SOLENOID VALVES 12
2 4
12
2 4
10 3/2
integrated pilot operated, spool type 3
1
5 3
1
5
5/2
Series
single/dual solenoid 14
4 2
12 14
4 2
12
aluminium body, 1/4", NAMUR and THREADED style 5
1
3 5
1
3
531
Series
FEATURES
• The "NAMUR" style spool valve comes with threaded port connection and Namur
interface, while the "THREADED" style spool valve comes with threaded port
connection
• All the exhaust ports of this spool valve are connectable, providing better environmental
protection, particularly recommended for sensitive areas such as clean rooms as
well as applications in the pharmaceutical and food processing sectors
• The valve offers environmental protection against the ingress of liquids, dusts or any
other foreign matters (environmentally-protected construction)
GENERAL
Differential pressure 2 - 10 bar [1 bar = 100 kPa]
Flow (Qv at 6 bar) 1100 l/min (ANR)
Fluid (✴) Temperature Range (TS) Seal Materials (✴)
air, inert gas, filtered - 10°C to + 60°C NBR (nitrile) + PUR (polyurethane)
3/2 NC & 5/2 function Namur Version
MATERIALS IN CONTACT WITH FLUID 5 1 3
(✴) Ensure that the compatibility of the fluids in contact with the materials is verified
Body Aluminium, black anodized
End cover (spring) Glass fiber filled PA
lnternal parts Zamak, stainless steel, POM, aluminium
4 2
Seals NBR+PUR
Core and plugnut Stainless steel
Shading coil Copper 5/2 function Threaded Version
BP
SPECIFICATIONS
Operating Pressure
Flow Optional Prefix Solenoids
Pipe Orifice Differential (bar) Power Basic
Coefficient
Size Size Max. (PS) Level ATEX / IECEX / NEPSI Catalog
Kv IP65
Min. Air Ex m Number
(G) (mm) (m3/h) (l/min) AC DC AC/DC PV SC
NAMUR 3/2 NC - 5/2 - Solenoid air pilot operated - spring return (Single Solenoid)
1/4 6 0.95 15.5 2 10 10 RP - • G531C001 MS
1/4 6 0.95 15.5 2 10 10
NAMUR 3/2 NC - 5/2 - Solenoid air pilot operated (Double Solenoid)
MP
• - G531C001 MS
1/4 6 0.95 15.5 2 10 10 RP - • G531C002 MS
1/4 6 0.95 15.5 2 10 10 MP
THREADED 5/2 - Solenoid air pilot operated - spring return (Single Solenoid)
• - G531C002 MS
1/4 6 0.95 15.5 2 10 10 RP - • G531C017 MS
1/4 6 0.95 15.5 2 10 10
THREADED 5/2 - Solenoid air pilot operated (Double Solenoid)
MP
• - G531C017 MS
1/4 6 0.95 15.5 2 10 10 RP - • G531C018 MS
1/4 6 0.95 15.5 2 10 10 MP • - G531C018 MS
RP - Reduced Power, MP - Medium Power
• Available feature - Not available
2014/R1
1
APC-531-R1
SERIES 531
ORDERING EXAMPLES
SC G531 C001 MS 230V/50Hz
SC G531 C002 MS 230V/50Hz
PV G531 C017 MS 24V/DC
PV G531 C018 MS 24V/DC
Prefix Voltage
Basic Number
EXPLANATION OF TEMPERATURE RANGES OF SOLENOID VALVES
Valve temperature range The valve temperature range is determined by the selected seal material, the temperature range
for proper operation of the valve and sometimes by the fluid ( e.g. steam )
Operator ambient temperature The operator ambient temperature range is determined by the selected power level ( LP, RP, MP
range or BP ) and ATEX safety code
Total temperature range The temperature range of the complete solenoid valvle is determined by the limitations of both
temperature range above
ELECTRICAL CHARACTERISTICS
Coil insulation class F
Electrical safety IEC 335
Standard voltages DC 24V - 48V
(Other voltages and 60 Hz available on request) AC 24V - 48V - 115V - 230V/50Hz
Norminal Power Rating Operator
Electricial
Replacement Coil
Ambient
Prefix Coil Inrush Holding Hot/Cold Safety Code Enclosure
Temperature AC DC Type(1)
Option Type AC AC DC Protection
Range (TS)
(EN60529)
(VA) (VA) (W) (W) (°C) 230V / 50 Hz 24V DC
Medium Power (MP)
IECEX/ II2G Ex mb IIC T5.. T3 Gb
IECEX/ II2D Ex mb IIIC T100°C.. T200°C Db Moulded
PV - 9 5 4 3.0/4.0 -40 to +60 -(2) -(2) 02 / 04
NEPSI Ex mb IIC T5.. T3 Gb IP67
NEPSI Ex mbD 21 T100°C.. T200°C
Reduced Power (RP)
Moulded
SC CM22 6 3.5 2.5 2.5/3.0 -25 to +60 EN60730 43004886 43004869 01 / 03
IP65
(1) Refer to the dimensional drawings (2) Multiple coil kits available under ATEX, contact US
ELECTRICAL CONNECTIONS
Prefix Connection
SC Spade plug connector with cable gland DIN 43650, 11mm, industry standard B, for cables with an outer diameter from 6 to 8 mm (Type 01 / 03)
PV Moulded - in cable, standard length 2m (Type 02 / 04)
ADDITIONAL OPTIONS
• Other pipe threads are available on request
• Plug with visual indication and peak voltage suppression or with cable length of 2m, SC prefix only
(Consult ASCO NUMATICS Office)
• Moulded-in cable, standard length 2m (Type 02 /04)
INSTALLATION
• Installation/maintenance instructions are included with each valve
• The solenoid valves can be mounted in any position without affecting operation
• Spool valve supplied with two interface plates with NAMUR mating surfaces. Depending on function (NC 3/2 or 5/2),
position one of the two plates on the spool valve body before installing onto actuator
• It is necessary to connect pipes or fittings to the exhaust ports to protect the internal parts of the spool valve and its
pneumatic operator if used outside or in harsh environments (dusts, liquids, etc.)
