Certofix: Central Venous Catheter Sets

Certofix central venous catheters

Uploaded by

Andrea
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 20

DISCHARGE

PRESCRIPTION PATIENT ACCESS PREPARATION APPLICATION


MANAGEMENT

Certofix®
Central Venous Catheter Sets
Your Partner for Central Venous Catheters

USER ENVIRONMENTS

EMERGENCY ROOM OPERATING ROOM ICU ONCOLOGY PAEDIATRICS

2
BROAD RANGE OF CHOICES FOR ANY APPLICATION
The B. Braun Certofix® product range offers a comprehensive portfolio
of acute central venous catheter (CVC) sets for both adult and paediatric
patients. Certofix® CVCs are used in various acute care environments in the
hospital.

INDICATED THERAPIES
. Vasopressors / Inotropes
. Vessel-irritating drugs
. Parenteral nutrition
. IV Solutions with high osmolality
. Chemotherapy
. Difficult peripheral vein access
. Hemodynamic monitoring *
. Transfusion of blood products

* In combination with other devices e. g. Pulmonary Artery Catheter

3
CVC Placement with Certofix®
B. Braun – Your System Partner for Ultrasound-guided CVC Placement
and ECG-guided Catheter Tip Positioning

POINT OF CARE ULTRASOUND GUIDED CVC PLACEMENT

Safety Seldinger needle Valve needle Safety Scalpel


. Active safety clip (after use) . Allows guidewire insertion and aspira- . The scalpel can be slid back into the
to prevent needle stick injury tion without disconnecting the syringe housing and blocked to prevent sharps
. Prevents air embolism and excessive injury
blood loss during guidewire insertion

4
ECG BASED CENTRAL VENOUS CATHETER TIP PLACEMENT AND POSITION CONTROL

The Nitinol Guidewires Certodyn® Universal Adapters, Alphacard® and ECG Cable
. Flexible and resilient to kinking or knotting, . Accessories to confirm CVC tip position during or after placement via ECG.
to facilitate successful insertion of Compatible with most commonly used ECG monitors.
guidewire and placement of CVC
. “J” and a straight tip in one wire. Both
tips are flexible and suitable for insertion
. All guidewires have length markings

Selected highlight products depicted. See overview on page 8 / 9 (Certofix® Set Configurations).

5
Certofix®
Safety Features in Catheter Use and Maintenance

IN-Stopper (for Certofix® Econoline only) Safsite® valve


. Offers needle access via the . Needle-free Injection / Infusion-Valve
integrated latex-free membrane . Allows infusion and blood withdrawal
. Smooth outer surface for easy disinfection without flow restriction
. Supports contact-free Luer tapers

Also available for the paediatric patients…


Certofix® Paed

Acute central venous catheter sets for infants and paediatric patients
via Seldinger technique.

Choice of catheter Dispenser adapter “Teddy Bear” Statlock fixation*


. Various sizes and lumen available . Premounted to paediatric guidewire Non-sutured catheter fixation
for infant and paediatric patients dispenser . Tolerated by infants and children
according to age, body weight . Facilitates advancing guidewire
and therapy needs tip into the introducer needle

6
Lumen Variants of Certofix® Catheters
Mono Duo Trio Quattro Quinto High Flow Duo
High Flow Trio
proximal proximal proximal

proximal middle 3
middle 2 middle 2 middle
proximal middle
middle 1 middle 1
distal distal distal distal distal distal

Catheter
. Inert and kink-resistant
material (PUR)
. Radio-opaque for catheter
positioning via X-ray
. Length markings

Movable Fixation Clips Soft tip


.
To adjust optimal skin . Soft and pliant
fixation position with tip material (PUR)
sutured or non-sutured
fixation

7
Certofix® Protect
Central Venous Catheters with Proven Non-leaching Antimicrobial Effect
Durable over 30 Days

Leaching Catheter Non-Leaching AM Catheter Non-AM Catheter


Certofix® Protect
Day 7

leaching catheter blood vessel

biofilm formation
Pathogens, e. g. bacteria
Day 30
Destroyed pathogens
Antibiotic drugs or antiseptic,
e. g. chlorhexidine, silver
Illustration of surface modification
AM: Antimicrobial

