FFS-0801 (50Hz) Submersible Turbine Pumps Datasheet
FFS-0801 (50Hz) Submersible Turbine Pumps Datasheet
TURBINE PUMPS
Since hitting the market in 1988, FE PETRO® brand submersible
pumps have developed a reputation as the standard in performance,
quality and dependability with innovative features only available from
Franklin Fueling Systems. It is, and always will be about filling cars
faster. With best-in-class flow rates and backed by a long history of
dependability, FE PETRO® pumps are responsible for delivering fuel to
thousands of customers around the globe, day in and day out.
TECHNICAL ADVANTAGES
Variable Speed Advanced Protection
With faster fill times during peak hours and power savings during Stop corrosion in its tracks. Special powder-coated, e-coated,
non-peak hours, variable speed submersible pumping systems and stainless steel components defend your pump in the tank
allow you to maximize profits with consistent flow rates while and in the sump from accelerated corrosion.
mitigating operating expenses.
Turbine Pump Interface
MagShell®
Remote enhanced pump monitoring and control including
The patented stainless steel MagShell® ,available on 2 Hp and pump-in-water automation, clogged intake escalation, tank
4 Hp pumps, is designed to maximize flow rate capabilities, leveling, and tank priority.
potential throughput, and profits. By expanding the pump motor
shell, the MagShell® increases the area for product flow by 45%. Intake Filter Screen
Biofuel Compatibility Avoid system damage, pumping slowdowns, and reduce filter
FE PETRO® Alcohol-Gas (AG) and Advanced Protection (AP) changes by keeping harmful tank debris, sediment, and
pumps are UL listed with both UL79A (up to 85% Ethanol) and corrosion from entering the pumping system with this factory-
UL79B (up to 20% or 100% Biodiesel). installed option.
Variable Length
The patented telescoping pump shaft lets installers adjust the
length of the pump onsite for the perfect fit.
FEATURE SELECTION
Variable Speed
Fixed Speed
MagShell®
Biofuel Compatibility*
Variable Length
Advanced Protection
3• Manifold
4• Containment Sump
1
PUMP HEAD
5• 4" Riser CLEARANCE
6• Tank Adapter
2
7• Tank Manway
BURY
8• Column Pipe DEPTH
3
9• Variable Length Coupler
270mm
• Pump Motor Assembly (PMA)
10 REF
• End bell
11
(B)
RISER 5
LENGTH
(A) 9
MODEL
LENGTH
EFFECTIVE
TANK TANK INSIDE
DIAMETER DIAMETER
(ETD)
10
11
BOTTOM
CLEARANCE
127mm TYPICAL
Notes:
1. Effective tank diameter (ETD) = Inside tank diameter (to top of 4" bung), including tank manway and/or sump adapter.
2. Model length (A) = ETD plus riser length minus bottom clearance minus 25mm thread engagement.
3. Riser length (B) = Bury depth (to top of tank) minus pump head clearance minus tank manway and/or minus sump adapter.
SPECIFICATIONS
4" Submersible Pump Manifold Components & Key Dimensions
1• Line Test Port, ¼" NPT
2• Leak Detector Port, 2" NPT
3• Syphon Port, ¼" NPT
297mm
4• Tank Port, ¼" NPT 265mm
5• Riser Pipe, 4" NPT 1
RISER/COLUMN PIPE
CENTERLINE
DISCHARGE/LEAK DETECTOR
CENTERLINE
147mm
270mm 262mm
3 2
5
4 HP SUBMERSIBLE
TURBINE PUMPS
With faster fill times during peak hours and power savings during
non-peak hours, FE PETRO® 4 Hp variable speed submersible pumps
deliver maximized profits while mitigating operating expenses.
TECHNICAL ADVANTAGES
OPTIONAL FEATURES
Biofuel Compatibility Turbine Pump Interface
FE PETRO® pumps are UL listed with both UL79A (up to 85% Remote enhanced pump monitoring and control including
Ethanol) and UL79B (up to 20% or 100% Biodiesel). pump-in-water automation, clogged intake escalation, tank
leveling, and tank priority.
Advanced Protection
Intake Filter Screen
Stop corrosion in its tracks. Special powder-coated, e-coated,
and stainless steel components defend your pump in the tank Avoid system damage, pumping slowdowns, and reduce filter
and in the sump from accelerated corrosion. changes by keeping harmful tank debris, sediment, and
corrosion from entering the pumping system with this factory-
installed option.
