Grounding & Lightning Protection System Layout

The document describes the installation of a grounding system for a building. It includes installing an 8" x 3.0 M copper-clad ground rod 1.0 M away from the building side walk. A 60 mm2 bare copper ground wire is exothermically welded to building rebars and runs to a lightning stroke counter unit through a 63mm diameter rigid PVC conduit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views1 page

Grounding & Lightning Protection System Layout

The document describes the installation of a grounding system for a building. It includes installing an 8" x 3.0 M copper-clad ground rod 1.0 M away from the building side walk. A 60 mm2 bare copper ground wire is exothermically welded to building rebars and runs to a lightning stroke counter unit through a 63mm diameter rigid PVC conduit.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

5

8"x 3.0 M. COPPER CLAD


GROUND ROD INSTALLED 60 mm² BARE COPPER
1.0 M. AWAY FROM GROUND WIRE
S I D E
BUILDING LINE W A L K EXOTHERMICALLY S I D E W A L K
WELDED TO REBARS

FEMALE TOILET RENTABLE RENTABLE RENTABLE RENTABLE RENTABLE


11 m² 5 m² 4 m² 5 m² 5 m² 5 m² PANTRY
16 m²
LOUNGE GROUND WELL
HOLDING AREA PRE-DEPARTURE AREA 10 m²
20 m² 240 m² 1 - 60mm2 BARE COPPER
GROUND WIRE in 63mm
DIAMETER RIGID uPVC TOILET
1 m²
CONCUIT THRU LIGHTNING
STROKE COUNTER UNIT.

MANAGER'S
MALE TOILET OFFICE
10 m² 5 m²

MALE TOILET
12 m²
IATF OFFICE
17 m²

TICKETING BOOTH

F
LIGHTNING STROKE
ARRESTER

R
25 m²
(AT ROOF DECK)

U
THERMAL SCANNING
DEPARTURE AREA

T
240 m²

RESTAURANT/

PWD
RENTABLE SPACE

3 m²
ARRIVAL AREA 29 m²
240 m²

PB3

ELECTRICAL /PB2
ELECTRONICSPB1
ROOM
MDP
3 m²
ENTRANCE

S I D E W A L K S I D E W A L K

T U R F T U R F T U R F

R A M P U P

GROUNDING & LIGHTNING PROTECTION SYSTEM LAYOUT

PROJECT TITLE: CERTIFIED BY : PRC NO. : PREPARED BY : CHECKED & REVIEWED BY : RECOMMENDING APPROVAL : APPROVED BY : SHEET CONTENTS : SHEET NO. :
VALIDITY : GROUNDING &
REPUBLIC OF THE PHILIPPINES
DEPARTMENT OF AGRICULTURE
PHILIPPINE RURAL DEVELOPMENT PROJECT
REPUBLIC OF THE PHILIPPINES
REGION VI-WESTERN VISAYAS
PROVINCE OF ILOILO
REHABILITATION AND EXPANSION
OF PUNTALES FEEDER PORT
P T R NO. :

DATE ISSUED :
LIGHTNING PROTECTION

SYSTEM LAY OUT


E-05
BONIFACIO DRIVE , ILOILO CITY 5000
PROJECT SP ID NP.: EVA MAE V. PARRENAS ROMEO ANDIG RAUL N. BANIAS M.D.,MPA ATTY. SUZETTE A. MAMON ARTHUR R. DEFENSOR JR.
PRDP-IB-R006-ILO-010-000-000-2019-AF
PROJECT LOCATION: BRGY. NIPA , CONCEPCION , ILOILO
PLACE ISSUED :

T I N:
M U N I C I P A L E N G I N E E R ACTING PROVINCIAL ENGINEER MUNICIPAL MAYOR , MUNICIPALITY OF CONCEPCION PROVINCIAL ADMINISTRATOR P R O V I N C I A L G O V E R N O R 46-59