• Dowel pin (if necessary), bolts and gaskets are standard supplied
• Threaded pipe connection identifier is: 8 = NPT (ANSI 1.20.3); G = G (ISO 228/1)
2
SERIES 531
DIMENSIONS (mm),WEIGHT (Kg)
SERIES 531 NAMUR 3/2 - 5/2 WAY
TYPE 01: Prefix SC TYPE 02: Prefix PV
IECEX/ II2G Ex mb IIC T5.. T3 Gb
Moulded IP65 IECEX/ II2D Ex mb IIIC T100°C.. T200°C Db
Reduced power NEPSI Ex mb IIC T5.. T3 Gb
IEC 335 / DIN 43650 NEPSI Ex mbD 21 T100°C.. T200°C
G531C001 MS / G531C002 MS Medium power
Epoxy moulded
EN60079 -18 and EN 61241-18
G531C001 MS / G531C002 MS
(C1): monostable 1 2 mounting holes: 5.3 mm dia. (Spotfacing: 9 mm dia., depth 5 mm)
(C2): bistable 2 One 5 mm dia. hole for dowel pin:
Port 1, 3 and 5: G 1/4 - in position A1: 3/2 NC function plate
- in position A2: 5/2 function plate
3 2 O-ring seals (supplied)
4 Interface plate
SERIES 531 THREADED 5/2 WAY
TYPE 03: Prefix SC TYPE 04: Prefix PV
Moulded IP65 IECEX/ II2G Ex mb IIC T5.. T3 Gb
Reduced power IECEX/ II2D Ex mb IIIC T100°C.. T200°C Db
IEC 335 / DIN 43650 NEPSI Ex mb IIC T5.. T3 Gb
NEPSI Ex mbD 21 T100°C.. T200°C
G531C017 MS / G531C018 MS
Medium power
Epoxy moulded
EN60079 -18 and EN 61241-18
G531C017 MS / G531C018 MS
(C1): monostable
(C2): bistable
1 3 mounting holes 4.2 mm dia.
3
SERIES 531
DIMENSIONS (mm),WEIGHT (Kg)
SERIES 531 THREADED 5/2 WAY ( MANIFOLD ASSEMBLY )
A See Chart below M 105.5
B See Chart below N 78
C 33 P 54
D 26 Q 27
E 75 R 33.5
F 2 S 28.5
G 5.5 T 17
H 20.5 U 12.5
J 112 V 10.25
K 145 W G3/8
L 198 X 158
Y 224
MANIFOLD DIM A DIM B PART NO. MANIFOLD DIM A DIM B PART NO.
OF STATIONS OF STATIONS
2 Stations 107 90 M531-1-2-P 8 Stations 305 288 M531-1-8-P
3 Stations 140 123 M531-1-3-P 9 Stations 338 321 M531-1-9-P
4 Stations 173 156 M531-1-4-P 10 Stations 371 354 M531-1-10-P
5 Stations 206 189 M531-1-5-P 11 Stations 404 387 M531-1-11-P
6 Stations 239 222 M531-1-6-P 12 Stations 437 420 M531-1-12-P
7 Stations 272 255 M531-1-7-P Adaptor kit SJ200115
BLANK STATION PLATE KIT SJ200116 ADAPTOR KIT SJ200115
Availability, design and specifications are subject to change without notice. All rights reserved.
DET. NO. DET. NO.
PART NAME PART NAME
NO REQ'D NO REQ'D
1 1 Blank Station Plate 1 1 Adaptor
2 2 Screw 2 2 Screw
3 2 Lockwasher 3 2 Lockwasher
4 3 O-ring 4 2 Screw
5 3 O-ring
6 3 O-ring
2014/R1