Antimicrobial CVCs “Leaching” “Non-Leaching”


Antimicrobial Coated or impregnated with silver, antiseptics A non-leaching technology with polymer surface
material (chlorhexidine) or antibiotic drugs modification, on both outer surface and internal
luminal surface
Mode of Action Antimicrobial effect by active release of antibiotic Antimicrobial effect by polymer surface modifi-
drug or antiseptics which directly damage and cation, prevent adhesion of pathogens, microbial
inhibit pathogen growth colonization and biofilm formation 7-9
Durability Antimicrobial activity against pathogen declines signifi- Antimicrobial activity does not decline.
cantly at day 7 and disappears at 28 days of dwell time 10 Proven durability over 30 days 9
Antimicrobial Gaps in antimicrobial spectrum from material Antimicrobial effect proven with all typical
Spectrum with ionized silver or antibiotic drugs 10 CLABSI* eligible pathogens 8-9
Risks and Concerns - Risk of adverse effects from antibiotics 11 - Antibiotic-free
- Concern of antibiotic resistance 11-14

* CLABSI: Central line-associated bloodstream infections Note: The illustrations are to be used for explaining mechanism only
**  CRBSI: Catheter-related bloodstream infections

8
Infectious complications can occur during prolonged use of CVCs
. Central line-associated bloodstream infections, (CLABSI) are associated with increased morbidity, mortality,
and health care costs 1, 2
. Biofilm formation is the key process in the pathogenesis of CLABSI  3, 4

. Risk of CRBSI** rapidly increase from dwell time at day 7-9  5

Certofix® Protect Control (non-antimicrobial CVC) A clinical study with Certofix® Protect has proven
10
(n=616):
p = 0.008 p = 0.036
. 
Use of Certofix® Protect is associated with significant
reduction of blood stream infection (BSI) from
6.5 % to 2 % and from 8.3 to 3.2 / 1,000 Catheter days
. 
The group using Certofix® Protect underwent less
5 antibiotic therapy 6

0
BSI (%) BSI / 1,000 Catheter days

0 DAYS 14 DAYS 30 DAYS The “Roll-out” test showed:


Gram-positive bacteria: Staphylococcus aureus (MRSA) . 
Certofix® Protect prevents microbial colonization
and biofilm formation over 30 days
. 
The antimicrobial efficacy is proven with typical
Control sample bacteria and fungi causing CVC associated blood
stream infection 9

Certofix® protect

The same test results were obtained for:


. Staphylococcus epidermidis, Pseudomonas aeruginosa
. Escherichia coli, Enterococus faecalis
. Klebsiella pneumoniae
. Fungi: Candida albicans

9
Certofix® Set Configurations

Set Configuration Catheter Variants (only one catheter in each set)

Mono Duo Trio Quattro Quinto HF Duo HF Trio

Certofix®
Standard S Sets

Certofix®
Standard V Sets

Certofix®
Protect

Certofix®
High Flow

Certofix®
Safety

Certofix®
Econoline

Certofix®
Paed

HF: high flow

Lumen Variants of Certofix® Catheters

Mono Duo Trio Quattro Quinto High Flow Duo


High Flow Trio

proximal proximal proximal

proximal middle 3
middle 2 middle 2
proximal middle middle
middle 1 middle 1
distal distal distal distal distal distal

