Manual - Nado Contracorriente
Manual - Nado Contracorriente
EMDE16030153
INDEX
PART LIST 3
4
5
2 7
1. Safety precautions ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 3 8
1 9
2. Specifications ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...4 10
3. Product structure and name of components ... ... ... ... ... ... ..4-6
4. Installation instructions ... ... ... ... ... ... ... ... ... ... ... ... ... ...7-14
6
5. Operating instructions ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .15 11
6. Maintenance and warrenty ... ... ... ... ... ... ... ... ... ... ... ... ... . 15
7. Control box instructions ... ... ... ... ... ... ... ... ... ... ... ... ... 16-19
12
13
14
2 19
1) Important note: the basic requirements of installation, usage
and maintenance process of users are included in the safety
operating instructions.
A B C 12 V N L1 L2 L3
2) Please follow safety instructions carefully. Failure to adhere to
safety instructions could lead to personal injury.Please pay
Qmax Power
Model Hmax V/Hz
A B 12 V N L1
(m)
m³/h l/min KW HP
AFS40 75 1300 13 3.0 4.0
380/50
AFS55 90 1500 17.5 4.0 5.5
SR30 35 600 20 2.18 3
220/50
SR30X2 70 1200 25 4.36 6
INSTALLATION EXPLAIN
1) The control box must be installed in a dry place.
2) After the control box is fixed . According to the wiring diagram,
NO. Component Specification Material Qty NO. Component Specification Material Qty
the pump and the water light power cord access control box. 1 Tie-in Nut G2¾ ABS 2 22 Front cover ADC12 1
1a Tie-in Nut 3" ABS 2 23 Bearing 1
3) Connect the two transparent air pipes to the corresponding 2 PVC 2 24 Rotor
6205
1
Tie-in Ø60.3 Ø63
pneumatic switches. 2a Tie-in Ø75 Ø90 PVC 2 25 Bearing 6203 1
3 O-Ring d62×4.5 NBR 2 26 Stator 1
3a O-Ring d93.6×5.7 NBR 2 27 Motor House ADC12 1
4 Drainage Plug PA66-GF 2 28 Terminal Box Pad NBR 1
5 O-Ring d11.2×2.4 NBR 2 29 Connection Pole Melamine+Plating Zinc 1
SPECIFICATIONS 6 Screw M10×130 SUS304 6 30 Screw M4×12 Plating Zinc 1
7 Pad Ø10 SUS304 6 31 Spring washer Ø5 SUS304 2
Input voltage 220V / 380V / 110V 8 Pump Casing G2¾ PP-GF 1 32 Pad Ø5 SUS304 2
8a Pump Casing 4½FBT PP-GF 1 33 Screw M4×12 SUS304 2
9 O-Ring d208×6 NBR 1 34 Terminal Box Flame Besistant ABS 1
Water light output voltage AC 12V 10 Impeller Nut PA6-GF 1 35 Screw M4×30 SUS304 4
11 Light Spring Washer d12 SUS304 1 36 Wave Spring Washer D40 65Mn 1
Pump output voltage 220V / 380V / 110V 12 Flat Key 4×12 SUS304 1 37 Back Motor Cover ADC12 1
13 O-Ring d25.2×2.4 NBR 1 38 Hexagon Screw M5×190 SUS304 4
14 Impeller PA66-GF 1 39 Fan 1
Water light power 1W 15 Mechanical Seal 40 Shaft spring pad
PP
SB-20 Carbon/Ceramic/NBR 1 d14 1
16 Screw M8×35 SUS304 4 41 Fan Cover ABS+PC 1
Pump power 4KW 17 Pad PA6 4 42 Belt pad screws SUS304 4
18 O-Ring d6×2 NBR 4 43 Rubber Strap NBR 1
19 Pump Cover PP-GF 1 44 Hexagon Screw M8×16 SUS304 2
20 Shaft Washer d20 NBR 1 45 Pad Ø8 SUS304 2
21 Nut M10 SUS304 6 46 Bracket PP-GF 1
16 5
5) Operating Instructions
Pump parts for SR
1) The water in the swimming pool is sucked from the side of the
nozzle mask to the water pump, and then expelled through
5 6 8 11 12 13
the nozzle.
2) The on/off switch of the water pump and the water lamp are
installed on the cover of the nozzle. It can be operated only
by hand press.
3) The direction of the water output can be adjusted by moving
the nozzle up and down, left and right, while rotating the
2 nozzle can adjust the amount of the water output.
4) If air is needed to be injected into the water, the adjustable
valve on the mask surface can be regulated. (Note: keeping
1 2 3 4 7 9 10 14 15 16 rotating counter-clockwise can twist off the valve)
5) Since during testing three-phase alternating current is used,
the correct rotating direction of the arrow shown on the fan
Key No. Part No. Product Description Qty cover of the engine must be found to indicate the correct
1 89280306 2.0"Union 2 rotating direction of the motor of the water pump.
