0% found this document useful (0 votes)
140 views

Manual - Nado Contracorriente

The document provides instructions for the COUNTER CURRENT JET product. It includes: 1. A parts list that identifies 14 parts included in the product, including the thermal overload relay, contactors, breakers, switches, tracks, boards, transformer, control box, and cables. 2. Safety precautions that instruct users to read the manual carefully, follow safety instructions to prevent injury, only have qualified persons perform installation, and ensure the pool water is properly balanced. 3. A wiring diagram for the 380V control box that shows how to connect the input power, pump cable, water light cable, and control box wiring.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
140 views

Manual - Nado Contracorriente

The document provides instructions for the COUNTER CURRENT JET product. It includes: 1. A parts list that identifies 14 parts included in the product, including the thermal overload relay, contactors, breakers, switches, tracks, boards, transformer, control box, and cables. 2. Safety precautions that instruct users to read the manual carefully, follow safety instructions to prevent injury, only have qualified persons perform installation, and ensure the pool water is properly balanced. 3. A wiring diagram for the 380V control box that shows how to connect the input power, pump cable, water light cable, and control box wiring.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

Product Name: COUNTER CURRENT JET

Product Model No.: EM0055

Please read this manual carefully before using the product


please keep this manual for future reference

EMDE16030153
INDEX
PART LIST 3
4
5
2 7
1. Safety precautions ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 3 8

1 9
2. Specifications ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...4 10

3. Product structure and name of components ... ... ... ... ... ... ..4-6

4. Installation instructions ... ... ... ... ... ... ... ... ... ... ... ... ... ...7-14
6
5. Operating instructions ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .15 11

6. Maintenance and warrenty ... ... ... ... ... ... ... ... ... ... ... ... ... . 15

7. Control box instructions ... ... ... ... ... ... ... ... ... ... ... ... ... 16-19

12

13
14

Item No. Part No. Product Description Qty


1 04014099 thermal overload relay 1
04014100 AC contactor(220V)
2 1
04014121 AC contactor(110V)
3 04014101 breaker 2
4 04014103 pneumatic switch 2
5 04014102 earth terminal 1
6 04014019 track 1
7 04014104 terminal fixing parts 2
8 04014107 clapboard 3
9 04014108 wiring terminal 2
10 04014105 head board 2
04014109 transformer(220V)
11 1
04014122 transformer(110V)
12 04014110 control box 1
13 04014013 cable gland 1
14 04014085 cable gland 2

2 19
1) Important note: the basic requirements of installation, usage
and maintenance process of users are included in the safety
operating instructions.
A B C 12 V N L1 L2 L3
2) Please follow safety instructions carefully. Failure to adhere to
safety instructions could lead to personal injury.Please pay

special attention to wiring of 3 phase motors to ensure shaft


rotation is in the direction of arrow.
3) Installation must be carried out by qualified persons. Electrical
work must be carried out by a qualified electrician.
4) Emaux Water Technology is not liable for any damages
personal or property if equipment is installed by unauthorized
persons or not in line with installation and safety instructions
provided.
water light cable input power(380V)
pump cable 5) Please read instructions and operating instructions thoroughly.
6) Please ensure pool water is balanced at all times. Operating
380V control box wiring diagram
equipment above the maximum water temperature will lead
to damages.
7) The safety instructions for repair and maintenance,inspection
X1 PE N L1 L2 L3 and the operation engineering must ensure that the performance
of repair and maintenance, checking and installation are
L1 L2 L3
K2 2 2 approved by qualified technician to work. Staff responsible for
1 3 5 K2
KM
1 1
the work need read the manual thoroughly. The industrial
97 95
F2 96
F2 95 accident prevention rules must be obeyed. All the work relating
2 4 6 98 96
T1 T2 T3
KM
A2 to pump only can be done when it is stopped. The procedures
A1
mentioned in the operating instructions of the pump must be
T1 230V
transformer X1 1 2 3 PE PE obeyed. The products harmful to health carried by the pump
12V
or counter current jet must be purified.
8) If the box has been opened, please check all components are
supplied.
LED
M 9) counter current jet is a countercurrent facility using in any
3 ~ swimming pools.
pneumatic switch

