Symap®: SYMAP® - Advanced Feeder Protection Relay

The document describes an advanced feeder protection relay called SYMAP F. It provides detailed information on the relay's protection, monitoring, control and communication capabilities for applications in switchgear and power distribution networks.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
262 views8 pages

Symap®: SYMAP® - Advanced Feeder Protection Relay

The document describes an advanced feeder protection relay called SYMAP F. It provides detailed information on the relay's protection, monitoring, control and communication capabilities for applications in switchgear and power distribution networks.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Product

Sheet

SYMAP®


SYMAP® - Advanced Feeder Protection


relay

www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0


Product Sheet

SYMAP® - Advanced Feeder Protection relay


SYMAP® F is designed for land and marine applications


for protection, control, measurement and monitoring of
low and medium voltages power systems. All protection
functions in SYMAP® F can be activated simultaneously,
and there are no limits to using all of them at the same
time. Hence follows, that SYMAP ® F can be used in
different switchgear and network applications.

SWICHGEAR Control and Interlocking

• single busbar
• double busbar
• duplex systems;
• interlocking at feeder level;
• interlocking at station level

NETWORKS

• isolated networks,
• resonant-earthed networks and
• solidly, and partially earthed networks

www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0


Product Sheet









PROTECTION APPLICATIONS
24 Overexcitation protection
25/A Synchrocheck
27 Undervoltage, instantaneous, definite time
27 B BUS undervoltage, definite time
32 Overload relay
46 Reverse phase current
47 Phase sequence voltage
49 Thermal overload protection
50 BF Breaker failure
50 Overcurrent, instantaneous
50 G/N Current earth fault, instantaneous
51 AC time overcurrent, definite time, IDMT
51 G/N AC ground overcurrent, definite time, IDMT
Overvoltage relay, instantaneous, definite time,
59
normal inverse
59 B BUS overvoltage relay, definite time
59 N Residual overvoltage
64 Ground overvoltage
67 AC AC directional overcurrent, definite time, IDMT
67GS/GD directional earth fault, definite time
78 Vector surge supervision
79 Auto reclosing
81 Frequency supervision
81 B BUS frequency supervision
86 Electrical lock out
94 Trip circuit supervision
95 i Inrush blocking
-- FF Fuse failure (voltages)
-- FL Fault locator
www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0


Product Sheet


MONITORING AND MEASUREMENT FUNCTIONS


• 3 × phase-to-phase and line voltages of feeder and BUS1
• 3 × phase feeder current (average/max. value)
• Frequencies of all systems (min./max. value)
• Ground current and voltage (max. value)
• Active and reactive power of each phase
• Active and reactive ground power
• Power factor of each phase
• Active and reactive power counter (reverse and forward,
constant and temporary)
• Operating hours
• Breaker cycles (life time)
• Harmonic waves of feeder current and voltage (up to 5th
harmonic wave)
• Circuit-breaker wear monitoring
• Trip circuit supervision (94)
• Fuse failure monitor
• 5 oscillographic fault records


COMMUNICATION INTERFACES


• 1 RS232 programming on front or rear
• 1 CANBUS interlocking, CB control, power management system..,
• RS422/RS485 port
• Fiber optic
• RJ45

PROTOCOLS
• PROFIBUS DP
• MODBUS
• IEC60870-5-103
• IEC61850

www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0


Product Sheet

PLC - powerful PLC function



Powerful PLC function. A large number of PLC functions and blocks, user programmable
inputs and outputs, large numbers of predefined logical results as event numbers allows user
powerful control and automation functions.

CONTROLS

• programmable inputs and outputs
• programmable interlocking
• five CB control
• programmable PMS functions


Hardware:

Housing: : small, special design from steel and aluminium (suitable for aggressive
environment)
Terminals: pluggable
Display : large graphical LCDisplay


ANALOG INPUTS FOR MEASURING AND PROTECTION

• 3 × CT for feeder current
• 1 × CT for ground current or sensitive ground current
• 3 × PT for feeder voltage
• 3 × PT for BUS1 voltage
• 1 × PT for ground voltage
Option:
• 3 × PT for BUS2 voltage

Analog I/O 0-20mA

• 2 x Analog outputs 4-20 mA (optional and hardware depending)
• 2 x Analog outputs 4-20 mA (optional and hardware depending)

www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0


Product Sheet

Binary I/O

Configurable binary inputs

• 14(20) binary inputs(basic unit)


Configurable binary outputs (output relays)

• 8 binary outputs
• 1 lock out relay
• 1 synchro on relay
• 2 shunts
• 4 binary outputs optional in basic card

Other functions:

ALARMS

• 80 configurable alarms
• 20 configurable groups


Two rows text description for each Alarm/Trip in chronological order.

Annunciator Page:

• 16 or 32 graphical states with user defined text description

www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0


Product Sheet

Event History

SYMAP® automatically collects and stores all activated events indicating their number, title,
coming/going status, and time stamp. A maximum of 5.000 events can be stored. In case of
overflow, data overwriting operates according to the first-in-first-out (FIFO) principle.

Detailed Protection Function History

SYMAP® F automatically collects and stores all activated events related to protection
functions with a time stamp.

• Event number
• Event title
• Time stamp
• Pickup or trip value (with fault phase indication)
• Setting value
• Trip time
• 3-line voltage and current pickup, synchronized with the trip event

A maximum of 1.000 protection function events can be stored. In case of overflow, the
oldest data will be recorded over.

Data Recorder (Option)

• Number of samples (6 - 72)
• Recording period (5 - 60 sec)
• Pre-trigger (0 - 100%)
• Trigger event (stop for recorder)


Diagnostics and Monitoring

SYMAP® F has three microprocessors that supervise each other, providing a watchdog
system. Important functions are laid out in a double redundancy combination, operating
independently with the second processor. Connected separately, an optional unit for short
circuit protection operates parallel to the SYMAP® F device and will do so even if the entire
voltage fails.

www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0


Product Sheet

SYMAP® F provides various diagnostic and monitoring functions as follows:



• All memories (ROMs, RAMs, EEPROMs)
• All analog reference voltages
• Automated test sequences
• Control power ON/OFF of SYMAP® F
• Binary input and output for control logic

The following supervising systems are offered by SYMAP® F:

• Self diagnostics of SYMAP® F
• The inputs of analog data (auxiliary circuit)
• The status and position of switching device and motor's on-off status
• Supervising supply of trip coil
• Gas pressure
• Temperature inside panel
• Each operating life of breaker (hours)

Extended Boards (special applications)

• extra binary inputs and outputs: yes
• PT100: yes

Software and accessory:


• Parameter Tool
• Recorder Tool
• Modbus Tool
• History Tool
• “SYMAP Parameter Tool (SPT)” ( NEW software, license is required )
• Firmware Tool
• • Communication cable

Firmware and SPT software:

• Multilingual