0% found this document useful (0 votes)
80 views1 page

Industrial Heating Cable Guide

This document summarizes an industrial self-regulating heating cable suitable for maintaining temperatures up to 120°C on pipes and tanks exposed to corrosives and acids. The cable has copper conductors, a self-regulating conductive core, fluoropolymer insulation, a copper screen, and modified polyolefin outer sheath. It is resistant to corrosives and organic acids. Maximum continuous operating temperature is 120°C, with intermittent operation allowed up to that temperature for less than 1000 cumulative hours.

Uploaded by

José Vera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
80 views1 page

Industrial Heating Cable Guide

This document summarizes an industrial self-regulating heating cable suitable for maintaining temperatures up to 120°C on pipes and tanks exposed to corrosives and acids. The cable has copper conductors, a self-regulating conductive core, fluoropolymer insulation, a copper screen, and modified polyolefin outer sheath. It is resistant to corrosives and organic acids. Maximum continuous operating temperature is 120°C, with intermittent operation allowed up to that temperature for less than 1000 cumulative hours.

Uploaded by

José Vera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Heating Cables INDUSTRIAL USE

SELF-REGULATING
Up to 120°C continuous - 120°C intermittent

MCA-I-GF
Self-regulating heating cables for anti-freeze
or temperature maintenance use with exposure to
corrosives and acids.
Suitable for maintaining process temperatures up to 120°C on piping and tanks, even in
the presence of acids and corrosives, or for anti-freeze use where acids and corrosives are
70
present, in safe areas. Not suitable for use in the presence of steam washing.
60
CONSTITUTION OF THE CABLE MCA20-I-GF
Copper conductors

Power (W/m)
Self regulating conductive core
40
MCA10-GF
Fluoropolymer insulation
30 MCA8-I-GF
MCA5-I-GF

Type of surface to be tracked: Copper screen


20 MCA3-I-GF
Steel - Painted - Stainless Steel.
Chemical resistance: Suitable 10
for exposure to corrosive and 20 40 60 80 100 120
Modified polyolefine outer sheath
organic acids. Pipe temperature (°C)

MAX TEMPERATURE
Minimum Continuous Intermittent Bending
Power Power installation cable cable not powered radius Temperature
voltage at 10°C temperature powered ≤1000 h cum. min. classification
Product (V) (W/m) (°C) (°C) (°C) (mm) EN50014
MCA3-I-GF 230 10 -30 120 120 25 T3
MCA5-I-GF 230 15 -30 120 120 25 T3
MCA8-I-GF 230 25 -30 120 120 25 T3
MCA10-I-GF 230 30 -30 120 120 25 T3
MCA20-I-GF 230 60 -30 120 120 25 T3

ELECTRICAL SIZING Maximum length of the circuits in the heating cable (m)

Starting MCA3-I-GF MCA5-I-GF MCA8-I-GF MCA10-I-GF MC20-I-GF


temperature +10°C -15°C -25°C +10°C -15°C -25°C +10°C -15°C -25°C +10°C -15°C -25°C +10°C -15°C -25°C
Switchgear 16 A 200 180 175 165 130 117 120 97 88 85 73 69 50 41 38
protection (A),
with C curve and 20 A 235 235 235 189 162 152 140 125 120 114 98 92 64 55 52
30mA* differential
protection 30 A - - - - - 189 - - 140 - - 114 - - 64

*Suggested where protection of people is requested; installations with no personnel admittance can be performed with 100 to 300 mA.

Connection accessories for MCA-I-GF


Connection kit integrated Thermal insulation
with the terminal box Termination Kit Joint Kit Branch Kit pass-through kit
MCA Universal IP68 MCA Universal IP68 MCA Universal IP68 MCA-Y MCA-AL

Fixing tape Fixing tape


Cable gland Warning label Fixing tape glass Aluminum 25mm Aluminum 75mm
MCA-PRESS MCA-EA MCA-FV MCA-ALL25 MCA-ALL75

For other accessories see page 222.

219

198-241_cavi scaldanti_ ING_2018.indd 219 04/12/17 15:58