380V/50Hz counter current jet circuit diagram


18 3
2) Specifications CONTROL BOX WIRING DIAGRAM & CIRCUIT DIAGRAM
1) Pump model parameters

Qmax Power
Model Hmax V/Hz
A B 12 V N L1

(m)
m³/h l/min KW HP
AFS40 75 1300 13 3.0 4.0
380/50
AFS55 90 1500 17.5 4.0 5.5
SR30 35 600 20 2.18 3
220/50
SR30X2 70 1200 25 4.36 6

3) Product description and parts breakdown


1 ) counter current jet parts list
Key No. Part No. Description Qty

1 89090104 Air botton for water pump 1 1 2


3
2 89090105 Air Adjusting 1 4 input power(220V)
water light cable
5 pump cable
3 89090106 Air Button for Water Light 1
6
4 89090107 Threaded Plug for Lid 1 220V/110V control box wiring diagram
5 03011345 M5*20mm Screws 4 12 7
8
6 89090108 Lid 1
9 X1
L
7 88041939 LED spa light 1w, 12v RGB 1 PE N
10
13
7 88041940 LED spa light 1w, 12v white 1
11 1 5
8 89090110 Support Frame 1 14 L
N 2 2
K1 K2
1 1
9 89090111 Water Jet 1 15 KM
2 6
97 95 F2 96
10 01093016 D12mm x 8mm x 40mm Air Ajusting Hose 2 F2 95
98 96
A2
11 01093015 D5mm x 3mm x 3M Transparent Hose 2 KM
A1
16 18
12 03011320 M6 x 20 Screw (AISI316) 4
110V or 220V
13 89090112 Water Jet Fixed Pipe 1 T1 transformer X1 1 2 3 PE PE
12V
14 89090113 Vinyl Pool Fittings 1

15 89090114 Swim Jet Body 1

16 89090115 Conduit for Light Cable and Air Hose 1


LED
17 89090116 Cable Grand 1 M

18 01151380 Exhaust Hose 1


17 19 2
~
pneumatic switch

19 89090117 Venting Plug 1


220V/50Hz, 110V/60Hz counter current jet circuit diagram
4 17
2)AFS40/55 parts list
COUNTER CURRENT JET CONTROL BOX
Model: SWJ-CB (220V / 380V / 110V)
Code: 08080020 / 08080021/ 08080034

APPLICABLE FOR BETWEEN EMAUX


COUNTER CURRENT JET AND PUMP CONTROL.
Warning:
This electrical control box must be installed by
a licensed or certified electrician or a qualified
serviceman in accordance to the requirements of your government
standard or local authorities. Improper installation will create electric
hazards which could result in serious injury, death as well as damage
to the property.

CUT THE POWER BEFORE SERVICE AND MAINTAINANCE!