10
Accessories

Introducer Nitinol Needle-free Non-sutured


Syringe Scalpel Dilator ECG Cable
Needle Guidewire connector Fixation

Seldinger * Safsite®*

Valve * Safsite®*

Valve * Safsite®*

Valve /
Safsite®
Seldinger

Safety 
** Safsite®*
Seldinger

Seldinger Instopper

Safsite® or
Seldinger * Discofix® 3-way Statlock
stopcock

* Not in sets with Mono Lumen CVC


** Safety Scalpel

ProSet Customized CVC kits in modular system


https://www.bbraun.com/en/products-and-therapies/
services/proset.html#

More Information on Product and Therapy


www.bbraun.com

11
Product Specifications

Certofix® Standard Sets


Name Catheter** Introducer Needle
Certofix® Lumen Size (Fr) Length Lumen Ø (Gauge) min. Flow Rate (ml/min) Filling Volume (ml) Type Gauge
Standard V-Sets (cm) D/M1/M2/M3/P D/M1/M2/M3/P D/M1/M2/M3/P
Mono V 220 1 4 20 18 18 0.315 V 20
Mono V 315 1 5 15 16 60 0.370 V 18
Mono V 320 1 5 20 16 52 0.415 V 18
Mono V 330 1 5 30 16 40 0.510 V 18
Mono V 415 1 6 15 14 90 0.455 V 18
Mono V 420 1 6 20 14 80 0.535 V 18
Mono V 430 1 6 30 14 75 0.690 V 18
Duo V 715 2 7 15 16/16 60/50 0.400/0.335 V 18
Duo V 720 2 7 20 16/16 55/45 0.455/0.380 V 18
Duo V 730 2 7 30 16/16 52/37 0.570/0.470 V 18
Trio V 715 3 7 15 16/18/18 50/28/28 0.340/0.205/0.195 V 18
Trio V 720 3 7 20 16/18/18 46/22/22 0.380/0.215/0.205 V 18
Trio V 730 3 7 30 16/18/18 38/18/18 0.460/0.240/0.230 V 18
Quattro V 815 4 8 15 14/18/18/16 50/20/20/50 0.435/0.205/0.260/0.255 V 18
Quattro V 820 4 8 20 14/18/18/16 40/15/15/40 0.500/0.215/0.280/0.295 V 18
Quattro V 830 4 8 30 14/18/18/16 35/10/10/35 0.635/0.240/0.325/0.380 V 18
Quinto V 1215 5 12 15 16/18/18/18/12 65/32/32/30/225 0.445/0.280/0.280/0.315/1.080 V 18
Quinto V 1220 5 12 20 16/18/18/18/12 55/28/28/28/185 0.515/0.300/0.300/0.340/1.105 V 18

Name Catheter** Introducer Needle


Certofix® Lumen Size Length Lumen Ø (Gauge) min. Flow Rate (ml/min) Filling Volume (ml) Type Gauge
Standard S-Sets (Fr) (cm) D/M1/M2/M3/P D/M1/M2/M3/P D/M1/M2/M3/P
Mono S 215 1 4 15 18 23 0.300 S 20
Mono S 220 1 4 20 18 18 0.315 S 20
Mono S 315 1 5 15 16 60 0.370 S 18
Mono S 320 1 5 20 16 52 0.415 S 18
Mono S 330 1 5 30 16 40 0.510 S 18
Mono S 415 1 6 15 14 90 0.455 S 18
Mono S 420 1 6 20 14 80 0.535 S 18
Mono S 430 1 6 30 14 75 0.690 S 18
Duo S 715 2 7 15 16/16 60/50 0.400/0.335 S 18
Duo S 720 2 7 20 16/16 55/45 0.455/0.380 S 18
Duo S 730 2 7 30 16/16 52/37 0.570/0.470 S 18
Trio S 715 3 7 15 16/18/18 50/28/28 0.340/0.205/0.195 S 18
Trio S 720 3 7 20 16/18/18 46/22/22 0.380/0.215/0.205 S 18
Trio S 730 3 7 30 16/18/18 38/18/18 0.460/0.240/0.230 S 18
Quinto S 1220 5 12 20 16/18/18/18/12 55/28/28/28/185 0.515/0.300/0.300/0.340/1.105 S 18

