Fosroc Renderoc Putty constructive solutions
Cement based polymer rich putty for wall and ceiling
Uses Application instructions
To provide a water-resistant, smooth finish levelling Preparation
compound for concrete walls, masonry and brick surfaces.
All surfaces to receive Renderoc Putty should be clean and
free from dust, coatings, curing compounds and other loose
Advantages
debris. Surfaces should be free from blow holes or large
! Suitable for both Internal and external applications voids.
! Water-resistant When used over masonry, hollow blocks or rough surfaces,
apply a 1:3 cement:sand render over the blocks and allow to
! Excellent adhesion to host substrate
cure for at least 3 days prior to application of Renderoc Putty.
! Smooth finish
Mixing
! Low water absorption
Care should be taken to ensure that Renderoc Putty is
! Suitable for leveling prior to the application of oil based or thoroughly mixed. Mix in a suitable size container using an
water based coatings approved spiral paddle attached to a slow speed (400/
500rpm) heavy-duty drill.
Description
Place 4.8 - 5.1 litres of cool, clean drinking quality water in the
Renderoc Putty is a cement based putty containing selected mixing container followed by the powder and mix thoroughly.
polymers to provide a smooth finished surface prior to
Small quantities can be hand mixed by blending 2.5 - 3 parts
application of decorative coatings.
powder to 1 part by volume of cool, clean, drinking water.
It is available in white and grey colours.
Application
Technical support All surfaces to be levelled should first be wetted with water at
least one hour prior to the application of Renderoc Putty. Any
Fosroc offers a comprehensive range of high performance,
area that dries too fast should receive further wetting. As a
high quality construction products. In addition, Fosroc offers
general rule surfaces to receive Renderoc Putty should be
a technical support package to specifiers, end-users and
damp before the application of the levelling compound.
contractors, which includes computer aided design (C.A.D.)
and technical on-site assistance from staff with unrivalled Apply Renderoc Putty on the damp surface using a painter's
experience in the industry. putty knife. Do not use a mason's trowel. Build up the levelling
compound in thin layers, until any irregularities or protrusions
have been completely covered. This may require 2-3 coats.
Allow each coat to dry for 20-30 minutes before the application
of further coats. Final coat should be abraded using a fine
grain sand paper after Renderoc Putty has dried for at least
one hour. Levelled areas may be overcoated with decorative
coatings.
Renderoc Putty
Fosroc Renderoc Putty
Estimating Additional Information
Supply Fosroc manufactures a wide range of complementary
Renderoc Putty : 15 kg bags products which include :
Coverage and Yield ! waterproofing membranes & waterstops
Renderoc Putty : 24m² at 0.5 mm thickness
! joint sealants & filler boards
per 15 kg bag
! cementitious & epoxy grouts
Storage
! specialised flooring materials
If protected from the environment in the original undamaged
Fosroc additionally offers a comprehensive package of
packing the shelf life of Renderoc Putty is 12 months.
products specifically designed for the repair and
refurbishment of damaged concrete. Fosroc’s ‘Systematic
Precautions
Approach’ to concrete repair features the following :
Health and safety
! hand-placed repair mortars
Renderoc Putty contains cement powders, which when mixed
! spray grade repair mortars
or become damp, release alkalis which can be harmful to
the skin. During use, avoid inhalation of dust and contact ! fluid micro-concretes
with skin and eyes. Wear suitable protective clothing, gloves,
! chemically resistant epoxy mortars
eye protection and respiratory protective equipment. The use
of barrier creams provide additional skin protection. In case ! anti-carbonation/anti-chloride protective coatings
of contact with skin, rinse with plenty of clean water, then
! chemical and abrasion resistant coatings
cleanse with soap and water. In case of contact with eyes,
rinse immediately with plenty of clean water and seek medical For further information on any of the above, please consult
advise. If swallowed, seek medical attention immediately - your local Fosroc office - as below.
do not induce vomiting.
* Denotes the trademark of Fosroc International Limited
†
See separate data sheet
Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for
the Supply of Goods and Service. All Fosroc datasheets are updated on a regular basis. It is the user’s responsibility to
obtain the latest version.
Head Office
telephone: (+9714) 2039699 fax: (+9714) 2859649 email: [email protected]
Al Gurg Fosroc LLC
Regional offices
Post Box 657, Dubai Abu Dhabi, Al Gurg Fosroc telephone: 673 1779 fax: 673 1449 email: [email protected]
United Arab Emirates Bahrain, YBA Kanoo telephone: 17738200 fax: 17732828 email: [email protected]
Kuwait, Boodai telephone: 4817618 fax: 4832124 email: [email protected]
www.fosroc.com
Oman, Al Amana telephone: 24815080 fax: 24817554 email: [email protected]
Qatar, Tadmur telephone: 4432365 fax: 4419517 email: [email protected]
UAE/0223/03/C