INSTALLATION EXPLAIN
1) The control box must be installed in a dry place.
2) After the control box is fixed . According to the wiring diagram,
NO. Component Specification Material Qty NO. Component Specification Material Qty
the pump and the water light power cord access control box. 1 Tie-in Nut G2¾ ABS 2 22 Front cover ADC12 1
1a Tie-in Nut 3" ABS 2 23 Bearing 1
3) Connect the two transparent air pipes to the corresponding 2 PVC 2 24 Rotor
6205
1
Tie-in Ø60.3 Ø63
pneumatic switches. 2a Tie-in Ø75 Ø90 PVC 2 25 Bearing 6203 1
3 O-Ring d62×4.5 NBR 2 26 Stator 1
3a O-Ring d93.6×5.7 NBR 2 27 Motor House ADC12 1
4 Drainage Plug PA66-GF 2 28 Terminal Box Pad NBR 1
5 O-Ring d11.2×2.4 NBR 2 29 Connection Pole Melamine+Plating Zinc 1
SPECIFICATIONS 6 Screw M10×130 SUS304 6 30 Screw M4×12 Plating Zinc 1
7 Pad Ø10 SUS304 6 31 Spring washer Ø5 SUS304 2
Input voltage 220V / 380V / 110V 8 Pump Casing G2¾ PP-GF 1 32 Pad Ø5 SUS304 2
8a Pump Casing 4½FBT PP-GF 1 33 Screw M4×12 SUS304 2
9 O-Ring d208×6 NBR 1 34 Terminal Box Flame Besistant ABS 1
Water light output voltage AC 12V 10 Impeller Nut PA6-GF 1 35 Screw M4×30 SUS304 4
11 Light Spring Washer d12 SUS304 1 36 Wave Spring Washer D40 65Mn 1
Pump output voltage 220V / 380V / 110V 12 Flat Key 4×12 SUS304 1 37 Back Motor Cover ADC12 1
13 O-Ring d25.2×2.4 NBR 1 38 Hexagon Screw M5×190 SUS304 4
14 Impeller PA66-GF 1 39 Fan 1
Water light power 1W 15 Mechanical Seal 40 Shaft spring pad
PP
SB-20 Carbon/Ceramic/NBR 1 d14 1
16 Screw M8×35 SUS304 4 41 Fan Cover ABS+PC 1
Pump power 4KW 17 Pad PA6 4 42 Belt pad screws SUS304 4
18 O-Ring d6×2 NBR 4 43 Rubber Strap NBR 1
19 Pump Cover PP-GF 1 44 Hexagon Screw M8×16 SUS304 2
20 Shaft Washer d20 NBR 1 45 Pad Ø8 SUS304 2
21 Nut M10 SUS304 6 46 Bracket PP-GF 1

16 5
5) Operating Instructions
Pump parts for SR
1) The water in the swimming pool is sucked from the side of the
nozzle mask to the water pump, and then expelled through
5 6 8 11 12 13
the nozzle.
2) The on/off switch of the water pump and the water lamp are
installed on the cover of the nozzle. It can be operated only
by hand press.
3) The direction of the water output can be adjusted by moving
the nozzle up and down, left and right, while rotating the
2 nozzle can adjust the amount of the water output.
4) If air is needed to be injected into the water, the adjustable
valve on the mask surface can be regulated. (Note: keeping
1 2 3 4 7 9 10 14 15 16 rotating counter-clockwise can twist off the valve)
5) Since during testing three-phase alternating current is used,
the correct rotating direction of the arrow shown on the fan
Key No. Part No. Product Description Qty cover of the engine must be found to indicate the correct
1 89280306 2.0"Union 2 rotating direction of the motor of the water pump.
2 89023601 Connecting 1
6) maintenance and warrenty
3 89021308 SR Pump body 1
1) Clean the nozzle, the pump and the surface of the control
4 89021309 Screw for impeller with O-ring 1
box regularly; check the water pump and the area where
5 02011108 O-Ring for diffuser 1 plastic nozzle ring is sealed regularly. Change if needed.
6 01111015 Diffuser 1 2) Keep the motor clean, to ensure ventilation position ( fan
cover ) does not have any obstacles.
7 01311006 Impeller SR300(220V/50HZ) 1
3) When uninstalling the pump, the pump switch must be closed
8 04015001 3/4″Mechanical seal 1 and all power must be disconnected. The replacement must
9 02011093 O-Ring for flange 1 be performed by a professional officer. Please refer to the
user manual for the Isolation of screw nuts of the inlet and
10 01021013 SR Pump Flange 1
outlet pipe connected to the pump, replacement of
11 03011080 M6×15 Hexagonal screw 16 mechanical seals and the order of assembly installation.
12 02011101 Motor Slinger for 1 4) When maintenance / repair in the freezing winter, it is
necessary to lower the water level which is lower than that of
13 89021304 Motor SR300(220V/50HZ) 1
the nozzle shell. Flow out all of the water in both the inlet and
14 89021310 M8×20 Screw for motor with washer 4 outlet water pipes.
15 01111031 Base with nut & washer for 1 5) When the control box is out of order, it must be maintained by
16 01021021 Opening key 1
qualified electricians or qualified maintainance staff. For
details please refer to the control box user manual.
6 15
No. Specification 4) Installation instructions
1 PVC pipe 2" * 70mm 9 10
11
12 13 I) The counter current jet can be used in Concrete, composite
2 2" pipe elbow(45°) fiberglass and vinyl pools. The installation is as follow:
3 PVC pipe 2" * 70mm
1) Concrete pool installation:
4 2" union ball valve
5 PVC pipe 2" * 100mm 14
a)Use 4 screws(M6*20) to fix the counter current jet plate to the
6 Reducing pipe 2.5" * 2" pool wall hole. ( Figure 1)
7 PVC pipe 2.5" *105mm b) Fit counter current jet body into in to concrete wall. (Figure 2)
8
8 2.5" pipe elbow(45°) 7
9 Reducing pipe 2.5" * 2" 6
10 PVC pipe 2" * 170mm 5
11 2" union ball valve
12 PVC pipe 2" * 220mm 4