12
Additional Information Certofix® Standard Sets &
Guidewire *** Other Accessories
Standard S-Sets
Length Ø Syringe Scalpel Dilator Connection Needle Free Article No.* V: Valve Needle, S: Seldinger Needle
(cm) (mm) (Fr) cable ECG Connector Safsite® (REF) D: distal, M: middle, P: proximal
50 0.63 5 ml - 5 1x - 4160215
50 0.89 5 ml - 6 1x - 4160231 The sales unit of Certofix® Standard Sets is 10 pieces / box
50 0.89 5 ml - 6 1x - 4160266 * Note: Please consider country specific article codes
70 0.89 5 ml - 6 1x - 4160290 with suffix „-07“
50 0.89 5 ml - 8 1x - 4160517 ** All catheters are made of PUR, with soft tip and
50 0.89 5 ml - 8 1x - 4160320 length marking
70 0.89 5 ml - 8 1x - 4160789 *** All guidewires are made of Nitinol, with one soft
50 0.89 5 ml 1x 8 1x 2x 4166159 J tip and one soft straight tip, printed with length
50 0.89 5 ml 1x 8 1x 2x 4161211 markings and ECG marked

70 0.89 5 ml 1x 8 1x 2x 4161319
50 0.89 5 ml 1x 8 1x 3x 4162153
50 0.89 5 ml 1x 8 1x 3x 4163214
70 0.89 5 ml 1x 8 1x 3x 4163311
50 0.89 5 ml 1x 9 1x 4x 4167767
50 0.89 5 ml 1x 9 1x 4x 4167775
70 0.89 5 ml 1x 9 1x 4x 4167783
50 0.89 5 ml 1x 12 1x 5x 4166841
50 0.89 5 ml 1x 12 1x 5x 4166868

Guidewire *** Other Accessories


Length Ø Syringe Scalpel Dilator Connection Needle Free Article No.*
(cm) (mm) (Fr) cable ECG Connector Safsite® (REF)
50 0.63 5 ml - 5 1x - 4160185
50 0.63 5 ml - 5 1x - 4160207
50 0.89 5 ml - 6 1x - 4160223
50 0.89 5 ml - 6 1x - 4160258
70 0.89 5 ml - 6 1x - 4160282
50 0.89 5 ml - 8 1x - 4160509
50 0.89 5 ml - 8 1x - 4160304
70 0.89 5 ml - 8 1x - 4160762
50 0.89 5 ml 1x 8 1x 2x 4164158
50 0.89 5 ml 1x 8 1x 2x 4167385
70 0.89 5 ml 1x 8 1x 2x 4167394
50 0.89 5 ml 1x 8 1x 3x 4161159
50 0.89 5 ml 1x 8 1x 3x 4167408
70 0.89 5 ml 1x 8 1x 3x 4163306
50 0.89 5 ml 1x 12 1x 5x 4166852

13
Product Specifications

Certofix® Protect  
Name Catheter** Introducer Needle
Certofix® Lumen Size Length Lumen Ø (Gauge) min. Flow Rate (ml/min) Filling Volume (ml) Type Gauge
Protect (Fr) (cm) D/M1/M2/M3/P D/M1/M2/M3/P D/M1/M2/M3/P
Mono V 320 P 1 5 20 16 52 0.415 V 18
Mono V 330 P 1 5 30 16 40 0.510 V 18
Mono V 420 P 1 6 20 14 80 0.535 V 18
Mono V 430 P 1 6 30 14 75 0.690 V 18
Duo V 715 P 2 7 15 16/16 60/50 0.400/0.335 V 18
Duo V 720 P 2 7 20 16/16 55/45 0.455/0.380 V 18
Duo V 730 P 2 7 30 16/16 52/37 0.570/0.470 V 18
Duo HF V 720 P 2 7 20 14/18 100/27 0.555/0.276 V 18
Trio V 715 P 3 7 15 16/18/18 50/28/28 0.340/0.205/0.195 V 18
Trio V 720 P 3 7 20 16/18/18 46/22/22 0.380/0.215/0.205 V 18
Trio V 730 P 3 7 30 16/18/18 38/18/18 0.460/0.240/0.230 V 18
Trio HF V 1220 P 3 12 20 16/12/12 55/165/165 0.470/1.410/1.401 V 18
Quattro V 815 P 4 8 15 14/18/18/16 50/20/20/50 0.435/0.205/0.260/0.255 V 18
Quattro V 820 P 4 8 20 14/18/18/16 40/15/15/40 0.500/0.215/0.280/0.295 V 18
Quattro V 830 P 4 8 30 14/18/18/16 35/10/10/35 0.635/0.240/0.325/0.380 V 18
Quinto V 1220 P 5 12 20 16/18/18/18/12 55/28/28/28/185 0.515/0.300/0.300/0.340/1.105 V 18

