Mounting (Motor Up) Optional
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page19 Ref. Page 21
44/58 500−P−000002−E−00/05.2010
3.20 Model M−4505 (Replaces M−405)
Description Schematic
S Pump/Motor/Reservoir/Unit OUTLET PORTS
1/4 NPT
S Externally Adjustable Relief Valve
S 4−Way/3−Position Solenoid Operated DO3 Valve. Stan-
dard Tandem Center Shown. Other Spool Types Avai-
lable.
S .250 Inch NPT Outlets
S Horizontal Mounting Standard
M
S Vertical Mounting (Motor Up) Optional
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page19 Ref. Page 21
500−P−000002−E−00/05.2010 45/58
3.21 Model M−4328 (Formerly M−428)
Description Schematic
S Pump/Motor/Reservoir/Valve Unit
S Externally Adjustable Relief Valve
S Two 4−Way/3−Position Solenoid Operated Tandem
Center DO3 Valves in One Two Station Manifold for
Series Operation
M
S Maximum Relief Valve Setting 1400 PSI
S ..375 Inch NPT Outlets
S Vertical Mounting
Popular Features
S Unit Less D03 Valves
Ref. Page 9 Ref. Page 10 Ref. Page 13 Ref. Page 13 Ref. Page19 Ref. Page 21
46/58 500−P−000002−E−00/05.2010
3.22 Model M−4328−P (Formerly M−428−P)
Description Schematic
S Pump/Motor/Reservoir/Valve Unit
S Externally Adjustable Relief Valve
S Two 4−Way/3−Position Solenoid Operated Tandem
Center DO3 Valves in One Two Station Manifold for Paral-
lel Operation
M
S ..375 Inch NPT Outlets
S Vertical Mounting
Popular Features
S Unit Built with unloading valve
S Unit Less D03 Valves
Ref. Page 9 Ref. Page 10 Ref. Page 13 Ref. Page 13 Ref. Page19 Ref. Page 21
500−P−000002−E−00/05.2010 47/58
3.23 Model M−4528
Description Schematic
S Pump/Motor/Reservoir/Valve Unit
S Check Valve in "P" Port
S Externally Adjustable Relief Valve
S (2) D03 Double Solenoid Valves
S #6 SAE Outlets
S 250 Inch NPT Outlets M
Popular Features
S Vertical Mounting, Motor Up
S Large Selection of D03/CETOP Valves and Accessories
S Parallel Circuit Available
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 13 Ref. Page 21
48/58 500−P−000002−E−00/05.2010
3.24 Model M−4266 (Formerly M−466)
Description
Schematic
S Pump/Motor/Reservoir/Valve Unit
S Cartridge Valve Block Manifolded Directly to Power Unit
S Controls 2 Single Acting Cylinders Independently
S .125 Inch NPT Outlets
S Horizontal Mounting Standard
S Vertical Mounting/Motor Up
Ref. Page 9 Ref. Page 10 Ref. Page 13 Ref. Page17 Ref. Page 21
500−P−000002−E−00/05.2010 49/58
3.25 Model M−4257 (Formerly M−457)
Description
Schematic
S Pump/Motor/Reservoir/Valve Unit
S Independent Operation of Two Single Acting Master/
Slave Cylinder Circuits
MASTER SLAVE
S Cartridge Valve Block Manifolded Directly to Power Unit
S .125 Inch NPT Outlets
MASTER SLAVE
S Horizontal Mounting Standard
S Vertical Mounting/Motor Up
Ref. Page 9 Ref. Page 10 Ref. Page 13 Ref. Page17 Ref. Page 21
50/58 500−P−000002−E−00/05.2010
3.26 Model M−4593−C
Description
Schematic
S Pump/Motor/Reservoir/Valve Unit
C3 C2 C1
S Externally Adjustable Relief Valve
3000 P SI
S Solenoid Cartridge Valves, Pilot Operated
S Check Valves, and Adustable Cross−Over Relief System 3000 PSI
B
Mounted in a Compact Manifold
S Horizontal Mounting Standard
C A D
Popular Features
S Vertical Mounting, Motor Up
M 2500 PSI
Ref. Page 9 Ref. Page 10 Ref. Page 11 Ref. Page 13 Ref. Page 21
500−P−000002−E−00/05.2010 51/58
4 MT & T Series Industrial Power Units
52/58 500−P−000002−E−00/05.2010
4.1 Standard System Side View w/cutaway
Options:
S Water/Oil Heat Exchangers S Custom Systems
S Air/Oil Heat Exchangers S Synthetic Fluids − Consult Factory
S Wide Range of Pressure Gauges S Subplate Mounted D03 and D05 Stack Valves
S Heaters S Cross Port Relief
S Viton Seals S Pressure Reducing
S NPT Ports S Single and Double Flow Control
S Return Filter, 10 Micron Nominal S Directional and Pilot Operated Check
S A Wide Selection of D03 and D05 Directional S Sequence
S Control Valves S Counter Balance Relief
S Pressure Switches
S Float Switches
500−P−000002−E−00/05.2010 53/58
4.2 MT & T Series Pump Performance Data
4.2.1 MT Series
Pump Code IN3/REV RPM GPM 500 HP 1000 HP 1500 HP 2000 HP 2500 HP 3000 HP
12637−150 (72) 0.032 1800 0.25 0.20 0.30 0.35 0.50 0.55 0.75
3600 0.50 0.40 0.60 0.70 1.00 1.10 1.50
12637−270 (62) 0.57 1800 0.45 0.20 0.35 0.56 0.60 0.70 0.90
3600 0.90 0.40 0.70 0.90 1.20 1.40 1.80
12172−150 (42) 0.77 1800 0.60 0.25 0.45 0.60 0.80 1.00 1.15
3600 1.20 0.50 0.90 1.20 1.60 2.00 2.30
12172−200 (43) 0.099 1800 0.80 0.35 0.55 0.80 1.05 1.30 1.50
3600 1.60 0.70 1.10 1.60 2.10 2.60 3.00
12172−250 (03) 0.125 1800 1.00 0.45 0.75 1.10 1.40 1.70 2.15
3600 2.00 0.90 1.50 2.20 2.80
