Product Data Sheet - ProfessionalPLUS Station Software Suite - DeltaV
Product Data Sheet - ProfessionalPLUS Station Software Suite - DeltaV
November 2019
Introduction Benefits
Are you looking for a process control system that gives you Global database, designed for flexibility and scalability.
a single point-of-entry database with access to a complete The ProfessionalPLUS Station includes a state-of-the-art,
integrated system? object- oriented database. This centralized database also
provides a single point of entry for all DeltaV data. From
The ProfessionalPLUS object-oriented, global database gives
history to OPC, to control strategy configuration, the DeltaV
you the power to access all your data—including from third-
ProfessionalPLUS Station has it all. No data mapping is required
party applications.
for communications between a workstation and the controllers.
The ProfessionalPLUS Station comes with a complete set of
Graphical engineering capabilities. Engineer your system your
operating, diagnostic and engineering tools. From IEC 61131-
way. Design your process control system in an environment
3 graphical control strategy configuration and debugging, similar to Microsoft® Windows. Use the high-resolution graphics
to graphics and history configuration, the ProfessionalPLUS and drag-and-drop features for total engineering capabilities.
Station has it all. User management is performed so you can set
Implement using the pre-engineered library templates
up your user privileges and system security from this
or customize them to fit your needs. Your process control
one location.
system will be up and running in record time using DeltaV
You need one ProfessionalPLUS Station per DeltaV™ system. A system engineering.
ProfessionalPLUS Station is made up of the ProfessionalPLUS
Robust and secure plant operation. Every DeltaV workstation
Station Software Suite and the DeltaV hardware to run it. This
has direct access to all operating information, from the current
workstation contains the central DeltaV database.
process values and operating displays, to having alarms with the
Use the unique DeltaV Flexlock feature to securely lock proper alarm priority, timestamp and alarm help.
operators into the DeltaV system, limiting user access to only
the Windows applications that you choose, while also giving
engineers the ability to access Windows applications,
as needed.
ProfessionalPLUS Station Software Suite November 2019
Built-in, reliable operations features such as prioritized alarms Integrated system and device diagnostics. The DeltaV system
and user-security increase usability. Easily customize the offers an integrated approach to diagnostics with the look
standard operating desktop to fit your specific operational and feel of the Windows Explorer. No longer do you have to
philosophies and work preferences. remember which diagnostics package to use or how to work
each package—critical when the plant operation depends on
immediate diagnosis of the situation.
www.emerson.com/deltav 2
ProfessionalPLUS Station Software Suite November 2019
The DeltaV Explorer centralizes all system configuration tasks, including alarm, control and smart device configuration.
The database is scalable, facilitating small and large projects Process control elements, from feed-forward and cascade
and allowing you to expand readily as your needs grow. The control loops to powerful motor control algorithms are
database is open, allowing you to perform data import and predefined in the library. Deployment is simple—drag and drop
export for bulk data entry or to use your favorite tools during to view control and graphic elements.
system configuration.
www.emerson.com/deltav 3
ProfessionalPLUS Station Software Suite November 2019
Users new to the DeltaV system can easily get started with the
DeltaV Configuration Assistant. This wizard walks you through
an overview of the configuration steps to help familiarize you
with the layout and location of configuration.
www.emerson.com/deltav 4
ProfessionalPLUS Station Software Suite November 2019
Each workstation manages its own alarms and data access. This
includes alarm information such as when the alarm occurred,
whether the alarm is suppressed and even access to the specific
help for an alarm. With a DeltaV system, there is no additional
server PC, or other intermediary required to be able to operate
your plant.
Each Operator can be limited to certain plant areas for viewing The included Continuous Historian can collect history locally on
and operating. This security feature can also be defined this workstation. You can have additional Continuous Historians
for an individual station. Use the DeltaV exclusive Flexlock on other workstations. You can view continuous, event, or batch
to ensure that operators remain dedicated to monitoring, historical data, regardless of the DeltaV workstation collecting
troubleshooting, and maintaining the process according to the data. This allows you to centralize or decentralize your
plant operating philosophies. historical collection.