STANDARD FEATURES
Variable Speed Simple Servicing
With faster fill times during peak hours and power savings during If ever required, the pump can be easily removed from the tank
non-peak hours, variable speed submersible pumping systems by unthreading three bolts. There is no need to disconnect the
allow you to maximize profits with consistent flow rates while syphon system or to remove the leak detector from the system
mitigating operating expenses. to service the STP.
Pump Motor • STP variable speed models are UL listed for fuel mixtures
containing up to 10% ethanol, and 20% MTBE, 20% ETBE or
• 4 Hp, variable speed, two-stage centrifugal type pump motor
17% TAME with gasoline.
with integral, automatic, thermal overload protection.
• IST/ISTAP variable speed models are UL and cUL listed for
• Max. pressure: selectable operating pressure on EcoVFC™
fuel mixtures containing diesel fuel with up to 20% Biodiesel,
between 1.65 bar and 2.90 bar deadhead.
100% Biodiesel, up to 85% ethanol with gasoline, and 20%
• Available with MagShell® which results in 45% increased flow MTBE, 20% ETBE or 17% TAME with gasoline.
area around motor.
• All variable speed models can also be used with diesel fuels,
fuel oils, kerosene, Avgas and jet fuels in a non-gelled
Approvals
pourable state.
• cULus listed.
• All wetted elastomers are made of a high grade, fluorocarbon
• Consult factory for applicable approvals. compound.
45
40
35
Total Head in Meters
30
25
20
15
10
0
0 50 100 150 200 250 300 350 400 450 500
Note: Performance based on pumping gasoline (0.76 specific gravity). Pressure is taken at the manifold discharge
outlet. ISTMVS4 and STPMVS4 turbines can only be powered by a MagVFC with three phase incoming power
ORDERING INFORMATION
4 Hp Submersible Pump Ordering Guide
A typical turbine model designation has up to five components to define the pump being supplied as follows:
XXX YYYYY Z - A - B
XXX = Basic Model Designation
STP = These standard variable speed and variable length models
are capable of up to 10% ethanol with gasoline
IST = These variable speed and variable length models include
alcohol-gasoline compatibility (up to 85% ethanol, up to 20%
Biodiesel, or 100% Biodiesel).
ISTAP = These variable speed and variable length models include
alcohol-gasoline compatibility (up to 85% ethanol, up to 20%
Biodiesel, or 100% Biodiesel) and Advanced Protection with (B)
RISER
powder-coated, e-coated, and stainless steel components. LENGTH
Notes:
1. Remove “M” from model number for non-MagShell® pump motor assembly.
2. All STP models are UL and cUL listed for compatibility with fuel mixtures containing up to 10% ethanol with gasoline, up to 5% Biodiesel with diesel fuels, and 20% MTBE, 20% ETBE or 17% TAME with gasoline.
3. All IST/ISTAP models are compatible with fuel mixtures containing diesel fuel with up to 20% Biodiesel, 100% Biodiesel, up to 85% ethanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with gasoline.
4. All models are supplied with a standard check valve unless factory option “R” or “W” is specified.
5. All above models can only be powered by a MagVFC™. 4 hp models require three-phase incoming power supply, 2 hp models can be supplied with single- or three-phase incoming power.
6. 4" riser pipe, if supplied locally, must be 4½" OD by 3/16" WT tubing.
7. For riser pipe length 787mm to 1524mm, additional charge applies (call Customer Service for lead times).
*Model length (A) defined as the dimension from turbine manifold bottom to pump motor inlet.
TECHNICAL ADVANTAGES
OPTIONAL FEATURES
Variable Speed Turbine Pump Interface
With faster fill times during peak hours and power savings during Remote enhanced pump monitoring and control including
non-peak hours, variable speed submersible pumping systems pump-in-water automation, clogged intake escalation, tank
allow you to maximize profits with consistent flow rates while leveling, and tank priority.
mitigating operating expenses.
Intake Filter Screen
Biofuel Compatibility Avoid system damage, pumping slowdowns, and reduce filter
FE PETRO® pumps are UL listed with both UL79A (up to 85% changes by keeping harmful tank debris, sediment, and
Ethanol) and UL79B (up to 20% or 100% Biodiesel). corrosion from entering the pumping system with this factory-
installed option.
