Features: XT SERIES Jockey Pump Controllers

The document summarizes Eaton's XT Series jockey pump controllers. It describes the controllers' features such as their modular design, digital display, NEMA enclosures, and combination motor controllers. It also provides technical specifications on the available line voltages and motor horsepower ratings for both across-the-line and wye-delta jockey pump controllers. Dimensions for a standard NEMA 2 enclosure are included.

Uploaded by

Jesus Garduño
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
135 views7 pages

Features: XT SERIES Jockey Pump Controllers

The document summarizes Eaton's XT Series jockey pump controllers. It describes the controllers' features such as their modular design, digital display, NEMA enclosures, and combination motor controllers. It also provides technical specifications on the available line voltages and motor horsepower ratings for both across-the-line and wye-delta jockey pump controllers. Dimensions for a standard NEMA 2 enclosure are included.

Uploaded by

Jesus Garduño
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

XT SERIES Jockey Pump Controllers 1-1

Features
XT Series Jockey Pump Controllers March 2012

XT Power Controls Digital Display

The XT Series of Jockey Pump Controllers Eaton's XTJP and XTJY series of jockey pump
incorporate Eaton’s XT Power Controls which controllers are supplied standard with an 1/8 DIN,
are designed for the global marketplace. The NEMA 4X digital panel meter that displays current
XT controls carry global ratings, are small in pressure and hi and low setpoints on a 4-digit,
size and are available in a wide variety of superbright LED display. Pressure input is
operating voltages. They are easy to install provided by a 4-20mA pressure sensor.
and maintain, due to their modular, plug-in
design.

120V Control Power Transformer NEMA 2 Enclosures

All jockey pump controllers are wired with a Enclosures have an oven baked powder paint
120V control power transformer as standard. finish and are supplied with NEMA 2 rating,
unless otherwise ordered. Available options
include: NEMA 3R, 4, 4X, 12.

Technical Data
Product Description
ACROSS-THE-LINE (Direct On Line) JOCKEY PUMP CONTROLLERS
ACROSS THE LINE
Line Voltage
JOCKEY PUMP CONTROLLERS
200 - 208V 220 - 240V 380 - 415V 440 - 480V 550 - 600V 120V 1 ph 240V 1 ph
The XTJP jockey pump controllers operate
across-the-line. Full voltage is applied to the
motor for starting by the use of a single motor Motor Horsepower
starter. Starting inrush current is approximately
600% of rated full load amperes. 1/3 - 15Hp 1/3 - 40Hp 1/3 - 50Hp 1/3 - 50Hp 1/3 - 50Hp 1/3 - 5Hp 1/3 - 10Hp

WYE-DELTA (Star-Delta)
JOCKEY PUMP CONTROLLERS

When six or twelve-lead delta connected WYE-DELTA (Star-Delta) JOCKEY PUMP CONTROLLERS
jockey pump motors are started wye (star)
connected, approximately 58% of line voltage Line Voltage
is applied to each winding. The motor
develops 33% of full-voltage starting torque 200 - 208V 220 - 240V 380 - 415V 440 - 480V 550 - 600V
and draws 33% of normal locked-rotor current
from the line. After an adjustable time delay
(during which the motor accelerates), it is Motor Horsepower
reconnected for normal operation. 1/3 - 15Hp 1/3 - 40Hp 1/3 - 50Hp 1/3 - 50Hp 1/3 - 50Hp
(0.74 - 11.03KW) (0.74 - 29.42KW) (0.74 - 36.78KW) (0.74 - 36.78KW) (0.74 - 36.78KW)
Product Features
Combination Motor Controllers

All jockey pump controllers are supplied with


EATON combination motor controllers, which
combine the circuit breaker and overload in
one device.

Standards & Certification


The XT Series of Jockey Pump Controllers
meet or exceed the requirements of
Underwriters Laboratories, Underwriters
Laboratories Canada, the Canadian Standards
Association and the New York City Building
Code.

N. Y. C.
APPROVED
Sealed Rotary Handle Mechanism

The rotary handle mechanism can be


padlocked in the OFF position.

For more information visit: www.chfire.com BR05805077K


Jockey Pump Controllers
Dimensions
XTJP Jockey Pump Controllers May 2012

Dimensions
Standard Enclosure - Type NEMA 2 - Jockey Pump Controller
10.75
[273]

16.13 8.00
[410] [203]

Ø 0.27 [Ø7] x4
WALL MTG. HOLES

1
2

3
13.00 16.35
4
[330] [415]

NOTES:
1 - ISOLATION SWITCH
2 - HAND/OFF/AUTO SWITCH PIPING ENTRANCE 8.59
3 - DOOR LATCH 8.08 1/4" NPT - FEMALE [218]
4 - DIGITAL DISPLAY [205]
2.13
[54]
Dimensions in inches and [millimeters] 4.03
[102]

Dimensions in inches and [millimeters].