Certofix® High Flow


Name Catheter** Introducer Needle
Certofix® Lumen Size Length Lumen Ø (Gauge) min. Flow Rate (ml/min) Filling Volume (ml) Type Gauge
High Flow (Fr) (cm) D/M/P D/M/P D/M/P
Duo HF V 715 2 7 15 14/18 105/42 0.480/0.245 V 18
Duo HF V 720 2 7 20 14/18 100/27 0.555/0.275 V 18
Duo HF S 720 2 7 20 14/18 100/27 0.555/0.275 S 18
Duo HF V 920 2 9 20 13/13 95/120 1.220/1.105 V 18
Duo HF V 1215 2 12 15 11/11 260/260 1.425/1.335 V 18
Duo HF V 1220 2 12 20 11/11 230/230 1.580/1.490 V 18
Trio HF V 1215 3 12 15 16/12/12 65/225/225 0.415/1.260/1.170 V 18
Trio HF S 1215 3 12 15 16/12/12 65/225/225 0.415/1.260/1.170 S 18
Trio HF V 1220 3 12 20 16/12/12 55/165/165 0.470/1.410/1.400 V 18
Trio HF S 1220 3 12 20 16/12/12 55/165/165 0.470/1.410/1.400 S 18
Protect Duo HF V
2 7 20 14/18 100/27 0.555/0.276 V 18
720 P
Protect Trio HF V
3 12 20 16/12/12 55/165/165 0.470/1.410/1.401 V 18
1220 P

14
Additional Information Certofix® Protect
Guidewire *** Other Accessories
V: Valve Needle
Length Ø Syringe Scalpel Dilator Connection Needle Free Article No.* D: distal, M: middle, P: proximal
(cm) (mm) (Fr) cable ECG Connector Safsite® (REF)
50 0.89 5 ml - 6 1x - 4160266P The sales unit of Certofix® Protect Sets is 10 pieces / box
70 0.89 5 ml - 6 1x - 4160290P * Note: Please consider country specific article codes
50 0.89 5 ml - 8 1x - 4160320P with suffix „-07“
70 0.89 5 ml - 8 1x - 4160789P ** The base material of the central venous catheter
50 0.89 5 ml 1x 8 1x 2x 4166159P consists of polyurethane. All lumen, including the hub
50 0.89 5 ml 1x 8 1x 2x 4161211P and the outer surface of the catheter are coated with a
70 0.89 5 ml 1x 8 1x 2x 4161319P long-chain high-molecular polymer-based methacry-
late. This modified surface is non-covalently linked to
50 0.89 5 ml 1x 8 1x 2x 4168534P
the polyurethane catheter material and is embedded
50 0.89 5 ml 1x 8 1x 3x 4162153P
and bonded to the base material of the catheter.
50 0.89 5 ml 1x 8 1x 3x 4163214P
The polymer‘s chemically modified side groups are
70 0.89 5 ml 1x 8 1x 3x 4163311P freely accessible on the catheter surface. They contain
50 0.89 5 ml 1x 12 1x 3x 4160622P hydrophilic side groups such as polyethylene glycol and
50 0.89 5 ml 1x 9 1x 4x 4167767P antiseptic biguanide side groups. The side chain which
50 0.89 5 ml 1x 9 1x 4x 4167775P is derived from a polymeric biguanide is chemically
70 0.89 5 ml 1x 9 1x 4x 4167783P similar to the antiseptic polihexanide.