Advanced Protection
Stop corrosion in its tracks. Special powder-coated, e-coated,
and stainless steel components defend your pump in the tank
and in the sump from accelerated corrosion.
STANDARD FEATURES
MagShell® Simple Servicing
The patented stainless steel MagShell is designed to maximize
®
If ever required, the pump can be easily removed from the tank
flow rate capabilities, potential throughput, and profits. By by unthreading three bolts. There is no need to disconnect the
expanding the pump motor shell, the MagShell® increases the syphon system or to remove the leak detector from the system
area for product flow by 45%. to service the STP.
• Available with MagShell™ for 45% increased flow area • 200B models require single-phase, 200-250 VAC, 50 Hz
around motor. incoming power and 200C models require three-phase
380-415 VAC 50 Hz incoming power.
Approvals • 200B models incorporate a starting and running capacitor,
• cULus listed. with internal bleed resistor, rated 440 Volt, 40 microfarad.
• Consult factory for applicable approvals. • SPGC-220 single-phase Guardian™ Series controllers and
STP-CBBS single-phase control boxes are available for 200B
pump control.
• STP-SCIIIC three phase smart controller and STP-CBB3C
three-phase magnetic starter are available for 200C contol.
• Max. motor draw: 200B 10 Amps, 200C 5 Amps.
SPECIFICATIONS
2 Hp Variable Speed Pump Performance Charts (STPMVS2)
50
45
40
35
Total Head in Meters
30
25
20
15
10
0
0 50 100 150 200 250 300 350 400 450 500
Flow in Liters per Minute (LPM)
Performance based on pumping gasoline (0.76 specific gravity). Pressure is taken at the manifold discharge outlet.
MagShell® Variable Speed 2 hp was powered by MagVFC™ with Single-Phase, 50 Hz, 220 Volt incoming supply or Eco
VFC™ with Three-Phase, 50 Hz, 410 Volt incoming power supply.
45
40
35
30
Total Head in Meters
25
20
15
10
0
0 50 100 150 200 250 300 350 400 450 500
Flow in Liters per Minute (LPM)
Performance based on pumping solvent (0.78 specific gravity). Pressure is taken at the manifold discharge outlet. Fixed
Speed 2.00 HP was powered by Single-Phase, 50 Hz, 250 Volt incoming supply.
45
40
35
Total Head in Meters
30
25
20
15
10
0
0 50 100 150 200 250 300 350 400 450 500
Flow in Liters per Minute (LPM)
Performance based on pumping solvent (0.78 specific gravity). Pressure is taken at the manifold discharge outlet. Fixed
Speed 2.00 HP was powered by Three-Phase, 50 Hz, 415 Volt incoming supply.
ORDERING INFORMATION
2 Hp Variable Speed Submersible Pump Ordering Guide
A typical model designation has up to five components to define
the pump being supplied as follows:
XXX YYYYY Z - A - B
XXX = Basic Model Designation
STP = These standard variable speed and variable length models are capable of up to
10% ethanol with gasoline
IST** = These variable speed and variable length models include alcohol-gasoline
compatibility (up to 85% ethanol, up to 20% Biodiesel, or 100% Biodiesel).
ISTAP** = These variable speed and variable length models include alcohol-gasoline
compatibility (up to 85% ethanol, up to 20% Biodiesel, or 100% Biodiesel) and
Advanced Protection with powder-coated, e-coated, and stainless steel components. (B)
RISER
YYYYY = Factory Installed Options LENGTH
Model designations may include one or more of the following characters in alphabetical
order:
F = Floating suction adapter (1½" NPT female adapter)
K = Intake filter screen (IFS, factory installed to PMA)
M = MagShell® (flow enhancing, expanded PMA shell)
R* = Model R check valve (1.7 bar relief / 1.5 bar reset for PLLD)
W* = Model W check valve (1.1 bar relief / 0.9 bar reset for PPM4000)
(A)
Z = Pump Motor Horsepower Rating MODEL
VS2 = 2 Hp variable speed LENGTH
TECHNICAL ADVANTAGES
OPTIONAL FEATURES
Biofuel Compatibility Turbine Pump Interface
FE PETRO® pumps are UL listed with both UL79A (up to 85% Remote enhanced pump monitoring and control including
Ethanol) and UL79B (up to 20% or 100% Biodiesel). pump-in-water automation, clogged intake escalation, tank
leveling, and tank priority.
