Functions

L-INX Automation Server BACnet  Modbus


LOYTEC  CEA‑709  M-Bus
LINX‑110, LINX‑111 COMPETENCE PARTNER
KNX  OPC
Datasheet #89022006

The L-INX Automation Servers LINX-110 and LINX-111 are programmable automa-
tion stations. They can host user specific graphical pages and can integrate physi-
L-WEB

cal I/Os through L-IOB I/O Modules via LIOB-FT or LIOB-IP.


The Automation Servers provide connectivity functions to concurrently integrate
CEA-709 (LonMark Systems), Modbus, and M-Bus subsystems. LonMark Systems
can be integrated via IP-852 (Ethernet/‌IP) or TP/‌FT‑10. LINX‑110 Automation
Servers feature an integrated Remote Network Interface (RNI) to access the
TP/‌FT‑10 channel on the device via Ethernet/‌IP. LINX-111 Automation Servers fea-
L-ROC

ture a built-in IP-852 router providing the complete feature set of the correspond-
ing L-IP devices. In addition, the L-INX Automation Servers provide connectivity to
Modbus TCP via Ethernet/‌IP and to Modbus RTU via RS-485. M-Bus device integra-
tion needs an optional interface module.

CEA-709 M-Bus Modbus


OPC The gateway functionality allows data communication between all communica-
XML-DA
tion technologies available on the device. Different technology data points are
L-INX

mapped through Local Connections on the device. The mapping of different tech-
nology data points on distributed devices is supported by Global Connections.
L-INX Automation Servers also support Smart Auto-Connect™ – the automatic
LIOB LIOB generation of connections to substantially reduce engineering efforts and cost.
FT IP Gateway All technology data points are automatically created as OPC XML-DA data points.
L-IOB

The L-INX devices provide fully featured AST™ functionality (Alarming, Scheduling,
and Trending) and can be integrated perfectly into the L-WEB System.
RNI

&
y=f(x)
CEA-709
Gateways

LINX-110 Graphics LINX-111 Graphics


L-VIS

Graphics Graphics
Ethernet / IP Graphics Ethernet / IP Graphics
Web Web
Interface Interface

LIOB Modbus
Alarming
OPC XML-DA LIOB Modbus
Alarming
OPC XML-DA
IP-852 Scheduling E-Mail IP-852 Scheduling E-Mail
TCP Server TCP Server
IP Trending IP Trending
L-DALI

Data Point Abstraction Layer Data Point Abstraction Layer


ROUTER

RNI
y=f(x) y=f(x)
Routers, NIC

LIOB LIOB
>INT >INT

Modbus IEC 61131-3 Modbus IEC 61131-3


Sum Counter Sum Counter
+ +

TP/FT-10 M-Bus >DINT max


>= S1
R
SR
Q1

TP/FT-10 M-Bus >DINT max


>= S1
R
SR
Q1

RTU Program RTU Program


SEL SEL
Incr Incr

FT FT
x x
-1 -1

<= <=
x x
-1 -1

V1.2.8 V1.2.8
Interfaces
Accessories

50 www.loytec.com
Functions
L-INX Automation Server

LINX‑110, LINX‑111
Features

L-WEB
• IEC 61131-3 programmable with L-LOGICAD • Supports TP/‌FT‑10 or IP-852 (Ethernet/‌IP)
• Extension with physical inputs and outputs using • Support of dynamically created or static NVs
L‑IOB I/O Modules (LIOB‑FT or LIOB‑IP852) • Support of user-defined NVs (UNVTs) and
• Alarming, Scheduling, and Trending (AST™) Configuration Properties (SCPTs, UCPTs)
• Event-driven e-mail notification • Remote Network Interface (RNI) with 2
MNI devices (LINX‑110 only)

L-ROC
• Math objects to execute mathematical
operations on data points • Integrated IP‑852 to TP/FT‑10 Router (LINX‑111 only)
• Stores customized graphical pages • M-Bus Master according to EN 13757-3, connection via
• Visualization of customized graphical pages through optional M‑Bus Converter (L‑MBUS20 or L‑MBUS80)
LWEB‑900 (Building Management), LWEB‑803 (Monitoring • Modbus TCP and Modbus RTU (Master or Slave)
and Control), or LWEB‑802 (Web Browser) • Gateway functions including Smart Auto-Connect™

L-INX
• Built-in OPC XML-DA server • Integrated web server for device configuration
• Access to network statistics and monitoring data points
• Compliant with CEA‑709, CEA‑852, and • Configurable via Ethernet/‌IP or TP/FT‑10
ISO/‌IEC 14908 Standard (LonMark System)

