CONTENT
SVC 1 Safety Cautions..............................................................3
2 Features........................................................................4
(500VA-5000VA)
2.1 Time-delay output function..........................................4
2.2 Automatic protection function......................................4
2.3 Overload/Overheat protection..................................... 4
2.4 Frequency Adaptive....................................................4
3 Specifications ................................................................4
4 Product Introduction........................................................5
4.1 LED display................................................................5
4.2 Meter display..............................................................5
4.3 LCD display................................................................5
4.4 Socket-type rear panel................................................5
4.5 Terminals -type rear panel............................................6
5 Installation and Application..............................................6
6 Maintenance...................................................................7
6.1 Preventive maintenance...............................................7
6.2 Abnormal states handling.............................................7
7 Packing list.....................................................................8
USER MANUAL
1 2
1. Safety Cautions
Please comply with the following instructions to make sure safety
using
P (% )
■Keep the equipment in adequate ventilation and clean
environment(minimum 100mm away from the wall). During 100%
using the equipment, it is normal that the case surface 75%
temperature reach around 50℃ 50%
■There is voltage output for AVR when switch on; There is no 25%
voltage output when switch off
U(v)
■ Do not open the cover in case getting an electric shock. 145 175 260
■ Do not place any liquid container on the top of the equipment Input voltage and output power curve
in case of equipment damaged or danger of electric shock.
■ Do not use under overload in case of any danger
■ Do not store or use the equipment in the following Warning!The equipment must properly grounded.
environment:
l The place which has flammable gas, corrosive things or a
2. Feafures
lot of dust;
l The place where temperature is abnormally high or low 2.1 Time-delay output function
(above 40℃ or below -10℃), or humidity is high (above All stabilizers have time-delay output function, press the
90%); time-delay button on the front panel ( choose 180sec/6sec),
l The palce under sunshine or the place close to the meanwhile the time-delay indicator light will illuminate, here
heater instrument;
the AVR is in protection states without output, it can provent
l The palce which has strenuous vibration;
electromotor, refrigeratory and compressor etc. from being
l The place where the children can reach easily
damaged due to frequent on and off.
■ If there is fire, please use powder fire extinguisher. It is
2.2 Automatic protection function
dangerous to use fluid extinguisher;
■ Place receptacles near by the equipment, in case of emergent The equipment inside has Integrated automatic protector, it
states needed to unplug and cut off the power. make real-time monitoring of the output voltage and
■ Within range of rated voltage ±25% 50/60Hz, the equipment completely protect the load. When the output voltage <180V
provide 100% power output; if beyond the range, the output or>255V, the stabilizer will cut off the output automatically,
power should be in accordance with the following diagram: meanwhile the “
high/low”indicator light on the front panel
3 4
will illuminate, it protects the load from electrical safety. Input voltage 100/110/120/220/230/240 -35%,+20%(-45%,+20% option
When the mains recovers to be normal, the equipment will Output voltage 100/110/120/220/230/240±8%
automatically output according to user’
s time-delay setting. P.F. PF=0.6
Short circuit
fuse breaker / breaker
2.3 Overload/overheat protection protection
When an equipment works for a long term under overload, Efficiency >98%
high voltage/ low voltage, it will cause damage. Therefore this 0℃ ~ 40℃
Temperature
product has a special circuit design for overheat, overcurrent 10% ~ 90%
Humidity
protection. When the product inner temperature is higher LED/LED+Meter/LCD
Panel display
than the settled standard value, it will automatically cut off
Communication RS232/USB(option)
the power and turn off, it will prolong using life of the
Dimension 210*2 220*22
stabilizer. 125*155*265 140*200*285
(W*H*D) 10*30 0*350
2.4 Frequency adaptive
0
The equipment adopts advanced micro-computer controled Note : Input/output voltage/frequency can be customer-designed
system, it will automatically track the mains frequency 50HZ according to customers’need.
or 60HZ, automatically adjust datas collection system, adapt
4. Product Introduction:
the system frequency requirement and fullfill the voltage
4.1 LED display:
regulation to meet the output requirement.
Input voltage indicator
3. Specifications
Time-delay selector
Input switch
Working states indication:
Green LED: Working normal;
Orange LED: Time-delay state;
Red LED light long: Input overvoltage/ under-voltage;
Model SVC-500 SVC-800 SVC-1000 SVC-1500 SVC-2000 SVC-3000 SVC-5000 Red LED flash: System protection or fault;
Rating Power 500VA 800VA 1000VA 1500VA 2000VA 3000VA 5000VA 4.2 Meter display:
5 6
Input/Output voltage indicator
Input fuse
Working states indication:
Time-delay selector Green LED: Working normal;
Orange LED: Time-delay state;
Red LED light long: Input overvoltage/
under-voltage; Input/Output terminals
Input switch Red LED flash: System protection or fault;
5. Installation and Application
4.3 LCD display:
5.1 Shut down the load ( such as host computer, fans ect.),
Input/Output voltage indicator
and remove their cables from the mains outlet;
Time-delay selector
5.2 Place the equipment properly ( refer to Safety Cautions);
Working states indication:
Green LED: Working normal; 5.3 Connect the cable of the load with the O/P sockets or
Orange LED: Time-delay state; terminals block of the AVR;
Red LED light long: Input overvoltage/
under-voltage; 5.4 Connect the I/P cable (or terminals block) of the AVR with
Red LED flash: System protection or fault The Mains outlet (or electrical source junction box). ( Make
Input switch
sure the N / L / G connected properly);
4.4 Socket-type rear panel: Provide power to the Load
Output sockets
Input fuse
Input cable
Input cable
4.5 Terminals -type rear panel: 5.5 Plunged into the Mains, Select the time-delay output time
7 8
(3 seconds/ 180 seconds), and make switch “
ON”
, then State Solution
AVR start up .The time-delay indicator (Orange LED) will Whether start-up normally?
LED/LCD meters show
illuminate, the output will count down (3 seconds/ 180 Whether the input power or fuse works
nothing after start-up
seconds), and users can turn on the load after the green normally?
indicator illuminate; No output, Time -delay The equipment is under time -delay state,
5.6 Daily start-up: make panel switch “
ON”
, AVR will provide indicator illuminate please wait 6secs/180secs.
with an normal output; There is Mains, but the Input voltage is beyond of AVR’
s
5.7 Daily off: make panel switch “
Off”
, AVR will be turned off; Equipment don’
t have standard range (higher or lower), please
output; high/low voltage check the input voltage and use the
6. Maintenance indicator illuminate equipment till the input voltage is normal.
6.1 Preventive maintenance: which can guarantee the The equipment output voltage is
equipment realiablity and performance in a long term. Please The Mains is normal; overhigh/overlow; please shut down
make the following inspections monthly:
high/low voltage indicator the equipment first and restart. It
1) Make sure the blowhole not be blocked.
illuminate problem still exist, please send it to the
2) Check whether there is too much dust on the surface.
3) Check whether the input or output cable is fixed and still professionals for maintainance
insulated.
4) Make sure the product not be damped. 7. Packing list:
1) Equipment:1PC
6.2 Abnormal states handling:If there is a failure, please 2) User manual:1pc
3) Fuse:1pc
ask the engineer for help to avoid any further damage or 4) Others:according to customer’
s requirement.
unnecessary cost.
If the equipment works abnormally, please do self-test as
following solutions. If still can not fix the problem, please ask
the distribute or manufacturer for help.
9 10