Use the unique DeltaV Flexlock feature to ensure that Emerson Automation Solutions is the industry leader in scalable,
operators remain dedicated to monitoring, troubleshooting, plant-aware process automation systems. Our state-of-the-art,
and maintaining the process according to plant operating totally integrated applications give you the power to do more.
philosophies. Operators are locked in to their system The following software applications are included in the
responsibilities so nothing can preempt their duties. ProfessionalPLUS Station Software Suite.
In a DeltaV system, communications between nodes is totally For detailed information about the following applications,
transparent. You don’t need to know the details associated with refer to the appropriate product data sheet:
the request/response and exception reporting mechanisms
embedded in every DeltaV node to take advantage of DeltaV Alarm Help. Provides Operators with in-context access to
communications. Workstation applications have automatic approved alarm response procedures and control engineers
access to all tags in your process. with native system configuration capability to administer
alarm rationalization data per ISA-18.2 - Management of
Tag information is transparently delivered throughout the alarm systems for the process industries.
DeltaV system so that all parts are aware of the others and can
Configuration Software Suite. Makes it easy to create
simply ask for tag information by name, not by some cryptic
Control Strategies and System Graphics to get your plant up
address or physical location.
and running quickly and efficiently.
DeltaV Diagnostics lets you quickly know the status of your
Control Studio On-line. Graphically monitor and
control system and intelligent field devices. Diagnostics
troubleshoot running control strategies.
information is included not only for your DeltaV Workstations,
Control Network, Controller, and I/O, but also includes support DeltaV Continuous Historian. A 250-parameter DeltaV
for AS-i, DeviceNet, Profibus DP, HART and Foundation Fieldbus Continuous Historian is included with every DeltaV
intelligent devices. workstation. This provides the ability for up to 250 analog,
www.emerson.com/deltav 5
ProfessionalPLUS Station Software Suite November 2019
discrete, and text parameters and their status to be DeltaV Operate. High performance operator graphics,
captured and stored for future analysis. For DeltaV v12.3.1 trends and alarms offered in standard operating layouts and
and newer, three scale-up licenses are available that enable utilizing system-wide built-in security.
up to 3,250 parameters of DeltaV Continuous Historian DeltaV Reporter. View, analyze and report historical process
capacity on any non-Application Station node, including the and alarm and event data from the DeltaV Continuous
operator workstation: Historian and the Event Chronicle in your copy of
yy VE22UPS042OP1 – DeltaV Continuous Historian, Enable Microsoft Excel.
1,250 Parameters
yy VE22UPS042OP2 – DeltaV Continuous Historian, Scaleup
from 1,250 to 2,250 Parameters
yy VE22UPS042OP3 – DeltaV Continuous Historian, Scaleup
from 2,250 to 3,250 Parameters
DeltaV Live - Standard Tier. DeltaV Live is Emerson’s
modern, built-for-purpose operations experience that was
introduced with DeltaV v14.3. It is the first distributed
control system operator interface to natively support
HTML5 graphics. Graphics Studio, the modern and intuitive
engineering environment for DeltaV Live, allows users to
easily create displays, operator station layouts, and even
display hierarchies - all without requiring complex scripting.
In DeltaV v14.3.1, the Standard tier will be available and
includes all the functionality equivalent to DeltaV Operate Diagnose the DeltaV system and intelligent devices.
(runtime and configure), with some enhancements and
additions. Standard tier DeltaV Live functionality will be Diagnostics. Facilitates checking the overall health of your
included with all v14.3.1 ProfessionalPlus workstation system and quickly resolving system hardware, software, and
software (i.e., no additional licenses are required). Please configuration issues.
refer to the DeltaV Live product data sheet here for DeltaV Event Chronicle. Captures process, system and user
more details.
alarms and events and stores them in a Microsoft SQL
Server database.
Flexlock. Creates dual desktops on a single workstation
to ensure that operators remain dedicated to monitoring,
troubleshooting, and maintaining the process according to
plant operating philosophies while also giving engineers the
ability to access restricted areas as needed.