12172−270 (51) 0.137 1800 1.10 0.50 0.80 1.15 1.50 2.00 2.25
3600 2.20 1.00 1.60 2.30 3.00
12172−380 (05) 0.193 1800 1.50 0.60 1.10 1.50 2.00 2.50 3.00
3600 3.00 1.20 2.20 3.00
4.2.2 T Series
Pump Code IN3/REV RPM GPM 500 HP 1000 HP 1500 HP 2000 HP 2500 HP 3000 HP
02913 0.27 1800 2.10 0.85 2.00 2.30 3.00 3.90 4.80
02908 0.37 1800 2.90 1.10 2.10 3.10 4.15 5.15 6.25
02902 0.50 1800 3.90 1.50 2.80 4.00 5.30 6.60 8.10
02909 0.68 1800 5.30 1.90 3.71 5.56 7.42 9.28 11.13
02904 0.84 1800 6.55 2.40 4.60 6.65 8.65 10.65 12.85
02910 0.97 1800 7.60 2.70 5.32 7.90 10.50 13.20 16.00
02911 1.15 1800 9.00 3.15 6.30 9.45 12.62 15.80 18.90
* Pump supplied standard with adjustable maximum displacement stop which can be set between 3.0 GPM and 7.5 GPM.
Maximum speed pump 2000 RPM.
* When selecting motor, choose the HP required or the next HP available.
* Contact the factory for operating T Series pumps at speeds above 1800 RPM.
54/58 500−P−000002−E−00/05.2010
4.3 Standard D03 and D05 Directional Control Valves
Manifolds are available from stock in Parallel and Series
Schematic Pump Code configurations. These manifolds may be combined in mul-
tiples of 2 and 3 to form multi−station valve banks.
A B 4−Way/3−Position.
Solenoid Operated.
b a Tandem Center. Example:
P T
A B 4−Way/3−Position.
Solenoid Operated.
b P T a Open Center.
A B 4−Way/3−Position.
Solenoid Operated.
b P T a Closed Center.
A B 4−Way/3−Position, P
Blocked. A and B to T.
b P T a "Motor Spool".
PARALLEL 2 STATION SERIES 3* STATION
4−Way/2−Position.
P to A. * Back pressure in tank line must not exceed 1000 PSI in
b P T Spring Offset Series configuration with D05 valves or 1500 PSI with D03
valves.
500−P−000002−E−00/05.2010 55/58
Series Pump Reservoir Heat Motor Valve Manifold
Exchanger
56/58 500−P−000002−E−00/05.2010
Relief Valve Directional Control Valves Coil Voltage and Filter Economy Options
Electrical Connec-
tion
500−P−000002−E−00/05.2010 57/58
4.4 Limited 1 Year Warranty
Bucher Hydraulics, Inc. (ˆBucher˜) makes the following warranty to any party who purchases this Bucher Hydraulics, Inc. prod-
uct directly from Bucher Hydraulics, Inc. with the intention of either reselling this Bucher Hydraulics, Inc. product or
incorporating it into or attaching it to some other product (ˆthe purchaser˜).
Bucher Hydraulics, Inc. warrants to the purchaser that this product is free from any substantial defects in materials and work-
manship. If this product proves to be defective in materials or workmanship during the period of this warranty, Bucher Hy-
draulics, Inc. will repair or replace, at it´s option, the defective product free of charge (except for transportation charges as
provided below). The period of this warranty is the (1) year period beginning from the date of shipment of this Bucher Hy-
draulics, Inc. product by Bucher Hydraulics, Inc. to the purchaser.
To obtain warranty service, the purchaser must call Bucher Hydraulics, Inc. to have a return goods authorization number as-
signed to them. The purchaser should then send the product claimed to be defective within the warranty period, transportation
prepaid, to: Bucher Hydraulics, Inc., 1363 Michigan Street N.E., Grand Rapids, MI. 49503, USA. Bucher Hydraulics, Inc. will
then repair or replace, at it´s option, items which it finds to have been defective. Bucher Hydraulics, Inc. will return such repaired
or replacement items to the sender free of charge. Items claimed by the purchaser, but not found by Bucher Hydraulics, Inc.,
to be defective will be returned to the purchaser by a reasonably expeditious means at the purchaser´s expense. This expense
may include labor charges incurred from inspecting the unit.
This warranty does not extend to any failure of this Bucher Hydraulics, Inc. product to perform as warranted hereinabove
which is caused by misuse, abuse or material alteration of this product, or any negligence in connection with the installation,
service, or use of this product by any person other than Bucher Hydraulics, Inc.
Bucher Hydraulics, Inc. hereby expressly disclaims any liability for consequential damages to property other than this Bucher
Hydraulics, Inc. product to perform as warranted hereinabove.
[email protected] www.bucherhydraulics.com
E 2010 by Bucher Hydraulics Inc. 1363 Michigan Street NE
All rights reserved.
Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense.
The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to
continual improvement, we reserve the right to amend the product specifications contained in this catalogue.
Classification: 450
58/58 500−P−000002−E−00/05.2010