50 0.89 5 ml 1x 12 1x 5x 4166868P *** All guidewires are made of Nitinol, with one soft J tip
and one soft straight tip, printed with length markings
and ECG marked

Additional Information Certofix® High Flow


Guidewire *** Other Accessories
V: Valve Needle, S: Seldinger Needle
Length Ø Syringe Scalpel Dilator Connection Needle Free Article No.* D: distal, M: middle, P: proximal
(cm) (mm) (Fr) cable ECG Connector Safsite® (REF)
50 0.89 5 ml 1x 8 1x 2x 4168518 The sales unit of Certofix® High Flow Sets is 10 pieces / box
50 0.89 5 ml 1x 8 1x 2x 4168534 * Note: Please consider country specific article codes
50 0.89 5 ml 1x 8 1x 2x 4168528 with suffix „-07“
50 0.89 5 ml 1x 9 1x 2x 4167511 ** All catheters are made of PUR, with soft tip and
50 0.89 5 ml 1x 12 1x 2x 4167538 length marking
50 0.89 5 ml 1x 12 1x 2x 4167546 *** All guidewires are made of Nitinol, with one soft J tip
50 0.89 5 ml 1x 12 1x 3x 4160614 and one soft straight tip, printed with length markings
50 0.89 5 ml 1x 12 1x 3x 4160578 and ECG marked
50 0.89 5 ml 1x 12 1x 3x 4160622
50 0.89 5 ml 1x 12 1x 3x 4160586

50 0.89 5 ml 1x 8 1x 2x 4168534P

50 0.89 5 ml 1x 12 1x 3x 4160622P

15
Product Specifications

Certofix® Safety
Name Catheter** Introducer Needle
Certofix® Lumen Size (Fr) Length Lumen Ø (Gauge) min. Flow Rate (ml/min) Filling Volume (ml) Type Gauge
Safety (cm) D/M1/M2/M3/P D/M1/M2/M3/P D/M1/M2/M3/P
Mono S 320 1 5 20 16 52 0.415 Safety 18
Mono S 330 1 5 30 16 40 0.510 Safety 18
Duo S 720 2 7 20 16/16 55/45 0.455/0.380 Safety 18
Duo S 730 2 7 30 16/16 52/37 0.570/0.470 Safety 18
Trio S 720 3 7 20 16/18/18 46/22/22 0.380/0.215/0.205 Safety 18
Trio S 730 3 7 30 16/18/18 38/18/18 0.460/0.240/0.230 Safety 18
Quattro S 820 4 8 20 14/18/18/16 40/15/15/40 0.500/0.215/0.280/0.295 Safety 18
Quinto S 1220 5 12 20 16/18/18/18/12 55/28/28/28/185 0.515/0.300/0.300/0.340/1.105 Safety 18

Certofix® Paed
Name Catheter*** Introducer Needle
Certofix® Lumen Size (Fr) Length Lumen Ø (Gauge) min. Flow Rate (ml/min) Filling Volume (ml) Type Gauge
Paed (cm) D/M/P D/M/P D/M/P

Mono S 110 1 3 10 22 15 0.100 S 21

Duo S 408 2 4 8 22/22 18/18 0.235/0.205 S 21


Duo S 413 2 4 13 22/22 10/10 0.255/0.225 S 21
Duo S 420 2 4 20 22/22 9/9 0.275/0.250 S 21
Duo S 508 2 5 8 18/20 30/15 0.250/0.205 S 21
Duo S 513 2 5 13 18/20 22/11 0.270/0.225 S 21
Duo S 520 2 5 20 18/20 18/9 0.300/0.250 S 21
Trio S 508 3 5 8 20/22/22 30/15/15 0.235/0.185/0.180 S 21
Trio S 513 3 5 13 20/22/22 29/10/10 0.260/0.200/0.195 S 21
Trio S 520 3 5 20 20/22/22 18/6/6 0.290/0.215/0.210 S 21

