IO-Link
IO-Link master with
extra power
IO-Link masters
PowerLine Coolant
4 or 8 IO-Link ports with full
V1.1 functionality
Feed-through of the power
supply possible
Master and devices configurable
via the LR DEVICE software
Industry 4.0 ready via
LR AGENT EMBEDDED
Voltage supply via power cable,
M12, T-coded
Robust field bus modules with safe connection
The decentralised IO-Link masters are used as gateways between intelligent
IO-Link sensors and the fieldbus. They are the perfect choice, even in the
most difficult environments: The materials and production methods are
identical to the ifm jumper cables of the tried-and-tested EVC product
series. The ecolink technology guarantees reliable, permanently ingress-
resistant M12 connections of the connection cables.
Extra power
The IO-Link masters are equipped with two T-coded M12 connections for
voltage supply. With this power cabling, the current path can simply be
daisy-chained.
The B ports of the 8-port IO-Link master allow direct connection of IO-Link
actuators, such as valve islands.
Advantages and customer benefits Products
• Sensor configuration with LR DEVICE Type Description Order
no.
The intuitive software finds all IO-Link masters in the
network and creates an overview of the whole plant.
Besides, all sensors connected are indicated with the IO-Link master PowerLine coolant
respective parameters. This means that parameter
setting of all sensors in the system is possible from Profinet 4-port AL1200
one central point.
Profinet 8-port AL1202
• Easy sensor connection
The sensors and actuators are connected via standard EtherNet/IP 4-port AL1220
M12 connection cables without screening.
Depending on the device type, up to 4 or 8 IO-Link EtherNet/IP 8-port AL1222
sensors can be connected and supplied with up to
IO-Link module Coolant
3.6 A. With the EVC693 accessories, additional
auxiliary power for the connection of IO-Link actuators Input module 4 x 2DI AL2400
can be supplied. The cable can be up to 20 m long. Input module 8 x 2DI AL2401
• Direct connection to the IT Output module 6 x 2DO AL2330
The integrated LR AGENT EMBEDDED is capable
of transmitting the process values directly to ERP Technical data
systems, without detour via the PLC.
IO-Link master Order no.
This second communication path is available in PowerLine Coolant
parallel to the fieldbus via the bus wiring. AL1200 AL1202
AL1220 AL1222
• 12 amperes on an M12 connector
Operating voltage [V DC] 20...30
The master supply and the auxiliary power for the
actuators are supplied via T-coded M12 connectors. Total current consumption US / UA [A] ≤ 3.9 / ≤ 3.6
The energy can be looped through the master (daisy IO-Link version 1.1
chain). 4 A ports
Number of IO-Link ports 4 A ports and
4 B ports
Connection technology Number of binary inputs
4+4 4+8
(IO-Link in SIO mode)
Type Description Order Number of binary inputs
no. 4 8
(IO-Link in SIO mode)
Parameter memory •
Ethernet cable (fieldbus) Current for all A ports [A]
≤ 3.6
ifm article no. 78002469 · We reserve the right to make technical alterations without prior notice. · 04 / 2017
(device supply)
0.5 m E12490
Current for all B ports [A]
2m E12090 ≤ 3.6
(actuator supply)
5m E12491 Protection IP 65, IP 67
10 m E12492 Ambient temperature [°C] -25...60
M12 socket 1.5 mm2 (power) polyamide;
Housing materials socket:
0.5 m E12494 nickel-plated brass
2m E12430
5m E12495 Accessories
10 m E12496 Type Description Order
no.
M12 connection cable 0.34 mm2 (sensor)
1m EVC042
2m EVC043 LR DEVICE (supplied on USB flash drive)
Software for online and offline
5m EVC044 QA0011
parameter setting of IO-Link sensors and
10 EVC493 actuators
Y splitter
Protective caps M12
E73004
(10 pcs)
Y splitter, for connection of two
sensors to a port, EBC113
M12 connector / 2x M12 socket
For further technical details please visit: www.ifm.com