0% found this document useful (0 votes)
32 views1 page

ATLUGB

The document discusses flow meters that are suitable for use in various industries to measure liquid, gas, vapor, and steam. They can measure medium temperatures from -40 to 350 degrees Celsius and have an intrinsic error of 0.5-2.5%. The flow meters output analog signals or pulse signals and have tube diameters ranging from 15 to 3000 mm.

Uploaded by

Mohamed Elbanadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views1 page

ATLUGB

The document discusses flow meters that are suitable for use in various industries to measure liquid, gas, vapor, and steam. They can measure medium temperatures from -40 to 350 degrees Celsius and have an intrinsic error of 0.5-2.5%. The flow meters output analog signals or pulse signals and have tube diameters ranging from 15 to 3000 mm.

Uploaded by

Mohamed Elbanadi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Flow Meters

ATLUGB/E series are suitable for oil,chemical industry,metallurgy,heating power,spinning,


papermaking ,etc.
Be use of control: overheating vapor, saturation vapor, compressed air, ordinary air(oxygen, nitrogen, hydr
ogen,natural gas, coal gas,etc),water and liquid (water, petrol , alcohol, benzene ,etc.)

Precision :liquid +-1.0%FS


Gas and vapor: +-1.0%FS or +-1.5%FS
Range of medium temperature:-25centigrade to +350C
Ambient temperature: -25centigrade to +70C
Power :analog output:18—45 VDC
Pulse output:14—30VDC
Working pressure:< 3.2Mpa
Explode-proof : BT4/Ex ib I
Spectrum 25,40,50,80,100,150,200,250,300mm

Measuring medium Liquid, gas, vapor,steam


Normal temperature: -40° C~+80° C High temperature +280° C Maximum
Medium temperature
temperature +350° C
Medium pressure 1.0MPa, 1.6MPa, 2.5MPa… 4.0MPa
Intrinsic error Full tube type: ± 0.5%, ± 1.0%, ± 1.5% Plug-in type: ± 2.5%
Ratio of measurement
1: 10 1: 20 1: 30 1: 40
range
Range of flow speed Liquid(water): 0.25M/S~9.5M/S Gas: 4M/S~78M/S Vapor: 3M/S~78M/S
Full tube type: 15, 25, (32), 40, 50, (65), 80, 100, (125), 150, 200, 250, 300 Plug-
Caliber DN (mm)
in type: 300~3000
Reynolds number Re> 4000
Drag coefficient Full tube type: Cd ≤ 2.4, Plug-in type: Drag loss can be omitted
Degree of anti-explosion Intrinsic safety type: ia II T2~T5, Explosion-proof type: d II BT4
Ambient temperature Non anti-explosive area: -40° C~+55° C Anti-explosive area: -20° C~+55° C
DC supply +3.6V, +12V, +24V (Field data show the supply is +3.6V for 3 to 5 years)
Frequency impulse signal: 1~2600Hz, low level≤ 1V, high level≥ 5V, transmitter:
Output signal
two-wire system 4~20mA
Material 1Cr18Ni9Ti

Airtronics Sweden AB,Lavettvagen,174 59,Sudbyberg,Sweden. [email protected]