16
Additional Information Certofix® Safety
Guidewire *** Other Accessories
D: distal, M: middle, P: proximal
Length Ø Syringe Scalpel Dilator Connection Needle Free Article No.*
(cm) (mm) (Fr) cable ECG Connector Safsite® (REF) The sales unit of Certofix® Safety Sets is 10 pieces / box
50 0.89 5 ml Safety 6 1x - 4160258S
* Note: Please consider country specific article codes
70 0.89 5 ml Safety 6 1x - 4160282S with suffix „-07“
50 0.89 5 ml Safety 8 1x 2x 4167385S ** All catheters are made of PUR, with soft tip and
70 0.89 5 ml Safety 8 1x 2x 4167394S length marking
50 0.89 5 ml Safety 8 1x 3x 4167408S *** All guidewires are made of Nitinol, with one soft J tip
70 0.89 5 ml Safety 8 1x 3x 4163306S and one soft straight tip, printed with length markings
50 0.89 5 ml Safety 9 1x 4x 4167775S and ECG marked
50 0.89 5 ml Safety 12 1x 5x 4166852S

Additional Information Certofix® Paed


Guidewire **** Other Accessories
S: Seldinger Needle
Length Ø Syringe Scalpel Dilator Connection Needle Free Statlock Article D: distal, M: middle, P: proximal
(cm) (mm) (Fr) cable ECG Connector Safsite® catheter No.*
fixation (REF)
The sales unit of Certofix® Paed Sets is 10 pieces / box
(instead of Safsite®)
25 0.46 3 ml 1x - 1x 1x Infusion extension line 1x 4160177** * Note: Please consider country specific article codes
1x Discofix® 3-way stopcock with suffix „-07“
50 0.46 5 ml 1x 5 1x 2x 1x 4166906 ** N
 ote: Please consider country specific article codes
50 0.46 5 ml 1x 5 1x 2x 1x 4166922 with suffix „-01“ or „-04“
50 0.46 5 ml 1x 5 1x 2x 1x 4166949 *** All catheters are made of PUR, with soft tip and
50 0.46 5 ml 1x 6 1x 2x 1x 4167112 length marking
50 0.46 5 ml 1x 6 1x 2x 1x 4167139 **** All guidewires are made of Nitinol, with one soft
50 0.46 5 ml 1x 6 1x 2x 1x 4167155 J tip and one soft straight tip, printed with ength
50 0.46 5 ml 1x 6 1x 3x 1x 4167228 markings and ECG marked

50 0.46 5 ml 1x 6 1x 3x 1x 4167244
50 0.46 5 ml 1x 6 1x 3x 1x 4167260

17
Product Specifications

Certofix® Econoline
Name Catheter** Introducer Needle
Certofix® Lumen Size (Fr) Length Lumen Ø (Gauge) min. Flow Rate (ml/min) Filling Volume (ml) Type Gauge
Econoline (cm) D/M/P D/M/P D/M/P
Mono 215 1 4 15 18 16 0.175 S 20
Mono 220 1 4 20 18 13 0.200 S 20
Mono 315 1 5 15 16 55 0.300 S 18
Mono 320 1 5 20 16 45 0.350 S 18
Mono 330 1 5 30 16 40 0.445 S 18
Mono 415 1 6 15 14 95 0.470 S 18
Mono 420 1 6 20 14 85 0.550 S 18
Mono 430 1 6 30 14 75 0.700 S 18
Duo 715 2 7 15 16/16 60/50 0.400/0.335 S 18
Duo 720 2 7 20 16/16 55/45 0.455/0.380 S 18
Duo 730 2 7 30 16/16 52/37 0.570/0.470 S 18
Trio 715 3 7 15 16/18/18 50/28/28 0.340/0.205/0.195 S 18
Trio 720 3 7 20 16/18/18 46/22/22 0.380/0.215/0.205 S 18
Trio 730 3 7 30 16/18/18 38/18/18 0.460/0.240/0.230 S 18

