0% found this document useful (0 votes)
210 views3 pages

DTC Table: Caution: Be Sure To Perform Before Starting Diagnosis

This document provides a table of diagnostic trouble codes (DTCs) for the air conditioning system of a Suzuki vehicle. It lists various DTC numbers, the corresponding faulty component, and how the DTC is indicated by flashing patterns on the "REC" and "FRE" indicator lamps on the HVAC control module. It also describes how multiple DTCs will be displayed sequentially based on their assigned display time, with shorter codes waiting for longer ones to finish displaying first.

Uploaded by

Bumbu Permata
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
210 views3 pages

DTC Table: Caution: Be Sure To Perform Before Starting Diagnosis

This document provides a table of diagnostic trouble codes (DTCs) for the air conditioning system of a Suzuki vehicle. It lists various DTC numbers, the corresponding faulty component, and how the DTC is indicated by flashing patterns on the "REC" and "FRE" indicator lamps on the HVAC control module. It also describes how multiple DTCs will be displayed sequentially based on their assigned display time, with shorter codes waiting for longer ones to finish displaying first.

Uploaded by

Bumbu Permata
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

S6JB0A7204004 Page 1 of 3

7B
DTC Table
CAUTION:
Be sure to perform Air Conditioning System Check before starting diagnosis.

DTC No. DTC (indicated on HVAC Priority Diagnosis


(displayed on control module) of
SUZUKI scan display
Indicated Indicated
tool)
by “REC” by “FRE”
indicator indicator
lamp lamp
Outside air temperature sensor
B1562 1 4 1 Data error
and/or its circuit malfunction
1 2 Inside air temperature sensor and/or Open
B1502 2
2 3 its circuit malfunction Short
1 4 Evaporator temperature sensor Open
B1503 3
2 5 and/or its circuit malfunction Short
1 29 Sunload sensor and/or its circuit Open
B1504 4
2 6 malfunction Short
Engine coolant temperature sensor
B1561 5 4 7 Data error
and/or its circuit malfunction
1 8 Temperature control actuator Open
B1511 (position sensor) and/or its circuit
6 2 9 malfunction Short
Temperature control actuator and/or
B1513 3 10 Lock detect
its circuit malfunction
1 11 Air flow control actuator (position Open
B1512
2 12 sensor) and/or its circuit malfunction Short
7
Air flow control actuator and/or its
B1514 3 13 Lock detect
circuit malfunction
1 14 Air intake control actuator (position Open
B1530
2 15 sensor) and/or its circuit malfunction Short
8
Air intake control actuator and/or its
B1531 3 16 Lock detect
circuit malfunction
1 17 Open
B1551
2 18 Serial communication circuit Short
9
malfunction
B1552 4 19 Data error
CAN communication circuit
B1553 10 4 20 Data error
malfunction
Wheel speed sensor and/or its circuit
B1557 11 4 21 Data error
malfunction
Camshaft position (CMP) sensor
B1556 12 4 22 Data error
and/or its circuit malfunction
A/C refrigerant pressure sensor
B1563 4 23 Data error
and/or its circuit malfunction
13 Refrigerant
A/C refrigerant pressure sensor
B1546 5 24 pressure
malfunction
malfunction
1 25 Open
B1520 15 Temperature selector malfunction
2 26 Short
1 27 Open
B1521 16 Blower speed selector malfunction
2 28 Short

file:///C:/Users/matt/Desktop/GRAND_VITARA/Xml/S6JB0A/navi/top.html 26/11/2019
S6JB0A7204004 Page 2 of 3

— See NOTE below — Normal —

NOTE:
When no abnormality is detected, “FRE” indicator lamp and “REC” indicator lamp
repeat cycle of ON for 2 seconds and OFF for 1 second.

Example of “REC” Indicator Lamp Flashing Pattern

[A]: B1503 (No.3) (b): “REC” indicator lamp “OFF” (e): 2.0 (sec.)

[B]: B1556 (No.12) (c): Time (sec.) (f): 1.5 (sec.)

(a): “REC” indicator lamp “ON” (d): 0.5 (sec.)

Example of “FRE” Indicator Lamp Flashing Pattern

[A]: Open (b): “FRE” indicator lamp “OFF” (e): 2.0 (sec.)

file:///C:/Users/matt/Desktop/GRAND_VITARA/Xml/S6JB0A/navi/top.html 26/11/2019
S6JB0A7204004 Page 3 of 3

[B]: Short (c): Time (sec.)

(a): “FRE” indicator lamp “ON” (d): 0.5 (sec.)

NOTE:
Locked actuator, data error and refrigerant pressure malfunction are indicated
by flashing pattern of “FRE” indicator lamp specified for each of them.

Display Timing of “FRE” Indicator Lamp and “REC” Indicator


Lamp
Code with short display time waits until display of code with long display time is over.

[A]: B1520 (15 – 1) (a): “REC” indicator flashing pattern

[B]: B1562 (1 – 4) (b): “FRE” indicator flashing pattern

file:///C:/Users/matt/Desktop/GRAND_VITARA/Xml/S6JB0A/navi/top.html 26/11/2019

You might also like