Variable Length
The patented telescoping pump shaft lets installers adjust the Intake Filter Screen
length of the pump onsite for the perfect fit. Avoid system damage, pumping slowdowns, and reduce filter
changes by keeping harmful tank debris, sediment, and
Advanced Protection corrosion from entering the pumping system with this factory-
Stop corrosion in its tracks. Special powder-coated, e-coated, installed option.
and stainless steel components defend your pump in the tank
and in the sump from accelerated corrosion.
STANDARD FEATURES
Active Air Eliminator Manual Pressure Relief
FE PETRO® STPs come standard with active air elimination, As a standard FE PETRO® feature, a vent screw is provided to
which eliminates air through the highest point in the pump head bleed line pressure to zero when necessary. By turning this
at all times when the pump is running, assuring air does not screw, product is diverted back to the tank, dropping line
pass into discharge piping. pressure to zero. This reduces fuel discharged into the sump
manhole or dispenser pan during servicing, further protecting
Safety and Ease of Maintenance service technicians and the environment.
FE PETRO® STPs include a contractor electrical disconnect,
which requires loosening only one bolt, allowing motor wiring to Outlast, Outperform with Franklin Electric Inside
be disconnected without venting the dangerous tank vapors into FE PETRO® STPs are powered by the legendary Franklin Electric
the sump when servicing FE PETRO® submersible products. motor and built for long term performance. Franklin Electric-
powered submersible pumps provide maximum uptime and a
Simple Servicing proven track record in the fueling industry that spans more than
four decades. They feature best-in-class flow rates and a long
If ever required, the pump can be easily removed from the tank
history of dependability.
by unthreading three bolts. There is no need to disconnect the
syphon system or to remove the leak detector from the system
to service the STP. Quality Certification
Franklin Fueling Systems is an ISO 9001 Certified Manufacturer.
SPECIFICATIONS
General Power Requirements
• 1½ Hp fixed speed models are available in variable length • 150B fixed speed models require single-phase, 200-250 VAC,
and fixed length options. 50 Hz incoming power. 150C fixed speed models require
three-phase 380-415 VAV, 50 Hz incoming power.
• Check valve: 70mm diameter fluorocarbon seal constructed
with cast aluminum body and steel backing washer. • 150B fixed speed models incorporate a starting and running
capacitor, with internal bleed resistor, rated 440 Volt, 15
• Pressure relief valve: available in four pressure relief settings,
microfarad.
integral to check valve. Standard model relieves at 2.8 bar
and resets above 2.4 bar. • SPGC single-phase Guardian™ Series Controllers and
STP-CBBS single-phase control boxes are available for 150B
• Syphon: venturi-type syphon primer supplied with every
pump control.
submersible. Syphon check valve and secondary syphon sold
separately. • STP-SCIIC three phase controllers and STP-CBB3C three-
phase magnetic starters are available for 150C control.
• Air eliminator: every submersible includes a tank return path
with one-way check valve to provide active air elimination. • Max. motor draw: 150B 9 Amps, 150C 3 Amps.
• Electrical disconnect: electrical yoke for positive contractor Liquid Compatibility
disconnect during service.
• Max. liquid viscosity: 70 SSU at 60 °F (15 °C).
Pump Motor • Standard STP models are UL and cUL listed for fuel
• 1½ Hp fixed speed, 2875 rpm, multi-stage centrifugal type mixtures containing up to 10% ethanol with gasoline, and
pump motor with integral, automatic, thermal overload 20% MTBE, 20% ETBE or 17% TAME with gasoline.
protection.
• STPAP/STPAG (AG compatible) models are UL listed for fuel
• Standard pressure (three-stage) model, max. pressure = mixtures containing diesel fuel with up to 20% Biodiesel,
2.62 bar. 100% Biodiesel, up to 85% ethanol with gasoline, and 20%
• High pressure (four-stage) model, max. pressure = 3.31 bar. MTBE, 20% ETBE or 17% TAME
with gasoline.
• 1½ Hp fixed speed models can also be used with diesel
Approvals fuels, fuel oils, kerosene, Avgas, and jet fuels in a non-gelled
• cULus listed. pourable state.
• Consult factory for applicable approvals. • All wetted elastomers are made of a high grade,
fluorocarbon compound.