ACCESSORIES FOR CATHETER TIP POSITIONING WITH ECG

Accessories Description Article No.*

Certodyn Universal® Adapter

Electronic switch box (for adults) 4150228

Certodyn Universal® Adapter Paed

Electronic switch box (for paediatric patient) 4150724

Alphacard®

Syringe with electrode to Certodyn® universal adapter U1800401

18
Additional Information Certofix® Econoline
Guidewire*** Other Accessories
S: Seldinger Needle
Length Ø IN- Dilator Article No.* D: distal, M: middle, P: proximal
(cm) (mm) Stopper (Fr) (REF)
50 0.63 1x 5 4160185E The sales unit of Certofix® Econoline Sets is 10 pieces / box
50 0.63 1x 5 4160207E * Note: Please consider country specific article codes
50 0.89 1x 6 4160223E with suffix „-07“
50 0.89 1x 6 4160258E ** All catheters are made of PUR, with soft tip and length
70 0.89 1x 6 4160282E marking
50 0.89 1x 8 4160509E *** All guidewires are made of Nitinol, with one soft J tip
50 0.89 1x 8 4160304E and one soft straight tip, printed with length markings
and ECG marked
70 0.89 1x 8 4160762E
50 0.89 2x 8 4164156E
50 0.89 2x 8 4162200E
70 0.89 2x 8 4162307E
50 0.89 3x 8 4161157E
50 0.89 3x 8 4163206E
70 0.89 3x 8 4163303E

19
Literature

1. The Joint Commission. Preventing Central Line–Associated Bloodstream Infec- 9.  Brunke J, et al. Quantitative comparision of the antimicrobial efficiency
tions: A Global Challenge, a Global Perspective. Oak Brook, IL: Joint Commission of leaching versus nonleaching polymer materials. Macromol.
Resources, May 2012. http://www.PreventingCLABSIs.pdf. Biosci. 2016, 16, 647-654
2. https://ecdc.europa.eu/en/publications-data/directory-guidance-prevention- 10. Hanna H, et al. Comparative in vitro efficacies and antimicrobial durabilities
and-control/healthcare-associated-infections-1 of novel antimicrobial central venous catheters. Antimicrob Agents Chemother.
3. Yousif A, Jamal MA, Raad I. Biofilm-based central line-associated bloodstream 2006 Oct;50(10):3283-8
infections. Adv Exp Med Biol. 2015; 830:157-79 11. Y asukawa T, Fujita Y, Sari A. Antimicrobialimpregnated central venous
4. Elliott TSJ. The pathogenesis and prevention of intravascular catheter-related catheters. N Engl J Med. 1999 Jun 3; 340(22):1762
infections. In: Hamilton H, Bodenham AR. Central venous catheters. 12. Raad I, Hanna H, Jiang Y, Dvorak T, Reitzel R, Chaiban G, Sherertz R, Hachem R.
Chichester [u.a.]: Wiley-Blackwell 2009; 206-209 Comparative activities of daptomycin, linezolid, and tigecycline against
5. McLaws ML, Burrell AR. Zero risk for central line-associated bloodstream catheter-related methicillinresistant Staphylococcus bacteremic isolates em-
infection: are we there yet? Crit Care Med. 2012 Feb; 40(2):388-93 bedded in biofilm. Antimicrob Agents Chemother. 2007 May; 51(5):1656-60
6. Krikava I, et al. The efficacy of a non-leaching antibacterial central venous 13. Tambe SM, Sampath L, Modak SM. In vitro evaluation of the risk of deve-
catheter – a prospective, randomized, double-blind study. Biomed Pap Med loping bacterial resistance to antiseptics and antibiotics used in medical
Fac Univ Palacky Olomouc Czech Repub. 2019. [Epub ahead of print] devices. J Antimicrob Chemother 2001; 47: 589-98
7. Richards GA, et al. Investigation of biofilm formation on a charged intravenous 14. Sampath LA, Tambe SM, Modak SM. In vitro and in vivo efficacy of catheters
catheter relative to that on a similar but uncharged catheter impregnated with antiseptics or antibiotics: evaluation of the risk of bacterial
8. Brunke J, Riemann T, Roschke I, 30 days antimicrobial efficacy of non-leaching resistance to the antimicrobials in the catheters. Infect Control Hosp Epidemiol
central venous catheters (Poster 063), Critical Care 2016, Volume 20 Suppl 2. 2001; 22: 640-6

B. Braun Melsungen AG | Hospital Care | 34209 Melsungen | Germany


Tel. +49 5661 71-0 | www.bbraun.com

Date of last revision: 08.2021