0% found this document useful (0 votes)
405 views2 pages

Electrical Cable Layout Plan

This document contains a drawing with three sentences: 1) It includes a legend section labeling various aspects of the drawing. 2) There are elevation notes showing invert elevations for different areas. 3) The drawing depicts site features including a ramp, landing, and battery area along with equipment like a data logger and transformer.

Uploaded by

vishnutry
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
405 views2 pages

Electrical Cable Layout Plan

This document contains a drawing with three sentences: 1) It includes a legend section labeling various aspects of the drawing. 2) There are elevation notes showing invert elevations for different areas. 3) The drawing depicts site features including a ramp, landing, and battery area along with equipment like a data logger and transformer.

Uploaded by

vishnutry
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DWG NO. 21121 EL DWG 0023 REV.

1 3 4 5 6 7 8 9 10 11 12 13 14 15 16

LEGEND
A A
INV -1
D
D

450 Wp PV TABLE

D
D
INV -2
E E

SLOPE 1:5
RAMP
LANDING
RS

50
ACDB

300

DATA LOGGER
AMPLUS
BATTERY
100

UPS DB

200
AUX
TRANSFORMER
UPS

A A' A'
FFL. +0.600
EQUIPMENT ROOM 1200 750
5750x4840

1000 400 700 1700

5330

11KV VCB PANEL

MAIN LT PANEL
1750

2500
A A' A'

1000

500
6200

A A C C

8.0
CABLE TRAY

2.5
200kW INVERTER
TRANSFORMER
YARD FENCE

1000kVA TRANSFORMER

GATE

8.72
2.5

2.5
F'
F'

F F
INV -1
D
F F
D
INV-3
E E

AC CABLE TRENCH 240sqmm


B B

m
E E

qm
INV-4
DD

0s
24
INV-5
DD
200X100 mm HT CABLE TRAY

m
A A

qm
HT CABLE IN EXISTING OH

0s
AA

24
B

STRUCTURE
A B
A

ENTRY GATE

D
HUME PIPE

D
INV -2
E E

mm
C C

240sq
qm
m NOTE:
0s
24
ALL DIMENSION ARE IN METER
m m
0sq OTHERWISE MENTIONED

SLOPE 1:5

RAMP
LANDING
RS

24

50

300
ACDB

DATA LOGGER
BATTERY

AMPLUS
100

UPS DB

200
AUX
TRANSFORMER

CABLE SHALL BE LAY AS PER IS1255 1983 CODE


UPS

A A' A'
FFL. +0.600
EQUIPMENT ROOM 1200 750
5750x4840

1000 400 700 1700

5330

11KV VCB PANEL

MAIN LT PANEL
1750

2500
D A A' A' D
OF PRACTICE FOR INSTALLATION & MAINTENANCE.

1000

500
6200

A A C C
LT CABLE TO BE LAID IN UNDERGROUND TRENCH.

24
8.0
CABLE TRAY

0s
qm
2.5
TRANSFORMER
YARD FENCE

HT CABLE TO BE LAID IN LADDER TYPE CABLE

m
1000kVA TRANSFORMER

GATE

8.72
TRAY WITH COVER.
2.5

2.5
RS485 CABLE AND AUX POWER CABLE WILL BE

24
0s
LAID IN CONDUIT.

qm
m
F'
F' CABLE TRAY FOR HT CABLE IS REQUIRED FROM
F F ICOG PANEL IN MCR TO EXISTING OVERHEAD
E STRUCTURE OF DAIMLER. E

240sqmm
F F

INV-3
E E

qmm
240s
F F

m
sqm
240
E E

INV-4
DD

qmm
240s
G G

qmm
240s
DD

INV-5

H H

A A

A A
I B I
A B
A

Interconnection room ENTRY GATE N

J J

W E

K K
S
RELEASE STATUS DATE DRAWN
PRELIMINARY
AMPLUS ENERGY SOLUTIONS PVT LTD
TENDER ONLY
FOR CONSTRUCTION AC CABLE ROUTE LAYOUT
ARCHITECTURAL AMPLUS ENERGY SOLUTIONS PVT LTD
CIVIL STRUCTURAL
6TH FLOOR, EMAAR MGF-THE PALM SQUARE, SECTOR 66,
REVIEWED

GOLF-COURSE EXTENSION ROAD, GURGAON, INDIA. DAIMLER INDIA COMMERCIAL VEHICLES, CHENNAI
ISSUED FOR CONSTRUCTION : REVISED WITH 200kW INVERTER NS DS 1 06.05.2021 ELECTRICAL 06.05.2021 DS
L L
DRAWN : DS NS SCALE : NTS
ISSUED FOR CONSTRUCTION NS DS 0 20.03.2021 INSTRUMENTATION REVIEWED : NS SHEET : 1 OF 2 DATE : 06.05.2021

MECH. INST. ELEC. STRL. ARCH. APPROVED: NS PROJECT NO : 21121


MECHANICAL
APPROV. NATURE OF REVISION & DESCRIPTION CHECKED DRAWN REV. DATE
REVIEWED DWG. NO: 21121 EL DWG 0023 REV. 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
DWG NO. 21121EL DWG 0023 REV. 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A A

