The EM-BIO8-EFCP is an optional plug-in card for controllers that provides one current measurement input that can measure 1A or 5A and up to 8 binary inputs or outputs that can be configured as needed. It is installed by removing the back cover of the controller, inserting the card under the labeled holders, and replacing the back cover. Firmware updates can be done by downloading the newest version from the manufacturer's website, installing it in the configuration software, connecting to the controller, and initiating the update from within the software.

Uploaded by

Cj Bong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
194 views

1 EM-BIO8-EFCP Quick Guide

The EM-BIO8-EFCP is an optional plug-in card for controllers that provides one current measurement input that can measure 1A or 5A and up to 8 binary inputs or outputs that can be configured as needed. It is installed by removing the back cover of the controller, inserting the card under the labeled holders, and replacing the back cover. Firmware updates can be done by downloading the newest version from the manufacturer's website, installing it in the configuration software, connecting to the controller, and initiating the update from within the software.

Uploaded by

Cj Bong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

1 EM-BIO8-EFCP Quick Guide

EM-BIO8-EFCP is optional plug-in card. Through this card controller can accommodate one AC current (CT)
measuring input (1A or 5A input) and up to 8 binary inputs or outputs. In LiteEdit PC configuration tool it is
possible to easily choose if particular I/O will be binary input or output.

Image 1.1 EM-BIO8-EFCP interface

IMPORTANT: Any manipulation with plug-in module shall be done with disconnected power
supply to controller.

IMPORTANT: Earth fault current measurement is supported by controller only in slot A.

Image 1.2 Overview of EM-BIO8-EFCP

EM-BIO8-EFCP Quick Guide, rev. 3, December 2016 1


Firmware upgrade
Download the newest FW of module from ComAp website (in form of PSI file or installation package)
Instal package to computer or open PSI to instal it into LiteEdit
Plug the module into the controller and power the controller on.
Open a connection with controller via LiteEdit
Go the menu Tools -> Firmware upgrade, select the Plug-in modules tab and select the appropriate firmware
you want to program into the module (in LiteEdit).
Press the OK button to start upgrade of firmware.
The firmware update process may be performed via any kind of connection including connection via the same
module in which the firmware is to be updated. The connection is reestablished again automatically when the
update process is finished.
Note: For more information see InteliLiteGlobal Guide on www.comap.cz.

EM-BIO8-EFCP Quick Guide, rev. 3, December 2016 2


Plug-in module installation
Remove the back cover. To do this, press four Insert the plug-in module under holders marked by
holders which are located in corners. symbol 1. Then insert the plug-in module under
holders marked by symbol 2.

After removing back cover insert the plug-in


After locking the plug-in module into holders, place
module. Plug-in module has to be inserted under
back the back cover (small cover for connectors
holders. Start with holders market by symbol 1. On
has to be removed from back cover). Finally insert
the controller are also narrows for better
the small cover for connectors. Small covers are
navigation. After inserting plug-in module under
unique for each plug-in module.
holders 1 press it down to holders market by
symbol 2 which lock the module.

EM-BIO8-EFCP Quick Guide, rev. 3, December 2016 3