Foundation Plan Second Floor Framing Plan Roof Framing Plan: B C D E B C D E B C D E

The document shows a diagram of a building with labeled components. It includes floor plans with labeled walls, beams, and other structural elements on each of the 4 floors. The labels use letters and numbers to identify different parts of the building across the 4 diagrams.

Uploaded by

Kristhel Tabones
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
710 views1 page

Foundation Plan Second Floor Framing Plan Roof Framing Plan: B C D E B C D E B C D E

The document shows a diagram of a building with labeled components. It includes floor plans with labeled walls, beams, and other structural elements on each of the 4 floors. The labels use letters and numbers to identify different parts of the building across the 4 diagrams.

Uploaded by

Kristhel Tabones
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

B C D E B C D E B C D E

HOOP TIES
C1/F1
1 WF
C1/F1
1 1
B2 RB
WF
WF
WF B2 B2 RB
S1
RB

WF WF
C1/F1 WF C1/F1 WF C1/F1 RB
2 2 2
B2 B2 B2 B1 RB

B2
S1 B1 B1 S1 B2 RB RB -
RB

WF T1 T1 T2
B2
WF
S1
3 3 3
WF C1/F1
C1/F1 WF
B1 B1 B1 RB RB

S1 B1 RB
B1 S1 B2
WF S1 RB
PC PC
WF RB RB
CB
WF CB S1
RB
MODERN COUNTRYSIDE
C1/F1 C1/F1
B1
MODEL HOUSE
4 C1/F1 WF
4 CB CB
S1 CB
PC B2 4 RB 2-STOREY HOUSE
S1 S1

CB CB

GRID
±700 150

5
TOP OF ROOF BEAM 5Ø10 REST Ø10c150
VERIFY LEVEL 4 Ø 20 4 Ø 20

400
400
JONATHAN CRUZ

1000
2 Ø16 2 Ø16

FOUNDATION PLAN SECOND FLOOR FRAMING PLAN ROOF FRAMING PLAN


TYPICAL DETAIL ( CB )

250 200
200

F1 350 1200mm 1200mm 16mm 16mm 1.2m 7 - 16mm dia bothways


400

FOUNDATION PLAN
2ND FLR FRAMING PLAN
TRUSS DETAILS
TYPICAL T1 DETAIL
ROOF FRAMING PLAN
TYPICAL T2 DETAIL
RB 200mm 250mm 2-16mm∅ 2-16mm∅ 2-16mm∅ 2-16mm∅ 10mm 1@50, 5@100
REST @ 200
CONTINUOUS
STRUCTURAL DETAILS
REINFORCEMENT SCHEDULES
1@50, 5@100
B-1 200mm 400mm 5-16mm∅ 3-16mm∅ 3-16mm∅ 5-16mm∅ 10mm
REST @ 200
CONTINUOUS

1@50, 5@100
B-2 200mm 400mm 4-16mm∅ 3-16mm∅ 3-16mm∅ 4-16mm∅ 10mm
REST @ 200
CONTINUOUS

200 200
400

400

SCHEDULE OF COLUMNS

STEEL MEMBER SCHEDULES


10MM∅ @ 0.2m O.C10MM∅ @ 0.4m O.C ----- 10MM∅ @ 0.2m O.C
S-01 100 BW BW BW SUSPENDED

10MM∅ @ 0.4m O.C 10MM∅ @ 0.4m O.C M1 - INTERIOR MEMBER (1) 2.0" x 2.0" x 4.5mm Angle Bar
SOG 100 ----- ----- -----
BW BW

S
M2 - EXTERIOR MEMBER (2) 2.0" x 3.0" x 4.5mm Angle Bar

100