~250
13 2" pipe elbow (90°)
3

~310
14 PVC pipe 2" * 170mm
2
remarks: Please take reference from the above 1 1)
piping sequence Figure15
254
(only for SR30 water pump) ∅

No. Specification
23
3

1 2.5" pipe tee


2 PVC pipe 2.5" * 105mm
3 PVC pipe 2.5" *105mm 45° 45°
4 2.5" pipe elbow (90°) 24
5 2.5" pipe elbow (90°) 22
20 26 32
PVC pipe 2.5" * 105mm 28
6
21
30 Figure 1
7 PVC pipe 2.5" * 105mm
8 Reducing pipe 2.5"*2" 23 34
9 Reducing pipe 2.5" * 2" 25 36
27
10 PVC pipe 2" * 95mm
11 PVC pipe 2" * 95mm
3 5
12 2" pipe elbow(90°) 1
13 2" pipe elbow(90°) 38
2
14 PVC pipe 2" * 125mm 29 cement structural layer
15 PVC pipe 2" * 125mm 4 31
7 33 35
16 2" union ball valve
17 2" union ball valve
pool wall
18 PVC pipe 2" * 70mm 6 9
PVC pipe 2" * 70mm 37
19
20 2.5" pipe tee 8 11
21 PVC pipe 2.5" * 105mm
22 PVC pipe 2.5" * 105mm 13 17
23 2.5" pipe elbow(90°) 15
24 2.5" pipe elbow(90°) 10
25 PVC pipe 2.5" * 105mm 19
26 PVC pipe 2.5" * 105mm
27 Reducing pipe 2.5" * 2"
28 Reducing pipe 2.5" * 2"
29 PVC pipe 2" * 95mm
30 PVC pipe 2" * 95mm 12
31 2" union ball valve 14
32 2" union ball valve 16 nozzle shell
33 PVC pipe 2" * 70mm 18
34 PVC pipe 2" * 70mm
35 2" pipe elbow(90°) Figure16
36 2" pipe elbow(90°)
(only for 2XSR30 water pump) Figure 2
37 PVC pipe 2" * 150mm
38 PVC pipe 2" * 150mm
remarks: Please take reference
from the above piping sequence
7
14
2 ) Composite Fibreglass pool installation: III . Installation of counter current jet
a) Using the template drill 14 holes into the fibgrelass pool shell. 1) Please refer to figure 13 for the whole installation.
( Figure 3) 2) For each model of pump pipe please refer to figure 14, 15, 16.
b) Install the outer shell, plastic ring, in the correct order on the 3) Pumps and contror box must be installed in dry areas. It is
pool shell wall. ( Figure 4) absolutely necessary to expel water at the bottom part.
c) Mount the counter current jet faceplate onto the fiber pool 4) In order to ensure normal operation of air switch, the distance
using 10 piece of M6 screws. (Hole 1 in Figure 3) between the swimming pool and the controller box
must not be more than 3 meters.
5) The air pipe must be installed in the protective pipe. It can be
replaced if necessary.
~250

