Manual Book Pompa 104G5
Manual Book Pompa 104G5
RELATED PRODUCTS
Cast Iron, 495 Series™ / Series™ 4195 Series:
Catalog Section 1441
Steel Externals, 493 Series™ / Series™ 4193 Series:
Catalog Section 1341
GG4197
OPERATING RANGE
* 200 PSI (14 BAR) for above 750 SSU (162 cSt), 150 PSI (10 BAR) for 100 to 750 SSU (20 to 162 cSt),
100 PSI (7 BAR) for 38 to 100 SSU (3 to 20 cSt), 75 PSI (5 BAR) for below 38 SSU (3 cSt)
SPECIFICATIONS
Standard Ports ③ Nominal Pump Rating (100 SSU & below) ① Maximum ④ Maximum ②⑤ Approximate
Differential Hydrostatic Maximum Shipping Weight
Port Size 60 Hz 50 Hz Pressure* Pressure Temperature with Valve
Model
Number Inches Port Type GPM m3/h RPM GPM m3/h RPM PSIG BAR PSIG BAR °F °C Lbs. Kg.
GG4197
1 10 2.3 8 1.9 20 9
GG4197-SEP1
HJ4197
20 4.5 1750 17 3.8
HJ4197-SEP1
1½ 50 23
HL4197
Class 30 6.8 25 5.6
HL4197-SEP1
150 1450 200 14 400 27 350 175
AS4197 Flanged 35 8 45 10
AS4197-SEP1
115 52
AK4197
3 50 11 1150 70 16
AK4197-SEP1
AL4197
75 17 95 22 120 55
AL4197-SEP1
A K 4 1 9 7 - S E P 1
Size: Shaft Seal: Basic Series Application Specific Construction:
GG 4 = Mechanical Seal Configuration -SEP1 = Solvent Extraction Pump
HJ
Material of Construction
HL
7 = Stainless Steel
AS Mounting:
AK 1 = Foot Mount
AL
Threaded one-piece
bearing housing allows for Class 150 flanged ports
end clearance adjustment enable easy in-line mounting
to almost any piping system
One-piece casing ensures alignment
for maximum bearing and seal life
MOUNTING OPTIONS
Model A U V
Number (in) B D E F G H J K L M N O P S T (in) (in) W X
GG4197 in 4.00 2.75 1.62 1.31 4.00 2.44 0.34 0.94 0.03 0.66 1.12 0.31 0.62 7.31 1.12 .12 x 2.66 0.38
1 0.50
GG4197-SEP1 mm 102 70 41 33 102 62 9 24 1 17 29 8 16 186 29 .06 67 10
HJ4197 in 4.00 4.12 1.75 2.00 5.00 3.50 0.41 1.50 1.25 0.88 1.50 0.44 0.62 10.00 1.62 .19 x 2.84 0.75
1½ 0.75
HJ4197-SEP1 mm 102 105 44 51 127 89 10 38 32 22 38 11 16 254 41 .09 72 19
HL4197 in 4.00 4.12 1.75 2.00 5.00 3.50 0.41 1.50 1.25 0.88 1.50 0.44 0.62 10.00 1.62 .19 x 2.84 0.75
1½ 0.75
HL4197-SEP1 mm 102 105 44 51 127 89 10 38 32 22 38 11 16 254 41 .09 72 19
Model A U V
Number (in) B D E F G H J K L M N O P S T (in) (in) W X Z
AS4197 in 6.00 5.25 2.88 2.00 6.75 4.00 0.41 2.25 1.25 1.00 2.00 0.44 1.12 12.12 2.38 .25 x 7.00 0.50 1.56
3 1.00
AS4197-SEP1 mm 152 133 73 51 171 102 10 57 32 25 51 11 29 308 60 .12 178 13 40
AK4197 in 6.00 5.25 2.88 2.00 6.75 4.00 0.41 2.25 1.25 1.00 2.00 0.44 1.12 12.12 2.38 .25 x 7.00 0.50 1.56
3 1.00
AK4197-SEP1 mm 152 133 73 51 171 102 10 57 32 25 51 11 29 308 60 .12 178 13 40
AL4197 in 6.00 5.25 2.88 2.00 6.75 4.00 0.41 2.25 1.75 1.00 2.50 0.44 1.12 12.12 2.38 .25 x 7.00 0.50 1.56
3 1.00
AL4197-SEP1 mm 152 133 73 51 171 102 10 57 44 25 64 11 29 308 60 .12 178 13 40
These dimensions are average and not for construction purposes. Certified prints on request.
A
Model Motor Frame Size (in) B D E F H J K L M M1 N P S
GG4197 in 4.00 3.50 1.50 20.50 0.75 0.75 8.50 0.38 3.78 0.62 0.62 4.25
56, 143T, 145T 1 —
GG4197-SEP1 mm 102 89 38 521 19 19 216 10 96 16 16 108
in 4.00 3.50 ① 2.12 20.50 0.75 0.75 8.50 — 4.34 0.62 0.62 4.25
56, 143T, 145T 1½
HJ4197 mm 102 89 54 521 19 19 216 — 110 16 16 108
HJ4197-SEP1 in 4.00 4.50 2.94 29.00 1.00 1.50 9.00 0.25 4.34 0.62 0.62 4.50
182, 182T, 184, 184T 1½ —
HL4197 mm 102 114 75 737 25 38 229 6 110 16 16 114
HL4197-SEP1 in 4.00 5.25 2.94 29.00 1.00 1.50 9.00 0.25 4.34 0.62 0.62 4.50
213, 213T, 215, 215T 1½
mm 102 133 75 737 25 38 229 6 110 16 16 114
in 6.00 4.50 ② 3.69 29.00 1.00 1.50 9.00 — 7.00 1.12 0.62 4.50
AS4197 182, 182T, 184, 184T 3
AS4197-SEP1 mm 152 114 94 737 25 38 229 — 178 29 16 114
AK4197 in 6.00 5.25 2.94 34.00 1.00 1.50 9.00 — 7.00 1.12 0.62 4.50
213, 213T, 215, 215T 3 —
AK4197-SEP1 mm 152 133 75 864 25 38 229 — 178 29 16 114
AL4197 in 6.00 6.25 4.00 39.00 1.38 1.38 16.00 3.75 7.00 1.12 0.62 8.00
AL4197-SEP1 254U, 254T, 256U, 256T 3
mm 152 159 102 991 35 35 406 95 178 29 16 203
These dimensions are average and not for construction purposes. Certified prints on request.
NPSH REQUIRED
Printed performance curves are not available.
Performance curves can be electronically generated with the Viking Pump Curve Generator on vikingpump.com.
NPSHR data is not available on the curve generator.
NPSH (Net Positive Suction Head): The NPSHR (Net Positive Suction Head Required by the pump) is given in the table below
and applies for viscosities through 750 SSU. NPSHA (Net Positive Suction Head – Available in the system) must be greater than
the NPSHR. For a complete explanation of NPSH, see Application Data Sheet AD-19.
FOR VISCOSITIES UP TO 750 SSU – See NPSHR table below.
NPSHR for high viscosities can be estimated using the following method:
1. Calculate line loss for a 1 foot long pipe of a diameter matching the pump inlet port size. Use your flow rate and max viscosity.
2. Convert this value into Feet of Liquid (S.G. 1.0)
3. Add this value to the NPSHR value in the chart below.
Note: NPSHR – FEET OF LIQUID (Specific Gravity 1.0), Viscosities up to 750 SSU