CANOPY

3.3kV,3R,3C,
B
11kV, 3C, 240 SQMM, AL, 11kV, 3C, 240 SQMM, AL, 300SQMM, AL, AR CABLE B

AR CABLE AR CABLE
200 200x100 LADDER TYPE 200 200x100 LADDER TYPE 500x100 LADDER TYPE 500
CABLE TRAY WITH COVER CABLE TRAY WITH COVER CABLE TRAY

100
100

100
FGL

FO CABLE IN 11kV, 3C, 240 SQMM, AL,


FO CABLE IN 40MM CONDUIT AR CABLE
AUX POWER CABLE 200x100 LADDER TYPE

300
C 40MM CONDUIT C
200
IN 40MM CONDUIT CABLE TRAY WITH COVER

100

500
300

300
FO CABLE IN NOTE:
40MM CONDUIT
*ALL DIMENSION ARE IN MILLIMETER OTHERWISE
FGL FGL FGL FGL FGL FGL MENTIONED
D D
*CABLE SHALL BE LAY AS PER IS1255-1983 CODE
OF PRACTICE FOR INSTALLATION & MAINTENANCE.

E E

TYPICAL CABLE RACK TYPICAL CABLE RACK TYPICAL CABLE RACK


TYPICAL CABLE RACK
ARRANGEMENT FOR A-A ARRANGEMENT FOR A'-A' ARRANGEMENT FOR C-C
ARRANGEMENT FOR B-B

F F

ROAD
FGL

BACK FILL

350
RS485 CABLE IN
32MM CONDUIT

EARTH STRIP

900
ROUTE MARKER ROUTE MARKER ROUTE MARKER ROUTE MARKER
G
EVERY 30M , BEND EVERY 30M , BEND EVERY 30M , BEND EVERY 30M , BEND G
AC & ROAD CROSSING AC & ROAD CROSSING AC & ROAD CROSSING AC & ROAD CROSSING
FGL FGL FGL FGL
200MM HUME PIPE

3.3kV, 3C, 240SQMM,


BACKFILL BACKFILL BACKFILL BACKFILL AL, AR, XLPE CABLE
300

300

300
300
350

350

350
350

TYPICAL CROSS SECTION OF


WARNING TAPE WARNING TAPE AC CABLE ROAD CROSSING

WARNING TAPE WARNING TAPE


600

600

600
RS485 CABLE IN RS485 CABLE IN
600

H H
32MM CONDUIT 32MM CONDUIT
755

755

755
1055

1055

1055
755
1055
900

900

900
900

RS485 CABLE IN RS485 CABLE IN AUX POWER CABLE


32MM CONDUIT 32MM CONDUIT IN 32MM CONDUIT

EARTH STRIP EARTH STRIP EARTH STRIP EARTH STRIP

BACKFILL BACKFILL BACKFILL BACKFILL


I I

BRICK LAYER BRICK LAYER BRICK LAYER BRICK LAYER


70

70

70
70

RIVER SAND RIVER SAND RIVER SAND RIVER SAND


75

75

75
75

3.3kV,3C, 240SQMM, AL, AR, 3.3kV,3C, 240SQMM, AL, AR, 3.3kV,3C, 240SQMM, AL, AR, 3.3kV,3C, 240SQMM, AL, AR,
XLPE CABLE XLPE CABLE XLPE CABLE XLPE CABLE N
75

75

75
75
80

80

80
80

J
120 200 80 200 80 200 80 J
300 500 800 800

3.3kV AC CABLE TRENCH 3.3kV AC CABLE TRENCH 3.3kV AC CABLE TRENCH 3.3kV AC CABLE TRENCH W E
SECTION D-D SECTION E-E SECTION F-F SECTION F'-F'

K K
S
RELEASE STATUS DATE DRAWN
PRELIMINARY
AMPLUS ENERGY SOLUTIONS PVT LTD
TENDER ONLY
FOR CONSTRUCTION CROSS SECTION OF CABLE ROUTE
ARCHITECTURAL AMPLUS ENERGY SOLUTIONS PVT LTD
CIVIL STRUCTURAL
6TH FLOOR, EMAAR MGF-THE PALM SQUARE, SECTOR 66,
REVIEWED

GOLF-COURSE EXTENSION ROAD, GURGAON, INDIA. DAIMLER INDIA COMMERCIAL VEHICLES, CHENNAI
ISSUED FOR CONSTRUCTION : REVISED WITH 200kW INVERTER NS DS 1 06.05.2021 ELECTRICAL 06.05.2021 DS
L L
DRAWN : DS CHECKED : NS SCALE : NTS
ISSUED FOR CONSTRUCTION NS DS 0 20.03.2021 INSTRUMENTATION REVIEWED : NS SHEET : 2 OF 2 DATE : 06.05.2021

MECH. INST. ELEC. STRL. ARCH. APPROVED: NS PROJECT NO : 21121


MECHANICAL
APPROV. NATURE OF REVISION & DESCRIPTION CHECKED DRAWN REV. DATE
REVIEWED DWG. NO: 21121 EL DWG 0023 REV. 1