Position Sensor: Type 1

1. The document provides instructions for connecting a toroidal transformer to a power supply for a remote control system. 2. Wires from the power supply should be connected to terminals "T" and "P" on the transformer, with the order of the "P" wires not being important. 3. The transformer comes in different voltage types that connect to different colored wires on the power supply to match the nominal supply voltage.

Uploaded by

Karsim Boim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
981 views2 pages

Position Sensor: Type 1

1. The document provides instructions for connecting a toroidal transformer to a power supply for a remote control system. 2. Wires from the power supply should be connected to terminals "T" and "P" on the transformer, with the order of the "P" wires not being important. 3. The transformer comes in different voltage types that connect to different colored wires on the power supply to match the nominal supply voltage.

Uploaded by

Karsim Boim
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CIRCUIT DRAWN WITH POWER SUPPLY OFF FOR TYPICAL REMOTE CONTROL

DETAILS, SEE DOCUMENT

PLUG SELECTED VOLTAGE WIRE INTO


RWS102
TERMINAL "T"
PLACE TWO REMAINING WIRES INTO TRANSFORMER VOLTAGE OPTIONS:
POSITIONS "P"
(ORDER NOT IMPORTANT)
1 AC CONNECT CORRESPONDING
TOROIDAL
POWER COLOUR TO "T"
TRANSFORMER 2 SUPPLY
TYPE 1
3
GREY 100V
FS1 - 5A
E PURPLE 110V
ANTISURGE
SK20 FS1 BROWN 120V
FS2 P P T 3 TYPE 2
_ GREY 200V
FS1 - 2.5A
+

SK14 PURPLE 230V


ANTISURGE
BROWN 270V
SK15 TYPE 3
SK2
0VAC 1 GREY 380V
FS1 - 2.0A
M SK12 120VAC 4
PURPLE
BROWN
400V
415V
ANTISURGE
0VDC
3 4 TYPE 4
24VDC
24VDC 6 GREY 480V
POSITION _ 5 NOMINAL SUPPLY
FS1 - 2.0A
+
10 WAY SK1 (OUTPUT) PURPLE 575V
SENSOR PS1 SK11
BROWN 690V
ANTISURGE
0VDC 1
INTERNAL SUPPLY FS2 - 20A ATO FAST ACTING ALL TYPES
SK16 24VDC 2 FOLO / CPT PCB
SK4
3 2 1 4 SK9 1 2 TYPE 5 DC (ONLY)

FS1
SK7 SK2 1 +
BATTERY FS3
26 WAY
FS2

+ - SK6 SK3 2 -
FS3 (IF FITTED) 100mA SK3 1 4 3 2 SK13 2 1 SK14 DC/DC
CONVERTER
6 SK9 SK8 1 42
SK5 SK4
5 MONITOR 3 43
RELAY SK20
2 44
SK7
SK10
1 6 _
S1

+
MAKE AT FULLY SHUT SK14
8 7
2 8 SK15
MAKE AT FULLY OPEN S2 7 9
FUSE FS1 - 20A ATO FAST ACTING
3 10 FUSE FS2 - 500mA ANTI-SURGE
BREAK AT FULLY SHUT S3 6 11
4 12 REFER TO SHEET 2 FOR NOTES
BREAK AT FULLY OPEN S4 & OPTION PCB'S IF FITTED
5 13
SK4
CLOSE 9 33
STOP/ MAINTAIN 10 34
50% SK6 OPEN 8 35
COMMON -VE 1 36
18 WAY

ESD 12 25
STOP
CLOSE
LOCAL
OPEN INTERLOCK 13 37
OPEN REMOTE
CLOSE INTERLOCK 14 38
COMMON -VE 5 31
SK1 SK2
SLOT A SLOT B

Iss Date Chkd Revision Details IQT + FOLOMATIC + CPT


3 010415 PMJ Motor control note corrected www. .com
4 010515 PMJ FUSE FS1 CORRECTED ROTORK CONTROLS LTD ROTORK CONTROLS INC Drawn by: JC1 Circuit Diagram Number Issue Sheet
ON TYPE 3/4 Date : 130314 No
BATH, BA1 3JQ ROCHESTER
5 261115 PMJ TYPE 5 DC WIRING
UPDATED.
ENGLAND NY 14624, USA
Base WD: 303B0000
Job No : - -
303B0000 6
1
of 2
6 190619 PMJ PUB002-065 WAS -039 Tel:01225-733200 Tel:585-247-2304 MI No : - - B1 C1 B2 C2
IQ3
CIRCUIT DRAWN WITH POWER SUPPLY OFF

SLOT A
SK1
SLOT A SK3
-VE +VE
1 23 A
2 22
DEMAND +VE 3 26
COMMON -VE 4 27 } ANALOGUE INPUT SIGNAL
FOR FOLOMATIC
FOLOMATIC /

NO CONNECT 5
6 39
CPT

MANUAL/AUTO
COMMON -VE 24VDC 7 41
COMMON -VE 120VAC 8 45
SK6
1 0V
SUPPLY FROM SK11 ON MOTOR CONTROL PCB
2 24V
SK8
1
2

FOR MANUAL/AUTO CONNECTIONS AND


DETAILS OF FOLOMATIC/CPT FUNCTIONS
REFER TO ROTORK PUBLICATION PUB002-041

NOTES
1.FUSES:
-PS1 is a self-resetting fuse. 3.INDICATION:
-Refer to publication PUB002-065 for approved fuses FS1 and FS2. -For typical position, status and alarm indication see PUB002-041.
-Actuator rated voltage specified on nameplate. Voltage tolerance +/-10%, -“S” contacts are user configurable and are shown in their default
applies for rated torque performance; duty cycle is not guaranteed. setting.
2.REMOTE CONTROL: -Refer to PUB002-040 for functions and configuration instructions.
-For typical remote control circuits refer to: -Monitor Relay indicates actuator availability for remote control (shown
-RWS indicated or PUB002-041. “unavailable”). It can be configured to exclude local/remote selection.
-For DC and AC control, connect –ve/0V to terminal 36. -Refer to PUB002-040 for monitored functions and configuration
-(For negative switch / positive common, refer to RWS indicated). instructions.
-Control signal threshold voltages: -Voltage applied to indication contacts must not exceed 150Vac
-DC: “on” ≥16Vdc / “off” ≤8Vdc, max 60Vdc. -Individual Switch current must not exceed 3.5A inductive, 5A resistive
-AC: “on” ≥60Vac / “off” ≤40Vac, max 120Vac. and no more than 8A in total for all 4 contacts.
-Control signal duration to be 300ms minimum.
-Maximum current drawn from remote control signals is: 4.BATTERY:
-8mA at 24Vdc or 12mA at 120Vac. -Battery maintains local and remote “S” contact indication only.
-Supply provided on terminals 4 & 5: -Refer to installation manual for approved replacement battery types.
-Intended for remote control. Circuit Diagram Number Issue Sheet
-Max external load 5W at 24Vdc / 5VA at 120Vac No
2
See Sheet 1 for all Revision details/information 303B0000 6 of 2