Specifications

L-IOB
Dimensions (mm) 107 x 100 x 60 (L x W x H), DIM009
Installation DIN rail mounting following DIN 43880, top hat rail EN 50022
Power supply 12-35 V DC / 12-24 V AC ±10 %, typ. 3 W
Operating conditions 0 °C to 50 °C, 10 – 90 % RH @ 50 °C, non condensing, degree of protection: IP40, IP20 (terminals)

Gateways
Interfaces 1 x Ethernet (100Base-T)
OPC XML‑DA
LIOB‑IP
LonMark IP-852*
Modbus TCP (Master or Slave)
HTTP, FTP
1 x TP/‌FT‑10* (LonMark System) along with terminal LIOB‑FT
1 x LIOB‑FT

L-VIS
1 x Modbus RTU (Master or Slave)
1 x M-Bus (Master EN 13757-3)
1 x RS-232 (EIA-232)
LINX-110: * Either LonMark IP-852 or TP/‌FT‑10
LINX-111: * Router between LonMark IP-852 and TP/‌FT‑10

L-DALI
L‑IOB I/O Modules Up to 8 L‑IOB I/O Modules in any combination of type LIOB‑FT and LIOB‑IP852
Remote Network Interface 1 RNI with 2 MNI devices (LINX‑110 only)
CEA‑709 Router 1 (LINX‑111 only)
Program cycle time Down to 10 ms
Routers, NIC

Programming, Tools L‑LOGICAD software (IEC 61131‑3), L‑INX/L-GATE Configurator


Resource limits
Total number of data points 10 000 Total trended data points 256
OPC XML‑DA data points 500 E-mail templates 100
Network variables (NVs) 1 000 Math objects 100
Alias NVs 1 000 Alarm logs 10
Interfaces

External NVs (polling) 1 000 M-Bus data points 1 000


Address table entries 1 000 (non-ECS mode: 15) Modbus data points 2 000
LonMark Calendars 1 (25 calendar patterns) Connections (Local / Global) 1 000 / 250
LonMark Schedulers 100 Number of L-WEB clients 15 (simultaneously)
Accessories

LonMark Alarm Servers 1 L-IOB I/O Modules 8 (LIOB-FT or LIOB‑IP852)


Trend logs 256 (390 000 entries, ≈ 6 MB)

buildings under control 51


Functions
L-INX Automation Server

LINX‑110, LINX‑111
Order number Product description
LINX‑110 CEA‑709 Automation Server, IEC 61131-3 programmable, built-in Remote Network Interface (RNI)
L-WEB

LINX‑111 CEA‑709 Automation Server, IEC 61131-3 programmable, built-in IP-852 Router
LINX‑START‑M Starter kit: 1 x LINX‑11x/21x, 2 x L‑IOB I/O Module, 1 x LPOW-2415B, and L‑LOGICAD software license
L‑LOGICAD‑USB IEC 61131-3 programming tool, single license, includes USB dongle
LIOB‑150 LIOB‑FT I/O Module: 8 UI, 2 DI, 2 AO, 8 DO (4 x Relay 6 A, 4 x Triac 1 A)
L-ROC

LIOB‑151 LIOB‑FT I/O Module: 8 UI, 12 DI


LIOB‑152 LIOB‑FT I/O Module: 6 UI, 6 AO, 8 DO (8 x Relay 6 A)
LIOB‑153 LIOB‑FT I/O Module: 6 UI, 6 AO, 5 DO (4 x Relay 16 A, 1 x Relay 6 A)
LIOB‑154 LIOB‑FT I/O Module: 7 UI, 4 AO, 7 DO (5 x Relay 6 A, 2 x Triac 1 A), 1 Pressure Sensor
LIOB‑450 LIOB‑IP852 I/O Module: 8 UI, 2 DI, 2 AO, 8 DO (4 x Relay 6 A, 4 x Triac 1 A)
L-INX

LIOB‑451 LIOB‑IP852 I/O Module: 8 UI, 12 DI


LIOB‑452 LIOB‑IP852 I/O Module: 6 UI, 6 AO, 8 DO (8 x Relay 6 A)
LIOB‑453 LIOB‑IP852 I/O Module: 6 UI, 6 AO, 5 DO (4 x Relay 16 A, 1 x Relay 6 A)
LIOB‑454 LIOB‑IP852 I/O Module: 7 UI, 4 AO, 7 DO (5 x Relay 6 A, 2 x Triac 1 A), 1 Pressure Sensor
LPOW-2415B Power supply unit with power connector 24 V DC, 15 W
L-IOB

L‑MBUS20 M-Bus level converter for 20 M-Bus devices


L‑MBUS80 M-Bus level converter for 80 M-Bus devices
Gateways
L-VIS
L-DALI
Routers, NIC
Interfaces
Accessories