Fisa Tehnica Centrala Adresabila de Alarmare La Incendiu UTC Fire Security FP1216C-45 2-4 Bucle 128 Adrese-Bucla 16 Zone

This document provides specifications for the FP1216C-45 fire panel, including that it is an addressable fire panel with 2-4 loops and 16 zone LED indicators. It has a backlit LCD display and extensive features for configuration, maintenance, and networking. The panel offers quick setup, redundant wiring options, and user-friendly zone descriptions. It also provides maintenance friendly features like real-time diagnostics and contamination warnings.

Uploaded by

Marius
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
136 views2 pages

Fisa Tehnica Centrala Adresabila de Alarmare La Incendiu UTC Fire Security FP1216C-45 2-4 Bucle 128 Adrese-Bucla 16 Zone

This document provides specifications for the FP1216C-45 fire panel, including that it is an addressable fire panel with 2-4 loops and 16 zone LED indicators. It has a backlit LCD display and extensive features for configuration, maintenance, and networking. The panel offers quick setup, redundant wiring options, and user-friendly zone descriptions. It also provides maintenance friendly features like real-time diagnostics and contamination warnings.

Uploaded by

Marius
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

FP1216C-45

1200 Series - Addressable Fire Panel with 2-4 Loops 16 Zone LED's - Romanian

General
The FP1216C is a versatile addressable fire panel
supplied with 2 class-A loops. In addition to a generous
backlit LCD display, it provides LEDs for indicating both
fire and fault conditions with text descriptions for 16 fire
zones on the front panel user interface. The panel may
be upgraded with an additional 2 class-A loops, full inter-
panel networking facilities on both copper or fibre, as
well as with a LON network bus that supports the Aritech
LON700 devices and repeaters, amongst others. The
FP1216C provides extensive maintenance features,
boasts powerful I/O programming and supports both Details
Aritech 2000 and 900 series protocols.
Configuration, maintenance and graphic PC
Installer Friendly software support
Up to 128 device addresses per loop
The FP1216C offers multiple auto-configuration options Full interpanel network options
with extensive auto detection facilities facilitating quick Full range of repeaters and LON700 devices
initial setup even for large systems. Multiple repeaters in including Dutch and Scandinavian fire brigade
various formats may be connected over a 2-wire network panels, and Scandinavian alarm delay units
with both class-A and B operating modes, whilst up to 31 Networkable "black box" panels
fire panels may be networked together for large Power supply for 72-hour autonomy
applications. Default start-up and service modes
Programmable service reminders, on-line
User friendly diagnostics and statistics
Maintenance warnings and soak testing facilties
In addition to the comprehensive information LEDs, the One-man maintenance
panel's large LCD display allows for every device in the Floating background and drift compenstation
system to be described with up to 80 characters of Programmable day/night functionality
descriptive text, as well as 40 characters for zone Coincidence within and between zones
descriptions. Complete statistics and graphics Timed and manual zone control
indications for every device are available. Several I/O programming with Boolean functions
mechanisms for preventing false alarms, including Scandinavian variants with Scandinavian firemans
floating background with automatic compensation, key available
double knock and coincidence mode within and between EN54 and CPD certified
zones, as well as soak test facilities allow the user
complete piece of mind.

Maintenance friendly
Maintenance warnings are available whenever detectors
reach contamination levels. Together with real time
diagnostics and statistics per sensor, the FP1216C offers
a wealth of in-depth information locally or by remote
connections.
FP1216C-45
1200 Series - Addressable Fire Panel with 2-4 Loops 16 Zone LED's - Romanian

Technical Specifications
Physical
Colour RAL9016 Traffic White
Dimensions (h x w x d) 445 x 445 x 120 mm
Weight (no batteries) 9 kg

Environmental
IP rating IP54
Operating temperature -5°C to +40°C
Storage temperature -20°C to +60°C

Standards & Regulation


Certification EN54-2, EN54-4

Power supply
Mains supply 230 VAC (+10%, -15%), 47-63 Hz
Power requirement 200 VA
Operating voltage 21 to 28 VDC
Operating current 200 mA @ 24 VDC
Alarm current < 240 mA @ 24 VDC
Auxiliary supply (24 VDC) 9 to 28 VDC @ 1 A (max)
Auxiliary supply (5 VDC) 5 VDC (±0.1V) 75 mA (max)
Battery charger 27.3 VDC at 20°C, 36 mV/°C
Batteries 2 x 12 V (7Ah to 45 Ah)

Loop specifications
Loops per panel 4 (Class A)/8 (Class B)
Loop current < 500 mA
Addresses per loop <128 *
Loop cable length < 2 km
Loop cable specification Ø 1 mm, 300 nF/km, 100 ohm

Inputs and outputs


Relays 4 (2A @ 24 VDC - 60W)
Supervised Relays 4 (24 VDC, 30 ohm, 120 nF, 500 m)
Inputs (Opto Isolated) 4 (15 VAC/0 to 28 VDC)
Inputs (Supervision 4
selectable)
Zone indicators per panel 16 (fire & fault)

As a company of innovation, UTC Technologies reserves the right to change product


specifications without notice. For the latest product specifations, visit UTC
Technologies online or contact your sales representative.