0% found this document useful (0 votes)
49 views5 pages

Improvement of Power Quality Using Series Active Power Filter (Sapf)

Uploaded by

Kranthi.B
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views5 pages

Improvement of Power Quality Using Series Active Power Filter (Sapf)

Uploaded by

Kranthi.B
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

2020 IEEE International Students' Conference on Electrical, Electronics and Computer Science.

IMPROVEMENT OF POWER QUALITY


USING SERIES ACTIVE POWER
FILTER(SAPF)
2020 IEEE International Students' Conference on Electrical,Electronics and Computer Science (SCEECS) 978-1-7281-4862-5/20/$31.00 ©2020 IEEE 10.1109/SCEECS48394.2020.151

Konala Kalyan Markapuram Srinivasa Rao Dr. Suresh Gawre


Electrical Department ENERGY CENTER Electrical Department
MANIT, PG Student MANIT, PG Student MANIT, Assistant Professor
Bhopal, India Bhopal, India Bhopal, India
[email protected] [email protected] [email protected]

ABSTRACT: -Modern power electronics devices like active continuously through the line distribution [3].
power filter and comprehensive simulation study of Relay
gives the idea of power quality. Generally, in electrical The Parallel Active Power filter (PAPF) is right to
parallel circuits voltage is constant and current is variable compensate harmonic current source, series active
parameter, so by using parallel active filter provided variable
currents in system and mainly series active filters are used
filter is proper in the circumstances for recompose the
for voltage and power quality improvement to the system and harmonic voltage source and this has the enough
harmonic content on load voltage reduces. In this paper FFT condenser term in the dc connection of rectifier.
analysis are done with help of series active power filter. The Almost steady state dc current move steadily to the dc
results show that proper tune active power filter provides connection of rectifier because of DC smoothing
best outputs for the imaginary power compensation and inductor is enough range [1]. Some control algorithm
power factor Developments. techniques is relevant by an abstract idea of
generalized p-q theory [4]. Section II describes control
Keywords: - Power quality, Passive filters, UPQC, algorithm for SAPF.
Harmonics, Non-Linear load.
II. SYSTEM CONFIGURATION
I. INTRODUCTION
Harmonics and Reactive Power is reduced by
employing an PAPF, by an idea of generalized p-q
In earlier days around 20th century there are so
theory. To Calculate these limitations, a new
many draw backs for passive filter, so we can reduce
developed p-q theory is derived. Whenever gain is
these draw backs by study on active power filter. The
multiplied to the system to develop compensating
Active filter costing a lot of money than the Passive
voltage then it is also becoming additional
filter, but these are having superior position, so it can
disadvantage to generalized p-q theory and this p-q
alternatively remove the broadband harmonics at the
theory is controlled by the value of current, so no need
source side [1].compensating current is introduce
to be multiplied gain to the system. Some attempts are
through PAF and from other side compensating
needed to attain the current by using instantaneous
voltage is introduce through SAPF by through a
power and reactive power [1].
combined parallel filter and series filter and through
transformer [1].
A Voltage source inverter (VSI) is nearly
equal as the SAPF [1]. To neutralize the voltage
The use of semiconductors where we can take in
harmonics on load side we have to introduce
some switching equipment’s like thyristors, diodes and
compensating voltage to the supply. So, by this APF
rectifiers had randomly increased. So, by these
produces the distortions which is opposite to the source
switching equipment’s and other nonlinear loads the
harmonics [5].
power quality decreases gradually. whenever there is
greater in nonlinear loads, we require additional
P= , ,0 ∗ , ,0 (1.0)
amount of complex steps to overcome the power
= + + (1.1)
quality degradation [1], such as harmonic increase
compensation currents, Load is getting average active The Eq 1.2 gives the Instantaneous Active power at
power by the sinusoidal source current. load side.

The APF have more desirable performances when III. CONTROL STRATEGY
compare to other strategies [2]. Whenever introducing On this control strategy major have sine wave
a compensating voltage harmonic and compensating generator and producing its switching signals. The
current harmonics and whenever UPQC meets the two citation voltage depends on two parameters, those are
voltages and currents then at that time we can cancels initial crest value of the basic term of the source
the interfering components those which are move voltage and unit sine vectors in phase to source
voltages [7]. This Citation signals are produced by

978-1-7281-4862-5/20/$31.00 ©2020 IEEE

Authorized licensed use limited to: University of Warwick. Downloaded on May 24,2020 at 01:42:15 UTC from IEEE Xplore. Restrictions apply.
through at most sine wave generator and its constant controller for producing the switching signals for the
amplitude to produce signals to it. The use of PLL inverter. By providing series transformers, variable
circuits is to producing major voltages to it. This voltage inserted due to switching operation the
way ciliated voltage is produced it has sinusoidal produced output voltage has nature is sinusoidal
and regardless of mains. This citation voltage and load voltage and load voltage harmonics reduced
identified load voltage are specified to hysteresis [1].