History View Suite. Monitor your plant’s continuous and
event data—historically and in real time.
www.emerson.com/deltav 6
ProfessionalPLUS Station Software Suite November 2019
www.emerson.com/deltav 7
ProfessionalPLUS Station Software Suite November 2019
DeltaV Excel Add-in*. OPC Data Access client application DeltaV InSight. Control performance monitoring and loop
providing read/write access to DeltaV realtime information in tuning application embedded in DeltaV. Identify control
your copy of Microsoft Excel. problems and improve control performance with automatic
process learning, loop diagnostics, on-demand and adaptive
tuning, and automatic report generation.
DeltaV InSight Basic. Basic control performance monitoring
and on-demand loop tuning application available for a single
DeltaV workstation. This option is only applicable when
DeltaV InSight is not included on your system.
DeltaV Remote Access Service for the ProfessionalPLUS.
Enables communications to a remote DeltaV Workstation.
OPC Data Server*. Provides up to 250 real-time process
values to OPC clients on your plant network.
OPC Events Server. Provide DeltaV alarms and events to
third-party applications.
OPC History Server. Exposes all DeltaV historical data using
the industry standard OPC Historical Data Access interface.
Quickly detect alarm patterns with DeltaV Analyze. OPC UA. Provides access to the OPC Classic Servers
(DA,A&E and HDA) in the Professional Plus using the
OPC UA specification.
DeltaV Analyze. Provides web-based analysis of alarms and
events in either the Event Chronicle or Plant Event Historian. OPC Mirror. Transfers thousands of values back and forth
between your DeltaV system and other
OPC-compliant systems.
* The OPC Data Server and the DeltaV Excel Add-in cannot run simultaneously
on the ProfessionalPLUS.
www.emerson.com/deltav 8
ProfessionalPLUS Station Software Suite November 2019
Ordering Information
The ProfessionalPLUS Workstation licenses are based on the Users can choose to have the ProfessionalPlus Premium
DST size of your system. As shown in the table below, there is tier license but only use the Standard tier for the operator
a ProfessionalPLUS Workstation license for version 11.3 and workstations, or vice versa. To take advantage of the DeltaV
earlier systems and a different license for DeltaV version 12.3 Live Premium tier, you will need the ProfessionalPLUS
and newer systems. DeltaV Live was introduced with DeltaV Premium Workstation Software license, which provides
v14.3 and was only available by purchasing the Premium DeltaV Live graphics configuration (engineering) functionality
License tier. In 14.3.1, DeltaV system-wide configuration and for the entire system and DeltaV Live Operations (runtime)
operator workstation licenses will include the DeltaV Live functionality for the ProfessionalPLUS node.
Standard license tier by default. Therefore, the Standard tier
The Standard-to-Premium ProfessionalPLUS Workstation
will not require any additional licenses to be added to the
software license can be used to upgrade existing
ProfessionalPLUS Workstation.
ProfessionalPLUS Workstation licenses to the Premium tier. For
The Standard tier includes all the functionality equivalent more information on DeltaV Live functionality please refer to
to DeltaV Operate Runtime and Configure, with some the DeltaV Live product data sheet here.
enhancements and additions. The following features are
included in the Premium tier of DeltaV Live, but they are not
included in the new Standard tier:
*Where xxxx represents the DeltaV system DST size. The DST size varies from 100 to 30,000 DSTs.
www.emerson.com/deltav 9
ProfessionalPLUS Station Software Suite November 2019
Emerson
North America, Latin America:
©2019, Emerson. All rights reserved.
+1 800 833 8314 or
+1 512 832 3774 The Emerson logo is a trademark and service mark of Emerson Electric Co. The DeltaV logo is
a mark of one of the Emerson family of companies. All other marks are the property of their
Asia Pacific: respective owners.
+65 6777 8211 The contents of this publication are presented for informational purposes only, and while
diligent efforts were made to ensure their accuracy, they are not to be construed as warranties
Europe, Middle East: or guarantees, express or implied, regarding the products or services described herein or their
+41 41 768 6111 use or applicability. All sales are governed by our terms and conditions, which are available on
request. We reserve the right to modify or improve the designs or specifications of our products
www.emerson.com/deltav at any time without notice.