Symap®: SYMAP® - Advanced Feeder Protection Relay
Symap®: SYMAP® - Advanced Feeder Protection Relay
Sheet
SYMAP®
SYMAP® - Advanced Feeder Protection
relay
www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0
Product Sheet
• single busbar
• double busbar
• duplex systems;
• interlocking at feeder level;
• interlocking at station level
NETWORKS
• isolated networks,
• resonant-earthed networks and
• solidly, and partially earthed networks
www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0
Product Sheet
PROTECTION APPLICATIONS
24 Overexcitation protection
25/A Synchrocheck
27 Undervoltage, instantaneous, definite time
27 B BUS undervoltage, definite time
32 Overload relay
46 Reverse phase current
47 Phase sequence voltage
49 Thermal overload protection
50 BF Breaker failure
50 Overcurrent, instantaneous
50 G/N Current earth fault, instantaneous
51 AC time overcurrent, definite time, IDMT
51 G/N AC ground overcurrent, definite time, IDMT
Overvoltage relay, instantaneous, definite time,
59
normal inverse
59 B BUS overvoltage relay, definite time
59 N Residual overvoltage
64 Ground overvoltage
67 AC AC directional overcurrent, definite time, IDMT
67GS/GD directional earth fault, definite time
78 Vector surge supervision
79 Auto reclosing
81 Frequency supervision
81 B BUS frequency supervision
86 Electrical lock out
94 Trip circuit supervision
95 i Inrush blocking
-- FF Fuse failure (voltages)
-- FL Fault locator
www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0
Product Sheet
MONITORING AND MEASUREMENT FUNCTIONS
• 3 × phase-to-phase and line voltages of feeder and BUS1
• 3 × phase feeder current (average/max. value)
• Frequencies of all systems (min./max. value)
• Ground current and voltage (max. value)
• Active and reactive power of each phase
• Active and reactive ground power
• Power factor of each phase
• Active and reactive power counter (reverse and forward,
constant and temporary)
• Operating hours
• Breaker cycles (life time)
• Harmonic waves of feeder current and voltage (up to 5th
harmonic wave)
• Circuit-breaker wear monitoring
• Trip circuit supervision (94)
• Fuse failure monitor
• 5 oscillographic fault records
COMMUNICATION INTERFACES
• 1 RS232 programming on front or rear
• 1 CANBUS interlocking, CB control, power management system..,
• RS422/RS485 port
• Fiber optic
• RJ45
PROTOCOLS
• PROFIBUS DP
• MODBUS
• IEC60870-5-103
• IEC61850
www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0
Product Sheet
www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0
Product Sheet
Binary I/O
Configurable binary inputs
• 14(20) binary inputs(basic unit)
Configurable binary outputs (output relays)
• 8 binary outputs
• 1 lock out relay
• 1 synchro on relay
• 2 shunts
• 4 binary outputs optional in basic card
Other functions:
ALARMS
• 80 configurable alarms
• 20 configurable groups
Two rows text description for each Alarm/Trip in chronological order.
Annunciator Page:
• 16 or 32 graphical states with user defined text description
www.stuckegroup.com
PS.SYMAP.Feeder.ENG.REV0
Product Sheet
Event History
SYMAP® automatically collects and stores all activated events indicating their number, title,
coming/going status, and time stamp. A maximum of 5.000 events can be stored. In case of
overflow, data overwriting operates according to the first-in-first-out (FIFO) principle.
Detailed Protection Function History
SYMAP® F automatically collects and stores all activated events related to protection
functions with a time stamp.
• Event number
• Event title
• Time stamp
• Pickup or trip value (with fault phase indication)
• Setting value
• Trip time
• 3-line voltage and current pickup, synchronized with the trip event
A maximum of 1.000 protection function events can be stored. In case of overflow, the
oldest data will be recorded over.
Data Recorder (Option)
• Number of samples (6 - 72)
• Recording period (5 - 60 sec)
• Pre-trigger (0 - 100%)
• Trigger event (stop for recorder)
Diagnostics and Monitoring
SYMAP® F has three microprocessors that supervise each other, providing a watchdog
system. Important functions are laid out in a double redundancy combination, operating
independently with the second processor. Connected separately, an optional unit for short
circuit protection operates parallel to the SYMAP® F device and will do so even if the entire
voltage fails.