6) The installation of electric connections must be performed by

~310
10*3
6°(3
2) 45° 60°) a qualified electrician.
1) water lamp on/off air pipe
5 5
∅2 air valve
pump on/off air pipe
4*90°=360°

∅7

∅233 380V power supply input wire

25cm
31cm water lamp power
source wire
swimming pool water pump power source wire

Figure 3
water pump 380V(220V)

nozzle shell vinyl pool wall counter current jet

O-ring

O-ring Figure13
compressed ring
screw
No. Specification 8 9
1 PVC pipe 2.5" *175mm 10 11

2 2.5" pipe elbow(45°) 7


12
13
3 PVC pipe 2.5" * 105mm
4 2.5"union ball valve
5 PVC pipe 2.5" * 105mm
6 2.5" pipe elbow(45°) 6

7 2.5" pipe elbow(45°) 14


5
8 PVC pipe 2.5" * 120mm
9 2.5" pipe elbow(45°)
10 PVC pipe 2.5" * 105mm 4

11 2.5" union ball valve


12 PVC pipe 2.5" * 105mm 3
2 1
13 2.5" pipe elbow(90°)
14 PVC pipe 2.5" * 175mm
remarks: Please take reference Figure14
Figure 4 from the above piping sequence (only for AFS40/50 water pump)
8 13
3) To install a counter current jet shell onto a vinyl pool:
a) For vinyl pool, according to the 16 holes on the counter
current jet shell, first drill holes on the structural wall accordingly.
( Figure 5)
b) Install the plastic ring and the outer shell with 2 M6*20 screws
(hole 3 of Figure 5 ), and then install the plastic ring and ring
for installing on the fiber pool using 10 M6*45 screws .(Figure6)

panel

~250
10*3

~310
6°(3
2) 45° 60°)
1)
5 4
∅2
∅7

4*90°=360°
∅233
Figure 11

3) 18°

Figure 5

nozzle shell outer pool wall


O-ring

inner pool wall


O-ring
screw
air switch compressed ring screw
plastic plug

screw

Figure 12 Figure 6
12 9
4) The structure of cement bag from inside of the pool and the II)To install counter current jet outer shell
outercasing installation methods of counter current jet: 1) First use ¢5 transparent air tube and LED light cable respectively
a) Embedded the counter current jet outer casing inside the to pass through the connecting tube, then connect the two air
cement wall and the surface of the outer case should be pipes to the pump switch and pool light air switch respectively.
completed with the cement surface.(figure 8) ( Figure9)
b) Opened the corresponding holes from inside of the cement 2) Pass through the two pipes respectively from the hole of the
bag and the holes should be completed with the fiber pool support frame; and then use 4 M6 screws to fix the support
(figure 3). frame onto the shell.( Figure 10)
c) Used 10 screws of M6X30 and fixed the rubber ring into the 3) Connect the pipes of the shell to the side of the mask of the air
mounting ring. (figure 8) button. Connect the gas nozzle of the support frame to the
concrete structure
cement bag
middle of the gas nozzle (Figure 11); (Note: must not be reversed)
4) Install the outer shell onto the support frame, fixed with 4 M5
O-ring screws, and then cork the screw hole using plastic cork.
(Figure12)

transparent pipe
Figure 7
water lamp electric cable

supporting frame

pipe
Figure 9
water pump air on/off

pipe
concrete pool wall

cement bag water lamp air on/off

O-ring
nozzle shell

O-ring
compressed ring
screw

screw
Figure 10
Figure 8

10 11