200 - 208V 220 - 240V 380 - 415V 440 - 480V 550 - 600V
Motor Hp Withstand Motor Hp Withstand Motor Hp Withstand Motor Hp Withstand Motor Hp Withstand
Rating (kA) Rating (kA) Rating (kA) Rating (kA) Rating (kA)
0.33 - 3 65 0.33 - 3 65 0.33 - 5 65 0.33 - 7.5 65 0.33 - 10 18
4 50 4 50 7.5 - 10 18 10 50
5 - 10 18 5 - 10 18 15 - 20 18

120V 1 240V 1 Approx. Weight


Motor Hp Withstand Motor Hp Withstand Lbs (Kg)
Rating (kA) Rating (kA)
NOTES:
0.33 - 0.5 65 0.33 - 2 65 22 1. All enclosures finished in Red.
50 2. Cable Entrance either top or bottom.
0.75 3-5 18 (10) 3. Standard Enclosure type NEMA 2.
1-2 18

N. Y. C.
Pending
APPROVED

MD05805161K/B For more information visit: www.chfire.com


Jockey Pump Controllers
Dimensions
XTJP Jockey Pump Controllers May 2012

Dimensions
Standard Enclosure - Type NEMA 2 - Jockey Pump Controller with Options
16.38
21.76 [416]
[553]
13.00
[330]

Ø 0.27 [Ø7] x4
WALL MTG. HOLES

1
2

3
16.00 21.15
[406] [537]
4

NOTES:
1 - ISOLATION SWITCH
2 - HAND/OFF/AUTO SWITCH PIPING ENTRANCE 8.60
8.08 1/4" NPT - FEMALE
3 - DOOR LATCH [218]
[205]
4 - DIGITAL DISPLAY
2.63
Dimensions in inches and [millimeters] [67] 3.96
[101]

Dimensions in inches and [millimeters].

200 - 208V 220 - 240V 380 - 415V 440 - 480V 550 - 600V
Motor Hp Withstand Motor Hp Withstand Motor Hp Withstand Motor Hp Withstand Motor Hp Withstand
Rating (kA) Rating (kA) Rating (kA) Rating (kA) Rating (kA)
0.33 - 3 65 0.33 - 3 65 0.33 - 5 65 0.33 - 7.5 65 0.33 - 10 18
4 50 4 50 7.5 - 10 18 10 50
5 - 10 18 5 - 10 18 15 - 20 18

120V 1 240V 1 Approx. Weight


Motor Hp Withstand Motor Hp Withstand Lbs (Kg)
Rating (kA) Rating (kA)
NOTES:
0.33 - 0.5 65 0.33 - 2 65 22 1. All enclosures finished in Red.
50 2. Cable Entrance either top or bottom.
0.75 3-5 18 (10) 3. Standard Enclosure type NEMA 2.
1-2 18

N. Y. C.
Pending
APPROVED

MD05805166K/B For more information visit: www.chfire.com


Jockey Pump Controllers
Electrical Wiring Schematic
XTJP Jockey Pump Controllers - 3 Phase May 2012

Electrical Wiring Schematic - 3 Phase

N. Y. C.
APPROVED

ES05805176K/B For more information visit: www.chfire.com


Jockey Pump Controllers
Electrical Wiring Schematic
XTJP Jockey Pump Controllers March 2012

Electrical Wiring - Options

N. Y. C.
APPROVED

ES05805177K For more information visit: www.chfire.com


Jockey Pump Controllers
Part Number / Options Selection Guide
XTJP / XTJY Jockey Pump Controllers March 2012

Part Number / Options Selection Guide


XTJP / XTJY Jockey Pump Controllers

XTJP
XTJY

Horsepower (KW) Options


1/3 (0.25) C1 Extra Contacts "Pump Run"
1/2 (0.373) C2 Extra Contacts "AC Power Failure"
3/4 (0.56) E1 NEMA 3R - Raintight Enclosure
1 (0.75) E2 NEMA 4 - Watertight Enclosure
1.5 (1.1) E3 NEMA 12 - Industrial Dust Tight Enclosure
2 (1.5) E5 NEMA 4X - Stainless Steel Enclosure
3 (2.25) E8 Tropicalization
4 (2.94) E9 NEMA 4X - Painted Steel
5 (3.75) E10 NEMA 4X - 316 Stainless Steel Enclosure
7.5 (5.6) EX Export Crating
10 (7.5) POL "Power-On" Light
15 (11) PRL "Pump Run" Light
20 (15) P7 Low Suction Pressure Switch and Alarm Pilot Light
25 (18.6) P8 Low Suction Shutdown (Requires P7)
30 (22) P10 Pressure Switch (0-500psi) - Sea Water
40 (30) R1 Space Heater (120 / 220V)
50 (37) R2 Space Heater c/w Thermostat
R3 Space Heater c/w Humidistat
Voltage S Sequential Start
A= 200 - 208V 60 HZ T Running Period Timer
B= 220 - 240V 60 HZ Z Elapsed Run Time Meter
C= 380 - 50 / 60 HZ
D= 440 - 480V 60 HZ Languages
E= 550 - 600V 60 HZ L1 English Language *
F= 415 - 50 / 60 HZ L2 French Language *
G1 = 120V Single Phase (XTJP only) L5 Spanish Language *
G2 = 240V Single Phase (XTJP only) L11 Turkish Language *
* Other languages available. Consult factory for details.