IV. MATLAB SIMULINK MODEL

Fig .1 MATLAB design for series active power filter

The MATLAB simulation is shown in Fig .1.in compare to the normal load voltage then above
this we are using mostly two variables there are switch is turn on and below switch is turn off [9]. To
reference voltage and load voltage [6]. The fixed generate load voltage as purely sinusoidal we need
voltages are estimated with the actual load voltage, to connect to output of SAPF to supply lines by
then by this estimate MATLAB gets some interrupt. using series transformer then harmonic voltage is
when interrupt happen, the interrupt signal sends to consumed by filter then harmonics are reduced [10-
hysteresis controller for produces firing pulses, these 14].
firing pulses are used for switching of the inverter in
the system, by considering both reference voltage
and load voltage the switches are turned on and
turned off [8]. The fixed voltage is less value when

SCEECS 2020

Authorized licensed use limited to: University of Warwick. Downloaded on May 24,2020 at 01:42:15 UTC from IEEE Xplore. Restrictions apply.
V. RESULTS

Fig. 2 Source voltages with harmonics

Before After

Fig.3. Before and after compensation of Load voltage

Fig. 3. represents the load voltage where before and after compensation by series APF, As the pulse is generated
at 0.91 sec, harmonic component in the load voltage decrease notified to it.

Fig:4 FFT analysis for voltage source containing harmonics

SCEECS 2020

Authorized licensed use limited to: University of Warwick. Downloaded on May 24,2020 at 01:42:15 UTC from IEEE Xplore. Restrictions apply.
Fig:5 FFT analysis for load voltage without harmonics

The figure .4. And fig .5. Represents the Fast Fourier REFERENCES
Transform (FFT) analysis of the source voltage and
the load voltage of the SAPF respectively. This [1] Ashish Srivastava, Ravi Dixit, Ashish Kumar Pandey;
results shows that THD level Is reduced and system "Method of Improving Voltage Quality Using Modern
performance increased. Power Electronics"; IJETAE; (ISSN 2250-2459, ISO
9001:2008 Certified Journal, Volume 3, Issue 5, May
2013).
ACKNOWLEDGMENT [2] Sango Ravindra, Dr.V.C.Veera Reddy,
Dr.S.Sivanagaraju, Devineni Gireesh Kumar; "
This paper is supported by Electrical Department, Design of Shunt Active Power Filter to eliminate the
MANIT, Bhopal. harmonic currents and to compensate the reactive
power under distorted and/or imbalanced source
voltages in steady state :;" IJSER, Volume 3, Issue 1,
CONCLUSION January-2012 ISSN 2229-5518.
[3] Ait Chihab Abderrahmane, Giri Fouad;" Nonlinear
Control of The UPQC for Grid Current and Voltage
By observing the source voltage and load Improvement:" 978-1-4673-9669-1/15/2015 IEEE.
voltage of FFT analysis results shows that [4] Nisha Tilwani, Dipesh Sharma;" Series Hybrid Filter
harmonics are reduced by using series active filter for Harmonic Compensation in Three Phase System
and observing Fast Fourier Transform (FFT) voltage using Fuzzy Logic Controller;" IJSETR, Volume 4,
analysis the percentage THD values contain in load Issue 6, June 2015.
voltage are reduces. So its conclude that series active [5] R.A.Kantaria1 , Student Member, IEEE, S.K.Joshi2 ,
filters provided better quality power improvements. K.R.Siddhapura3 :;" A Novel Technique for
Mitigation of Voltage Sag/Swell by Dynamic Voltage
Restorer (DVR) :;" 978- 1-4244-6875-1/10/2010
IEEE.

SCEECS 2020

Authorized licensed use limited to: University of Warwick. Downloaded on May 24,2020 at 01:42:15 UTC from IEEE Xplore. Restrictions apply.
[6] Felipe A. A. R. Sozinho, Kenan Hatipoglu, Yadollah
Eslami-Amirabadi, Asadollah Davari:" Hardware
Implementation Of A Microgrid Controller For
Enhancing Dynamic Voltage Stability;" 2017 Naps.
[7] Priyashree SI, Pooja A B2, Mahesh E & Vidya H A;"
Harmonie Suppression in a Non- Linear Load using
Three Phase Shunt Active Power Filter;" Conference
on PESTSE 2016.
[8] Vikash Anand, Dr.S.K.Srivastava ;" Simulation and
Performance Investigation of Unified Power Quality
Conditioner Using Hysteresis Current Control
Method IJSER, Volume 3, Issue 8, August-2012 ISSN
2229-5518.
[9] G. W. Chang, W. C. Chen;" A New Reference
Compensation Voltage Strategy for Series Active
Power Filter Control;" IEEE TRANSACTIONS ON
POWER DELIVERY, VOL. 21, NO. 3, JULY 2006.
[10] Chih Chiang Hua, Chih Wei Chuang;" Design and
Implementation of a Hybrid Series Active Power
Filter;" 0-7803-9296-5/2005 IEEE.
[11] S. K. Gawre, N. Patidar and R. K. Nema "
Application of wavelet transform in power quality: A
review" International Journal of Computer
Applications vol. 39 no. 18 pp. 30-36 February 2012.
[12] M. T. L. Gayatri and A. M. Parimi, "Power Quality
Improvement of PV-WECS Microgrid Using Active
Power Filter in Realtime," 2018 53rd International
Universities Power Engineering Conference (UPEC),
Glasgow, 2018, pp. 1-6.
[13] N. Alawadhi and A. Elnady, "Mitigation of power
quality problems using unified power quality
conditioner by an improved disturbance extraction
technique," 2017 International Conference on
Electrical and Computing Technologies and
Applications (ICECTA), Ras Al Khaimah, 2017, pp.
1-5.
[14] R. Dash, P. Paikray and S. C. Swain, "Active power
filter for harmonic mitigation in a distributed power
generation system," 2017 Innovations in Power and
Advanced Computing Technologies (i-PACT),
Vellore, 2017, pp. 1-6.

SCEECS 2020

Authorized licensed use limited to: University of Warwick. Downloaded on May 24,2020 at 01:42:15 UTC from IEEE Xplore. Restrictions apply.

You might also like