0% found this document useful (0 votes)
120 views4 pages

WatchGas XDI-F1 C744 V1 - 3

The WatchGas XDI-F1 gas sensor can utilize various sensor cell types to monitor an extensive range of gases. It has explosion proof housing, CANbus/4-20mA outputs, alarm relays, and data logging capabilities. It is designed for reliability in hazardous environments.

Uploaded by

SabilalArif
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
120 views4 pages

WatchGas XDI-F1 C744 V1 - 3

The WatchGas XDI-F1 gas sensor can utilize various sensor cell types to monitor an extensive range of gases. It has explosion proof housing, CANbus/4-20mA outputs, alarm relays, and data logging capabilities. It is designed for reliability in hazardous environments.

Uploaded by

SabilalArif
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

WatchGas XDI-F1

HAZARDOUS AREA GAS DETECTOR


C744

The XDI-F1 Gas Sensor is capable of utilising


a wide range of sensor cell types offering
an unmatched number of gases that may be
monitored. Standard 4~20mA signaling with
CANbus address enables the sensors to be
networked via the WatchGas Combi control
system or customer preferred monitoring
systems.

Key Features
• Explosion proof
• Rugged and reliable
• CANbus / 4~20mA outputs
• Addressable or stand alone
• Optional 2 alarm relays plus fault relay or 3 alarm
relays
• Wide range of gas types / sensors
• Hyper terminal communications / RS232 -live data
and set up with 232 adapter
• One man calibration
• Data logging

WatchGas B.V. | Klaverbaan 121 | 2908 KD Capelle aan den IJssel | The Netherlands | +31 (0)85 01 87 709 | www.watchgas.eu | [email protected]
WatchGas XDI-F1
HAZARDOUS AREA GAS DETECTOR
C744

SPECIFICATIONS
Weight 1.6kg
-20˚C to +55˚C - safe area use
Temperature
For hazardous area use see temperature ranges onC1227 (Ex certification summary)
Humidity 5 to 95% RH Non-condensing
Acoustic: 85dB @ 10cm
1, 2, 3 and Fault Alarms - mutable
Visual: Two line alpha numeric back lit display
Alarm Signal Power - Green LED
Alarms 1, 2, 3 - Red LEDs
Fault - Amber LED
Alarms inhibit - Amber LED
Housing Material: Copper free aluminium alloy, optional stainless steel
Sensor Material: Stainless steel 316S16
Housing & Material
Finish: Chemical resistant epoxy paint / RAL 9003 signal white
Optional - Marine grade finish
Addressable sensors only
Data Log Intervals - variable time, rollover/stop
Storage - 2,880 readings
Power Supply 18 to 35vDC 24v nominal
• 3 wire 4~20mA / 4 wire CANbus
• Optional relays -
• Low alarm S.P.C.O
Outputs
• High alarm S.P.C.O
• Fault alarm S.P.C.O
• Inhibit option during servicing Rating 0.5A @30vDC
Cable Entry 2 x M20 - 1.5 pitch - alternatives 25mm - 3/4 NPT
IP64 + water shield IP65
IP Rating
with hydrophobic screen IP66
EMC EN 50270
Explosion proof ATEX–IECEx
Safety Certification II 2G Ex db IIC T6…T4 Gb
II 2D Ex tb IIIC T85°C…T135°C Db
Sensor Type Infra Red, Electrochemical, Catalytic, Semiconductor, PID
Gas Type / Range Flammable gases - LEL / %Vol Toxic gases - ppm/ppb
Oxygen %vol
Accessories Collector Cone & Universal Fitting
Universal fitting (Test Gas Applicator/Spray Deflector) Water Shield - stainless steel
Flow Block - nylatron
Flow Block - stainless steel
Duct Mount Kit
Detector Head Weather Shield
F1 Sensor Thermal Jacket

WatchGas B.V. | Klaverbaan 121 | 2908 KD Capelle aan den IJssel | The Netherlands | +31 (0)85 01 87 709 | www.watchgas.eu | [email protected]
WatchGas XDI-F1
HAZARDOUS AREA GAS DETECTOR
C744

AVAILABLE GASES
Gases Measuring Range
0~100% LEL Catalytic Hydrocarbons, NH3, H2
Flammable Gases (LEL) 0~100% LEL Catalytic Hydrocarbons
0~100% LEL Catalytic Kerosene
O2 0~25% Vol Electrochemical
Oxygen

CO 0~200ppm Electrochemical
Carbon Monoxide

H2S 0~50ppm Electrochemical


Hydrogen Sulfide

SO2 0~5ppm Electrochemical


Sulfur Dioxide

NO2 0~5ppm Electrochemical


Nitrogen Dioxide

PH3 0~10ppm Electrochemical


Phosphine

H2 0~2000ppm Electrochemical
Hydrogen

Cl2 0~10ppm Electrochemical


Chlorine

HCN 0~10ppm Electrochemical


Hydrogen Cyanide

NO 0~10ppm Electrochemical
Nitric Oxide

HCl 0~10ppm Electrochemical


Hydrogen Chloride

O3 0~1ppm Electrochemical
Ozone

NH3 0~100ppm Electrochemical


Ammonia
0~1000ppm Electrochemical
0~5000ppm Electrochemical
ETO 0~25ppm Electrochemical
Ethylene Oxide

ClO2 0~1ppm Electrochemical


Chlorine Dioxide

HF 0~10ppm Electrochemical
Hydrogen Fluoride

H2O2 0~100ppm Electrochemical


Hydrogen Peroxide

Refrigerant Gases 0~1000ppm Semiconductor


VOC PID 10.6 eV Range 0~1000ppm
IR Flammable Hydrocarbon 0~100% LEL / 0~100 %vol.
IR CO2 CO2 0~5000 ppm / 0~2 %vol.(Standard) / 0~10 %vol. (Max Range)
CO2 0~100 %vol.
Formaldehyde 0 - 10 ppm

WatchGas B.V. | Klaverbaan 121 | 2908 KD Capelle aan den IJssel | The Netherlands | +31 (0)85 01 87 709 | www.watchgas.eu | [email protected]
WatchGas XDI-F1
HAZARDOUS AREA GAS DETECTOR
C744

For more information


www.watchgas.eu
[email protected]

Distributed by

WatchGas XDI- F1 C744 DS EN 14-06-21 v1.3 © 2021 WatchGas B.V.


WatchGas is dedicated to continuously improving its products. Therefore, the specifications and features mentioned in this datasheet are subject to change without prior notice.

WatchGas B.V. | Klaverbaan 121 | 2908 KD Capelle aan den IJssel | The Netherlands | +31 (0)85 01 87 709 | www.watchgas.eu | [email protected]

You might also like