N. Y. C.
APPROVED

PA05805027K For more information visit: www.chfire.com


Fire Pump Controllers 1-1
Features

XTJP / XTJY Jockey Pump Controllers

Typical Jockey Pump Controller Specifications


Languages
Approvals The controller shall be available in a variety of languages
The Jockey Pump Controller shall meet the requirements of including, but not limited to:
UL 508 [Underwriters Laboratories (UL)] and approved by English, French, Spanish, Turkish.
[Canadian Standards Association (CSA)] [New York Depart-
ment of Buildings (NYSB). Digital Indication
The controller shall be supplied with a digital display that shall
Starting Type indicate the following: System Pressure, Start Pressure, Stop
The controller shall be Across-the-Line or Wye-Delta (Star Del- Pressure.
ta) type designed for full voltage starting.
The digital display shall be supplied with a solid-state 4-20mA
Ratings pressure sensor. The pressure Start and Stop points shall be
The Controller shall have a minimum withstand rating of 18,000 adjustable in increments of one (1) PSI.
symmetrical amperes @ [208V] [240V] [380V] [415V] [480V]
[600V] [120V Single Phase] [240V Single Phase]. The digital display shall be a door-mount type that permits
exterior programming with the controller door secured.
The horsepower rating of the controller shall not exceed 50Hp
for three (3) phase units or 10Hp on single phase units. Options
The jockey pump controller shall have provision to be supplied
Construction with the following options:
The controller shall include a combination Circuit
Breaker / Overload Motor Protector. C1 Extra Contacts “ Pump Run”
C2 Extra Contacts “AC Power Failure”
The circuit breaker shall be mechanically interlocked such that E1 NEMA 3R – Raintight Enclosure
the enclosure door cannot be opened when the handle is in the E2 NEMA 4 – Watertight Enclosure
on position except by a tool operated defeater mechanism. E3 NEMA 12 – Industrial Dust Tight Enclosure
E5 NEMA 4X – Stainless Steel Enclosure
The controller manufacturer shall manufacture the contactor, E8 Tropicalization
circuit breaker, pushbuttons, and enclosures. Brand-labeled E9 NEMA 4X - Painted Steel
components will not be accepted. E10 NEMA 4X - 316 Stainless Steel Enclosure
EX Export Crating
Supply Voltage POL “Power On” Light
The jockey pump controller shall be available with the following PRL “Pump Run” Light
supply voltages: P7 Low Suction Pressure Switch and Alarm Pilot Light
P8 Low Suction Shutdown (Requires P7)
A 200-208V 60 Hz P10 Pressure Switch (0-500psi) – Sea Water
B 220-240V 60 Hz R1 Space Heater (120 / 220V)
C 380V 50 / 60 Hz R2 Space Heater c/w Thermostat
D 440-480V 60 Hz R3 Space Heater c/w Humidistat
E 550-600V 60 Hz S Sequential Start
F 415V 50 / 60 Hz T Run Period Timer
G1 120V Single Phase Z Elapsed Run Time Meter
G2 240V Single Phase
Manufacturer
Enclosure The controller shall be of the XTJP Across-the-Line or
The controller shall be housed in a NEMA Type 2 (IEC IP11) XTJY Wye Delta (Star-Delta) type as manufactured by
drip-proof, powder baked finish, freestanding enclosure. EATON Corporation.

Optional Enclosures
1. NEMA 3R (IEC IP14) rain-tight enclosure.
2. NEMA 4 (IEC IP66) watertight enclosure.
3. NEMA 4X (IEC IP66) watertight 304 stainless steel
enclosure.
4. NEMA 4X (IEC IP66) watertight 316 stainless steel
enclosure.
5. NEMA 4X (IEC IP66) watertight corrosion resistant
enclosure.
6. NEMA 12 (IEC IP52) dust-tight enclosure.

Run Period Timer


An optional Run Period Timer shall be available.