45 45
40 40
35 35
Total Head in Meters
30 30
25 25
20 20
15 15
10 10
5 5
0 0
0 50 100 150 200 250 300 350 400 450 0 500 50 100 150 200 250 300 350 400 450 50
Flow in Liters per Minute (LPM) Flow in Liters per Minute (LPM)
Note: Performance based on pumping gasoline (0.78 specific gravity). Pressure is taken at the manifold discharge outlet. Note: Performance based on pumping gasoline (0.78 specific gravity). Pressure is taken at the manifold discharge outlet.
150B models are powered by a 250 Volt power supply. 150C models are powered by a 415 Volt power supply.
ORDERING INFORMATION
1½ Hp Fixed Speed Submersible Pump Ordering Guide
A typical turbine model designation has up to five components
to define the pump being supplied as follows:
STP XXXXX Y - A - B
STP = Basic Model Designation
XXXXX = Factory Installed Options (Model designations may
include one or more of the following characters in
alphabetical order.)
(B)
AP = Advanced Protection with powder-coated, e-coated, and RISER
LENGTH
stainless steel components, alcohol-gasoline compatible (up to
E85, up to B20, and B100) (Note standard models up to 10%
ethanol capable)
AG = Alcohol-gasoline compatible (up to E85, up to B20, and
B100) (Note standard models up to 10% ethanol capable)
F = Floating suction adapter (1½" NPT female adapter)
K = Intake filter screen (IFS, factory installed to PMA) (A)
MODEL
*R = Model R check valve (1.7 bar relief / 1.5 bar reset for PLLD) LENGTH
*W = Model W check valve (1.1 bar relief / 0.9 bar reset for
PPM4000)
Y = Pump Motor Horsepower Rating
150B = 1½ hp fixed speed, 50 Hz, single-phase
150C = 1½ hp fixed speed, 50 Hz, three-phase
A = Model Length (see table)
VL1 = Variable length range #1.
VL2 = Variable length range #2.
VL3 = Variable length range #3.
(Note VL2 models fit 94% of all known installations)
B = Riser Pipe Length (see diagram)
Riser pipe length is expressed as two numeric characters that
Model Length (A)
indicate the total length of the riser in inches. Riser pipes are
available from 178mm to 1524mm in 25mm increments STP
Model Length Range Model Length Designation
(additional charge for risers 787mm or longer). Horsepower
1556mm – 2298mm VL1
150B 1½ Hp
Notes: *If not otherwise specified, all STP models are supplied with standard model 2344mm – 3905mm VL2
Fixed Speed
check valve (2.8 bar relief / 2.4 bar reset for MLD, TS-LS300, and TS-LS500). 3156mm – 5499mm VL3
1531mm – 2273mm VL1
150C 1½ Hp
2318mm – 3879mm VL2
Fixed Speed
3131mm – 5473mm VL3
Note: High pressure option adds about 13mm to PMA and model length.
ORDERING INFORMATION
Single-Phase 1½ Hp Fixed Speed Submersible Turbine Pumps
Model Length Range
Model Description Model Length Range*
Number
STP150B-VL1 1½ Hp fixed speed VL1 1556mm – 2298mm
STP150B-VL2 1½ Hp fixed speed VL2 2344mm – 3905mm
STP150B-VL3 1½ Hp fixed speed VL3 3156mm – 5499mm
STPH150B-VL1 1½ Hp high pressure fixed speed VL1 1569mm – 2311mm
STPH150B-VL2 1½ Hp high pressure fixed speed VL2 2357mm – 3918mm
STPH150B-VL3 1½ Hp high pressure fixed speed VL3 3169mm – 5512mm
TECHNICAL ADVANTAGES
OPTIONAL FEATURES
Biofuel Compatibility Turbine Pump Interface
FE PETRO® pumps are UL listed with both UL79A (up to 85% Remote enhanced pump monitoring and control including
Ethanol) and UL79B (up to 20% or 100% Biodiesel). pump-in-water automation, clogged intake escalation, tank
leveling, and tank priority.
Variable Length
The patented telescoping pump shaft lets installers adjust the Intake Filter Screen
length of the pump onsite for the perfect fit. Avoid system damage, pumping slowdowns, and reduce filter
changes by keeping harmful tank debris, sediment, and
Advanced Protection corrosion from entering the pumping system with this factory-
Stop corrosion in its tracks. Special powder-coated, e-coated, installed option.
and stainless steel components defend your pump in the tank
and in the sump from accelerated corrosion.