2 89023601 Connecting 1
6) maintenance and warrenty
3 89021308 SR Pump body 1
1) Clean the nozzle, the pump and the surface of the control
4 89021309 Screw for impeller with O-ring 1
box regularly; check the water pump and the area where
5 02011108 O-Ring for diffuser 1 plastic nozzle ring is sealed regularly. Change if needed.
6 01111015 Diffuser 1 2) Keep the motor clean, to ensure ventilation position ( fan
cover ) does not have any obstacles.
7 01311006 Impeller SR300(220V/50HZ) 1
3) When uninstalling the pump, the pump switch must be closed
8 04015001 3/4″Mechanical seal 1 and all power must be disconnected. The replacement must
9 02011093 O-Ring for flange 1 be performed by a professional officer. Please refer to the
user manual for the Isolation of screw nuts of the inlet and
10 01021013 SR Pump Flange 1
outlet pipe connected to the pump, replacement of
11 03011080 M6×15 Hexagonal screw 16 mechanical seals and the order of assembly installation.
12 02011101 Motor Slinger for 1 4) When maintenance / repair in the freezing winter, it is
necessary to lower the water level which is lower than that of
13 89021304 Motor SR300(220V/50HZ) 1
the nozzle shell. Flow out all of the water in both the inlet and
14 89021310 M8×20 Screw for motor with washer 4 outlet water pipes.
15 01111031 Base with nut & washer for 1 5) When the control box is out of order, it must be maintained by
16 01021021 Opening key 1
qualified electricians or qualified maintainance staff. For
details please refer to the control box user manual.
6 15
No. Specification 4) Installation instructions
1 PVC pipe 2" * 70mm 9 10
11
12 13 I) The counter current jet can be used in Concrete, composite
2 2" pipe elbow(45°) fiberglass and vinyl pools. The installation is as follow:
3 PVC pipe 2" * 70mm
1) Concrete pool installation:
4 2" union ball valve
5 PVC pipe 2" * 100mm 14
a)Use 4 screws(M6*20) to fix the counter current jet plate to the
6 Reducing pipe 2.5" * 2" pool wall hole. ( Figure 1)
7 PVC pipe 2.5" *105mm b) Fit counter current jet body into in to concrete wall. (Figure 2)
8
8 2.5" pipe elbow(45°) 7
9 Reducing pipe 2.5" * 2" 6
10 PVC pipe 2" * 170mm 5
11 2" union ball valve
12 PVC pipe 2" * 220mm 4
~250
13 2" pipe elbow (90°)
3
~310
14 PVC pipe 2" * 170mm
2
remarks: Please take reference from the above 1 1)
piping sequence Figure15
254
(only for SR30 water pump) ∅
No. Specification
23
3
∅
~310
10*3
6°(3
2) 45° 60°) a qualified electrician.
1) water lamp on/off air pipe
5 5
∅2 air valve
pump on/off air pipe
4*90°=360°
∅7
25cm
31cm water lamp power
source wire
swimming pool water pump power source wire
Figure 3
water pump 380V(220V)
O-ring
O-ring Figure13
compressed ring
screw
No. Specification 8 9
1 PVC pipe 2.5" *175mm 10 11
panel
~250
10*3
~310
6°(3
2) 45° 60°)
1)
5 4
∅2
∅7
4*90°=360°
∅233
Figure 11
3) 18°
Figure 5
screw
Figure 12 Figure 6
12 9
4) The structure of cement bag from inside of the pool and the II)To install counter current jet outer shell
outercasing installation methods of counter current jet: 1) First use ¢5 transparent air tube and LED light cable respectively
a) Embedded the counter current jet outer casing inside the to pass through the connecting tube, then connect the two air
cement wall and the surface of the outer case should be pipes to the pump switch and pool light air switch respectively.
completed with the cement surface.(figure 8) ( Figure9)
b) Opened the corresponding holes from inside of the cement 2) Pass through the two pipes respectively from the hole of the
bag and the holes should be completed with the fiber pool support frame; and then use 4 M6 screws to fix the support
(figure 3). frame onto the shell.( Figure 10)
c) Used 10 screws of M6X30 and fixed the rubber ring into the 3) Connect the pipes of the shell to the side of the mask of the air
mounting ring. (figure 8) button. Connect the gas nozzle of the support frame to the
concrete structure
cement bag
middle of the gas nozzle (Figure 11); (Note: must not be reversed)
4) Install the outer shell onto the support frame, fixed with 4 M5
O-ring screws, and then cork the screw hole using plastic cork.
(Figure12)
transparent pipe
Figure 7
water lamp electric cable
supporting frame
pipe
Figure 9
water pump air on/off
pipe
concrete pool wall
O-ring
nozzle shell
O-ring
compressed ring
screw
screw
Figure 10
Figure 8
10 11