STANDARD FEATURES
Active Air Eliminator Manual Pressure Relief
FE PETRO® STPs come standard with active air elimination, As a standard FE PETRO® feature, a vent screw is provided to
which eliminates air through the highest point in the pump head bleed line pressure to zero when necessary. By turning this
at all times when the pump is running, assuring air does not screw, product is diverted back to the tank, dropping line
pass into discharge piping. pressure to zero. This reduces fuel discharged into the sump
manhole or dispenser pan during servicing, further protecting
Safety and Ease of Maintenance service technicians and the environment.
FE PETRO® STPs include a contractor electrical disconnect,
which requires loosening only one bolt, allowing motor wiring to Outlast, Outperform with Franklin Electric Inside
be disconnected without venting the dangerous tank vapors into FE PETRO® STPs are powered by the legendary Franklin Electric
the sump when servicing FE PETRO® submersible products. motor and built for long term performance. Franklin Electric-
powered submersible pumps provide maximum uptime and a
Simple Servicing proven track record in the fueling industry that spans more than
four decades. They feature best-in-class flow rates and a long
If ever required, the pump can be easily removed from the tank
history of dependability.
by unthreading three bolts. There is no need to disconnect the
syphon system or to remove the leak detector from the system
to service the STP. Quality Certification
Franklin Fueling Systems is an ISO 9001 Certified Manufacturer.
SPECIFICATIONS
General Power Requirements
• ¾ Hp fixed speed models are available in variable length and • 75B fixed speed models require single-phase, 200-250 VAC,
fixed length options. 50 Hz incoming power. 75C fixed speed models require
three-phase, 380-415 VAC, 50 Hz incoming power
• Check valve: 70mm diameter fluorocarbon seal constructed
with cast aluminum body and steel backing washer. • 75B fixed speed models incorporate a starting and running
capacitor, with internal bleed resistor, rated 440 Volt,
• Pressure relief valve: available in four pressure relief settings,
15 microfarad.
integral to check valve. Standard model relieves at 2.8 bar
and resets above 2.4 bar. • SPGC-220 single-phase Guardian™ Series Controllers and
STP-CBBS single-phase control boxes are available for 75B
• Syphon: venturi-type syphon primer supplied with every
pump control.
submersible. Syphon check valve and secondary syphon sold
separately. • STP-SCIIIC three-phase smart controller and STP-CBB3C
three-phase magnetic starter are available for 75C control
• Air eliminator: every submersible includes a tank return path
with one-way check valve to provide active air elimination. • ¾ Hp max. motor draw: 75B 6 Amps, 75C 3 Amps.
• Electrical disconnect: electrical yoke for positive contractor Liquid Compatibility
disconnect during service. • Max. liquid viscosity: 70 SSU at 60 °F (15 °C).
Pump Motor • Standard STP models are UL and cUL listed for fuel
• ¾ Hp fixed speed, 2875 rpm, two-stage centrifugal type mixtures containing up to 10% ethanol with gasoline, and
pump motor with integral, automatic thermal overload 20% MTBE, 20% ETBE or 17% TAME with gasoline.
protection. • STPAG/STPAP (AG compatible) models are UL listed for fuel
• ¾ Hp models have a max. pressure of 2.55 bar. mixtures containing diesel fuel with up to 20% Biodiesel,
100% Biodiesel, up to 85% ethanol with gasoline, and 20%
MTBE, 20% ETBE or 17% TAME with gasoline.
Approvals • ¾ Hp fixed speed models can also be used with diesel fuels,
• cULus listed. fuel oils, kerosene, Avgas, and jet fuels in a non-gelled
pourable state.
• Consult factory for applicable approvals.
• All wetted elastomers are made of a high grade,
fluorocarbon compound.
45 45
40 40
35 35
Total Head in Meters
Total Head in Meters
30 30
25 25
20 20
15 15
10 10
5 5
0 0
0 50 100 150 200 250 300 350 400 450 0 500 50 100 150 200 250 300 350 400 450 50
Flow in Liters per Minute (LPM) Flow in Liters per Minute (LPM)
Note: Performance based on pumping gasoline (0.78 specific gravity). Pressure is taken at the manifold discharge outlet. Note: Performance based on pumping gasoline (0.78 specific gravity). Pressure is taken at the manifold discharge outlet.
75B models are powered by a single-phase, 250 Volt power supply. 75C models are powered by a single-phase, 415 Volt power supply.
ORDERING INFORMATION
¾ Hp Fixed Speed Submersible Pump Ordering Guide
A typical turbine model designation has up to five components to
define the pump being supplied as follows:
STP XXXXX Y - A - B
STP = Basic Model Designation
XXXXX = Factory Installed Options (Model designations may
include one or more of the following characters in
alphabetical order.)
AP = Advanced Protection with powder-coated, e-coated, and (B)
stainless steel components, alcohol-gasoline compatible (up to RISER
LENGTH
E85, up to B20, and B100) (Note standard models up to 10%
ethanol capable)
AG = Alcohol-gasoline compatible (up to E85, up to B20, and
B100) (Note standard models up to 10% ethanol capable)
F = Floating suction adapter (1½" NPT female adapter)
K = Intake filter screen (IFS, factory installed to PMA)
(A)
*R = Model R check valve (1.7 bar relief / 1.5 bar reset for PLLD) MODEL
LENGTH
*W = Model W check valve (1.1 bar relief / 0.9 bar reset for
PPM4000)
Y = Pump Motor Horsepower Rating
75B = ¾ Hp fixed speed, 50 Hz, single-phase
75C = ¾ Hp fixed speed, 50 Hz, three-phase
A = Model Length (see table)
VL1 = Variable length range #1.
VL2 = Variable length range #2.
VL3 = Variable length range #3.
(Note VL2 models fit 94% of all known installations)
B = Riser Pipe Length (see diagram)
Riser pipe length is expressed as two numeric characters that Model Length (A)
indicate the total length of the riser in inches. Riser pipes are
available from 178mm to 1524mm in 25mm increments STP
Model Length Range Model Length Designation
Horsepower
(additional charge for risers 787mm or longer).
1499mm – 2241mm VL1
Notes: *If not otherwise specified, all STP models are supplied with standard model 75B ¾ Hp
2286mm – 3848mm VL2
check valve (2.8 bar relief / 2,4 bar reset for MLD, TS-LS300, and TS-LS500). Fixed Speed
3099mm – 5441mm VL3
1480mm – 2222mm VL1
75C ¾ Hp
2267mm – 3829mm VL2
Fixed Speed
3080mm – 5422mm VL3
ORDERING INFORMATION
Single-Phase ¾ Hp Fixed Speed Submersible Turbine Pumps
Model Length Range
Model Description Model Length Range*
Number
STP75B-VL1 ¾ Hp fixed speed VL1 1499mm – 2241mm
STP75B-VL2 ¾ Hp fixed speed VL2 2286mm – 3848mm
STP75B-VL3 ¾ Hp fixed speed VL3 3099mm – 5441mm
Notes:
1. STP models are compatible with fuel mixtures containing up to 10% ethanol with gasoline, up to 5% Biodiesel with diesel fuels, and 20% MTBE, 20% ETBE or 17% TAME
with gasoline. STPAG/STPAP models are compatible with fuel mixtures containing diesel fuel with up to 20% Biodiesel, 100% Biodiesel, up to 85% ethanol with gasoline, and
20% MTBE, 20% ETBE or 17% TAME with gasoline.
2. All models are supplied with a standard check valve unless factory option “R” or “W” is specified.
3. All above 75B models require single-phase, 200-250 VAC, 50 Hz incoming power. All above 75C models require three-phase, 380-415 VAC, 50 Hz incoming power.
4. 4" riser pipe, if supplied locally, must be 4½" OD by 3/16" WT tubing.
5. For riser pipe lengths 787mm to 1524mm, additional charges apply. (Call Customer Service for lead times.)
*Model length (A) defined as the dimension from turbine manifold bottom to pump motor inlet.
Factory Installed Approvals
Specified in model number at time of STP order.
Model Description
(ATXF) Submersible Turbine Pumps with ATEX Flameproof approval for EN markets
(RT) Submersible Turbine Pumps with ROSTEST approval for Eastern European markets
Note: If not otherwise specified, all models are supplied to UL approval as standard. Consult factory for local approvals.
franklinfueling.com
3760 Marsh Rd. • Madison, WI 53718, USA
Tel: USA & Canada +1 800 225 9787 • Fax: +1 608 838 6433
© 2020 Franklin Fueling Systems. All Rights Reserved.
Tel: UK +44 (0) 1473 243300 • Tel: Mex 001 800 738 7610
Tel: DE +49 6571 105 380 • Tel: CH +86 10 8565 4566 FFS-0801 02-21